TECHNICAL MANUAL
AGS 400 NARROWLINE SINGLE GLAZED (101.6mm)
The AGS 400 Narrowline framing system has set the standard for centre glazed
framing for over two decades. With an aesthetically balanced look and the option
of beveled or square finishes, the AGS 400 Narrowline is the most versatile and
adaptable framing system in the range.
With a multitude of compatible window and door suites, the AGS 400 Narrowline
offers enormous design flexibility making this product ideal for commercial or
residential projects that require a bold modern look and high levels of structural
performance.
The table below is a summary of this manual’s update history. Contact Capral for details of past updates.
The table below shows the details of the latest manual update.
Please read in conjunction with Important Conditions – Index (also available on Capral website)
IMPORTANT CONDITIONS ..
By using this manual you agree to the following:
DISCLAIMER ..
Whilst best efforts have been made to ensure the details contained herein are accurate and correct, Capral is not
responsible for any loss or damage whatsoever arising as a result of any errors contained in this manual. Interpretation of
standards or codes within this manual is Capral’s interpretation of such codes. Responsibility for code compliance remains
with the user of this manual. In some cases product specifications may vary without notice. Users should not act or rely
upon any information contained in this manual without obtaining appropriate professional advice relating to their particular
circumstances. To the maximum extent permitted by law Capral disclaims all liability for loss or damage suffered by anyone
who acts or fails to act in reliance of this manual.
COPYRIGHT ..
This manual remains the property of Capral and contains information which is the subject of copyright. The manual or any
part of it may not be reproduced, copied or loaned in any form without the prior written permission of Capral. The manual is
to be returned to Capral on request.
Please read in conjunction with Important Conditions – Index (also available on Capral website)
SPECIFICATIONS Section 1 .
Product Specifications 1
ASSEMBLY Section 6 .
Assembly – Head & Posts 1
Assembly – Sill & Reverse Glazed Sill 2
Assembly – Mullion & Transom 3
Assembly – Reveal Head & Split Mullion 4
Assembly – Build In Brackets 5
Assembly – Glazing 6
Please read in conjunction with Important Conditions – Index (also available on Capral website)
TESTING Section 8.
Structural & Water Test Report Summary 9962S3A – F.F / F 1
Structural & Water Test Report Summary 9962S3B – F.F / F 2
Structural & Water Test Report Summary – F.F 3 - 10
Structural & Water Test Report Summary – F/F 11 - 17
Structural & Water Test Report Summary – F.F 18 - 30
Bushfire Test Report Summary 44400500.1 - F 31
Acoustic Test Report Summary ATF 1152 & ATF 1153 – F.F / F 32
Acoustic Test Report Summary 4870-25 & 4870-16 – F.F 33
Please read in conjunction with Important Conditions – Index (also available on Capral website)
SIZE LIMITATIONS
NOTE: Refer to the information below & Span Tables to check the maximum sizes that can be achieved for the
assigned performance requirements of the installation.
Note: The use of a standard Subsill has been assumed for the Water Performance Ratings listed above.
Please read in conjunction with Important Conditions – Index (also available on Capral website)
© 01-08-2013
01-07-2022 Sec1 Specifications - Page 1
400 Narrowline
Extrusions Scale 1:1
P.P.
44
IDENTIFIED BY
SINGLE PIP
101.6.
EN9457
LIGHT WEIGHT FRAME
Paint Perimeter: 196mm
Anodised Perimeter: 586mm
P.P.
44
IDENTIFIED BY
DOUBLE PIPS
101.6.
EN5010
STANDARD FRAME
Paint Perimeter: 195mm
Anodised Perimeter: 578mm
P.P.
44
IDENTIFIED BY
TRIPLE PIPS
101.6.
EN5011
HEAVY DUTY FRAME
Paint Perimeter: 195mm REFER TO SUB SILL & SUB FRAME TECHNICAL
Anodised Perimeter: 571mm MANUAL FOR SUB FRAME INFORMATION
Please read in conjunction with Important Conditions – Index (also available on Capral website)
P.P.
28
101.6.
EN5016
NARROW FRAME
Paint Perimeter: 176mm
Anodised Perimeter: 514mm
P.P.
47
25
101.6.
EP4845
EXTERNAL FLANGE FRAME
Paint Perimeter: 170mm
Anodised Perimeter: 537mm
P.P.
44
101.6.
EN5022
PLAIN FRAME
Paint Perimeter: 212mm
Anodised Perimeter: 466mm REFER TO SUB SILL & SUB FRAME TECHNICAL
MANUAL FOR SUB FRAME INFORMATION
Please read in conjunction with Important Conditions – Index (also available on Capral website)
22
P.P.
101.6.
EP5408
LIGHT S / M MULLION
Paint Perimeter: 130mm
Anodised Perimeter: 496mm
22
P.P.
101.6.
EP5409
HEAVY S / M MULLION
Paint Perimeter: 130mm
Anodised Perimeter: 510mm
22
P.P.
101.6.
EP15841
PLAIN S / M MULLION
Paint Perimeter: 268mm
Anodised Perimeter: 401mm
Please read in conjunction with Important Conditions – Index (also available on Capral website)
P.P.
44
101.6.
EN5020
STANDARD SILL / TRANSOM
Paint Perimeter: 130mm
Anodised Perimeter: 480mm
P.P.
44
101.6.
EN5021
TUBULAR TRANSOM
Paint Perimeter: 195mm
Anodised Perimeter: 442mm
101.6mm NARROWLINE - 80
EP10536
FLUSHLINE / NARROWLINE COUPLER
Paint Perimeter: NA
Anodised Perimeter: 258mm
Please read in conjunction with Important Conditions – Index (also available on Capral website)
43 14
P.P. P.P.
22
23
EP12761 EK7556
BRACED BEAD MIDRAIL BEAD
Paint Perimeter: 127mm Paint Perimeter: 100mm
Anodised Perimeter: 190mm Anodised Perimeter: 137mm
REFER TO SECTION 9 SPAN TABLES
FOR RECOMMENDED USAGE
43
P.P.
23
EN5032
SQUARE BEAD
Paint Perimeter: 100mm
110
Anodised Perimeter: 206mm
43
P.P.
23
P.P. 44
EN5031 EN2849
SLOPING BEAD 110mm MIDRAIL
Paint Perimeter: 100mm Paint Perimeter: 242mm
Anodised Perimeter: 184mm Anodised Perimeter: 524mm
Please read in conjunction with Important Conditions – Index (also available on Capral website)
101.6.
EP17033
90° POST
Paint Perimeter: 344mm
Anodised Perimeter: 515mm
101.6.
P.P.
101.6.
P.P.
EP17034
180° POST
Paint Perimeter: 344mm
Anodised Perimeter: 515mm
101.6.
Please read in conjunction with Important Conditions – Index (also available on Capral website)
101.6.
P.P.
EN5014
2 / 3 WAY CORNER
Paint Perimeter: 231mm
Anodised Perimeter: 769mm
101.6.
80
20
P.P.
39
EN5029
BUILD IN FILLER
Paint Perimeter: 145mm
Anodised Perimeter: 327mm
P.P.
21
141
EP10567
FIXING ADAPTOR
Paint Perimeter: 100mm REFER TO SUB SILL & SUB FRAME TECHNICAL
Anodised Perimeter: 395mm MANUAL FOR SUB FRAME INFORMATION
Please read in conjunction with Important Conditions – Index (also available on Capral website)
80
P.P. 16.5
P.P.
18
11
EN9499 EK5925
POCKETED FILLER FLUSH FILLER
Paint Perimeter: 100mm Paint Perimeter: 100mm
Anodised Perimeter: 307mm Anodised Perimeter: 100mm
15.5
P.P.
80
P.P.
12.5
16
7
EN5028 EP5447
FLAT FILLER NARROW FRAME HOOK BEAD
Paint Perimeter: 100mm Paint Perimeter: 100mm
Anodised Perimeter: 223mm Anodised Perimeter: 100mm
35
42
20
P.P. P.P.
25
80 EK9111
25 x 20 x 1.6 TRIM ANGLE
EQ6368 Paint Perimeter: 100mm
NAILING FIN ADAPTOR Anodised Perimeter: 100mm
Paint Perimeter: 152mm
Anodised Perimeter: 291mm
80
25
EP12061
REVEAL FIN ADAPTOR P.P.
Paint Perimeter: NA
19.5
EK9216
38.5
Please read in conjunction with Important Conditions – Index (also available on Capral website)
Structural Properties *
Extrusion Description
Ixx (103mm4) Iyy (103mm4) Zxx (103mm3) Zyy (103mm3)
EK5925 Flush Filler 0.452 1.356 0.062 0.166
EK7556 Midrail Bead 5.135 2.142 0.351 0.279
EK9111 25 x 20 x 1.6mm Trim Angle 2.535 4.411 0.169 0.253
EK9216 25 x 25 x 1.6mm Trim Angle 4.739 4.739 0.261 0.261
EN2849 110mm Midrail 882.009 229.611 14.514 9.548
EN5010 Standard Frame 112.318 670.803 3.868 13.156
EN5011 Heavy Duty Frame 125.145 767.577 4.254 15.062
EN5014 2/3 Way Corner 1394.889 619.712 26.443 12.194
EN5016 Narrow Frame 43.541 493.938 2.474 9.683
EN5020 Standard Sill 88.688 561.702 3.923 10.027
EN5021 Tubular Transom 138.075 544.145 5.088 9.249
EN5022 Plain Frame 117.515 704.801 3.756 13.929
EN5028 Flat Filler 0.736 133.141 0.150 3.329
EN5029 Build In Filler 13.864 128.100 0.524 3.178
EN5031 Sloping Bead 5.484 21.382 0.371 1.059
EN5032 Square Bead 9.507 33.066 0.535 1.513
EN9457 Lightweight Frame 99.719 588.566 3.409 11.541
EN9499 Pocketed Filler 7.966 135.101 0.622 3.377
EP10536 Flushline / Narrowline Coupler 3.722 260.478 0.379 6.322
EP10567 Fixing Adaptor 9.174 574.695 0.510 7.427
EP12061 Reveal Fin Adaptor 12.266 146.520 0.545 3.443
EP12761 Braced Bead 11.579 39.535 0.685 1.789
EP15841 Plain S/M Mullion 38.328 557.011 1.122 10.640
EP17033 90º Post 1625.043 1629.309 27.836 27.961
EP17034 180º Post 1552.986 1714.435 30.565 28.101
EP4845 External Flange Frame 56.903 547.520 1.605 9.971
EP5408 Light S/M Mullion 45.716 585.629 1.428 11.228
EP5409 Heavy S/M Mullion 80.458 1076.423 2.745 18.905
EP5447 Narrow Frame Hook Bead 0.816 0.789 0.098 0.076
EQ6368 Nailing Fin Adaptor 21.187 135.920 0.645 3.190
* NOTE: The structural properties listed above are using the orientations as listed within the extrusion pages.
Please read in conjunction with Important Conditions – Index (also available on Capral website)
© 01-11-2017
01-07-2022 Sec2 Extrusions - Page 9
400 Narrowline
Please read in conjunction with Important Conditions – Index (also available on Capral website)
321150 321149
400 SILL GASKET 400 FRAME GASKET
EACH EACH
(SPD04747) (SPD04746)
NOTE: EACH GASKET WHEN ASSEMBLED MEASURES 0.35MM. PLEASE TAKE THIS NOTE: EACH GASKET WHEN ASSEMBLED MEASURES 0.35MM. PLEASE TAKE
INTO CONSIDERATION WHEN DETERMINING SILL/TRANSOM CUT LENGTHS. THIS INTO CONSIDERATION WHEN DETERMINING HEAD CUT LENGTH.
316051 300163
CO-EXT EXPANSION JOINT SEAL BUILD IN BRACKET
500m ROLL - SC EACH
(10148) (M400565)
SPLIT MULLION
300059 300058
10g x 25mm SS PAN SCREW 10g x 12mm CSK SCREW
EACH EACH
(M028598) (M028354)
322026 307411
POCKET FILLER PLASTIC NAILING FIN
EACH - CLEAR CORNER COVER
(SPD04773) EACH
(SPD01182)
TRIM TO SUIT ALT TO 311592
311592
REINFORCED FOIL TAPE
50m ROLL
(PT018)
Please read in conjunction with Important Conditions – Index (also available on Capral website)
Please read in conjunction with Important Conditions – Index (also available on Capral website)
© 01-07-2022
DD-MM-YYYY Sec4:Formulas - Page 1
400 Narrowline
Machining - Jambs Scale 1:2
21 21 Ø5 21
21 TYP
CTR CTR CTR CTR
NARROW
CTR
24
HEAD FRAME
CTR
40
Ø5
TYP
Ø5
TYP
FLANGE
CTR
21
FRAME
TUBULAR
CTRS
36
TRANSOM CTR
4
33 33
CTR CTR
2 PIECE
CTRS
36
CTRS
25.5
TRANSOM
CTR
14
CTR
4
MIDRAIL
CTRS
76.5
CTR
14
SILL
CTR
40
CTR
4
VARIOUS VARIOUS
ALL JAMB & MULLION SECTIONS ALL JAMB & MULLION SECTIONS
10 10 22 22
CTR CTR CTR
CTR
EN9499 . EN5028 EN9499 . EN5028
POCKETED . FLAT FILLER POCKETED . FLAT FILLER
Please read in conjunction with Important Conditions – Index (also available on Capral website)
HEAD
CTR
40
Ø5
TYP
Ø10
SEE NOTE*
REVERSE
CTRS
TUBULAR
36
TRANSOM 12.5
CTR
Ø5
TYP
CTR
4
33 33
CTR ℄ CTR
Ø10 Ø10
SEE NOTE* SEE NOTE*
REVERSE 2
CTRS
PIECE
36
CTRS
25.5
TRANSOM
CTR
23
CTRS
10
CTR
3.5
CTR
90
CTRS
76.5
14
CTR
REVERSE
CTR
SILL
40
CTR
3.5
REVERSE MIDRAIL
VARIOUS VARIOUS
ALL JAMB & MULLION SECTIONS ALL JAMB & MULLION SECTIONS
10 10 22 22
CTR CTR CTR CTR
Please read in conjunction with Important Conditions – Index (also available on Capral website)
21
CTR
Ø10
CTR
50
TYP
CTR
50
EN5020
STANDARD SILL
WITH SUB SILL ONLY
3.2
50 50 EN5020
CTR 25 25 CTR EXTERNAL TRANSOM
NOT SUITABLE FOR REVERSE
Please read in conjunction with Important Conditions – Index (also available on Capral website)
CTR
50
TYP (3)
25
CTR
50
EN5021
EXTERNAL TUBULAR TRANSOM
NOT SUITABLE FOR REVERSE
Please read in conjunction with Important Conditions – Index (also available on Capral website)
5.5
5
6.5
EN5031
25 50
SLOPING BEAD
TYP CTR
50
CTR
EN5031
SLOPING BEAD 30° 30°
AS ABOVE
AS
ABOVE
EK7556 EN5032 . EP12761
MIDRAIL BEAD 25 50
SQUARE . BRACED BEAD TYP CTR
50
6
AS
ABOVE
EN5031 25 50
SLOPING BEAD TYP CTR
50
Please read in conjunction with Important Conditions – Index (also available on Capral website)
POCKETED FILLER
EN9499
150mm @ 600 CTRS
FRAME END GASKET*
321149
ALT. USE SMALL JOINT SEALANT
STANDARD FRAME
EN5010
FRAME (HEAD)
ASSEMBLED FRAME
180° POST
EP17034
180° POST
90° POST SIMILAR
Please read in conjunction with Important Conditions – Index (also available on Capral website)
© DD-MM-YYYY
01-07-2022 Sec6 Assembly - Page 1
400 Narrowline
Assembly - Sill & Reverse Glazed Sill Not To Scale
POCKETED FILLER
EN9499
150mm @ 600 CTRS
STANDARD FRAME
EN5010
STANDARD SILL
EN5020
Please read in conjunction with Important Conditions – Index (also available on Capral website)
POCKETED FILLER
EN9499
SEAL INTO POSITION FULL LENGTH
TUBULAR TRANSOM
EN5021
POCKET FILLER
320026
ENTIRE POCKET COMPLETELY
SEALED OVER POCKET FILLER SQUARE BEAD
WITH SILICONE EN5032
APPLY AFTER GLASS
CO-EXT EXPANSION
JOINT SEAL
316051
LIGHT S / M MULLION
EP5408
SEAL BOTTOM 100mm
SQUARE BEAD
EN5032
APPLY AFTER GLASS
STANDARD SILL/TRANSOM
EN5020
POCKETED FILLER
EN9499
SEAL INTO POSITION FULL LENGHT
REVERSE GLAZED
2-PIECE TRANSOM
SUB SILL MUST BE USED
Please read in conjunction with Important Conditions – Index (also available on Capral website)
© DD-MM-YYYY
01-07-2022 Sec6 Assembly - Page 3
400 Narrowline
Assembly - Reveal Head & Split Mullion Not To Scale
REVEAL
REVEAL
STAPLE OR
OTHER FIXING
STAPLE OR OTHER FIXING REINFORCED FOIL TAPE
311592
SEAL OVER MULLION OPENING
REINFORCED FOIL TAPE
311592
SEAL CORNERS & FRAME POCKET
ALT. USE 307411 NAILING FIN COVER
CO-EXIT EXPANSION
JOINT SEAL
316051
SILICON SEAL
BOTTOM 100mm
LIGHT S / M MULLION
EP5408 INSTALLED SPLIT MULLION
VIEW FROM INSIDE
SILL END GASKET*
321150
ALT. USE SMALL JOINT SEALANT
STANDARD SILL
EN5020
POCKETED FILLER
EN9499
SEAL INTO POSITION FULL LENGTH
SQUARE BEAD
EN5032
APPLIED AFTER GLASS
SUB SILL
EN6323
REFER TO SUB FRAME MANUAL
FOR REVEAL SUB SILL
SPLIT MULLION
Please read in conjunction with Important Conditions – Index (also available on Capral website)
EN5010
SILICONE BEAD
Please read in conjunction with Important Conditions – Index (also available on Capral website)
Please read in conjunction with Important Conditions – Index (also available on Capral website)
01
01
08 08
02
02
03
03
SUB FRAME
04 04 05 05 06 06 07 07
Please read in conjunction with Important Conditions – Index (also available on Capral website)
REFER TO SUB SILL & SUB FRAME TECHNICAL MANUAL FOR SUB FRAME DETAILS
SUB HEAD
1 POCKETED FILLER
SUB HEAD EN9499
150mm @ 600 CTRS
MIN
20 SMALL BULB SEAL
300841
44
STANDARD FRAME
9
GLASS HEIGHT=
EN5010
DOH +18
DOH
GLAZING WEDGE
2
9
SQUARE BEAD
TUBULAR EN5032
TRANSOM
44
POCKET FILLER
322026
TUBULAR TRANSOM
9
GLASS HEIGHT=
EN5021
DOH +18
DOH
2 STANDARD SILL
9
EN5020
2 PIECE GLASS SETTING BLOCK
TRANSOM SLOPING BEAD
44
EN5031
POCKETED FILLER
OUTSIDE
EN9499
9
GLASS HEIGHT=
DOH +18
DOH
BRACED BEAD
EP12761
STANDARD SILL
9
EN5020
3
SILICONE SEAL
SILL
SUB SILL
CLOSED CELL
BACKING ROD
2.5 6 2.5 6
6
Please read in conjunction with Important Conditions – Index (also available on Capral website)
REFER TO SUB SILL & SUB FRAME TECHNICAL MANUAL FOR SUB FRAME DETAILS
MIDRAIL BEAD
EK7556
2
REVERSE MIDRAIL 110mm MIDRAIL
110
GLAZING WEDGE
2 GLASS SETTING BLOCK
REVERSE
44
POCKET FILLER
TRANSOM 322026
STANDARD SILL
EN5020
POCKETED FILLER
DAYLIGHT OPENING = DOH
GLASS HEIGHT = DOH + 18
EN9499
TRANSOM HEIGHT = TH
SQUARE BEAD
EN5032
SILICONE SEAL
CLOSED CELL BACKING ROD
44
3 SUB SILL
SUB SILL END DAM
REVERSE SILL POCKETED FILLER
EN9499
150mm @ 600 CTRS
REVERSE GLAZING
REVERSE BEADED FRAMES ARE ONLY POSSIBLE IF DRAINAGE IS PROVIDED
THROUGH MULLIONS & JAMBS & MUST BE USED WITH SUBSILL. REFER
SECTION 5, PAGE 5
Please read in conjunction with Important Conditions – Index (also available on Capral website)
NOTE: BELOW INSTALLATION METHODS ARE INDICATIVE ONLY. HEADS SHOWN AS EXAMPLE, JAMBS SIMILAR
EXTERNAL CLADDING
LINTEL
INTERNAL
WALL LINING
ARCHITRAVE
SARKING
NAILING FIN ADAPTOR
EQ6368
BUILD IN FILLER
EN5029
1 REVEAL FIN ADAPTOR
HEAD EP12061
STANDARD FRAME
EN5010
POCKET FILLER
322026
OUTSIDE
1
25 x 25 x 1.6mm ANGLE
ANGLE FIX EK9111
25 x 20 x 1.6mm ANGLE
EK9111
STANDARD FRAME
EN5010
GLAZING WEDGE
Please read in conjunction with Important Conditions – Index (also available on Capral website)
NOTE: BELOW INSTALLATION METHODS ARE INDICATIVE ONLY. HEADS SHOWN AS EXAMPLE, JAMBS SIMILAR
SARKING
LINTEL
INTERNAL
WALL LINING
FLASHING BY
OTHERS
15
1 STAPLE OR
OTHER FIXING
HEAD
INLINE REVEAL
ARCHITRAVE
44
80mm REVEAL
10g x 12mm CSK
SCREW
FIX @ APPROPRIATE
CTRS
FRAME
EN5010
OUTSIDE
50
30
1
HEAD FIXING ADAPTOR
FIXING ADAPTOR FOR EP10567
CONCRETE 10g x 12mm CSK SCREW
44
300058
SILICONE SEAL
STANDARD FRAME
EN5010
Please read in conjunction with Important Conditions – Index (also available on Capral website)
REVERSE GLAZING
REVERSE BEADED FRAMES ARE ONLY POSSIBLE IF DRAINAGE IS PROVIDED
THROUGH MULLIONS & JAMBS & MUST BE USED WITH SUB SILL. REFER Sec5
4 5
STANDARD LIGHT
JAMB MULLION
OUTSIDE
5 5 4
MEDIUM HEAVY REVERSE
MULLION MULLION JAMB
SILICONE SEAL CLOSED CELL
POCKETED FILLER GLAZING WEDGE BACKING ROD
EN9499
HEAVY DUTY FRAME POCKETED FILLER
STANDARD FRAME EN5011 EN9499
EN5010 FULL HEIGHT WITH REVERSE TRANSOMS
OUTSIDE
* IF USING END GASKETS - EACH GASKET WHEN ASSEMBLED MEASURES 0.35MM. PLEASE TAKE THIS
INTO CONSIDERATION WHEN DETERMINING HEAD, SILL & TRANSOM CUT LENGTHS.
^ ENTIRE POCKET COMPLETELY SEALED OVER POCKET FILLER WITH SILICONE AT TRANSOMS
Please read in conjunction with Important Conditions – Index (also available on Capral website)
8 6 6
SUB JAMB LIGHT SPLIT PLAIN MULLION
MULLION MATING WITH OTHER PRODUCTS
2
20 GLASS WIDTH = DOW + 18 GLASS WIDTH = DOW + 18 2
MIN
44 DAYLIGHT = DOW* 46 DAYLIGHT = DOW* 46
OUTSIDE
6 6 4
MEDIUM HEAVY DUTY ALT. NARROW
SPLIT MULLION SPLIT MULLION JAMB
NARROW FRAME
SILICONE SEAL POCKET FILLER ^ CO-EXT EXPANSION JOINT SEAL EN5016
BOTTOM 100mm 322026 316051 TYP ANGLE TRIM
LIGHT S/M MULLION AT TRANSOM HEAVY S/M MULLION
EP5408 TRIMMED WHERE REQ. EP5409
OUTSIDE
* IF USING END GASKETS - EACH GASKET WHEN ASSEMBLED MEASURES 0.35MM. PLEASE TAKE THIS
INTO CONSIDERATION WHEN DETERMINING HEAD, SILL & TRANSOM CUT LENGTHS.
^ ENTIRE POCKET COMPLETELY SEALED OVER POCKET FILLER WITH SILICONE AT TRANSOMS
Please read in conjunction with Important Conditions – Index (also available on Capral website)
7
180° BOX COUPLER
28 101.6 44
7
90° BOX COUPLER
90° POST
EP17033
101.6
9 9
GLASS WIDTH = DOW + 18
44 DAYLIGHT = DOW* 44 101.6
^ ENTIRE POCKET COMPLETELY SEALED OVER POCKET FILLER WITH SILICONE AT TRANSOMS
Please read in conjunction with Important Conditions – Index (also available on Capral website)
7
180° CORNER MULLION
GLAZING WEDGE POCKETED FILLER
SILICONE BUTT POCKET FILLER ^ EN9499 FLUSH FILLER 2/3 WAY CORNER
322026 EK5925 EN5014
AT TRANSOM
TRIMMED WHERE REQ.
6 9
101.5
OUTSIDE
7
7
90° CORNER MULLION
FLUSHLINE / NARROWLINE
COUPLER
SILICONE FLAT FILLER
FLUSHLINE / NARROWLINE COUPLER FULL HEIGHT EN5028
EP10536
100mm FLUSHLINE FRAME
E19861 SHOWN AS EXAMPLE
SILICONE
FULL HEIGHT
REFER TO 419 FLUSHLINE MANUAL
FOR FRAME DETAILS STANDARD FRAME
EN5010
OUTSIDE
9
94 101.6
OUTSIDE
^ ENTIRE POCKET COMPLETELY SEALED OVER POCKET FILLER WITH SILICONE AT TRANSOMS
Please read in conjunction with Important Conditions – Index (also available on Capral website)
SILICONE
FULL HEIGHT
FLAT FILLER
EN5028
28
NARROW FRAME
EN5016
20mm PACKER
28
* IF USING END GASKETS - EACH GASKET WHEN ASSEMBLED MEASURES 0.35MM. PLEASE TAKE THIS
INTO CONSIDERATION WHEN DETERMINING HEAD, SILL & TRANSOM CUT LENGTHS.
Please read in conjunction with Important Conditions – Index (also available on Capral website)
Configuration: F.F / F
Glass: 6mm Clear Float
Bead / Glazing: External Bead / Roll in Wedges
Please read in conjunction with Important Conditions – Index (also available on Capral website)
Configuration: F.F / F
Glass: 6mm Clear Float
Bead / Glazing: External Bead / Silicone Seal
Please read in conjunction with Important Conditions – Index (also available on Capral website)
Configuration: F.F
Glass: 10.38mm Laminate
Bead / Glazing: External Bead / Silicone Seal
Please read in conjunction with Important Conditions – Index (also available on Capral website)
Configuration: F.F
Glass: 10.38mm Laminate
Bead / Glazing: External Bead / Roll in Wedges
Please read in conjunction with Important Conditions – Index (also available on Capral website)
Configuration: F.F
Glass: 10.38mm Laminate
Bead / Glazing: External Bead / Roll in Wedges
Please read in conjunction with Important Conditions – Index (also available on Capral website)
Configuration: F.F
Glass: 10.38mm Laminate
Bead / Glazing: External Bead / Captive Wedge (inside) / Roll in Wedge (outside)
Please read in conjunction with Important Conditions – Index (also available on Capral website)
Configuration: F.F
Glass: 8mm Toughened
Bead / Glazing: External Bead / Silicone Seal
Please read in conjunction with Important Conditions – Index (also available on Capral website)
Configuration: F.F
Glass: 10.38mm Laminate
Bead / Glazing: Internal Bead / Roll in Wedges
Please read in conjunction with Important Conditions – Index (also available on Capral website)
Configuration: F.F
Glass: 10.38mm Laminate
Bead / Glazing: External Bead / Silicone Seal
Please read in conjunction with Important Conditions – Index (also available on Capral website)
Configuration: F.F
Glass: 8mm Toughened
Bead / Glazing: External Bead / Silicone Seal
Please read in conjunction with Important Conditions – Index (also available on Capral website)
Configuration: F/F
Glass: 8.38mm Laminated
Bead / Glazing: Internal Bead / Captive Wedge (outside) / Roll in Wedge (inside)
Please read in conjunction with Important Conditions – Index (also available on Capral website)
Configuration: F/F
Glass: 8.38mm Laminated
Bead / Glazing: Internal Bead / Silicone Seal
Please read in conjunction with Important Conditions – Index (also available on Capral website)
Configuration: F/F
Glass: 8.38mm Laminated
Bead / Glazing: External Bead / Silicone Seal
Please read in conjunction with Important Conditions – Index (also available on Capral website)
Configuration: F/F
Glass: 6.38mm Laminated
Bead / Glazing: External Bead / Roll In Wedges
Please read in conjunction with Important Conditions – Index (also available on Capral website)
Configuration: F/F
Glass: 6.38mm Laminated
Bead / Glazing: External Bead / Silicone Seal
Please read in conjunction with Important Conditions – Index (also available on Capral website)
Configuration: F/F
Glass: 6.38mm Laminated
Bead / Glazing: Internal Bead / Roll In Wedges
Please read in conjunction with Important Conditions – Index (also available on Capral website)
Configuration: F/F
Glass: 6.38mm Laminated
Bead / Glazing: Internal Bead / Silicone Seal
Please read in conjunction with Important Conditions – Index (also available on Capral website)
Configuration: F.F
Glass: 8.38mm Laminated
Bead / Glazing: External Bead / Roll In Wedges
Please read in conjunction with Important Conditions – Index (also available on Capral website)
Configuration: F.F
Glass: 8.38mm Laminated
Bead / Glazing: External Bead / Roll In Wedges
Please read in conjunction with Important Conditions – Index (also available on Capral website)
Configuration: F.F
Glass: 8.38mm Laminated
Bead / Glazing: External Bead / Roll In Wedges
Please read in conjunction with Important Conditions – Index (also available on Capral website)
Configuration: F.F
Glass: 8.38mm Laminated
Bead / Glazing: External Bead / Roll In Wedges
Please read in conjunction with Important Conditions – Index (also available on Capral website)
Configuration: F.F
Glass: 8mm Toughened
Bead / Glazing: External Bead / Captive Wedge (inside) / Roll in Wedge (outside)
Please read in conjunction with Important Conditions – Index (also available on Capral website)
Configuration: F.F
Glass: 8mm Toughened
Bead / Glazing: External Bead / Captive Wedge (inside) / Roll in Wedge (outside)
Please read in conjunction with Important Conditions – Index (also available on Capral website)
Configuration: F.F
Glass: 8mm Toughened
Bead / Glazing: External Bead / Captive Wedge (inside) / Roll in Wedge (outside)
Please read in conjunction with Important Conditions – Index (also available on Capral website)
Configuration: F.F
Glass: 10.38mm Laminated
Bead / Glazing: External Bead / Captive Wedge (inside) / Roll in Wedge (outside)
Please read in conjunction with Important Conditions – Index (also available on Capral website)
Configuration: F.F
Glass: 10.38mm Laminated
Bead / Glazing: External Bead / Captive Wedge (inside) / Roll in Wedge (outside)
Please read in conjunction with Important Conditions – Index (also available on Capral website)
Configuration: F.F
Glass: 6.38mm Laminated
Bead / Glazing: External Bead / Captive Wedge (inside) / Roll in Wedge (outside)
Please read in conjunction with Important Conditions – Index (also available on Capral website)
Configuration: F.F
Glass: 10.38mm Laminated
Bead / Glazing: External Bead / Captive Wedge (inside) / Roll in Wedge (outside)
Please read in conjunction with Important Conditions – Index (also available on Capral website)
Configuration: F.F
Glass: 10.38mm Laminated
Bead / Glazing: External Bead / Captive Wedge (inside) / Roll in Wedge (outside)
Please read in conjunction with Important Conditions – Index (also available on Capral website)
Configuration: F.F
Glass: 10.38mm Laminated
Bead / Glazing: External Bead / Captive Wedge (inside) / Roll in Wedge (outside)
Please read in conjunction with Important Conditions – Index (also available on Capral website)
TEST RESULTS:
Performance Criteria Time to Failure (min) Position of Failure
Formation of through-gaps greater than 3mm. No Failure -
Sustained failure for 10sec. on the non-fire side. No Failure -
Flaming on the fire –exposed side at the end of the 60min.
No Failure -
test period.
Radiant heat flux 365mm from the non-fire exposed side
No Failure -
exceeding 15kW/m2.
Mean and maximum temperature rises greater than 140K & No applicable for glazed
-
180K. elements.
Radiant heat flux 250mm from the specimen, greater than
No Failure -
3kW/m2 between 20mins. and 60mins.
Mean and maximum temperature of internal faces
Not applicable for glazed
exceeding 250ºC and 300ºC respectively between 20mins. -
elements.
and 60mins. after commencement of test.
Crib Class A Peak Heat Flux 40 kW/m2
Test Result BAL-A40
Please read in conjunction with Important Conditions – Index (also available on Capral website)
© 01-12-2017
01-07-2022 Sec8 Testing - Page 31
400 Narrowline
Test Report Summary
ACOUSTIC
Performed by: Australian Hearing National Acoustic Laboratories, New South Wales – October, 2001
Configuration: F.F / F
Please read in conjunction with Important Conditions – Index (also available on Capral website)
ACOUSTIC
Performed by: Australian Hearing National Acoustic Laboratories, New South Wales – October, 2012
Configuration: F.F
Please read in conjunction with Important Conditions – Index (also available on Capral website)
Note:
Serviceability pressures have been limited to a maximum Serviceability
Pressure of 4000Pa.
NOTE: This table is based on a combination of approved AS2047 testing data and theoretical section properties.
A maximum stress level of 110MPa has been applied when generating this table.
Please read in conjunction with Important Conditions – Index (also available on Capral website)
© 14-06-2016
01-07-2022 Sec9 Span Tables - Page 1
400 Narrowline
Span Table
MEDIUM MULLION - EN5010 / EN9499
Note:
Serviceability pressures have been limited to a maximum Serviceability
Pressure of 4000Pa.
NOTE: This table is based on a combination of approved AS2047 testing data and theoretical section properties.
A maximum stress level of 110MPa has been applied when generating this table.
Please read in conjunction with Important Conditions – Index (also available on Capral website)
Note:
Serviceability pressures have been limited to a maximum Serviceability
Pressure of 4000Pa.
NOTE: This table is based on a combination of approved AS2047 testing data and theoretical section properties.
A maximum stress level of 110MPa has been applied when generating this table.
Please read in conjunction with Important Conditions – Index (also available on Capral website)
© 14-06-2016
01-07-2022 Sec9 Span Tables - Page 3
400 Narrowline
Span Table
LIGHT SPLIT MULLION - EP5408 / EP5408
Note:
Serviceability pressures have been limited to a maximum Serviceability
Pressure of 4000Pa.
NOTE: This table is based on a combination of approved AS2047 testing data and theoretical section properties.
A maximum stress level of 110MPa has been applied when generating this table.
Please read in conjunction with Important Conditions – Index (also available on Capral website)
Note:
Serviceability pressures have been limited to a maximum Serviceability
Pressure of 4500Pa.
NOTE: This table is based on a combination of approved AS2047 testing data and theoretical section properties.
A maximum stress level of 110MPa has been applied when generating this table.
Please read in conjunction with Important Conditions – Index (also available on Capral website)
© 14-06-2016
01-07-2022 Sec9 Span Tables - Page 5
400 Narrowline
Span Table
HEAVY SPLIT MULLION - EP5409 / EP5409
Note:
Serviceability pressures have been limited to a maximum Serviceability
Pressure of 5200Pa.
NOTE: This table is based on a combination of approved AS2047 testing data and theoretical section properties.
A maximum stress level of 110MPa has been applied when generating this table.
Please read in conjunction with Important Conditions – Index (also available on Capral website)
Note:
Serviceability pressures have been limited to a maximum pressure of
4500Pa.
NOTE: This table is based on theoretical section properties only, not on on approved AS2047 testing data.
A maximum stress level of 110MPa has been applied when generating this table.
Please read in conjunction with Important Conditions – Index (also available on Capral website)
© 01-11-2017
01-07-2022 Sec9 Span Tables - Page 7
400 Narrowline
Span Table
90° BOX COUPLER - EN5010 / EP17033 / EN5010
Note:
Serviceability pressures have been limited to a maximum pressure of
4500Pa.
NOTE: This table is based on theoretical section properties only, not on approved AS2047 testing data.
A maximum stress level of 110MPa has been applied when generating this table.
Please read in conjunction with Important Conditions – Index (also available on Capral website)
Note:
Serviceability pressures have been limited to a maximum Serviceability
Pressure of 4500Pa.
NOTE: This table is based on a combination of approved AS2047 testing data and theoretical section properties.
A maximum stress level of 110MPa has been applied when generating this table.
Please read in conjunction with Important Conditions – Index (also available on Capral website)
© 14-06-2016
01-07-2022 Sec9 Span Tables - Page 9
400 Narrowline
Span Table
PLAIN MULLION - EP15841 / EP15841
Note:
Serviceability pressures have been limited to a maximum Serviceability
Pressure of 4000Pa.
NOTE: This table is based on theoretical section properties, not on approved tests as specified by AS2047.
A maximum stress level of 110MPa has been applied when generating this table.
Please read in conjunction with Important Conditions – Index (also available on Capral website)
Note:
Serviceability pressures have been limited to a maximum Serviceability
Pressure of 4000Pa.
NOTE: This table is based on theoretical section properties, not on approved tests as specified by AS2047.
A maximum stress level of 110MPa has been applied when generating this table.
Please read in conjunction with Important Conditions – Index (also available on Capral website)
© 14-06-2016
01-07-2022 Sec9 Span Tables - Page 11
400 Narrowline
Span Table
HEAVY PLAIN / POCKET MULLION - EP15841 / EP5409
Note:
Serviceability pressures have been limited to a maximum Serviceability
Pressure of 4500Pa.
NOTE: This table is based on theoretical section properties, not on approved tests as specified by AS2047.
A maximum stress level of 110MPa has been applied when generating this table.
Please read in conjunction with Important Conditions – Index (also available on Capral website)
Transom Spacing
Maximum Design Pressure (kPa)
(mm)
S (L/250) 3.000 * 1.980 1.226 0.817 0.574 0.420 -
1500
U 3.618 * 2.347 * 1.670 * 1.258 0.987 0.797 -
S (L/250) 3.000 * 2.016 1.259 0.844 0.595 0.437 -
1425
U 3.631 * 2.394 * 1.719 * 1.302 1.025 * 0.830 -
S (L/250) 3.000 * 2.063 1.298 0.875 0.619 0.455 -
1350
U 3.671 * 2.456 * 1.777 * 1.353 1.069 * 0.867 -
S (L/250) 3.000 * 2.122 * 1.346 0.911 0.647 0.477 -
1275
U 3.737 * 2.533 * 1.846 * 1.412 * 1.118 * 0.909 -
S (L/250) 3.000 * 2.195 * 1.401 * 0.953 0.679 0.502 -
1200
U 3.832 * 2.627 * 1.927 * 1.480 * 1.176 * 0.958 -
S (L/250) 3.000 * 2.283 * 1.467 * 1.002 0.716 0.530 0.404
1125
U 3.958 * 2.740 * 2.022 * 1.559 * 1.241 * 1.013 * 0.843
S (L/250) 3.000 * 2.390 * 1.545 * 1.059 0.759 0.563 0.429
1050
U 4.118 * 2.876 * 2.134 * 1.651 * 1.318 * 1.077 * 0.898
S (L/250) 3.000 * 2.520 * 1.637 * 1.126 0.809 0.601 0.459
975
U 4.319 * 3.041 * 2.267 * 1.759 * 1.407 * 1.152 * 0.961
S (L/250) 3.000 * 2.677 * 1.748 * 1.206 0.868 0.646 0.494
900
U 4.500 * 3.239 * 2.425 * 1.887 * 1.512 * 1.240 * 1.036 *
S (L/250) 3.000 * 2.869 * 1.881 * 1.302 0.939 0.700 0.536
825
U 4.500 * 3.479 * 2.615 * 2.040 * 1.638 * 1.345 * 1.125 *
S (L/250) 3.000 * 3.000 * 2.044 * 1.418 * 1.025 * 0.765 0.587
750
U 4.500 * 3.775 * 2.847 * 2.226 * 1.790 * 1.472 * 1.232 *
S (L/250) 3.000 * 3.000 * 2.246 * 1.562 * 1.131 * 0.845 0.649
675
U 4.500 * 4.143 * 3.134 * 2.456 * 1.977 * 1.627 * 1.363 *
S (L/250) 3.000 * 3.000 * 2.503 * 1.744 * 1.265 * 0.946 0.727
600
U 4.500 * 4.500 * 3.496 * 2.745 * 2.213 * 1.823 * 1.528 *
Transom Width (mm) 1500 1750 2000 2250 2500 2750 3000
NOTE: This table is based on a combination of approved AS2047 testing data and theoretical section properties.
A maximum stress level of 110MPa has been applied when generating this table.
Please read in conjunction with Important Conditions – Index (also available on Capral website)
© 14-06-2016
01-07-2022 Sec9 Span Tables - Page 13
400 Narrowline
Span Table
2 PIECE TRANSOM - EN5020 / EN9499
Note:
Serviceability pressures have been limited to a maximum
Serviceability Pressure of 3000Pa.
Serviceability pressures have not been limited by water
performance. Where water performance is necessary, refer to
Product Specifications page.
As lowlight mullions under transom are assumed, no
consideration has been given to the deadload component of
loading.
Transom Spacing
Maximum Design Pressure (kPa)
(mm)
S (L/250) 3.000 * 2.536 * 1.569 * 1.046 * 0.735 0.538 0.406
1500
U 4.500 * 3.156 * 2.245 * 1.692 * 1.327 * 1.071 * 0.885
S (L/250) 3.000 * 2.582 * 1.612 * 1.080 0.762 0.559 0.423
1425
U 4.500 * 3.220 * 2.311 * 1.751 * 1.378 * 1.116 * 0.923
S (L/250) 3.000 * 2.642 * 1.663 * 1.120 0.793 0.583 0.442
1350
U 4.500 * 3.303 * 2.390 * 1.820 * 1.437 * 1.166 * 0.966
S (L/250) 3.000 * 2.717 * 1.723 * 1.166 0.829 0.611 0.464
1275
U 4.500 * 3.406 * 2.483 * 1.899 * 1.504 * 1.223 * 1.015 *
S (L/250) 3.000 * 2.810 * 1.794 * 1.220 0.869 0.642 0.489
1200
U 4.500 * 3.532 * 2.591 * 1.991 * 1.581 * 1.288 * 1.071 *
S (L/250) 3.000 * 2.924 * 1.878 * 1.283 0.917 0.679 0.517
1125
U 4.500 * 3.685 * 2.719 * 2.097 * 1.669 * 1.363 * 1.134 *
S (L/250) 3.000 * 3.000 * 1.978 * 1.356 0.972 0.721 0.550
1050
U 4.500 * 3.868 * 2.870 * 2.220 * 1.772 * 1.449 * 1.208 *
S (L/250) 3.000 * 3.000 * 2.096 * 1.442 * 1.036 * 0.770 0.588
975
U 4.500 * 4.089 * 3.048 * 2.366 * 1.892 * 1.549 * 1.293 *
S (L/250) 3.000 * 3.000 * 2.238 * 1.544 * 1.112 * 0.828 0.633
900
U 4.500 * 4.355 * 3.261 * 2.538 * 2.034 * 1.668 * 1.393 *
S (L/250) 3.000 * 3.000 * 2.409 * 1.667 * 1.203 * 0.897 0.687
825
U 4.500 * 4.500 * 3.516 * 2.744 * 2.203 * 1.809 * 1.512 *
S (L/250) 3.000 * 3.000 * 2.618 * 1.816 * 1.313 * 0.980 0.751
750
U 4.500 * 4.500 * 3.828 * 2.994 * 2.407 * 1.979 * 1.656 *
S (L/250) 3.000 * 3.000 * 2.877 * 2.001 * 1.448 * 1.083 * 0.831
675
U 4.500 * 4.500 * 4.214 * 3.302 * 2.659 * 2.188 * 1.833 *
S (L/250) 3.000 * 3.000 * 3.000 * 2.234 * 1.619 * 1.212 * 0.931
600
U 4.500 * 4.500 * 4.500 * 3.691 * 2.976 * 2.451 * 2.054 *
Transom Width (mm) 1500 1750 2000 2250 2500 2750 3000
NOTE: This table is based on a combination of approved AS2047 testing data and theoretical section properties.
A maximum stress level of 110MPa has been applied when generating this table.
Please read in conjunction with Important Conditions – Index (also available on Capral website)
Above Midrail
Maximum Design Pressure (kPa)
Height (mm)
S (L/250) 2.200 2.200 2.200 2.200 1.670 1.175 0.853
2100
U 3.300 3.300 3.300 3.300 3.300 3.230 2.561
S (L/250) 2.200 2.200 2.200 2.200 1.670 1.175 0.853
2025
U 3.300 3.300 3.300 3.300 3.300 3.230 2.561
S (L/250) 2.200 2.200 2.200 2.200 1.670 1.175 0.853
1950
U 3.300 3.300 3.300 3.300 3.300 3.230 2.561
S (L/250) 2.200 2.200 2.200 2.200 1.670 1.175 0.853
1875
U 3.300 3.300 3.300 3.300 3.300 3.230 2.561
S (L/250) 2.200 2.200 2.200 2.200 1.670 1.175 0.853
1800
U 3.300 3.300 3.300 3.300 3.300 3.230 2.561
S (L/250) 2.200 2.200 2.200 2.200 1.670 1.175 0.855
1725
U 3.300 3.300 3.300 3.300 3.300 3.230 2.565
S (L/250) 2.200 2.200 2.200 2.200 1.670 1.175 0.858
1650
U 3.300 3.300 3.300 3.300 3.300 3.230 2.577
S (L/250) 2.200 2.200 2.200 2.200 1.670 1.177 0.863
1575
U 3.300 3.300 3.300 3.300 3.300 3.236 2.596
S (L/250) 2.200 2.200 2.200 2.200 1.670 1.182 0.871
1500
U 3.300 3.300 3.300 3.300 3.300 3.253 2.622
S (L/250) 2.200 2.200 2.200 2.200 1.672 1.191 0.881
1425
U 3.300 3.300 3.300 3.300 3.300 3.280 2.656
S (L/250) 2.200 2.200 2.200 2.200 1.681 1.203 0.894
1350
U 3.300 3.300 3.300 3.300 3.300 3.300 2.698
S (L/250) 2.200 2.200 2.200 2.200 1.696 1.219 0.909
1275
U 3.300 3.300 3.300 3.300 3.300 3.300 2.749
S (L/250) 2.200 2.200 2.200 2.200 1.717 1.240 0.927
1200
U 3.300 3.300 3.300 3.300 3.300 3.300 2.808
Midrail Width (mm) 900 1050 1200 1350 1500 1650 1800
NOTE: This table is based on theoretical section properties, not on approved tests as specified by AS2047.
A maximum stress level of 110MPa has been applied when generating this table.
Please read in conjunction with Important Conditions – Index (also available on Capral website)
© 16-06-2016
01-07-2022 Sec9 Span Tables - Page 15
400 Narrowline
Maximum Glass Thickness Table - Deadload Assessment
TUBULAR TRANSOM - EN5021
Note:
Glass thickness has been limited to 10mm as dictated by the capacity of
the suite.
These tables have been developed to assist Fabricators in making an
assessment of the maximum glass thickness that the transom member can
support before it is considered unstable (deflection & stress).
Wind load and human impact requirements are not included in the tables
below. A glass thickness assessment for windload and human impact must
still be completed in accordance with AS1288.
Height Above
Maximum Glass Thickness with Support Blocks at 1/4 Points (mm)
Transom (mm)
1200 10 8 6 4 - - - - -
1100 10 10 6 5 - - - - -
1000 10 10 6 5 4 - - - -
900 10 10 8 6 4 - - - -
800 10 10 8 6 5 4 - - -
700 10 10 10 8 6 4 - - -
600 10 10 10 8 6 5 4 - -
Transom Width (mm) 1400 1600 1800 2000 2200 2400 2600 2800 3000
Downward
2.3 2.7 3.0 3.3 3.7 4.0 4.3 4.7 5.0
Deflection (mm)
Height Above
Maximum Glass Thickness with Support Blocks at 1/8 Points (mm)
Transom (mm)
1200 10 10 10 8 6 5 4 - -
1100 10 10 10 8 6 5 4 - -
1000 10 10 10 10 6 6 4 - -
900 10 10 10 10 8 6 5 4 -
800 10 10 10 10 8 6 6 4 -
700 10 10 10 10 10 8 6 5 4
600 10 10 10 10 10 10 8 6 5
Transom Width (mm) 1400 1600 1800 2000 2200 2400 2600 2800 3000
Downward
2.3 2.7 3.0 3.3 3.7 4.0 4.3 4.7 5.0
Deflection (mm)
NOTE: This table is based on theoretical section properties, not on approved tests as specified by AS2047.
A deflection ratio of L/600 has been assumed, resulting in the individual deflection figures listed on the tables.
Please read in conjunction with Important Conditions – Index (also available on Capral website)
Wind load and human impact requirements are not included in the tables
below. A glass thickness assessment for windload and human impact must
still be completed in accordance with AS1288.
Height Above
Maximum Glass Thickness with Support Blocks at 1/4 Points (mm)
Transom (mm)
1200 8 6 4 - - - - - -
1100 10 6 4 - - - - - -
1000 10 6 5 - - - - - -
900 10 8 6 4 - - - - -
800 10 8 6 4 - - - - -
700 10 10 6 5 4 - - - -
600 10 10 8 6 4 - - - -
Transom Width (mm) 1400 1600 1800 2000 2200 2400 2600 2800 3000
Downward
2.3 2.7 3.0 3.3 3.7 4.0 4.3 4.7 5.0
Deflection (mm)
Height Above
Maximum Glass Thickness with Support Blocks at 1/8 Points (mm)
Transom (mm)
1200 10 10 8 6 4 - - - -
1100 10 10 8 6 5 - - - -
1000 10 10 10 6 5 4 - - -
900 10 10 10 8 6 4 - - -
800 10 10 10 8 6 5 4 - -
700 10 10 10 10 6 6 4 - -
600 10 10 10 10 8 6 5 4 -
Transom Width (mm) 1400 1600 1800 2000 2200 2400 2600 2800 3000
Downward
2.3 2.7 3.0 3.3 3.7 4.0 4.3 4.7 5.0
Deflection (mm)
NOTE: This table is based on theoretical section properties, not on approved tests as specified by AS2047.
A deflection ratio of L/600 has been assumed, resulting in the individual deflection figures listed on the tables.
Please read in conjunction with Important Conditions – Index (also available on Capral website)
© 14-06-2016
01-07-2022 Sec9 Span Tables - Page 17
400 Narrowline
Maximum Glass Thickness Table - Deadload Assessment
110mm MIDRAIL - EN2849
Note:
Glass thickness has been limited to 10mm according to the capacity of
the suite.
Wind load and human impact requirements are not included in the tables
below. A glass thickness assessment for windload and human impact
must still be completed in accordance with AS1288.
Height Above
Maximum Glass Thickness with Support Blocks at 1/4 Points (mm)
Midrail (mm)
2150 10 10 10 10 10 10 10
1950 10 10 10 10 10 10 10
1800 10 10 10 10 10 10 10
1650 10 10 10 10 10 10 10
1500 10 10 10 10 10 10 10
1350 10 10 10 10 10 10 10
1200 10 10 10 10 10 10 10
Midrail Width (mm) 600 800 1000 1200 1400 1600 1800
Downward
1.0 1.3 1.7 2.0 2.3 2.7 3.0
Deflection (mm)
Height Above
Maximum Glass Thickness with Support Blocks at 1/8 Points (mm)
Midrail (mm)
2150 10 10 10 10 10 10 10
1950 10 10 10 10 10 10 10
1800 10 10 10 10 10 10 10
1650 10 10 10 10 10 10 10
1500 10 10 10 10 10 10 10
1350 10 10 10 10 10 10 10
1200 10 10 10 10 10 10 10
Midrail Width (mm) 600 800 1000 1200 1400 1600 1800
Downward
1.0 1.3 1.7 2.0 2.3 2.7 3.0
Deflection (mm)
Please read in conjunction with Important Conditions – Index (also available on Capral website)