1a DC Power Pack
1a DC Power Pack
1a DC Power Pack
ADITYA ENTERPRISES
(AN ISO 9001:2008/CE CERTIFIED CO.)
STATIC RELAYS
AUTO MAINS FAILURE (AMF) RELAYS
MOTOR CONTROL RELAYS
ALARM / ANNUNCIATION SYSTEM
TRANSFORMERS
BATTERY CHARGERS
Aditya Enterprises was established in 2008 with a vision to provide high quality products & services to the customers.
It has also the ambi on to provide healthy atmosphere to work & grow its employees with its own growth. Company
has team of about 40 people & total working space is more than 3000 sq. .
Our Team :
In Aditya we have a high qualified ( B. Tech & Diploma ) team of Engineers with more than 15 years of experience in
industry in designing high quality & sophis cated products. Our produc on team has technicians with more than 10
years of experience in assembling & tes ng electronic equipments.
Aditya Enterprises is commi ed to provide best quality products & services to its customers as per agreed terms &
condi ons. In order to achieve this , we are con nually improving processes, products and services mee ng &
exceeding customer sa sfac on at all mes. To achieve our quality policy commitment we have appointed two quality
engineers to check the products technically & visually. Products are tested under different atmospheric condi ons like
high temp, under heavy vibra ng base etc. Aditya Enterprises possess the ISO 9000:2015 and CE cer ficates.
Director
Aditya Enterprises is involved in manufacturing high quality products widely used in Automa on,
Power Protec on and Control. Some of them are men oned below :
1.Voltage Monitoring Relays.
2.Current Monitoring Relays.
3.Reverse Power Protec on Relays.
4.Phase Sequence Correc on Relays.
5.Single Phasing & Reverse Phasing Protec on Relays.
6.Annuncia on Systems.
7.Ba ery Chargers.
8.Power Packs and many more.
Alarm Annunciators Aditya
ADITYA ENTERPRISES
(AN ISO 9001:2008/CE CERTIFIED CO.)
Panel Cutout: 69x139 mm Panel Cutout: 69x139 mm Panel Cutout: 69x139 mm Panel Cutout: 139x139 mm
Overall Size 72x144x140 mm Overall Size 72x144x140 mm Overall Size 72x144x140 mm Overall Size 144x144x140 mm
Panel Cutout: 189x92 mm Panel Cutout: 189x92 mm Panel Cutout: 189x92 mm Panel Cutout: 92X92 mm Panel Cutout: 92X92 mm
Overall Size 192X96X140 mm Overall Size 192X96X140 mm Overall Size 192X96X140 mm Overall Size 96X96X144 mm Overall Size 96X96X144 mm
Features :
• Powerful Microprocessor Based circuit.
• Special SMPS power supply.
• Sleek, modern, aesthetic design AE: 930
AE: 931 A AE: 931 AE: 932 AE: 930 AE: 933
PARAMETERS
Ordering Information Supply Voltage 12 / 24 / 48 / 110 / 220 V DC 110 / 240 V AC +10% –15% 24 V AC, 90 - 270 V AC / DC
•Model Name Windows 4 / 6 / 8 / 12 / 16
•No. of windows Display Device Super bright high efficiency low power consuming LED's
•Aux. Supply Window/LED Colour Standard colour available RED,
•Operation Sequence Flash Rate Fast - 60 flashes
•Optional Features Required Response Time 25 msec. ± 10 msec.
Output Contacts 2C/O, 1 NO for hooter
Contact Rating 5 Amps 240 V AC (Resistive)
Technical Specifications :
1. Supply Voltage : 24 Vdc+/-4V
2. No. of input Faults : 12 (Faults should be potential free)
3. Output Contact rating : 5A@230Vac.
4. Flashing Duty cycle : 1-1.2 sec.
5. Power consuption on stand by : 3VA max.
6. Power consuption on faults : 12VA max.
7. Insulation between output contacts & internal circuit :> 1 Mohm.
8. Size cutout : 139mm * 139mm
9. Physical size of the unit : 144mm(H)* 144mm(V)* 160mm(D)
General wiring diagram for Annunciator 12 Windows
Aditya
ADITYA ENTERPRISES
(AN ISO 9001:2008/CE CERTIFIED CO.)
STATIC RELAYS
AUTO MAINS FAILURE (AMF) RELAYS
MOTOR CONTROL RELAYS
ALARM / ANNUNCIATION SYSTEM
TRANSFORMERS
BATTERY CHARGERS
Size : 70 x 60 x 110 mm
Size : 13 x 6.75 x 9.5 Inch Size : 12 x5.5 x 8 Inch Size : 9.25 x 3.5 x 5.5 Inch Size : 9.25 x 3 x 5.5 Inch
Ba ery Chargers
Aditya Ba ery chargers are designed to bear voltage varia ons, fluctua ons & have low voltage
regula on.
Opera on : When the ba ery is connected & then provide input voltage 230Vac. It starts
charging the ba ery.
Aditya Transformers
While Charging : Aditya transformers are guaranteed for its best quality
Supply Indica on : ON, Charging Indica on : ON Whenever the ba ery gets fully charged along
core and original & pure copper winding.
with supply indica on & charging indica on ba ery full indica on also glows. Again when the
ba ery voltage goes below its rated voltage the ba ery full indicator switches off and ba ery
starts changing. Specs : as per customer requirement.
OVER CURRENT RELAY 3 Element over current AE530 REVERSE POWER RELAY FREQUENCY RELAY AE700
EARTH FAULT RELAY 3 Element 2OC / 1EF AE531 AE 800 SPEED RELAY AE
EARTH LEAKAGE RELAY
Earth Fault 0.2 - 2A Over Frequency 50 - 55 Hz
Over Current 0.5-5A AE 510 Over Current 0.5-5A SENSING Over Speed 1500 - 1650 rpm
Earth Fault 0.2-2A AE 520 Reverse Power - 6 - 10%
Earth Leakage 50-500mA AE 560 AE 530 series or Over current relays AE 700 series frequency relays
are ideal for sensing over current are used for protec on of
Aditya Current Single element Over faults in any or all phases for sensi ve equipment due to
current/ Earth Fault / Earth leakage protec on of AC machines, AE 800 series RPR relay monitors the
under or ment is being supplied
relays are ideal for sensing current Transformers, Generators etc. power flowing in the phases. The
faults in any one phase or earth for direc on of the power is checked. from a source whose frequency
The relay monitors the current
protec on of AC machines, passing in any feeder secondary. The The relay monitors current flowing in may be erra c. Can be used for
Transformers, Generators etc. The resultant current is digitally the B phase. This Current is squared tripping in case frequency goes
resultant current measured is compared. Each phase has its with the voltage in RY phase and above limit. A lower or higher
digitally compared to a se able independent se ng. Timer starts on motoring condi on detected. Power than limit condi on if persis ng
refernce. In case of trip condi on trip trip condi on and is common for all sensed is compared to a reference for more than 1 or 2 sec a contact
contacts changeover a er a se able three phases - a changeover occurs. and a mer is triggered above limit. changeover occurs and an led on
me of 1 - 10 sec. This can be used to Time must be set a according. Two Timer can be set 0-10 sec. Contacts
facia glows to indicate a trip
trip the breaker. Time must be set sets of changeover contacts are changeover occurs on meout and
according to system requirement. an led indica on signals closure. condi on. This can be used to
available - common for all.
Two changeover contacts are trip the breaker / supply. Two
available. sets of changeover contacts are
available. The relay is auto reset
type.
Size : 96 x 96 mm
Size : 144 x 72 mm
Cutout Size 138 x 68 mm
CYCLIC TIMERS AC AE 140 PUMP CONTROLLER PHASE SEQUENCE SINGLE PHASE PREVETOR
STAR DELTA TIMER AE 136 CORRECTOR RELAY AE 1100
Single Tank AE 1010 AE 400
Cyclic Timer Double tank AE 1020
ON 0.2 - 2 hrs
OFF Time 0.2 - 2 hrs Single tank pump controller is used to Used for protec on of motors,
Time can be provided as per monitor the overflow and / or pumps, transformers, etc from
Requirement prevent overflow as well as switch on damage due to missing phases or Single phase preventor is used for
pump when tank empty. Useful for nega ve phase sequences. A wrong protec on and burnouts of pumps
STAR DELTA single tank opera on of sequences is corrected and two and motors against phase
Star me 6 - 60 sec underground or overhead tank. output contacts are provided which unbalance, missing and nega ve
Double tank pump controller is used can be used to switch on the power phase sequence. All the phases are
Cyclic mers are used in cyclic to switch on pump when overhead contactors . Only the correct con nuously checked. A fault trip
opera on of two motors where tank is empty and shut of pump when sequence contactor signal will be on condi on trips the relay -
alternate pumping is required. Time overhead tank is full. Dry rum at a me. However contactors must changeover contacts are energized.
can be ordered as per requirement. protec on against underground tank be interlocked during power wiring. The relay resets automa cally and
Standard mes are 0.2 - 2 hrs is also provided. The relay resets automa cally and remains off when voltage is low
Separate changeover contacts for ON remains off when voltage is low, zero zero, unbalanced or nega ve phase
and OFF mes - Star Delta mers are unbalanced or nega ve phase sequence. Manual reset can be
used for star ng star delta motors. At sequence. Manual reset can be provided.
power on star connec on is made for provided.
selecable me a er which delta
connec on is made.
Size : 70 x 45 x 110 mm
Size : 70 x 100 x 110 mm
Size : 70 x 60 x 110 mm
Size : 70 x 60 x 110 mm
Authorised Dealer