H F1 4 0F F(N EW ) MINIATURE INTERMEDIATE POWER RELAY

Features
File No.:E134517 ● 12A switching capability
● 5kV dielectric strength
(between coil and contacts)
File No.:R50149131 ● 1.5mm/2.0mm contact gap available
● Plastic sealed and flux proofed types available
● Sockets available
File No.:CQC10002046173 ● UL insulation system:Class F
● Environmental friendly product (RoHS compliant)

CONTACT DATA CHARACTERISTICS


Contact arrangement 2A, 2C Insulation resistance 1000M (at 500VDC)
Contact resistance 100m max.(at 1A 6VDC) Between coil & contacts 5000VAC 1min
Contact material AgSnO2 Dielectric Between contacts sets 3000VAC 1min
strength
Contact rating Between open contacts 2500VAC 1min
(Res. load) 12A/10A 250VAC,8A 30VDC
Surge voltage (between coil & contacts) 10kV (1.2/50 µs)
Max. switching voltage 250VAC / 30VDC Operate time (at nomi. volt.) 20ms max.
Max. switching current 12A Release time (at nomi. volt.) 5ms max.
Max. switching power 3000VA / 360W Humidity 5% to 85% RH
W(456) type: 3 x 105OPS
Mechanical endurance Ambient temperature -40 to 85
W type: 5 x105OPS
4 4 Functional 98m/s2
NO 3 x 10 OPS, NC 1 x 10 OPS Shock resistance
Destructive 980m/s2
(12A 250VAC,1s on 9s off)
Electrical endurance Vibration resistance 10Hz to 55Hz 1.5mmDA
3 x104ops
Termination PCB
(8A 30VDC,1s on 9s off) Unit weight Approx. 19g
Notes: 1) The data shown above are initial values. Plastic sealed,
2) For plastic sealed type, the venting-hole should be excised in Construction
Flux proofed
electrical endurance test.
Notes: 1) The data shown above are initial values.
2) Z type product Operate time ≤ 20ms.

SAFETY APPROVAL RATINGS COIL


12A 250VAC AC Resistive load 85
W type(1.5mm): Approx. 0.8W
1/3HP 125VAC NO/NC,40 Coil power
W type(2.0mm): Approx. 1.4W
UL
3/4HP 250/240VAC,NO,40
TV-5, 125VAC,40

TÜV 12A 250VAC AC Resistive load 85

CQC 12A 250VAC AC Resistive load 85

Notes: Only typical loads are listed above. Other load specifications can
be available upon request.

HONGFA RELAY
ISO9001, IATF16949 , ISO14001, ISO45001, IECQ QC 080000, ISO/IEC 27001 CERTIFIED 2023 Rev. 1.01

268
COIL DATA at 23
W Type (1.5mm) W Type (2.0mm)

Nominal Pick-up Drop-out Max. Coil Nominal Pick-up Drop-out Max.


Voltage Voltage Voltage Allowable Resistance Voltage Voltage Voltage Allowable
VDC VDC Voltage VDC VDC Voltage
VDC VDC
max. min. VDC max. min. VDC
3 ≤2.25 ≥0.3 3.3 11.3 x (1 10%) 3 ≤2.25 ≥0.3 3.3 6x (1 10%)

5 ≤3.75 ≥0.5 5.5 31 x (1 10%) 5 ≤3.75 ≥0.5 5.5 18 x (1 10%)

6 ≤4.5 ≥0.6 6.6 45 x (1 10%) 6 ≤4.5 ≥0.6 6.6 26 x (1 10%)

9 ≤6.75 ≥0.9 9.9 101 x (1 10%) 9 ≤6.75 ≥0.9 9.9 58 x (1 10%)

12 ≤9 ≥1.2 13.2 180 x (1 10%) 12 ≤9 ≥1.2 13.2 102 x (1 10%)

15 ≤11.25 ≥1.5 16.5 280 x (1 10%) 15 ≤11.25 ≥1.5 16.5 160 x (1 10%)

18 ≤13.5 ≥1.8 19.8 405 x (1 10%) 18 ≤13.5 ≥1.8 19.8 230 x (1 10%)

24 ≤18 ≥2.4 26.4 720 x (1 10%) 24 ≤18 ≥2.4 26.4 410 x (1 10%)

36 ≤27 ≥3.6 39.6 1620x (1 10%) 36 ≤27 ≥3.6 39.6 925x (1 10%)

48 ≤36 ≥4.8 52.8 2880 x (1 10%) 48 ≤36 ≥4.8 52.8 1650 x (1 10%)

60 ≤45 ≥6 66.0 4500 x (1 10%) 60 ≤45 ≥6 66.0 2570 x (1 10%)

110 ≤82.5 ≥11 121.0 15100 x (1 10%) 110 ≤82.5 ≥11 121.0 8068 x (1 10%)
Notes:1) The data shown above are initial values.
2) Maximum voltage refers to the maximum voltage which relay coil could endure in a short period of time.
3) In order to meet the stated product performance, please apply rated voltage to coli.
4) Maximum voltage refers to the maximum voltage which relay coil could endure in a short period of time.
5) For the CO version whose contact gap is 1.5 mm/2.0mm, the operation voltage ≤85% of rated voltage,the coil resistance tolerance is (1±15%).

ORDERING INFORMATION

HF 1 4 0F F / 0 1 2 -2 H S W T G F (XXX)
Type
3, 5, 6, 9,12,15,18,24,
Coil voltage
36,48, 60,110VDC

Contact arrangement 2H: 2 Form A 2Z: 2 Form C

Construction S: Plastic sealed Nil: Flux proofed

Contact Gap W: Large contact gap

Contact material T: AgSnO2

Contact plating G: Gold plated Nil: No gold plated

Insulation standard F: Class F Nil: Class F

Special code XXX: Customer special requirement Nil: Standard


Notes:1) We recommend flux proofed types for a clean environment (free from contaminations like H2S, SO2, NO2, dust, etc.).
We suggest to choose plastic sealed types and validate it in real application for an unclean environment (with contaminations like H2S,
SO2, NO2, dust, etc).
2) Contact is recommended for suitable condition and specifications if water cleaning or surface process is involved in assembling relays
on PCB.
3) There are two specifications to W type: 1.5mm contact gap and 2.0mm contact gap.The default W type is 1.5mm. So please add the
special code "(456)" when releasing order,if 2.0mm contact gap is required.
4) The customer special requirement express as special code after evaluating by Hongfa. e.g.(456) means contact gap can reach 2.0mm.

269
OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT Unit: mm

Outline Dimensions

2 Form A PCB Layout (Bottom view) Wiring Diagram (Bottom view)


29 12.7
20
5 2.15

+0.1
6xØ1.3 0

0.4 X1(2 location)

0.5 X1.0(4 location)

20
5

2 Form C PCB Layout (Bottom view) Wiring Diagram (Bottom view)

29 12.7
20
5 5 2.15

8x Ø1.3 +0.1
0

0.4 X1(2 location)


0.5 X1.0(6 location)

20
5 5

Remark: 1) The pin dimension of the product outline drawing is the size before tinning (it will become larger after tinning), and the mounting hole
size is the recommended design size of the PCB board hole. The specific PCB board hole design size can be mapped and adjusted
according to the actual product.
2) In case of no tolerance shown in outline dimension: outline dimension ≤1mm, tolerance should be ±0.2mm; outline dimension >1mm
and ≤5mm, tolerance should be ±0.3mm; outline dimension >5mm, tolerance should be ±0.4mm.
2) The tolerance without indicating for PCB layout is always ±0.1mm.
3) The width of the gridding is 2.5mm.

270
CHARACTERISTIC CURVES

EN DU RA N CE C URV E

10 6

NO(COSΦ=0.4)

10 5
NO(COSΦ=1)

NC(COSΦ=1)
NC(COSΦ=0.4)

10 4

0 2 4 6 8 10 12

Current(A)

250VAC resistive load/switching current

Disclaimer
The specification is for reference only. See to "Terminology and Guidelines" for more information. Specifications subject to change without notice.
We could not evaluate all the performance and all the parameters for every possible application. Thus the user should be in a right position to
choose the suitable product for their own application. If there is any query, please contact Hongfa for the technical service. However, it is the user’s
responsibility to determine which product should be used only.

© Xiamen Hongfa Electroacoustic Co., Ltd. All rights of Hongfa are reserved.

271

You might also like