1.Plant Capacity
Normal Condition
Plant's raw water inflow = 10 MLD
WTP operating hours per day = 16 hr/day
Plant's raw water inflow = 625 m3/hr
Plant's raw water inflow = 0.174 m3/s
2.Sedimentation Tanks
3.Flocculation Tanks
4. Filters
Sizing of Filter
Filtration flow rate = 208.3 m3/hr
No of filter = 3
Length = 13.5 m
Width of filter bed = 6 m
Filtration area required = 81.00 m2
Filtration flow rate = 2.57 m3/m2/hr Requirement : 5 - 8 m3/m2/hr
No of tank = 1
Length = 28.4 m
Width = 36.6 m
Height = 4 m
Volume per tank = 4,158 m3
Inflow per tank = 0.174 m3/s
Retention time = 6.65 hrs