• The flexoTHERM intelligent heat pump is available in 5, 8, 11, 15 and 19kW models
• Connects to three different sources - ground, water or air
• The quietest heat pump range in the UK with Sound Safe System
• Internet ready with remote monitoring available
• Green iQ for the highest energy efficiency
This information has been taken from our technical brochure, which is available from our web site
flexoTHERM exclusive technical specification sheet
Electrical data VWF 57/4 VWF 87/4 VWF 117/4 VWF 157/4 VWF 197/4
230V 230V 230V
Nominal voltage / rated voltage
- heating circuit / compressor V / Hz 1~/N/PE 230 / 50 2~/PE 230 / 50 3~/N/PE 400 / 50
- auxiliary heating V / Hz 1~/N/PE 230 / 50 2~/PE 230 / 50 3~/N/PE 400 / 50
Power factor cos φ = 0.75 – 0.9
Required network impedance Zmax with
Ω ≤ 0.472
inrush current limiter
Fuse type, caracteristic C, delay, three-
Designing in accordance with the selected
pole switching (interrupt of the three A 32
connection diagrams
power lines in one switching operation)
Optional building earth leakage circuit RCCB type A (type A pulse current sensitive residual-current circuit breakers) or
breaker RCCB type B (type B universal current sensitive residual-current circuit breakers)
Inrush currents - with initial current
A ≤ 15 ≤ 19 ≤ 60 ≤ 26 ≤ 30
limiter
Rated current (compressor + auxiliary
A 11.9 19.1 24.9 26.1 31.2
heater)
min. electrical power consumption of
kW 1.40 2.10 2.60 3.30 4.70
compressor
max. electrical power consumption of
kW 2.10 3.10 4.10 15.60 17.80
compressor
Protection class IP 10B
Hydraulic connection
Heating flow / return G 1 1/2”
Heat source flow / return G 1 1/2”
Central heating water expansion vessel G 3/4”
Heat source circuit / brine circuit
Volume of the brine circuit in the heat
l 2.5 3.1 3.6 4.5 5.3
pump
Materials of the brine circuit in the heat
Cu, CuZn-Alloy, Stainless Steel, EPDM, Brass, Fe
pump
min. pressure Brine liquid MPa (bar) ≥ 0,07 (≥ 0,7)
max. pressure Brine liquid MPa (bar) ≤ 0,3 (≤ 3 )
Heating circuit / building circuit
Water volume of the heating circuit in
l 3.2 3.9 4.4 5.8 6.5
the heat pump
Materials of the heating circuit Cu, CuZn-Alloy, Stainless Steel, EPDM, Brass, Fe
min. pressure MPa (bar) ≥ 0,07 (≥ 0,7)
max. pressure MPa (bar) ≤ 0,3 (≤ 3 )
min. flow temperature heating °C 25
max. flow temperature heating with
°C 65
compressor
min. flow temperature cooling °C 5
max. electrical power heating circuit
W 63 140
pump
Type of pump High efficiency
Refrigerant circuit
Refrigerant type R 410 A
Volume of refrigerant circuit in the heat
kg 1.50 2.40 2.50 3.05 3.95
pump
Global warming potential in accordance
2088
with (EU) No. 517/2014
CO2 equivalent t 3132 5011 5220 6368 8248
Global warming potential 100 (GWP100)
1975 1774
in accordance with (EU) No. 842/2006
Type expansion valve Electronic
Permissable pressure (relative) ≤ 4,6 (≤ 46,0)
Electrical data VWF 57/4 VWF 87/4 VWF 117/4 VWF 157/4 VWF 197/4
230V 230V 230V
Compressor type EVI Scroll
Oil type Ester (EMKARATE RL32-3 MAF)
Oil filling quantity 0.74 1.25 1.24 1.89
flexoTHERM Ground Source Heat Pump 35oC 40oC 45oC 50oC 55oC
flexoTHERM 5kW 230v 4.90 4.17 3.85 3.51 3.57
flexoTHERM 8kW 230v 4.67 4.12 3.78 3.50 3.63
flexoTHERM 11kW 230v 4.99 4.23 3.87 3.60 3.73
flexoTHERM 15kW 415v 5.39 4.61 4.23 3.89 3.74
flexoTHERM 19kW 415v 5.07 4.36 4.05 3.76 3.68
flexoTHERM with floCOLLECT water source 35oC 40oC 45oC 50oC 55oC
flexoTHERM 5kW 230v 4.94 4.41 4.02 3.87 3.87
flexoTHERM 8kW 230v 5.2 4.6 4.16 3.98 3.95
flexoTHERM 11kW 230v 5.22 4.63 4.19 4.03 4.02
flexoTHERM 15kW 415v 5.91 5.2 4.64 4.42 4.34
flexoTHERM 19kW 415v 5.63 4.97 4.46 4.27 4.23
flexoTHERM with aroCOLLECT (air source) 35oC 40oC 45oC 50oC 55oC
flexoTHERM 15kW 415v 4.51 3.91 3.46 3.37 3.42
flexoTHERM 19kW 415v 4.08 3.57 3.21 3.16 3.27