GENERAL NOTES:

AA001
All dimensions are in millimeters (mm).
All levels and dimensions to be verified on site prior to the
2
7200 commencement of any work, and the Engineer to be notified in
case of any discrepancies.
3500 3700 All material and workmanship must comply with the latest SANS
code of practice.
345 850 378 1486 1475 1550 1116 The contractor is responsible for the correct setting out of the

18.00°
works, particularly boundaries, building lines, servitude's, etc.
A The contractor is to verify all levels, heights and dimensions on
site and to check against the drawings before commencing work.

1585
FOUNDATIONS:
The foundation wall shall protrude at least 150 mm above NGL.
Backfill with at least grade G5 material, compacted to 95% Mod
Wall Plate Level AASHTO density in layers of 150 mm thickness.

2700 B
C B

LOUNGE BATHROOM
3100

3100

3100
BEDROOM 1 SITE CONSTRUCTION NOTES

2700
1. DESCRIPTION TO BE ATTENDED BY THE ENGINEER
KITCHEN

2 2

Floor Level RC FLOOR SLAB 1 3

300 300
0
Foundation Level
7400

1334

-300

2200

8400
WC
450 x 250mm RC Strip foundation 2. DESCRIPTION TO BE ATTENDED BY THE CONTRACTOR
LOUNGE 600 x 300mm RC Strip foundation
(3Y10 spaced @150mm c/c with R10 (3Y10 @ 250mm c/c with R10 @
220mm c/c 600 x 300mm RC Strip foundation
2 stirrups @ 200mm c/c
(3Y10 spaced @150mm c/c with R10
1550

AA002 stirrups @ 200mm c/c)


4300

Section 1
AA001 3
1 AA001
2 1 : 50
BEDROOM 2
1416

3100
1000

345 1550 410 850 3450

Rev Description Date


3500 1075 1550 1075
4
3700

Floor Level
AA001

1 1 : 50

CODE SUITABILITY DESCRIPTION

STATUS PURPOSE OF ISSUE

{3D}
3 PROJECT

CONSTRUCTION NOTES (A-E GENERAL BUILDING WORKS)

A. ROOF SHEETING: min. of 0.53mm IBR widespan chromadek (green or similar) sheeting on a 50x76mm SA pine purlins

B. ROOF TRUSS: All roofs in accordance with SANS 10400 part L.


LOW COST FARM HOUSE
Grade 6 prefabricated timber (or similarapproved) Trusses at 18 degree max. 1200mm centres on 114mm x 38mm timber wall plates. Bottom chord use a 38x 152mm timber
Trusses to be tied down with 2 strands of 4mm galvanised roof wire anchors built into walls tied over a nail in purlins. CONSTRUCTION NOTES (1-3 GENERAL BULDIGNG WORKS)
Timber trusses - all exposed parts to be treated (painted) with creosote.
Matching tapperd barge boards (200mm x 15mm) to the gable ends and facia boards (150mm x 15mm) with 40mm serrated galvanized clouts nails. Barge and Facia boards to be painted to match plaster bands.
1. SURFACE BED : 25mm screed on a 100mm concrete surface bed on layer u.s.b green waterproofinhg sheeting on 150mm well compacted fill. TITLE
C. CEILING (As per Part L of SANS): 6.4mm thick gypsum ceiling board with 135mm thick aerolite fitted on 38x50mm roof purlins. SA pine brandering at 450mm c/c Provide a 650x650mm standard trap door. All ceiling
members to be painted white. 2. WALL: External walls to be 220mm stock brick or similar approved (min 7mpa) on 375 micro DPC.
Internal wall 110mm stock brick built into external walls.
D. FINISH: Provide medium duty, 2.8mm thick brickforce at every 4th course, as well as every course above windows and doors.
Horizontal DPC in external wall shall be to the same level as surface bed and 150mm above ground floor.
60 SQM HOUSE PLAN
Floor: Loft Steel (OLO120018A) 350 x 350mm ceramic tiles or similar with 8mm spacing. Grouting to be 'Progrip' Light Grey waterproof grout.
Walls: Plastered and painted with undercoat and 2 final coats SABS approved PVA paint. Where applicable provide SABS approved waterproofing to shower walls and floors.
Openings for waste pipes in wall to be neatly core drilled and not hammered or chisel opened.
E. ELECTRICAL: All electrical installation must be done by registered electrician/wireman. Installation to be as per SABS 0145. Conduits and wiring to walls to be chiseled 30mm into brickwork wall, make use of mesh Provide 120mm plaster band around windows and door openings.
before plastering the wall. Install a SABS and municipality approved prepaid electrical meter. All materials to be SABS approved. Plaster band should be painted contrasting colour to that of the wall.
Brick on edge window cills to be must be plastered.
F. PLUMBING: DIRECTORATE
Bath: 1700mm x 700 perspex type with hot and a mixer tap (not plastic taps), securely built into brick up stand support, silicone sealed all round vertical walls. bath to have 30x52mm waste pipe, an overflow drain 3. CONCRETE APRON: Cast a 700x75mm 25Mpa concrete apron with a 1:80 fall. 10mm thick expansion joint at 3m interval. Also allow for 10mm
outlet and a 300x300mm openable service hatch.
Wash hand Basin: Ceramic wash hand basin in bathroom with a min. diameter of 350mm, with a mixer tap. Silicone sealed at vertical walls and securely fixed to wall.
expansion joint at wall junction.
INFRASTRUCTURE SUPPORT
Legend 2
Water Cistern: Porcelain, 11 litres water capacity, complete with ball and beta valve flushing mechanism and flush pipe.
Water Closet: Glazed fire clay or porcelain fixed to floor with 1:3 cement mortar mixes. The seat to be heavy duty plastic type with flap and hinges or similar quality properly fixed to the pan.
Sink: 1 stainless steel sink with mixer tap to kitchen. Sink to be at least 900mm in length and securely fixed to wall with 2 brackets and silicone sealed against wall. DRAWN BY CHECKED BY DATE
1 : 50

2023/11/02 13:05:08
Supply Pipes: Class B galvanized pipe as per SABS 62 and 509 to be used as in feed pipe (external). Internally SABS plastic "Polycop" class 16 or similar approved.
All water feed pipes shall be chiseled 30mm into brickwork wall and make use of mesh before plastering wall. DIS DIS 10/31/23
G. GEYSER INSTALLATION: (As per Part XA of SANS) Geyser to comply with SAN 1307. Provide a 100 liter high pressure solar geyser system to be installed as per manufacture's specification SCALE (@ A1) PROJECT NUMBER
1 : 50 Project Number
Legend 1 DRAWING NUMBER REV

1 : 50 AA002