160-250kVA CPCBIV Genset
160-250kVA CPCBIV Genset
160-250kVA CPCBIV Genset
QSB6.7 Series
160 - 250 kVA, 128 - 200 kWe Prime
CPCB IV+ Emission Compliant
EATS Silencer
Hospital Grade Silencer inside canopy with rain cap
Single module architecture supplied by
suitably optimized to meet stringent noise limit
Cummins Emission Solutions.
Silencer specifically tuned to EATS
Compact design enabling optimized genset size
Integrated control module for engine and EATS
Best in class proven technology for meeting Mounting Arrangement
stringent emission norms
Engine and alternator are mounted on a common MS
fabricated base frame with AVM pads
Control Panel Skid mounted radiator
Base frame with integral fuel tank and DEF tank is provided
Control panel is powder coated for weather-proof and long-
with drain plug, air vent, inlet and outlet connection and
lasting finish. The control panel consists of the following parts:
provision for cleaning
PS0602 Controller
Bus bars with suitable capacity with incoming/ Optional
outgoing terminals
Indicating lamps for 'Load ON' and 'Set Running' Engine: Heated Architecture & HD Air cleaner
Instrument fuses duly wired and ferruled. Alternator: PMG and Space Heater
MCCB of suitable rating with short circuit protections EATS: Heated Architecture
AC/DC separation inside control panel for safety Controller: PCC3.3
Diesel Generator Set QSB6.7 Series Specification Sheet
Technical Data
Generator Set Specification
Technical Data
Model CI 160D5P CI 180D5P CI 200D5P CI 225D5P CI 250D5P
Engine Specification
Make Cummins®
Bore (mm) x Stroke (mm) 107 X 124 107 X 124 107 X 124 107 X 124 107 X 124
Fuel High Speed Diesel High Speed Diesel High Speed Diesel High Speed Diesel High Speed Diesel
Performance class of generator set ISO 8528-5 G2 ISO 8528-5 G2 ISO 8528-5 G2 ISO 8528-5 G2 ISO 8528-5 G2
Alternator Specification
Make STAMFORD (CGT) STAMFORD (CGT) STAMFORD (CGT) STAMFORD (CGT) STAMFORD (CGT)
Enclosure IP 23 IP 23 IP 23 IP 23 IP 23
Waveform distortion/ No load < 1.5%, Non distorting balanced linear load < 5 %
Total Harmonic Distortion
Maximum Unbalanced less than or equal to 25%
Load across phases•
• IS/IEC 60034-1
Prime Power (PRP):
• ISO 1460
Applicable for supplying power to
• ISO 8528
varying electrical load for unlimited hours.
• ISO 3046
Prime Power (PRP) is in accordance with
• ISO 9001
ISO 8528.
• ISO 13018
Bengaluru: Tel.: (080) 2325 9161 / 63, 2325 9165 / 67 | Fax: (080) 2325 9164
Authorised Representative
Chandigarh: Tel.: (0172) 224 0371-73 | Fax: (0172) 224 0372
Chennai: Tel.: (044) 2446 8110 / 2446 8113 | Fax: (044) 2491 1120
Gurgaon: Tel.: (0124) 391 0900-01 | Fax: (0124) 391 0916
Hyderabad: Tel.: (040) 2340 9970 / 2340 9980 | Fax: (040) 2340 9990
Jaipur: Tel.: (0141) 236 4944 | Fax: (0141) 403 8794
Kolkata: Tel.: (033) 2287 8065 / 2287 2481 | Fax: (033) 2290 3839
Lucknow: Tel.: (0522) 230 5049 / 230 5059 | Fax: (0522) 230 5035
Mohali: Tel.: (0172) 224 0371 I 72 / 73 | Fax: (0172) 224 0371 / 72 / 73
Vadodara: Tel.: (0265) 233 0627 / 3053627 | Fax: (0265) 234 0623