Blue Plus - 240520 - 150743
Blue Plus - 240520 - 150743
Blue Plus - 240520 - 150743
PART 1 GENERAL:
1. Glass products.
2. Laminated glass.
3. Insulating glass.
1.4 SUBMITTALS
1.6 MOCK-UPS
1.7 WARRANTY
Visit https://www.guardianglass.com/me/en/warranty-information
PART 2 PRODUCTS:
2.1 MANUFACTURERS
a. Annealed Clear Float Float Glass: ASTM C 1036, JIS R 3202 and EN 572 Type 1, Class
1, Quality q3.
b. Glass Thickness: 6mm (1/4 inch)
c. Vacuum Deposition Sputtered Coating: EN 1096, ASTM C 1376
d. Coating on Surface No. 2: SunGuard® HD Plus Blue T
e. Heat Treatment: [None] [Heat-strengthened, ASTM C 1048, Kind HS and EN 1863]
[Tempered; ASTM C 1048, Kind FT; and EN 12150] as necessary to meet applicable codes
and performance requirements.
a. Annealed Clear Float Float Glass: ASTM C 1036, JIS R 3202 and EN 572 Type 1, Class
1, Quality q3.
b. Glass Thickness: 6mm
c. Vacuum Deposition Sputtered Coating: EN 1096, ASTM C 1376
d. Coating on Surface No. 4: No coating
e. Heat Treatment: [None] [Heat-strengthened, ASTM C 1048, Kind HS and EN 1863]
[Tempered; ASTM C 1048, Kind FT; and EN 12150] as necessary to meet applicable codes
and performance requirements.
Specifier Notes: Specify the method of heat treatment. Guardian recommends heat-
strengthened where necessary for thermal stress management or other reasons, unless fully
tempered glass is specifically required.
j. Maximum peak-to-valley roll wave 0.003 inch (0.08 mm) in the central area of the glass
lite, and 0.008 inch (0.20 mm) within 12 inches (305 mm) of the leading and trailing edge of
the lite, per measured in accordance with ASTM C 1651, or EN12150 and EN 1863.
k. Maximum center-kink of 0.001 inch (0.025 mm) when roll wave is measured over the
surface of the glass perpendicular to the direction of travel through the tempering furnace.
l. Maximum localized and overall bow (warp) per lite shall be 0.031 inch (0.79 mm) per
305mm: one-half of maximum allowed by ASTM C 1048, or EN 12150 and EN 1863.
m. Measure glass lites for optical distortion using Osprey® (version 7 or higher, by Lite
Sentry) on-line distortion measurement system (or manufacturer approved equivalent).
Retain test reports for three years following substantial completion. Submit test reports upon
Architect's request.
1. Laminated Safety Glass: Complies with ANSI Z97.1 and 16 CFR 1201 test requirements for
Category II.
1. Sealing System: Dual seal, with polyisobutylene primary and silicone secondary sealants.
a. Secondary sealants approved by coated glass manufacturer.
2. Metallic Spacer: [Manufacturer's standard spacer material and construction]
[Aluminum with clear anodic finish] [Thermally broken aluminum] [Stainless steel], with
desiccant consisting of molecular sieve or silica gel, or a blend of both.
3. Non-Metallic Warm Edge Spacer: Low-conductivity, high wind load-resistant structural
silicone spacer, with integrally incorporated desiccant and narrow sightline profile. Please
add appropriate information below:
Spacer width: ............................
Spacer Height: ............................
Spacer Manufacturer: ............................
B. Edge Deletion: Delete low-E coating at perimeter of coated lite prior to fabrication of
insulating glass units according to coated glass manufacturer’s instructions.
A. Sealant Uniformity: Perform IGMA Sealant Uniformity of Mix Test not less than once per
shift. Submit test reports upon Architect's request.
B. Residual Moisture Content: Perform IGMA Residual Moisture Content by Head of
Absorption Test. Perform test in accordance with desiccant manufacturer’s written
recommendations. Submit test reports upon Architect's request.
C. Anisotropy (Iridescence): Perform anisotropy (iridescence) scan utilizing detection system
approved by glass manufacturer. Perform test in accordance with detection system
manufacturer’s written instructions. Continuously monitor production and record results.
Maintain results for a period of not less than 10 years.
D. Color Variation of Glass Coatings: Provide vacuum deposition coatings on glass
complying with color variation limits specified in EN 1096. Perform color monitoring utilizing
spectrophotometer equipment approved by glass manufacturer. Perform test in accordance
with manufacturer’s approved procedure. Test finished insulated glass units in accordance
with reflected color specifications and in comparison, to approved mockup control sample.
Statistically monitor production and record results. Maintain results for a period of not less
than 10 years.
Web: www.guardianglass.com
Email: [email protected]
Acoustic data: All acoustic data for your glazing configuration can be found at Glass
Analytics
The products in this publication are sold subject to Guardian‘s standard terms and
conditions of sale and any applicable written warranties (available at
www.guardianglass.com or from your local Guardian representative upon request). It is
the responsibility of the purchaser to confirm that the products are suitable for their
intended application in compliance with the applicable laws and regulations. Please
contact your local Guardian representative to obtain any applicable handling and
fabrication guides and for the most current product information.