0% found this document useful (0 votes)
56 views4 pages

Data Sheet VE 100 - En3

Uploaded by

Manoj Kumar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
56 views4 pages

Data Sheet VE 100 - En3

Uploaded by

Manoj Kumar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Engineering office for vibration technology, consulting and advanced training

----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

Data sheet
Portable 3 channel analyzer VE 100

- Real-time frequency analysis


- Envelope analysis
- Order analyses
- automatic speed recognition
- Tacho / Trigger Input
- built-in LED stroboscope
- contactless thermometer
- Colour TFT display with 240 x 320 resolution
- linearization for vibration velocity sensors (VS080)
- Frequency range up to 90kHz

Description

The VE 100 portable vibration meter is the latest type of portable instrument on the vibration diagnosis market. It is a
powerful tool for every maintenance engineer, service technician and after sales technician who faces vibration problems on
rotating machines, motors and equipment.

The design offers 3 signal inputs (AC/DC) and 1 separate tachometer (trigger input). The second channel has the possibility
to use a triaxial sensor, so that all 3 channels can be measured simultaneously. Frequency analyses (FFT) are determined
in real time. Measurements can be displayed in acceleration, vibration velocity or displacement on the clearly arranged
colour display. In addition, there is a non-contact IR temperature sensor (for immediate storage temperature measurement)
and an LED stroboscope / flashlight.

The VE 100 is designed for one-handed operation with a weight of only 800 g and a battery life of more than 8 hours. This
makes it suitable for measurements over long distances over the entire working day. Due to the synchronized trigger input,
the VE 100 is ideally suited for balancing in one or two planes as well as determining order analyses.
The expert system can automatically detect machine errors according to ISO 10816-3 such as unbalance, loosening (tilt
foot), misalignment and bearing errors. Depending on the selected machine category and the corresponding alarm value,
the measured vibration level is displayed in the traffic light colours green (normal), yellow (alarm) and red (danger).

The VE 100 also offers ultrasonic measurements. Typical applications are the detection of air leaks, electric arcs or the early
detection of bearing damage.

An 8GB internal memory provides enough storage of the measured data when collecting data in the field. The device makes
the data available via USB stick function on current Windows systems and enables easy data exchange for the diagnosis
and evaluation software VE-DC.

The VE 100 instrument can be configured beside the standard modules:

- Fast Check (meter)


- Expert system Diagnostic
- Stroboscope
- Analyzer or Balancer or Collector

according to your requirements by choosing optional modules:

Page 1 from 4
E-Mail: [email protected] Web: www.vibroengineering.de
Engineering office for vibration technology, consulting and advanced training
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

- FFT- Analyzer
- Balancer
- Data collector
- Tracking
- Ultrasound
- Time signal recorder

Optional modules can be purchased also additionally and downloaded to the instrument without the need of sending it back
to the factory.

Technical Data:

General
Processor: ARM Cortex A8
RAM: 1 GB
Display: TFT colour 117 x 88 mm (3.5’’ diagonal), 240x320
resolution
Data Memory: 8 GB (Flash)
Interface: USB 2.0, 3.0 compatible
Powering: Li-Ion battery pack (more than 8 hours of
measurement)
Operating temperature: -10 °C - +50 °C, 15°F-120°F
Case: industrial aluminum
Dimensions: 240 x 85 x 35 mm,
Weight: 800g
Flashlight: Yes
Languages: actual: English, German, (French)

Inputs

Dynamic Channels (AC)


Number of synchronous parallel channels (AC): 3 AC
Frequency range (-3dB): 0.5 - max 90000 Hz*
(196608 Hz sampling frequency)

Input range: +/- 12V (only one range, no gain)


Measurement timing: fully synchronous
A/D Resolution: 24 bit input, 64 bit double floating point
(no gain procedures used!)
Dynamic range: 120 dB
Channel configuration: voltage or ICP (individually every channel)
Input protection: up to 28 V
Input impedance: 100 kOhm
Input type: Acceleration, velocity, displacement, any non-
vibration AC voltage
Integration: single or double fully digital integration
2D Processing: axis rotation according sensor mounting
Accuracy: < 0.5 %
ICP / CCS drive: 18 V, 3.8 mA
User HP filtering: 0.5Hz - 12800 Hz
User LP filtering: 25Hz - 90000 Hz*
Connector: robust Push-Pull system

Tacho / Speed Channel


Number: 1 independent tacho input
Speed range: 0.5 Hz - 1000 Hz (more possible)
Input impedance: 55 kOhm
Input type: voltage
Input range: +/-30 V

Page 2 from 4
E-Mail: [email protected] Web: www.vibroengineering.de
Engineering office for vibration technology, consulting and advanced training
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

Accuracy: <0.5 %
Trigger level: 0.1 V - 9.9 V, user defined
Input protection: up to 48 V
Connector: robust Push-Pull system

Static Channels (DC)


Number: 3 DC
Input range: +/- 24 V
Input impedance: 100kOhm (V-DC)
A/D Resolution: 12bit input
Accuracy: 0.1% fsd
Input protection: up to 28 V

Measurement Functions
Data Analysis Speed: 0.1 sec for 25600 lines FFT spectrum
Amplitude Units: Metric, Imperial (English) or EU
Frequency Units: Hz, CPS, RPM, CPM, Orders

Amplitude scale: Acceleration, Velocity, Displacement, User defined

Scaling: Linear or Log, both X and Y axes


Cursor: Single

Triggering: free run, tacho, amplitude (positive or negative),


external (voltage)
Signal Range: full, No Auto ranging

Data acquisition: true rms, true peak, true peak-peak, overall or band
values, user defined high, low and band pass filters
for band measurement
time waveforms (196608 samples max)*
real-time FFT
order analysis
Amplitude + phase values on speed frequency
speed measurement
process static DC
Envelope demodulation
ACMT procedure for low speed machines bearings
Time waveform samples: 256 – 196608
Waveform (ACMT) length: max 1024 sec
Spectrum ranges: 25 Hz – 90000 Hz
Spectrum lines: 100 – 25 600
Spectrum units: RMS, P and P-P
Windows: Hanning
Order analysis parameters: 1/2 - 10th order
Averaging: 1-255
Overlap: yes
*only for one channel

Stroboscope
Frequency Range: 1 Hz – 111 Hz (60 RPM – 6660 RPM)
Stroboscope Frequency: User defined / Externally triggered

Temperature
Temperature Measurement: Yes
Temperature Measurement Type: Infrared
Temperature Range: -70 °C – 380 °C (-94 °F – 716 °F)

Page 3 from 4
E-Mail: [email protected] Web: www.vibroengineering.de
Engineering office for vibration technology, consulting and advanced training
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

SAFEGUARDS AND PRECAUTIONS:

Read and follow all instructions in the manual portable analyzer VE 100 carefully and retain this sheet
for future reference.

Do not use this instrument in any manner inconsistent with these operating instructions or under any
conditions that exceed the environmental specifications stated. This instrument is not user
serviceable. For technical assistance, contact the sales organization from which you purchased the
product.

In order to comply with EU Directive 2012/19/EU on Waste Electrical and Electronic


Equipment (WEEE):
This product may contain material which could be hazardous to human health and the
environment. DO NOT DISPOSE of this product as unsorted municipal waste. This product
needs to be RECYCLED in accordance with local regulations, contact your local authorities
for more information. This product can be returned to your dealer for recycling - contact the
dealer for more information.

CE compliant. RoHS compliant. Meets the safety requirements of EN 55022, CISPR 22, EN 55011
EN 61000-6-1
This product is not waterproof.

This product is not user serviceable.


Please contact VIBROEngineering for technical support!

Ingenieurbüro für Schwingungstechnik, Beratung und Fortbildung

VIBROEngineering
Weschnitzstraße 4
64625 Bensheim
Germany

Page 4 from 4
E-Mail: [email protected] Web: www.vibroengineering.de

You might also like