Fixture Chart
Fixture Chart
OBJECTIONABLE TRAP
PIPE SIZES FIXTURE UNITS
FIXTURE TYPE
SUPPLY TRAP ARM VENT WSFU DFU
5 6
½” 3” 2” (Public) (Public)
or or or
12mm 76mm 51mm 3 4
(Private) (Private)
WATER CLOSET
(FLUSH TANK)
10 6
1” 3” 2” (Public) (Public)
or or or
25mm 76mm 51mm 6 4
(Private) (Private)
WATER CLOSET
(FLUSH VALVE)
4 6
½” 3” 2” (Public) (Public)
or or or
12mm 76mm 51mm 2.5 4
(Private) (Private)
WATER CLOSET
(ECONOMICAL FLUSH)
5 6
1” 3” 2” (Public) (Public)
or or or
25mm 76mm 51mm 3 4
(Private) (Private)
WATER CLOSET
(FLUSHOMETER TANK)
PIPE SIZES FIXTURE UNITS
FIXTURE TYPE
SUPPLY TRAP ARM VENT WSFU DFU
4
½” 1 ½” 2” (Public)
or or or 2
12mm 38mm 51mm 2
(Private)
BIDET
2
½” 1 ½” (Public)
or or 2
12mm 38mm 1
(Private)
LAVATORY
1
½” 1 ½” (Public)
or or 2
12mm 38mm 1
(Private)
LAVATORY
(DENTAL)
4
½” 1 ½” 1 ½” (Public)
or or or 2
12mm 38mm 38mm 2
(Private)
BATHTUB
PIPE SIZES FIXTURE UNITS
FIXTURE TYPE
SUPPLY TRAP ARM VENT WSFU DFU
5 (wall)
¾” 3” 1½”
or or or 5 (stall) 6
19mm 76mm 38mm
10(Pedestal)
URINAL
4
½” 1 ½” (Public)
or or 2
12mm 38mm 2
(Private)
KITCHEN SINK
2 2 (Public)
½” 1 ½” (Public)
or or
12mm 38mm 1 1
(Private)
(Private)
BAR SINK
4
½” 1 ½” (Public)
or or 2
12mm 38mm 2
(Private)
LAUNDRY SINK
PIPE SIZES FIXTURE UNITS
FIXTURE TYPE
SUPPLY TRAP ARM VENT WSFU DFU
4
¾” 1 ½” (Public)
or or 3
19mm 38mm 2
(Private)
SCULLERY SINK
10
½” 2” (Public)
or or 3
12mm 51mm 2
(Private)
SLOP SINK (SERVICE SINK)
1” 3”
or or 10 6
25mm 76mm
FLUSHING RIM
(CLINIC SINK)
2
½” 1 ¼” 1¼” (Public)
or or or 1
12mm 32mm 32mm 1
(Private)
DRINKING FOUNTAIN
PIPE SIZES FIXTURE UNITS
FIXTURE TYPE
SUPPLY TRAP ARM VENT WSFU DFU
4
½” 2” 1½” (Public)
or or or 2
12mm 51mm 38mm 2
(Private)
SHOWER BATH
2”
- or - 2
51mm
FLOOR DRAINS
5
½” 3” (Public)
or or - -
12mm 76mm 3
(Private)
HOSEBIBB
SHOWER RECEPTORS
- shall be constructed to have a finished dam, curb, or threshold of at least 25.4mm
(1”) lower than the outside floor.
DAM – Raised / Zocalo
CURB / THRESHOLD – Drop / Lowered
- Dam or threshold shall not be less than 51mm (2”) nor more than 228mm (9”) in
depth when measured from the top of the dam or threshold to the top of drain.
SHOWER DRAIN – MIN. 1200mm distance from the Bathroom entry / door.