Ul MCCB
Ul MCCB
Ul MCCB
BQ Breakers
Selection and ordering data 240V BQ BQH HBQ 10KAIC 22KAIC 65KAIC
QJ Breakers
Selection and ordering data 240V QJ2 QJH-2 QJ2-H HQJ2-H 10KAIC 22KAIC 42KAIC 100KAIC
CQD Breakers
Selection and ordering data 480V CQD 14KAIC CQD-6 600/347V 10KAIC
1-, 2- & 3-pole up to 125A for circuit protection up to 240 volt circuits (UL) Information General Data Accessories Page 17/917/10 17/10317/108
2- & 3-pole up to 225A for circuit protection up to 240 volt circuits (UL) Information General Data Accessories Page 17/11 17/10317/108
1-, 2- & 3-pole up to 100A for circuit protection up to 600/347V (CSA) & 480/277V (UL) circuits Information General Data Internal Accessories External Accessories Page 17/12 17/14 17/10317/108
NGG Breakers
Selection and ordering data 480V NGG 25KAIC 600/347V 14KAIC
DG VL Breakers
Selection and ordering data 480V NDG HDG LDG 35KAIC 65KAIC 100KAIC 600V 18KAIC 20KAIC 25KAIC
FG VL Breakers
Selection and ordering data 480V NFG HFG LFG 35KAIC 65KAIC 100KAIC 600V 18KAIC 20KAIC 25KAIC
1-, 2- & 3-pole up to 125A for circuit protection up to 600/347 volt circuits (UL/CSA/IEC) Information General Data Internal Accessories External Accessories
Siemens Industry, Inc. Industrial Controls Catalog
2- & 3-pole up to 150A for circuit protection up to 600 volt circuits (UL/CSA/IEC) Information Breakers & Trip Units Internal Accessories External Accessories Page 17/1717/19 17/23 17/4317/57
2- & 3-pole up to 250A for circuit protection up to 600 volt circuits (UL/CSA/IEC) Information General Data Internal Accessories External Accessories Page 17/2017/22 17/23 17/4317/57
17/1
JG VL Breakers
Selection and ordering data 480V NJG HJG LJG 35KAIC 65KAIC 100KAIC 600V 25KAIC 25KAIC 25KAIC
LG VL Breakers
Selection and ordering data 480V NLG HLG LLG 35KAIC 65KAIC 100KAIC 600V 25KAIC 25KAIC 25KAIC
MG VL Breakers
Selection and ordering data 480V NMG HMG LMG 35KAIC 65KAIC 100KAIC 600V 25KAIC 35KAIC 50KAIC
2- & 3-pole up to 400A for circuit protection up to 600 volt circuits (UL/CSA/IEC) Information General Data Internal Accessories External Accessories Page 17/2417/26 17/30 17/4317/57
2- & 3-pole up to 600A for circuit protection up to 600 volt circuits (UL/CSA/IEC) Information General Data Internal Accessories External Accessories Page 17/2717/29 17/30 17/4317/57
2- & 3-pole up to 800A for circuit protection up to 600 volt circuits (UL/CSA/IEC) Information General Data Internal Accessories External Accessories Page 17/3117/33 17/39 17/4317/57
Page
17/117/4 17/517/8 17/1517/16 17 /4 0 17/41 17/42 1 7/ 58 17/59 1 7/ 60 1 7 / 61 17/62 17/110 1 7 / 11 1
NG VL Breakers
Selection and ordering data 480V NNG HNG LNG 35KAIC 65KAIC 100KAIC 600V 25KAIC 35KAIC 65KAIC
PG VL Breakers
Selection and ordering data 480V NPG HPG LPG 35KAIC 65KAIC 100KAIC 600V 25KAIC 35KAIC 65KAIC
4 0 0 Hz S y st em s
2- & 3-pole up to 1200A for circuit protection up to 600 volt circuits (UL/CSA/IEC) Information General Data Internal Accessories External Accessories Page 17/3417/36 17/39 17/4317/57
2- & 3-pole up to 1600A for circuit protection up to 600 volt circuits (UL/CSA/IEC) Information General Data Internal Accessories External Accessories Pa ge 17/3717/38 17/39 17/4317/57
Siemens Industry, Inc. Industrial Controls Catalog
17/2
Sentron ED Breakers
Selection and ordering data 240V ED2 ED4 ED6 10KAIC 65KAIC 65KAIC 480V 18KAIC 25KAIC 600V 18KAIC
Sentron FD Breakers
Selection and ordering data 480V FD6 HFD6 HHFD6 CFD6 35KAIC 65KAIC 100KAIC 200KAIC 600V 22KAIC 35KAIC 25KAIC 100KAIC
1-, 2- & 3-pole up to 125A for circuit protection up to 600 volt circuits (UL/CSA/IEC) Information General Data Internal Accessories External Accessories Page 17/63 17/65 17/10317/108
1-, 2- & 3-pole up to 125A for circuit protection up to 600 volt circuits (UL/CSA/IEC) Information General Data Internal Accessories External Accessories Page 17/64 17/65 17/10317/108
2- & 3-pole up to 250A for circuit protection up to 600 volt circuits (UL/CSA/IEC) Information General Data Internal Accessories External Accessories Page 17/6617/67 17/68 17/10317/108
Sentron JD Breakers
Selection and ordering data
240V JD2 JD6, SJD6-A HJD6, SHJD6-A HHJD6 CJD6, SCJD6-A 65KAIC 65KAIC 100KAIC 200KAIC 200KAIC 480V 35KAIC 65KAIC 100KAIC 150KAIC 600V 25KAIC 35KAIC 50KAIC 100KAIC
Sentron LD Breakers
Selection and ordering data 480V LD6, SLD6-A HLD6, SHLD6-A HHLD6 CLD6, SCLD6-A 35KAIC 65KAIC 100KAIC 150KAIC 600V 25KAIC 25KAIC 50KAIC 100KAIC
2- & 3-pole up to 400A for circuit protection up to 600 volt circuits (UL/CSA) Information General Data Internal Accessories External Accessories
Siemens Industry, Inc. Industrial Controls Catalog
2- & 3-pole up to 600A for circuit protection up to 600 volt circuits (UL/CSA) Information General Data Internal Accessories External Accessories Page 17/7217/74 17/77 17/10317/108
2- & 3-pole up to 800A for circuit protection up to 600 volt circuits (UL/CSA) Info rmat ion General Data Internal Accessories External Accessories Page 17/7517/76 17/77 17/10317/108
17/3
Sentron MD Breakers
Selection and ordering data 480V MD, SMD6 HMD, SHMD6 CMD, SCMD6 50KAIC 65KAIC 100KAIC 600V 25KAIC 50KAIC 65KAIC
Sentron ND Breakers
Selection and ordering data 480V ND, SND6 HND, SHND6 CND, SCHD6 50KAIC 65KAIC 100KAIC 600V 25KAIC 50KAIC 65KAIC
Sentron PD Breakers
Selection and ordering data 480V PD, SPD6 HPD, SHPD6 CPD 50KAIC 65KAIC 100KAIC 600V 25KAIC 50KAIC 65KAIC
2- & 3-pole up to 800A for circuit protection up to 600 volt circuits (UL/CSA) Information General Data Internal Accessories External Accessories Page 17/7817/80 17/87 17/10317/108
2- & 3-pole up to 1200A for circuit protection up to 600 volt circuits (UL/CSA) Information General Data Internal Accessories External Accessories Page 17/8117/83 17/87 17/10317/108
2- & 3-pole up to 1600A for circuit protection up to 600 volt circuits (UL/CSA) Information General Data Internal Accessories External Accessories Page 17/8417/85 17/87 17/10317/108
Page
17/117/4 17/517/8 17/8817/90 17/9117/93 1 7/ 9 4 17/95
Sensitrip III Electronic Trip Breakers 17/9617/97 1 7/ 9 8 1 7 / 9 9 17/10017/102 17/109 17/110 17/112
Sentron RD Breakers
Selection and ordering data 480V RD HRD 50KAIC 65KAIC 600V 25KAIC 50KAIC
2- & 3-pole up to 2000A for circuit protection up to 600 volt circuits (UL/CSA) Information General Data Internal Accessories External Accessories Page 17/86 17/87 17/10317/108
Siemens Industry, Inc. Industrial Controls Catalog
17/4
Ordering
In the FD through RD frames, you may order molded case circuit breakers three basic ways: As separately ordered frames, trip units and lugs As frame, trip unit and lugs ordered as one catalog number and shipped unassembled or assembled As Frame and Trip Unit shipped assembled and with the trip unit made non-removable, in compliance with UL 489 requirements that to be reverse fed the circuit breaker must not have an interchangeable trip unit. These two options are described in the following: Components Ordered Separately To get the components for a 3-pole, 400 Amp standard interrupting circuit breaker, you would order the frame (JD63F400), the trip unit (JD63T400) and six lugs (TA2J6500). This option is normally useful only if you stock and use large volumes of product and wish to reduce your inventory cost. You may stock, for example, a smaller number of frames (JD63F400) and a variety of trip units (JD63T300, JD63T350, etc.) and assemble breakers as you need them. Frame, Trip Unit and Lugs Ordered Together If you order the catalog number JD63B400, you will receive a frame, a trip unit and 6 lugs in separate packages. By suffixing this number with L (e.g. JD63B400L), you will receive frame, trip unit and lugs assembled in one container. Pursuant to UL 489, a product ordered thus will have the markings LINE and LOAD, and may not be reverse fed (with power flowing from the OFF end of the breaker toward the ON end). Non-Interchangeable Trip Breakers If you place an X after the frame size designator (e.g. JXD63B400), you will receive a frame and trip unit assembled, with the trip unit made non-removable. If you suffix an L to this catalog number (e.g. JXD63B400L), you will receive the breaker, non-removable trip unit and lugs assembled. Unless you anticipate a specific need to change the breaker's ampere rating in the future, this is the preferred ordering method, as the products are assembled to Siemens' specifications in our factories. These breakers are suitable for use reverse fed according to UL 489, since the trip unit is not removable.
The smaller frames (QJ, ED and below) do not have removable trip units, and consequently are shipped only as assembled products. To add lugs, see the ordering instructions on each product's catalog page.
17/5
Interrupting Class N Normal H High L Very High C Trip Unit Only Frame Family G Type GG D Type DG F Type FG J Type JG L M N P Type LG Type MG Type NG Type PG
Breaker Type G Global (UL, IEC, CE, CSA, NOM) M Motor Circuit Protector T Trip Unit Only (Global) S Molded Case Switch X Non-Interchangeable J 240V only rated, Non-interchangeable only Y 100% rated, Non-interchangeable Number of Poles 1, 2, 3, 4, 5 (4P w/ neutral protection) Trip Unit B Thermal Magnetic, standard 40 C ambient C Thermal Magnetic, calibrated for 50 C ambient (non-UL) D Electronic w/ LCD, LSI or 3P (neutral protected) E Electronic w/ LCD, LSIG, 3P/4W (selectable residual or return type ground fault protection) F Frame only, without trip unit H Magnetic only, Motor Circuit Protector - High instantaneous range L Magnetic Only, Motor Circuit Protector - Low instantaneous range M Magnetic Only, Motor Circuit Protector - Standard instantaneous range N Electronic LI or 3P (neutral protected) P Electronic LSI or 3P (neutral protected) S Molded Case Switch U Electronic, LSIG or 3P/4W, residual ground fault protection X Electronic, LIG or 3P/4W, residual ground fault protection
Continuous Current Rating For GG use 015, 020, 025, 030, 035, 040, 050, 060, 070, 080, 090, 100, 110, 125 For DG use 050, 060, 070, 080, 090, 100, 110, 125, 150 For FG use 100, 110, 125, 150, 175, 200, 225, 250 For JG use 250, 300, 350, 400 For LG use 400, 500, 600 For MG use 600, 700, 800 For NG use 800, 900, 100 (1000A), 120 (1200A) For PG use 120 (1200A), 140 (1400A), 160 (1600A) Terminations B Load End Standard (cu/al) Lugs L Line & Load Standard (co/al) Lugs X No Lugs (use only if accessory suffixes are to follow) Accessories Auxiliary and Alarm Switch Combinations Suffix Description A1 1 Alarm (includes 1NO & 1NC switch with a 2 Aux./1 Alarm Base, for frames DG to JG) A2 2 Aux (1NO & 1NC switch with a 3 Aux. Base, for frames DG to JG) A3 2 Aux + 1 Alarm (2NO & 2NC switches with a 2 Aux./1 Alarm Base, for frames DG to JG) A3 2 Aux + 2 Alarm (2NO & 2NC switches with a 2 Aux./2 Alarm Base, for frames LG to PG) A4 4 Aux (2NO & 2NC switches with a 4 Aux. Base, for frames LG to PG) Shunt Trips RB 24 VDC RM 48-60 VAC RC 48-60 VDC RN 110-127 VAC RD 110-127 VDC RS 208-277 VAC RE 250 VDC RV 380-600 VAC Under Voltage Releases UA 12 VDC UN UB 24 VDC UP UC 48 VDC UR UD 110-127 VDC US UE 220-250 VDC UT UG 60 VDC UU UK 24 VAC UV 110-127 VAC 208 VAC 220-250 VAC 277 VAC 380-415 VAC 440-480 VAC 600 VAC
Note: A1 and A3 include 1NO and 1NC switch for alarm purposes, only one of these switches may be used as there is only one space for an alarm.
LCD = Liquid Crystal Display LS = Long Delay & Short Delay trip functions LSI = Long Delay, Short Delay, & Instantaneous trip functions LSIG = Long Delay, Short Delay, Instantaneous, & Ground Fault trip functions GF = Ground Fault 3P = 3-pole 4W = 4-wire
17/6
If ordering factory-installed accessories or special modifications, you must order a 15-digit catalog number. See the examples below for a detailed explanation. The 15 digit number is achieved by placing Xs in positions not being occupied by an accessory/modification. Auxiliary Switch Example:
HFG3B200L A2 XXXX
Standard 9-digit Aux. Switch Completes Cat #
HFG3B200L XX UN XX
Standard 9-digit UVR Completes Cat #
HFG3B200L A2 RN XX
Standard 9-digit Aux. Switch Shunt Completes Trip Cat #
HFG3B200L XXXX Z1
Standard 9-digit Completes Cat # Custom Mod.
These places could designate an enclosure or special modification. Siemens will define the factory modification suffixes.
HFX3B200L
Standard 9-digit
17/7
If used on 250A frame and above means non-interchangeable trip breaker with factory assembled frame and trip. Solid state trip and current limiting (S or C in first character) are non-interchangeable only, and the X is omitted.
X D
Trip Unit Type Omitted Thermal-Magnetic S Sensitrip Electronic Trip Sentron Series Type/Interrupting Range Omitted Standard Rating H High IC Rating HH Extra High IC Rating C Highest IC Rating and Current Limiting Frame Identifier E Type ED F Type FD J Type JD L Type LD LM Type LMD Maximum Voltage 2 240 Vac 4 480 Vac 6 600 Vac Number of Poles 1 2 3 9 used to indicate the max. functions for an electronic trip circuit breaker (always 3 poles) (Specific Application Type) B Standard 40C Breaker M Calibrated for 50C Application F Frame Only T 40C Trip Unit Only W 50C Trip Unit Only S Molded Case Switch L Low Instantaneous Range ETI Breaker A Standard Range ETI Breaker H High Instantaneous Range ETI Breaker Maximum Continuous Current Rating ED Frame 015, 020, 025, 030, 035, 040, 045, 050, 060, 070, 080, 090, 100, 110, 125 FD Frame 070, 080, 090, 100, 110, 125, 150, 175, 200, 225, 250 JD Frame 200, 225, 250, 300, 350, 400 LD Frame 250, 300, 350, 400, 450, 500, 600 LMD Frame 500, 600, 700, 800 MD Frame 500, 600, 700, 800 ND Frame 900, 100 (1000A), 120 (1200A) PD Frame 120 (1200A), 140 (1400A), 160 (1600A) RD Frame 160 (1600A), 180 (1800A), 200 (2000A) TD Frame 2000, 2500, 3200 Suffix L where applicable indicates a breaker shipped with line/loads lugs installed A used with a switch to show automatic self protection Y 400 Hertz H 100% rated P Load side lugs only NOTE: Position omitted if not used. M N P R T Type Type Type Type Type MD ND PD RD TD
17/8
All BQ/BQH/HBQ circuit breakers are supplied with load side lugs. If line side lugs are required, add suffix L to catalog number. Consult Siemens for any additional charge. All standard circuit breakers are calibrated for 40C maximum ambient application.
1-Pole
2-Pole
3-Pole
Factory Modifications
Description Line Side Lugs Quick Connect Lug 400Hz Calibration 415V 50Hz Calibration Marine 50 C Ambient Calibration Fungus Proofing Catalog Number add suffix...L add suffix...QX add suffix...Y add suffix...E add suffix...M add suffix...F List Price $ Consult Siemens (adder per pole) (adder) No adder No adder (adder per pole)
Built to order. Allow 2-3
weeks for delivery
UL Listed for use with 60/75 wire through 125 amps, HACR rated. 1A and 1B contacts. UL Listed for use on 3-phase grounded B systems 10,000 for this application.
UL Listed for frequent switching applications (SWD). 120V AC Fluorescent Lighting. Shipped 12 per sleeve. Shipped 6 per sleeve. Shipped 4 per sleeve.
17/9
Interrupting Ratings (KA) (RMS Symmetrical Amperes) Volts AC Breaker Type BQXD 1-Pole 120V DIN Rail Ampere Rating 10 15 20 25 30 35 40 45 50 60 10 15 20 25 30 35 40 45 50 60 Catalog Number BQ1B010QLD BQ1B015QLD BQ1B020QLD BQ1B025QLD BQ1B030QLD BQ1B035QLD BQ1B040QLD BQ1B045QLD BQ1B050QLD BQ1B060QLD BQ1B010QXD BQ1B015QXD BQ1B020QXD BQ1B025QXD BQ1B030QXD BQ1B035QXD BQ1B040QXD BQ1B045QXD BQ1B050QXD BQ1B060QXD Load Side Connector TC1Q1 TC1Q1 TC1Q1 TC1Q1 TC1Q1 TC1Q1 TC1Q1 TA1Q1 TA1Q1 TA1Q1 Quick-Connect Quick-Connect Quick-Connect Quick-Connect Quick-Connect Quick-Connect Quick-Connect Quick-Connect Quick-Connect Quick-Connect TC1Q1 TC1Q1 TC1Q1 TC1Q1 TC1Q1 TC1Q1 TC1Q1 TA1Q1 TA1Q1 TA1Q1 Quick-Connect Quick-Connect Quick-Connect Quick-Connect Quick-Connect Quick-Connect Quick-Connect Quick-Connect Quick-Connect Quick-Connect List Price $ 120 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 120/240
BQ1B015QLD
BQ2B015QLD
10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10
BQ1B015QXD
BQ2B015QXD
TC1Q1 TA1Q1
List Price $
For inches / millimeters conversion, see Application Data section. Built to order. Allow 23 weeks for delivery. Terminals are UL Listed for 60/75C conductors. Also CSA Listed. Connector has steel construction.
Surface mounted indoor. If flush mounting is required, replace suffix S in catalog number with suffix F. Discount Schedule B. Does not include circuit breaker. Order circuit breaker separately. Neutral included in enclosure. Enclosure will not accept circuit breakers with shunt trips or auxiliary switches installed.
17/10
QJ 225A Frame
Selection/Dimensions
Type QJ2
2-Pole Continuous Current Rating @ 40C 060 070 080 090 100 110 125 150 175 200 225 240V AC Catalog Number QJ22B060 QJ22B070 QJ22B080 QJ22B090 QJ22B100 QJ22B110 QJ22B125 QJ22B150 QJ22B175 QJ22B200 QJ22B225 List Price $ 3-Pole 240V AC Catalog Number QJ23B060 QJ23B070 QJ23B080 QJ23B090 QJ23B100 QJ23B110 QJ23B125 QJ23B150 QJ23B175 QJ23B200 QJ23B225 List Price $
Ordering Information
Load side TA1Q300 lugs are mounted and included when circuit breaker is ordered. For line and load lugs (TA1Q300) installed at no additional charge, add suffix L to catalog number. 50 C Calibration - See page 17/110. 400HZ. - See page 17/110.
Shipping Weights
QJ2, QJH2, QJ2H, HQJ2H Number of Poles 2 3 Number per Carton 10 10 Shipping Weight (lbs.) 30 41
Type QJH2
060 070 080 090 100 110 125 150 175 200 225 QJH22B060 QJH22B070 QJH22B080 QJH22B090 QJH22B100 QJH22B110 QJH22B125 QJH22B150 QJH22B175 QJH22B200 QJH22B225 QJH23B060 QJH23B070 QJH23B080 QJH23B090 QJH23B100 QJH23B110 QJH23B125 QJH23B150 QJH23B175 QJH23B200 QJH23B225
Type QJ2H
060 070 080 090 100 110 125 150 175 200 225 QJ22B060H QJ22B070H QJ22B080H QJ22B090H QJ22B100H QJ22B110H QJ22B125H QJ22B150H QJ22B175H QJ22B200H QJ22B225H QJ23B060H QJ23B070H QJ23B080H QJ23B090H QJ23B100H QJ23B110H QJ23B125H QJ23B150H QJ23B175H QJ23B200H QJ23B225H
Type HQJ2H
100 110 125 150 175 200 225 HQJ23B100H HQJ23B110H HQJ23B125H HQJ23B150H HQJ23B175H HQJ23B200H HQJ23B225H
7''
QJ2
Internal Accessories (Factory installed only) (3-pole only) Add suffix to catalog number and adder to list price.
Auxiliary Switches Control Voltage AC 120/240 24 125 DC Shunt Trip Suffix 00S01 00S07 00S11 List Adder $ 1A and 1B Suffix A01 A01 A01 List Adder $ 2A and 2B Suffix A02 A02 A02 List Adder $
Shunt Trip and 1A and 1B Auxiliary Switch Suffix 01S01 01S07 01S11 List Adder $
Built to order. Allow 23 weeks for delivery. Built to order. Allow 68 weeks for delivery. See Note: A page 17/100. Note: QJ breakers are UL Listed for reverse feed applications.
2.5 D 3''
17/11
Selection/Dimensions
Shipping Weights
Number of Poles 1 2 3 Number per Carton 1 1 1 Shipping Weight lbs. (kg) 0.5 (0) 1.0 (0) 1.5 (1)
CQD, CQD6
4.9
Interrupting Ratings
RMS Symmetrical Amperes (KA) Breaker Type CQD (UL) CQD6 (CSA) Number of Poles 1 2 3 1 2 3 Volts AC (50/60 Hz) 120 65 65 240 65 65 65 65 277 14 14 480/277 14 14 600/347 10 10 10 Volts DC 125 14 14 125/250 14 14
CQD, CQD6
For inches / millimeters conversion, see Application Data section. Built to order. Allow 23 weeks for delivery. SWD rated. Note: CQD breakers are UL Listed for reverse feed applications. HID rated. HACR rated.
17/12
List Price $
NGG
5.4
Line and load lugs are included as standard. If no lugs are required, remove the L suffix. HACR rated. Suitable for screws or DIN rail mounting.
NGG
Shipping Weights
Number of Poles 1 2 3 Number per Carton 1 1 1 Shipping Weight lbs. (kg) .75 (0.34) 1.3 (0.59) 2.0 (0.98)
Interrupting Ratings
Breaker Type NGG Number of Poles 01 2, 3 UL 489 AIR RMS Symmetrical Amperes (KA) Volts AC(50/60Hz) 120 240 277 347 65 25 14 0 65 Volts DC 600/347 125 125/250 0 14 14 0 14 IEC 947-2 Volts AC (50/60Hz) 220/240 380/415 lcu lcs lcu 25 12.5 65 33 25 Volts DC 125/250 14
480 25
lcs 12.5
For inches / millimeters conversion, see Application Data section. SWD rated. HID rated at 15-50A 1-pole @ 277 VAC; 2 & 3-pole @ 480 VAC 125/250V DC rating applies to 2-pole NGG only.
17/13
Accessories for CQD 100A Frame, NGG and NGB 125A Frame
Selection
Shunt Trip
Control Voltage V AC 120 240 277 480 600 V DC 012 024 048 125 CQD, CQD6, NGG, NGB Catalog Number CQDST120 CQDST240 CQDST277 CQDST480 CQDST600 CQDST12 CQDST24 CQDST48 CQDST125 List Price $
Auxiliary Switch
Maximum Voltage AC 240 240 DC 125 125 Number of Contacts 1A1B 2A2B CQD, CQD6, NGG, NGB Catalog Number CQDA1 CQDA2 List Price $
Alarm Switch
Maximum Voltage AC 240 DC 125 CQD, CQD6, NGG, NGB Catalog Number CQDBA List Price $
Built to order. Allow 68 weeks for delivery. Adds 1-pole space for accessory.
17/14
The interchangeability of the VL circuit breaker trip units allow for easy conversion from any of 3 types of protection. They are thermal-magnetic, electronic, or electronic with a built-in LCD display. The thermal-magnetic trip unit features an adjustable magnetic trip setting. The electronic trip units are microprocessor based true RMS sensing devices and are available with a variety of adjustable trip settings, configurations, and infor-
mation menus. With precise control over the circuit beaker functions and access to system status, diagnostics, and information, these trip units allow for unsurpassed flexibility in circuit coordination. An example of coordination is the out of the box Ground Fault function on the Model 545 trip units. The pick-up and time delay settings are fixed for each
frame and do not overlap with the settings on the other frames. Therefore, when VL breakers are used together in a system the GF protection is automatically coordinated. The user also has the ability to program a custom coordination scheme with the high level of adjustability available on the Model 576 trip units.
VL Trip Units
Trip Unit Functions Model 525 ThermalMagnetic Continuous Current Setting (Ir) Long Time Delay (tr) Instantaneous Overcurrent Setting (Ii) Short Time Pick-up (Isd) Short Time Delay (tsd) Short Time l t Pick-up
2
Model 576 Electronic with LCD LSI Electronic with LCD LSIG
Fixed
Fixed Fixed
Fixed Fixed
(ON/OFF)
(ON/OFF)
Fixed Fixed
Fixed Fixed
Ground Fault Pick-up (lg) Ground Fault Delay (tg) Alarm & Status LEDs Built-in Display (LCD) Pre-Trip Alarm Last trip information Zone Selective Communications
Adjustable setting. This feature is included. fixed Non-Adjustable setting. Feature is not included. Requires the trip unit to be connected to a PC (via a COMPRO or COMMOD communications module) for access or programming.
Continuous Amps Rating (Ir) This setting is the continuous current that the breaker will carry without tripping. It can be set up to 100% of the trip units nominal rating (In). Long Time Delay (tr) Sometimes referred to as the overload position, this function controls the breakers pause-in-tripping time. It allows low level, temporary inrush currents such as those encountered when starting a motor to pass without tripping. The time delay begins when the current reaches 6 x Ir. Instantaneous Pick-up (Ii) This function sets the breaker to trip instantaneously during high fault conditions. On Model 545 trip units this setSiemens Industry, Inc. Industrial Controls Catalog
ting is fixed on LSI and LSIG trip units and adjustable on LI and LIG trip units. These features are fully adjustable on Model 576 trip units. Short Time Pick-Up (lsd) This function controls the level of fault current the breaker will carry for a short time without tripping, thus allowing downstream devices to clear short circuits ahead of up-stream protection. It may be defeated (turned-off) on Model 576 trip units. Short Time Delay (tsd) This controls the interval of time the breaker will remain closed against a fault (at the Short Time Pick-up current level) without tripping. The time delay may be set at fixed points or at short time intervals based on l2t curves. This function is
used with the Short Time Pick-up to achieve selectivity and better system coordination. Ground Fault Pick-Up (Ig) This setting controls the level of ground fault current that will cause the breaker to trip. Model 545 Electronic Trip Units act on the residual current to sense ground current. The Model 576 Electronic Trip Unit is programmable and allows the user to select either the residual current method or direct detection (via a separate current transformer) to detect ground current. Ground Fault Time Delay (tg) This controls the interval of time the breaker will remain closed after a ground fault is detected (at the Ground Fault Pick-up current level) without tripping. 17/15
General Information
Selection
Thermal-Magnetic trip units, Model 525, combine the inverse time element design for low level overloads, and instantaneous magnetic action for short circuit protection. The standard unit has preset overload protection and an adjustable instantaneous trip setting, with 6 set points. Thermal-Magnetic trip units are available throughout the VL family, from 15 to 1600A.
M4-PAN-TORX
Ii I n = 600A
3850 4400 4950 5500
Type/Tipo CLT3
M4-PAN-TORX
3300 2750
17/16
Ordering Information
Complete Assembled Breaker Prices for a complete factory assembled DG breaker include the frame, trip unit, and standard line and load connectors, all factory installed and shipped as a complete breaker. Assembled breakers are only available with standard connectors. For any other configuration, order the frame, trip unit, and terminals as separate items. For DC applications, use thermal magnetic trip unit only. For reverse feed applications, select non-interchangeable trip breakers only. For non-interchangeable trip breakers, change the third digit of the catalog number to X for standard breakers. For special applications, refer to page 17/62.A Mounting hardware is included with each frame or complete breaker. For 100% rated breakers with a non-interchangeable trip unit, change the 3rd character of the catalog number to Y.
Interrupting Ratings
RMS Symmetrical Amperes (KA) UL 489 IEC 60947-2 Volts AC (50/60 Hz) Volts DC Volts AC (50/60 Hz) 220/240 380/415 240 480 600 250 500 ICU ICS ICU ICS 65 35 18 30 18 65 65 40 40 100 65 20 30 18 100 75 70 70 200 100 25 30 18 200 150 100 75
Standard connector supplied with complete breakers. Kit consists of 3 terminal connectors. 2 Lugs for 2-pole breakers. 3 Lugs for 3-pole breakers.
Note: Each breaker has 6 trip settings in this range. A - Consult with Siemens for availability.
17/17
Ii
1120 960 800
I n =150A
40? C
TM ~ TRIP UNIT/DISPARADOR 525
Cat. No. - CDT3B150
FRAME ONLY HDG2F150 HDG2B050L HDG2B060L HDG2B070L HDG2B080L HDG2B090L HDG2B100L HDG2B110L HDG2B125L HDG2B150L
FRAME ONLY HDG3F150 HDG3B050L HDG3B060L HDG3B070L HDG3B080L HDG3B090L HDG3B100L HDG3B110L HDG3B125L HDG3B150L
17/18
Continuous Ampere Rating 60 100 150 60 100 150 60 100 150 60 100 150
FRAME ONLY HDG3F150 ELECTRONIC LI TRIP HDG3N060L HDG3N100L HDG3N150L ELECTRONIC LSI TRIP HDG3P060L HDG3P100L HDG3P150L ELECTRONIC LSIG TRIP HDG3U060L HDG3U100L HDG3U150L ELECTRONIC LIG TRIP HDG3X060L HDG3X100L HDG3X150L
COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER NDG3N060L NDG3N100L NDG3N150L NDG3P060L NDG3P100L NDG3P150L NDG3U060L NDG3U100L NDG3U150L NDG3X060L NDG3X100L NDG3X150L LDG3N060L LDG3N100L LDG3N150L LDG3P060L LDG3P100L LDG3P150L LDG3U060L LDG3U100L LDG3U150L LDG3X060L LDG3X100L LDG3X150L
FRAME ONLY HDG3F150 LCD ELECTRONIC LSI TRIP HDG3D060L HDG3D100L HDG3D150L LCD ELECTRONIC LSIG TRIP HDG3E060L HDG3E100L HDG3E150L
COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER NDG3D060L NDG3D100L NDG3D150L NDG3E060L NDG3E100L NDG3E150L LDG3D060L LDG3D100L LDG3D150L LDG3E060L LDG3E100L LDG3E150L
17/19
Complete Assembled Breaker Prices for a complete factory assembled FG breaker include the frame, trip unit, and standard line and load connectors, all factory installed and shipped as a complete breaker. Assembled breakers are available only with standard connectors. For any other configuration, order the frame, trip unit, and terminals as separate items. For DC applications, use thermal magnetic trip unit only. For reverse feed applications, select non-interchangeable trip breakers only. For non-interchangeable trip breakers, change the third digit of the catalog number to X for standard breakers. For special applications, refer to page 17/62.A Mounting hardware is included with each frame or complete breaker. For 100% rated breakers with a non-interchangeable trip unit, change the 3rd character of the catalog number to Y. Available with ETU only.
Interrupting Ratings
RMS Symmetrical Amperes (KA) UL 489 IEC 60947-2 Volts AC (50/60 Hz) Volts DC Volts AC (50/60 Hz) 220/240 380/415 240 480 600 250 500 ICU ICS ICU ICS 65 35 18 30 18 65 65 40 40 100 65 20 30 25 100 75 70 70 200 100 25 30 30 200 150 100 75
2.2 (1.0)
2.6 (1.2)
Standard connector supplied with complete breakers. Kit consists of 3 terminal connectors. 2 Lugs for 2-pole breakers. 3 Lugs for 3-pole breakers.
17/20
Ii
1750 1500 1250
I n =250A
40? C
TM ~ TRIP UNIT/DISPARADOR 525
Cat. No. - CFT3B250
Continuous Ampere Rating 100 110 125 150 175 200 225 250
FRAME ONLY HFG2F250 HFG2B100L HFG2B110L HFG2B125L HFG2B150L HFG2B175L HFG2B200L HFG2B225L HFG2B250L
Continuous Ampere Rating 100 110 125 150 175 200 225 250
FRAME ONLY HFG3F250 HFG3B100L HFG3B110L HFG3B125L HFG3B150L HFG3B175L HFG3B200L HFG3B225L HFG3B250L
17/21
Continuous Ampere Rating 100 150 250 100 150 250 100 150 250 100 150 250
FRAME ONLY HFG3F250 ELECTRONIC LI TRIP HFG3N100L HFG3N150L HFG3N250L ELECTRONIC LSI TRIP HFG3P100L HFG3P150L HFG3P250L ELECTRONIC LSIG TRIP HFG3U100L HFG3U150L HFG3U250L ELECTRONIC LIG TRIP HFG3X100L HFG3X150L HFG3X250L
COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER NFG3N100L NFG3N150L NFG3N250L NFG3P100L NFG3P150L NFG3P250L NFG3U100L NFG3U150L NFG3U250L NFG3X100L NFG3X150L NFG3X250L LFG3N100L LFG3N150L LFG3N250L LFG3P100L LFG3P150L LFG3P250L LFG3U100L LFG3U150L LFG3U250L LFG3X100L LFG3X150L LFG3X250L
FRAME ONLY HFG3F250 LCD ELECTRONIC LSI TRIP HFG3D100L HFG3D150L HFG3D250L LCD ELECTRONIC LSIG TRIP HFG3E100L HFG3E150L HFG3E250L
COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER NFG3D100L NFG3D150L NFG3D250L NFG3E100L NFG3E150L NFG3E250L LFG3D100L LFG3D150L LFG3D250L LFG3E100L LFG3E150L LFG3E250L
17/22
ASKL2
Left, Right
ASKL3
Shunt Trips
Description 24 VDC 48-60 VDC 110-127 VDC 220-250 VDC 48-60 VAC 110-127 VAC 208-277 VAC 380-600 VAC Mounting Pocket Catalog Number STRLB24DC STRLC60DC STRLD125DC STRLE250DC STRLM60 STRLN120 STRLS277 STRLV600 List Price $
Undervoltage Release
Description 12 VDC 24 VDC 48 VDC 60 VDC 110-127 VDC 220-250 VDC 24 VAC 110-127 VAC 220-240 VAC 208 VAC 277 VAC 380-415 VAC 440-480 VAC Mounting Pocket Catalog Number UVRLA12DC UVRLB24DC UVRLC48DC UVRLG60DC UVRLD125DC UVRLE250 UVRLL24 UVRLN120 UVRLR240 UVRLP208 UVRLS277 UVRLT415 UVRLU480 List Price $
A refers to a normally open contact (open when the breaker contacts are open). B refers to a normally closed contact (closed when the breaker contacts are open). Refer to the Accessory Locations chart for guidelines and limitations about which pockets may be used for accessory combinations. These kits include two bases, one for mounting switches in the left pocket and another for mounting in the right. Includes 1A and 1B contact for alarm purposes, only one of which may be installed at any time.
17/23
Complete Assembled Breaker Prices for a complete factory assembled JG breaker include the frame, trip unit, and standard line and load connectors, all factory installed and shipped as a complete breaker. Assembled breakers are available only with standard connectors. For any other configuration, order the frame, trip unit, and terminals as separate items. For DC applications, use thermal magnetic trip unit only. For reverse feed applications, select non-interchangeable trip breakers only. For non-interchangeable trip breakers, change the third digit of the catalog number to X for standard breakers. For 100% rated breakers with a non-interchangeable trip unit, change the 3rd character of the catalog number to Y. For special applications, refer to page 17/62.A Mounting hardware is included with each frame or complete breaker.
Interrupting Ratings
RMS Symmetrical Amperes (KA) UL 489 AIR (File E10848) IEC 60947-2 Volts AC (50/60 Hz) Volts DC Volts AC (50/60 Hz) 220/240 380/415 240 480 600 250 500 ICU ICS ICU ICS 65 35 25 30 25 65 65 45 45 100 65 25 30 35 100 75 70 70 200 100 25 30 35 200 150 100 75
Complete Breaker
4.0 (1.8)
Standard construction supplied for each breaker. Kit consists of 3 terminal connectors. 3 Lugs for 3-pole breakers. For 100% rate applications, 90C.
17/24
M4-PAN-TORX
Ii I n = 400A
3200 3600 4000
M4-PAN-TORX
COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER HJG2B250L LJG2B250L HJG2B300L LJG2B300L HJG2B350L LJG2B350L HJG2B400L LJG2B400L
COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER HJG3B250L LJG3B250L HJG3B300L LJG3B300L HJG3B350L LJG3B350L HJG3B400L LJG3B400L
JJ 400A Frame 240V max., 2-pole with Thermal-Magnetic Non-Interchangeable Trip Unit
N-Interrupting Class Continuous Ampere Rating 250 300 350 400 Catalog Number List Price $
JJ 400A Frame 240V max., 3-pole with Thermal-Magnetic Non-Interchangeable Trip Unit
N-Interrupting Class Continuous Ampere Rating 250 300 350 400 Catalog Number List Price $
17/25
Continuous Ampere Rating 250 400 250 400 250 400 250 400
FRAME ONLY HJG3F400 ELECTRONIC LI TRIP HJG3N250L HJG3N400L ELECTRONIC LSI TRIP HJG3P250L HJG3P400L ELECTRONIC LSIG TRIP HJG3U250L HJG3U400L ELECTRONIC LIG TRIP HJG3X250L HJG3X400L
COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER NJG3N250L NJG3N400L NJG3P250L NJG3P400L NJG3U250L NJG3U400L NJG3X250L NJG3X400L LJG3N250L LJG3N400L LJG3P250L LJG3P400L LJG3U250L LJG3U400L LJG3X250L LJG3X400L
FRAME ONLY HJG3F400 LCD ELECTRONIC LSI TRIP HJG3D250L HJG3D400L LCD ELECTRONIC LSIG TRIP HJG3E250L HJG3E400L
COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER NJG3D250L NJG3D400L NJG3E250L NJG3E400L LJG3D250L LJG3D400L LJG3E250L LJG3E400L
17/26
Ordering Information
Complete Assembled Breaker Prices for a complete factory assembled LG breaker include the frame, trip unit, and standard line and load lugs, all factory installed and shipped as a complete breaker. Assembled breakers are available only with standard connectors. For any other configuration, order the frame, trip unit, and terminals as separate items. For DC applications, use thermal magnetic trip unit only. For reverse feed applications, select non-interchangeable trip breakers only. Change the third digit of the catalog number to X for non-interchangeable trip unit. For special applications, refer to page 17/62.A Mounting hardware is included with each frame or complete breaker. For 100% rated breakers with a non-interchangeable trip unit, change the 3rd character of the catalog number to Y. Available on 400/500 Amp only.
Complete Breaker
2, 3 17.4 (7.9)
3.5 (1.6)
Standard construction supplied for each breaker. Kit consists of 3 terminal connectors. Kit consists of 6 lugs for Line or Load end.
17/27
M4-PAN-TORX
Ii I n = 600A
3850 4400 4950 5500
Type/Tipo CLT3
M4-PAN-TORX
3300 2750
17/28
Continuous Ampere Rating 400 600 400 600 400 600 400 600
FRAME ONLY HLG3F600 ELECTRONIC LI TRIP HLG3N400L HLG3N600L ELECTRONIC LSI TRIP HLG3P400L HLG3P600L ELECTRONIC LSIG TRIP HLG3U400L HLG3U600L ELECTRONIC LIG TRIP HLG3X400L HLG3X600L
COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER NLG3N400L NLG3N600L NLG3P400L NLG3P600L NLG3U400L NLG3U600L NLG3X400L NLG3X600L LLG3N400L LLG3N600L LLG3P400L LLG3P600L LLG3U400L LLG3U600L LLG3X400L LLG3X600L
FRAME ONLY HLG3F600 LCD ELECTRONIC LSI TRIP HLG3D400L HLG3D600L LCD ELECTRONIC LSIG TRIP HLG3E400L HLG3E600L
COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER NLG3D400L NLG3D600L NLG3E400L NLG3E600L LLG3D400L LLG3D600L LLG3E400L LLG3E600L
17/29
ASKL2
Left, Right
ASKL3
Shunt Trips
Description 24 VDC 48-60 VDC 110-127 VDC 220-250 VDC 48-60 VAC 110-127 VAC 208-277 VAC 380-600 VAC Mounting Pocket Catalog Number STRLB24DC STRLC60DC STRLD125DC STRLE250DC STRLM60 STRLN120 STRLS277 STRLV600 List Price $
Undervoltage Release
Description 12 VDC 24 VDC 48 VDC 60 VDC 110-127 VDC 220-250 VDC 24 VAC 110-127 VAC 220-240 VAC 208 VAC 277 VAC 380-415 VAC 440-480 VAC Mounting Pocket Catalog Number UVRLA12DC UVRLB24DC UVRLC48DC UVRLG60DC UVRLD125DC UVRLE250DC UVRLL24 UVRLN120 UVRLR240 UVRLP208 UVRLS277 UVRLT415 UVRLU480 List Price $
A refers to a normally open contact (open when the breaker contacts are open). B refers to a normally closed contact (closed when the breaker contacts are open). Refer to the Accessory Locations chart for guidelines and limitations about which pockets may be used for accessory combinations. Includes 1A and 1B contact for alarm purposes, only one of which may be installed at any time.
17/30
Ordering Information
Complete Assembled Breaker Prices for a complete factory assembled MG breaker include the frame, trip unit, and standard line and load lugs, all factory installed and shipped as a complete breaker. Assembled breakers are available only with standard connectors. For any other configuration, order the frame, trip unit, and terminals as separate items. For DC applications, use thermal magnetic trip unit only. For reverse feed applications, select non-interchangeable trip breakers only. For non-interchangeable trip breakers, change the third digit of the catalog number to X for standard breakers. 100% Rated: For 100% rated breakers (or frames) with an interchangeable trip unit, change the 3rd character of the catalog name to H. For 100% rated breakers with a non-interchangeable trip unit, change the 3rd character of the catalog number to Y. For 50C and special applications, refer to page 17/62.A Mounting hardware is included with each frame or complete breaker.
Interrupting Ratings
RMS Symmetrical Amperes (KA) UL 489 IEC 60947-2 Volts AC (50/60 Hz) Volts DC Volts AC (50/60 Hz) 220/240 380/415 240 480 600 250 500 ICU ICS ICU ICS 65 35 25 22 35 65 65 50 50 100 65 35 25 50 100 75 70 70 200 100 50 42 65 200 150 100 75
Total of 9 connectors (3 per phase Line or Load). Kit consists of 3 terminal connectors. Standard connector supplied with complete breakers. Includes extended terminal cover. Consists of one terminal. For 100% rated applications.
17/31
Ii
5200 5850
3250
6500
17/32
Ir
300 300 800
Amps
315 350
I
400 500 600
sd
1.5 1.5 7
1.5
t sd
2.5 3 4
Sec.
.1 0
2
.2
.3
.4 OFF .5 .1
I t
V1.04
X3 680HG
700
630
xI r
I t
.4 .3
ON
.2
Active
Continuous Ampere Rating 600 800 600 800 600 800 600 800
FRAME ONLY HMG3F800 ELECTRONIC LI TRIP HMG3N600L HMG3N800L ELECTRONIC LSI TRIP HMG3P600L HMG3P800L ELECTRONIC LSIG TRIP HMG3U600L HMG3U800L ELECTRONIC LIG TRIP HMG3X600L HMG3X800L
COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER NMG3N600L NMG3N800L NMG3P600L NMG3P800L NMG3U600L NMG3U800L NMG3X600L NMG3X800L LMG3N600L LMG3N800L LMG3P600L LMG3P800L LMG3U600L LMG3U800L LMG3X600L LMG3X800L
X3 680JM
FRAME ONLY HMG3F800 LCD ELECTRONIC LSI TRIP HMG3D600L HMG3D800L LCD ELECTRONIC LSIG TRIP HMG3E600L HMG3E800L
COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER NMG3D600L NMG3D800L NMG3E600L NMG3E800L LMG3D600L LMG3D800L LMG3E600L LMG3E800L
17/33
Complete Assembled Breaker with Lugs Prices for a complete factory assembled NG breaker include the frame, trip unit, and standard line and load lugs, all factory installed and shipped as a complete breaker. Assembled breakers are available only with standard connectors. For any other configuration, order the frame, trip unit, and terminals as separate items. For DC applications, use thermal magnetic trip unit only. For reverse feed applications, select non-interchangeable trip breakers only. For non-interchangeable trip breakers, change the third digit of the catalog number to X for standard breakers. For 100% rated breakers with a non-interchangeable trip unit, change the 3rd character of the catalog number to Y. For special applications, refer to page 17/62.A Mounting hardware is included with each frame or complete breaker. A Toggle Handle Extension is included with each frame or complete breaker.
Interrupting Ratings
RMS Symmetrical Amperes (KA) UL 489 IEC 60947-2 Volts AC (50/60 Hz) Volts DC Volts AC (50/60 Hz) 220/240 380/415 240 480 600 250 500 ICU ICS ICU ICS 65 35 25 22 35 65 35 50 25 100 65 35 25 50 100 50 70 35 200 100 65 42 65 200 100 100 50
Total of 12 connectors (4 per phase Line or Load). 90 C for 100% rated breakers. Standard connector provided with complete breakers. Kit consists of 3 terminal connectors.
17/34
Ii
10000 11000 12000
Ii
10000 11000 12000 8000 7000 9000
AMPS
Ii
10000 11000 12000
Amps
17/35
Ir
400 400 1200
Amps
500 600
tr
630 700 2.5 30
Sec.
Ii
10 14 17
Amps x10
240 360
V2.02
X3
1000
900
800
25
20
1200
960
Trip Unit/Disparador
545
Continuous Ampere Rating 800 1000 1200 800 1000 1200 800 1000 1200 800 1000 1200
FRAME ONLY HNG3F120 ELECTRONIC LI TRIP HNG3N800L HNG3N100L HNG3N120L ELECTRONIC LSI TRIP HNG3P800L HNG3P100L HNG3P120L ELECTRONIC LSIG TRIP HNG3U800L HNG3U100L HNG3U120L ELECTRONIC LIG TRIP HNG3X800L HNG3X100L HNG3X120L
COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER NNG3N800L NNG3N100L NNG3N120L NNG3P800L NNG3P100L NNG3P120L NNG3U800L NNG3U100L NNG3U120L NNG3X800L NNG3X100L NNG3X120L LNG3N800L LNG3N100L LNG3N120L LNG3P800L LNG3P100L LNG3P120L LNG3U800L LNG3U100L LNG3U120L LNG3X800L LNG3X100L LNG3X120L
FRAME ONLY HNG3F120 LCD ELECTRONIC LSI TRIP HNG3D800L HNG3D100L HNG3D120L LCD ELECTRONIC LSIG 4-W TRIP HNG3E800L HNG3E100L HNG3E120L
COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER NNG3D800L NNG3D100L NNG3D120L NNG3E800L NNG3E100L NNG3E120L LNG3D800L LNG3D100L LNG3D120L LNG3E800L LNG3E100L LNG3E120L
17/36
Interrupting Ratings
RMS Symmetrical Amperes (KA) UL 489 IEC 60947-2 Volts AC (50/60 Hz) Volts DC Volts AC (50/60 Hz) 220/240 380/415 240 480 600 250 500 ICU ICS ICU ICS 65 35 25 22 35 65 35 50 25 100 65 35 25 50 100 50 70 35 200 100 65 42 65 200 100 100 50
Requires Lug Mounting Assembly LMAP1600. Requires Breaker Mounting Base MBPG1600 Kit or MBPG1601. Consists of 3 connectors. Consists of 1 connector. For 100% rated applications, 90C.
Mounting Arrangement
Description Lug Mounting Assembly Breaker Mounting Base (Front Connect) Breaker Mounting Base (Rear Connect) Catalog Number LMAP1600 MBPG1600 MBPG1601 List Price $
17/37
Continuous Ampere Rating 1200 1600 1200 1600 1200 1600 1200 1600
FRAME ONLY HPG3F160 ELECTRONIC LI TRIP HPG3N120 HPG3N160 ELECTRONIC LSI TRIP HPG3P120 HPG3P160 ELECTRONIC LSIG TRIP HPG3U120 HPG3U160 ELECTRONIC LIG TRIP HPG3X120 HPG3X160
COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER NPG3N120 NPG3N160 NPG3P120 NPG3P160 NPG3U120 NPG3U160 NPG3X120 NPG3X160 LPG3N120 LPG3N160 LPG3P120 LPG3P160 LPG3U120 LPG3U160 LPG3X120 LPG3X160
FRAME ONLY HPG3F160 LCD ELECTRONIC LSI TRIP HPG3D120 HPG3D160 LCD ELECTRONIC LSIG TRIP HPG3E120 HPG3E160
COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER NPG3D120 NPG3D160 NPG3E120 NPG3E160 LPG3D120 LPG3D160 LPG3E120 LPG3E160
17/38
ASKP4
x4
x4
Shunt Trips
Description 24 VDC 48-60 VDC 110-127 VDC 220-250 VDC 48-60 VAC 110-127 VAC 208-277 VAC 380-600 VAC Right Pocket Only Mounting Pocket Catalog Number STRPB24DC STRPC60DC STRPD125DC STRPE250DC STRPM60 STRPN120 STRPS277 STRPV600 List Price $
Undervoltage Release
Description 12 VDC 24 VDC 48 VDC 60 VDC 110-127 VDC 220-250 VDC 110-127 VAC 220-240 VAC 208 VAC 277 VAC 380-415 VAC 440-480 VAC Right Pocket Only Mounting Pocket Catalog Number UVRPA12DC UVRPB24DC UVRPC48DC UVRPG60DC UVRPD125DC UVRPE250DC UVRPN120 UVRPR240 UVRPP208 UVRPS277 UVRPT415 UVRPU480 List Price $
A refers to a normally open contact (open when the breaker contacts are open). B refers to a normally closed contact (closed when the breaker contacts are open). Refer to the Accessory Locations chart for guidelines and limitations about which pockets may be used for accessory combinations.
17/39
General Typically a molded case switch is used when a compact load-break switch is needed for disconnect purposes. The VL line of molded case switches from Siemens is made of the same materials and components as the VL circuit breakers but do not provide overcurrent protection. Each molded case
switch has a fixed instantaneous selfprotecting trip element which may open the switch under high fault conditions. Application Note Overcurrent protection must be provided by an appropriate overcurrent protective device located upstream from
the molded case switch. Also, the short-circuit current rating of the switch is limited to the interrupting rating of the upstream protective device or the ratings in the table below, whichever is less.
Ordering Information
Each type VL molded case switch accepts the same terminals and accessories as the equivalent VL circuit breakers. All type VL molded case switches are suitable for reverse feed applications. Mounting hardware and standard line and load terminals are included on ratings through 250A. For 400 1600A ratings, order the lugs separately. All ratings are UL listed and CSA certified.
Maximum Ampere Rating / Frame 250A /FG 400A / JG 600A / LG 800A / MG 1200A / NG 1600A / PG
List Price $
Short-Circuit Current Rating* 240V 200k 200k 200k 200k 200k 200k 480V 100k 100k 100k 100k 100k 100k 600V 25k 42k 42k 50k 65k 65k
Self Protective Instantaneous Override 3,500A 4,400A 5,500A 6,500A 12,000A 12,000A
* The Short-Circuit Current Rating is the maximum available current of the circuit where the switch is used, when protected by an appropriate overcurrent protective device. Above 250A, terminals are not included and must be ordered separately. For terminal information and the variety of lugs available for VL breakers.
17/40
General Protection of Motor Circuits Molded case circuit breakers are used in motor circuits as a disconnecting means and for short-circuit protection. They should be used in conjunction with motor-running, over-current protection devices, and should permit the motor to start without nuisance tripping from motor-inrush current. The circuit breaker should have a continuous current rating of not less than 115% of the motor fullload current. The recommended motor circuit protectors listed have continuous-current ratings of at least 115% of motor full-load currents. The trip setting positions are approximately 11 times motor full-load current. The suggested trip settings may need to be adjusted upward to no higher than 1300% of full-load current for non-design E type motors, and no greater than 1700% of full-load current for design E motors, to allow for motor startup due to in-rush current. Breaker Mounted Immediately Ahead of Motor Starter Siemens motor circuit protectors are recommended for use in combination motor starters to provide selective short-circuit protection for the motor branch circuit. The adjustable instantaneous trip feature of the Siemens motor circuit protector provides for a trip setting slightly above the peak motor in-rush current. With this setting, no delay is introduced in opening the circuit when a fault occurs. This circuit breaker has no time-delay trip element. Therefore it must be used in conjunction with, and immediately ahead of, the motor-running overcurrent protection device. Important: The information below does not apply to all motor applications: it is recommended that the user refer to the National Electrical Code (NEC) for specific needs. Table 1 (When Breaker is Mounted Immediately Ahead of Motor Starter)
3-Phase Induction Type Motors (Siemens motor circuit protectors for branch circuit use with alternating-current combination, full voltage motor starters) Motor Full Load Amperes 35-50 42-60 48-70 55-80 62-90 69-100 58-83 69-100 81-117 92-133 104-150 115-150 96-139 115-150 135-150 135-150 135-150 135-150 46-67 55-80 65-93 74-107 83-120 92-133 77-111 92-133 108-156 123-178 138-200 154-222 135-194 162-210 188-220 215-241 242-250 242-250 Trip Setting (A) 450 540 630 720 810 900 750 900 1050 1200 1350 1500 1250 1500 1750 2000 2250 2500 600 720 840 960 1080 1200 1000 1200 1400 1600 1800 2000 1750 2100 2450 2800 3150 3500 Catalog Number Motor Full Load Amperes 96-139 115-167 135-194 154-222 173-250 192-278 154-222 185-267 215-311 246-356 277-400 308-400 154-222 185-267 215-311 246-356 277-400 308-444 212-306 254-367 296-428 338-489 381-550 423-600 250-361 292-422 335-483 385-556 442-638 500-722 385-556 462-667 538-778 615-889 692-1000 769-1111 Trip Setting (A) 1250 1500 1750 2000 2250 2500 2000 2400 2800 3200 3600 4000 2000 2400 2800 3200 3600 4000 2750 3300 3850 4400 4950 5500 3250 3800 4350 5000 5740 6500 5000 6000 7000 8000 9000 10,000 Catalog Number
List Price $
List Price $
HDM3L150L
HJM3L400
HDM3M150L
HJM3M400
HDM3H150L
HLM3L600
HFM3L250L
HLM3M600
HFM3M250L
HMM3M800
HFM3H250L
HNM3M120
Motor circuit protectors rated 150A and 250A are supplied with line and load lugs installed. If lugs are required on 400A to 1200A motor circuit breakers, order required lugs separately.
These settings are provided for starting currents greater than 11X but not to exceed 17X. Full Load Amps ( FLA ) not to exceed ampere rating of MCP.
17/41
the table. This family of circuit breakers is rated from 50 to 1600 Amperes. Types HDGD through HPGD circuit breakers are provided with an adjustable magnetic over-current function located on the face of the circuit breaker. Contact Siemens for specific magnetic over-current values. To properly use these UL Listed circuit breakers at 600Vdc and the indicated
interruption level, it is necessary to connect the terminals of the 3 pole circuit breaker in a series configuration as shown in the diagram below. Types HDGD through HPGD use the same internal and external accessories as the standard DG through PG frames and associated types. Consult the individual frame section for accessory information.
Frame
Type
Catalog Number (3-pole) HDC3B050 HDC3B060 HDC3B070 HDC3B080 HDC3B090 HDC3B100 HDC3B110 HDC3B125 HDC3B150 HFC3B100 HFC3B150 HFC3B250 HJC3B250 HJC3B300 HJC3B350 HJC3B400 HLC3B400 HLC3B600 HMC3B600 HMC3B700 HMC3B800 HNC3B800 HNC3B900 HNC3B100 HNC3B120 HPC3B120 HPC3B140 HPC3B160
List Price $
Short-Circuit Current Rating 600VDC 42K 42K 42K 42K 42K 42K 42K 42K 42K 42K 42K 42K 65K 65K 65K 65K 65K 65K 65K 65K 65K 65K 65K 65K 65K 65K 65K 65K
DG
HDGD
LOAD
FG
HFGD
JG
LG
MG
HMGD
NG
PG
HPGD
1400 1600
Terminal connectors must be ordered separately; see pg. 17/52. Standard VL breakers DG - PG feature DC ratings up to 500V for ungrounded UPS applications. Consult the individual frame section for more information.
17/42
Operating Mechanisms
Selection
17/43
Operating Mechanisms
Selection
Description Through-Door Rotary Handle Operator Kit Fixed depth and the handle is mounted directly on the circuit breaker. Lockable knob (for up to 3 padlocks). NEMA 1, 12 Red Handle Version with red knob, yellow indicator plate NEMA 1, 12 Door-Mounted Rotary Handle Operator Kit Variable depth, door mounted handle. Includes knob with masking frame, indicator plate, detachable door coupling, 12" shaft, and breaker mounted rotary operator. Lockable knob (for up to 3 padlocks). NEMA 1, 12 Auxiliary Switch Kits For Direct or Extended Rotary Handle Operators (RHF and RHV). Form C, Early Break type2 Aux. Switch Kit Includes 1 switch with 5' wire For Door-Mounted Operator For Through-Door Operator Includes 2 switches with 5' wire For Door-Mounted Operator For Through-Door Operator Door-Mounted Rotary Operator Mechanism Breaker mechanism only Door-Mounted Rotary Handle Only Standard version NEMA 1, 12 NEMA 3R NEMA 4X Red Handle version Extension Shaft Only, for Door Mounted Operator 2 inches (50.8mm) 3 inches (76.2mm) 12 inches (304.8 mm) 16 inches (406.4 mm) 24 inches (609.6mm) w/ support bracket
RHFF
RHFL
RHFFEM
RHFLEM
RHVF12
RHVL12
RHVFBM
RHVLBM
During manual operation, Early Break auxiliary switch contacts open before the breaker opens. CSO - Consult Sales Office for pricing.
17/44
Operating Mechanisms
Selection
Description Through-Door Rotary Handle Operator Kit Fixed depth, breaker mounted. For direct fitting to the circuit breaker. Lockable with up to 3 padlocks. NEMA 1, 12 Red Handle version with red knob, yellow indicator plate NEMA 1, 12 Door-Mounted Rotary Handle Operator Kit Variable depth, door mounted handle. Includes knob with masking frame, indicator plate, detachable door coupling, 12" shaft, and breaker mounted rotary operator. Lockable knob (for up to 3 padlocks). NEMA 1, 12 Auxiliary Switch Kits For Direct or Extended Rotary Handle Operators (RHF and RHV). Early Break type2 Aux. Switch Kit Includes 1 switch with 5' wire For Door-Mounted Operator For Through-Door Operator Includes 2 switches with 5' wire For Door-Mounted Operator For Through-Door Operator Door-Mounted Rotary Operator Mechanism Breaker mechanism only Door-Mounted Rotary Handle Only Standard version Red Handle version Extension Shaft Only, for Door Mounted Operator 2 inches (50.8mm) 3 inches (76.2mm) 12 inches (304.8 mm) 16 inches (406.4 mm) 24 inches (609.6mm) w/ support bracket NEMA 1, 12 NEMA 3R NEMA 4X
RHVM12
RHSMA1 RHSMA2
RHSPA1 RHSPA2
RHVMBM
RHVPBM
17/45
Operating Mechanisms
Selection
Description Max-Flex, Variable Depth Flange Mounted Operator Kit Complete kit, includes plastic handle, breaker operator, and cable. NEMA 1, 3R, 12 For DG and FG operators, the cable is 36", all others are 48" Handle Only, for Max-Flex Variable Depth NEMA 1, 3R, 12 Plastic NEMA 1, 3R, 12 Steel - epoxy coated NEMA 4, 4X Steel - chrome plated Solid color (all gray) Plastic NEMA 1, 3R, 12 Solid color (black handle) Steel epoxy coated NEMA 1, 3R, 12 Breaker Operator Mechanism Only, for Max-Flex Cable Only, for Max-Flex Variable Depth 36" 48" 60" 72" 84" 96" 120" 144" Handle Auxiliary Switch Form C (1NO - 1NC), early break 1 Aux. switch 2 Aux. switch
MFKF3R
MFKL3R
MFSFA1 MFSFA2
MFSLA1 MFSLA2
Max-Flex handles are available with solid gray or black handles instead of the customary Red for On flange handle. The black handle is preferred for IEC markets, where red handles have a specific meaning. During manual operation, Early Break aux. contacts open before the breaker opens. CSO - Consult Sales Office for pricing.
17/46
Operating Mechanisms
Selection
Description Max-Flex, Variable Depth Flange Mounted Operator Kit Complete kit, includes plastic handle, breaker operator, and cable. NEMA 1, 3R, 12 For DG and FG operators, the cable is 36", all others are 48" Handle Only, for Max-Flex Variable Depth NEMA 1, 3R, 12 Plastic NEMA 1, 3R, 12 Steel - epoxy coated NEMA 4, 4X Steel - chrome plated Solid color (all gray) Plastic NEMA 1, 3R, 12 Solid color (black handle) Steel epoxy coated NEMA 1, 3R, 12 Breaker Operator Mechanism Only, for Max-Flex Cable Only, for Max-Flex Variable Depth 36" 48" 60" 72" 84" 96" 120" 144" Handle Auxiliary Switch Form C (1NO - 1NC), early break 1 Aux. switch 2 Aux. switch
List Price $
MFKM3R
MFKP3RS
MFKP3RS
MFSPA1 MFSPA2
MFSPA1 MFSPA2
MFSPA1 MFSPA2
17/47
Operating Mechanisms
Selection
Description Stored Energy and Motor Operators Lockable with up to 3 padlocks. AC Voltage 42-48 60 110127 220250 DC Voltage 24 42-48 60 110127 220250
PCBDRC3 PCBDFC3
PCBFRC3 PCBFFC3
DCADRC3 DCADFC3
DCAFRC3 DCAFFC3
DCHP DCIP
DCHP DCIP
PCTF83
PCTF83
PCAF390
PCAF390
PCXD3
PCXF3
DCXD3
DCXF3
PCXFT
PCXFT
Up to 2 position indicator switches may be mounted per plug-in or draw-out base. Up to 2 plugs per breaker (16 terminal points) may be mounted on DG, and FG breakers. Up to 3 plugs per breaker (24 terminal points) may be mounted on JG, LG, MG, NG, and PG breakers. CSO - Consult Sales Office for pricing.
17/48
Operating Mechanisms
Selection
List Price $
List Price $
PCBJRC3 PCBJFC3
PCBLRC3 PCBLFC3
PCBMRC3
PCBNRC3
DCAJRC3 DCAJFC3
DCALRC3 DCALFC3
DCAMRC3 DCAMFC3
DCANRC3 DCANFC3
DCHP DCIP
DCHP DCIP
DCHP DCIP
DCHP DCIP
DCHP DCIP
PCTL83
PCTL83
PCTM83
PCTN83
PCXJ3
PCXL3
PCXM3
PCXN3
DCXJ3
DCXL3
DCXM3
DCXN3
PCXLT
PCXLT
PCXMT
PCXPT
PCXPT
17/49
Connections
Selection
Description Front Bus Bar Connections Includes nut keeper plates and shield. Standard (straight) 3-Pole Set Bus Bar Connection Strap Kit Includes 6 - Bus Bars, 6 Nut Keepers & Shields 100% rated applications Rear-Connecting Studs Short length round term. (1piece) Long length round term. (1piece) 3-Pole round term. kit, 2 short + 1 long Short length flat term. (1piece) Long length flat term. (1piece) 3-Pole flat term. kit, 2 short + 1 long Flat bus bar type (1 piece) 3-Pole set of flat bus bar
FBCD3
FBCF3
Round Terminal
TSSF3 TSLF3
TSSF3 TSLF3
Flat Terminal
Interphase Barriers Set of 2 barriers Also fits plug-in and draw-out bases.
IPBF
IPBF
Terminal Shields
Interphase Barriers
Not UL listed. Only fits standard terminal covers. CSO - Consult Sales Office for pricing.
17/50
Connections
Selection
FBCJ3A
FBCL3A
FBCM3A
RTLLSF SRTLF3
RTLMSF SRTMF3
RTLNSF SRTNF3
TSSL3 TSLL3
TSSL3 TSLL3
TSSM3 TSLM3
TSSP3 TSLP3
TSSP3 TSLP3
IPBM
IPBM
IPBM
IPBP
IPBP
LMAP1600
MBPG1600 MBPG1601
17/51
Connections
Selection
Discription Nut Keeper Plates For ring/tongue terminal or bus bar connections. (For metric threads on other than the JG or LG frame, change TNK to TMK) 1 Nut Keeper Plate Kit of 3
List Price $
List Price $
TNKD TNKD3
TNKF TNKF3
Mechanical Lugs Steel Wrap Around Body (Cu Wire Only) Cable Size; (cables per phase) Single Lug Kit of 3
#8-1/0; 1-hole TW1DG20 3TW1DG20 #6-3/0; 1-hole TA1DG30 3TA1DG30 #6-3/0; 1-hole TC1DG30 3TC1DG30
#4-350 kcmil; 1-hole TW1FG350 3TW1FG350 #4-350 kcmil; 1-hole TAW1FG350 3TAW1FG350
Aluminum Body (Al or Cu Wire) Cable Size; (cables per phase) Single Lug Kit of 2
Kit of 3 Cable Size; (cables per phase) Single Lug Kit of 2 Kit of 3 Cable Size; (cables per phase) Single Lug Kit of 3
Copper Body (Cu Wire Only) Cable Size; (cables per phase) Single Lug Kit of 2
Kit of 3 Cable Size; (cables per phase) Single Lug Compression Lugs Cable Size; (cables per phase) Kit of 2 Kit of 3 Cable Size; (cables per phase) Kit of 2 Kit of 3 Cable Size; (cables per phase) Kit of 3 Distribution Lugs Cable Size; (cables per phase) Single Lug Kit of 3 Cable Size; (cables per phase) Single Lug Kit of 3
#6-350 kcmil; 1-cable #14-#1; 2-hole and #14-2/0; 1-hole TA3FG20 3TA3FG20 #14-#4; 6-hole TA6FG04 3TA6FG04
Control Wire Terminals Control Wire Terminal (Single) Control Wire Terminal (Kit of 3)
17/52
Connections
Selection
List Price $
List Price $
List Price $
List Price $
List Price $
TMKJ TMKJ3
TNKL TNKL3
TNKM TNKM3
TNKP TNKP3
TNKP TNKP3
1/0-500 kcmil; 1-hole TW1JG600 3TW1JG600 3/0-250 kcmil; 2-hole TA2JG250 3TA2JG250 AL: 250-750 kcmil CU: 3/0-600 kcmil; 1-hole TA1JG750 3TA1JG750
#2-600 kcmil; 2-hole 3TA2LG600LD 3TA2LG600LN AL: 250-750 kcmil CU: 3/0-600 kcmil; 1-hole TA1JG750 (400A max) 3TA1JG750 (400A max)
500 -750 kcmil; 2-hole TA2MG750 3TA2MG750 #2-600 kcmil; 3-hole 3TA3MG600 1/0-500 kcmil; 3-hole TC3MG500
300-600 kcmil; 5; 6-hole TA5P600 TA6R600 1/0-750 kcmil; 6-hole 300-600 kcmil; 5-hole TC5R600
#6-350 kcmil; 1-cable 3CLJ350 #14-#4; 12-hole TA12JG04 3TA12JG04 #14-2/0; 6-hole TA6JG20 3TA6JG20
TA2JG250PT
3TA2LG600LNPT
TA3MG500PT
3TA4NG500PT
All lug kits include the nut keepers. Mounted on Load Side Only. Mounted on Line Side Only.
Rated 90 for 100% Applications. Requires extended modified shield. Used only with LMAP 1600 mounting base.
Used with MBPG 1600 or 1601 mounting base. CSO - Consult Sales Office for pricing.
17/53
General
Selection
Description Handle Padlocking Device To padlock breaker toggle in the OFF position. Accepts up to 3 padlocks with 58 mm shackles. Handle Blocking Device For holding the handle in the ON position. Not a lockout/tagout device. Walking-Beam Interlock Mechanism Provides mechanical interlocking between two adjacent circuit breakers. Fixed mounted breakers Note: Both breakers must be of the same frame size. Cable Interlock Mechanism Provides mechanical interlocking between 2 circuit-breakers includes operator mechanism for one circuit breaker only. Combination with the next larger or smaller frame size is possible. Interlock Cable Cable only, to connect 2 circuit breakers. Cable length 18 in. .46m (recommended up to 250A) Cable length 36 in. .91m (recommended from 400800A) Cable length 54 in. 1.37m (recommended from 12001600A) Mounting Screw Kit Includes the necessary hardware to mount a circuit breaker to the users prepared surface Kit with 2 screws (SAE thread) Kit with 4 screws (SAE thread) Kit with 4 screws (metric)
HBDF
HBDF
WBMFFM
WBMFFM
CBTF
CBTF
Trip Adjustment Sealing Cover Includes a trip unit cover to prevent tampering or adjustment of trip settings. Seal not included. Electronic Trip Units Thermal-Magnetic Trip Units
TSCPET TSCFTM
TSCPET TSCFTM
17/54
General
Selection
HBDL
HBDL
HBDM
HBDP
HBDP
WBMLFM
WBMLFM
WBMMFM
WBMPFM
WBMPFM
CBTL
CBTL
CBTM
CBTP
CBTP
CBCM36 CBCP54
CBCM36 CBCP54
CBCM36 CBCP54
CBCP54
CBCP54
MSKL4 MSKL4M
MSKL4 MSKL4M
MSKM4 MSKM4M
MSKP4 MSKP4M
MSKP4 MSKP4M
TSCPET TSCLTM
TSCPET TSCLTM
TSCPET TSCMTM
TSCPET
TSCPET
17/55
Description Neutral Current Transformer (Ground Sensor, N-pole) Neutral = 35/60A Neutral = 100A Neutral = 150A Neutral = 250A Neutral = 400A Neutral = 600A Neutral = 800A Neutral = 1000/1200A Neutral = 1600A Communications & Electronics Power Stick - Hand held, battery operated power supply for LCD trip units. (Requires two -9V batteries) For programming and trip testing only. Test Kit - Portable power supply for programming, trip test, and checking CTs plus a port for local communications of currents flow and trip settings. (Requires two 9V batteries) Universal Power Supply - 120/240Vac adapter used in lieu of 9V batteries for Test Kit ELTPHB (includes necessary cables) Power Supply with ZSI (for Model 576 trip units only). Com10 Profibus Communications Module with ZSI for LCD trip Model 576 only
List Price $
List Price $
EPSP18V
EPSP18V
ELTPHB
ELTPHB
UPAPELTK
UPAPELTK
COMPS COMPRO
COMPS COMPRO
RS232 Cable
Com11 Modbus Communications Module with ZSI for LCD Trip Model 576 only Communications Adapter - Interface with a laptop or PC to test or program Model 545 & 576 trip units Cable for COM10/11 and Model 576 external power supply5ft. (1.5m) Extension cable for COMKIT1 & COMKIT2, adds 5 ft.
COMMOD
COMMOD
CSAPELTU
CSAPELTU
COMKIT1
COMKIT1
Spare flat cable for Test Kits or Communications Adapters RS232 type cable for Test Kits or Communications Adapters
For breakers with stored energy operator. (IP40) Circuit-breaker draw-out mounted and toggle handle operated. Kit includes cover frame (bezel) and escutcheon as needed. (IP40) (not for use with rotary handle or stored energy operator)
BZLFRHSE
BZLFRHSE
BZLFBDC
BZLFBDC
Toggle Handle Extension For spare or replacement. (One is included with each NG - PG frame.)
17/56
List Price $
EPSP18V
EPSP18V
EPSP18V
EPSP18V
EPSP18V
ELTPHB
ELTPHB
ELTPHB
ELTPHB
ELTPHB
UPAPELTK
UPAPELTK
UPAPELTK
UPAPELTK
UPAPELTK
COMPS COMPRO
COMPS COMPRO
COMPS COMPRO
COMPS COMPRO
COMPS COMPRO
COMMOD
COMMOD
COMMOD
COMMOD
COMMOD
CSAPELTU
CSAPELTU
CSAPELTU
CSAPELTU
CSAPELTU
COMKIT2
COMKIT2
COMKIT2
COMKIT1
COMKIT1
BZLL3
BZLL3
BZLM3
BZLP3
BZLP3
BZLLRHSE
BZLLRHSE
BZLMRHSE
BZLPRHSE
BZLPRHSE
BZLLBDC
BZLLBDC
BZLMBDC
BZLPBDC
BZLPBDC
THEL
THEL
THEM
THEP
THEP
17/57
Accessory Locations
Selection
Up to 3 Auxiliary Switches
Up to 4 Auxiliary Switches
* Except DG and FG breakers with Electronic Trip Units. Due to the location of the Magnetic Latch, the Left Pocket is not available for accessories.
Accessory Information Aux. Switch is an Auxiliary Switch, 1A or 1B contact Alarm Switch has 1A or 1B contact UVR is an Undervoltage Release The standard location for factory mounted Auxiliary and Alarm Switches is the Left Pocket
Accessory Maximums
DG, FG, JG, LG Maximum Accessories:
Maximum of six (6) switches total DG, FG Maximum of two (2) Alarm Switches, one each in the Left and Right Pockets. JG, LG Max. of 1 Alarm, Left only
MG, NG, PG Maximum Accessories:
Maximum of eight (8) switches total Maximum of two (2) Alarm Switches, Left Pocket only
17/58
DG, FG, JG or LG
A3
ASKL3
MG, NG or PG
A3
ASKP3
MG, NG or PG
A4
ASKP4
DG, FG, JG or LG
MG, NG or PG
DG, FG, JG or LG
MG, NG or PG
17/59
Technical Data
Selection
DG
Max rated continuous current Rated operational voltage NEMA IEC Rated Impulse Withstand Voltage Main conducting paths Auxiliary circuits Ambient Temperature Range High Ambient Derating (thermal-mag.) 150 V AC V AC kV kV C 50C 60C 70C 600 690 8 4 -25 to +75 93% 86% 80% 20,000 120 15 48 40
FG
250 600 690 8 4 -25 to +75 93% 86% 80% 20,000 120 32 80 60
JG
400 600 690 8 4 -25 to +75 93% 86% 80% 20,000 120 60 175 90
LG
600 600 690 8 4 -25 to +75 93% 86% 80% 10,000 60 85 230 160
MG
800 600 690 8 4 -25 to +75 95% 86% 80% 5,000 60 170 250 250
NG
1200 600 690 8 4 -25 to +75 95% 86% 80% 3,000 30 150 220 210
PG
1600 600 690 8 4 -25 to +75 95% 80% 74% 3,000 30 200 260 260
Operating Cycles Max switching rate (per hour) Power loss (at max. rated current) Thermal-magnetic W Electronic trip unit W IEC Time constant t = 10 ms 1 current path 2 current paths 3 current paths in series in series Up to 250V DC 440V DC 600V DC NEMA Time constant t = 8 ms 2 poles switching 1 current path 250V DC Max. 3 poles switching 2 current paths in series 500V DC Max. Accessories Auxiliary / Alarm Switch Current rating (1 or 2 switches) Current rating (3 or 4 same switch) A Shunt Trip Pick-up voltage Power Consumption (short-time) at: 48 60 V AC 110 127 V AC 208 277 V AC 380 600 V AC 24 V DC 48 60 V DC 110 127 V DC 220 250 V DC Max. Operating time
Consult Siemens for short circuit values. Review individual frame and type values.
30 18
30 25
30 35
30 35
42 65
42 65
42 65
10 5 0.7 1.1 401 501 424 489 533 736 408 645 594 740 925 559 648 722 820 50
10 5 0.7 1.1 401 501 424 489 533 736 408 645 594 740 925 559 648 722 820 50
10 5 0.7 1.1 401 501 424 489 533 736 408 645 594 740 925 559 648 722 820 50
10 5 0.7 1.1 401 501 424 489 533 736 408 645 594 740 925 559 648 722 820 50
10 5 0.7 1.1 401 501 424 489 533 736 408 645 594 740 925 559 648 722 820 50
10 5 0.7 1.1 401 501 424 489 533 736 408 645 594 740 925 559 648 722 820 50
10 5 0.7 1.1 401 501 424 489 533 736 408 645 594 740 925 559 648 722 820 50
V VA VA VA VA W W W W ms
17/60
Technical Data
Selection
PG
35% 70% 70% 85% 1.1 2.1 1.2 1.4 1.9 2.2 2.5 2.8 50
DG
Undervoltage Trip Drop voltage (percentage) Pick-up voltage (percentage) Power consumption (continuous) at: 110 127 V AC 220 250 V AC 208 V AC 277 V AC 380 415 V AC 440 480 V AC 500 525 V AC 600 V AC Max. opening time Motorized Operating Mechanism Motor with stored energy mechanism (synchronizable) Motor Operator Max. switching rate (per hour) Command duration Closing time Charging time Break time Power consumption Inrush (A) Control Voltages 110 127 V AC 220 250 V AC 24 V DC 48 V DC 60 V DC V V VA VA VA VA VA VA VA VA ms
FG
JG
LG
35% 70% 70% 85% 1 2.1 1.2 1.4 1.9 2.2 2.5 2.8 50
MG
NG
35% 70% 35% 70% 35% 70% 70% 85% 70% 85% 70% 85% 1 2.1 1.2 1.4 1.9 2.2 2.5 2.8 50 1 2.1 1.2 1.4 1.9 2.2 2.5 2.8 50 1 2.1 1.2 1.4 1.9 2.2 2.5 2.8 50
35% 70% 35% 70% 70% 85% 70% 85% 1.1 2.1 1.2 1.4 1.9 2.2 2.5 2.8 50 1.1 2.1 1.2 1.4 1.9 2.2 2.5 2.8 50
X 60 20 50 <100 <5 <5 X 60 20 50 <100 <5 <5 X 30 <5,000 <5 <5 X 30 <5,000 <5 <5
ms ms s s VA/W
17/61
Note: The information provided on this and the next page is intended for reference and recommendation only. Because several variables can act on a circuit breakers performance at the same time, the data below is based less on controlled testing, than on experience and engineering judgment. Contact Siemens for further information on special conditions and treatment. High Ambient Temperatures Because thermal-magnetic trip breakers are temperature sensitive and calibrated for a specific ambient of 40 C (104 F) (average enclosure temperature), a higher ambient will cause the breaker to trip at lower current than its nameplate rating, in other words, causing the breaker to derate (see Table 1). Similarly, the current carrying capacity of a circuit conductor is based upon a certain ambient temperature, a higher ambient will reduce its current carrying capacity, causing it to derate. Thus, with a fluctuating temperature, a thermal-magnetic breaker will derate nearly parallel with its connected circuit conductors and maintain close circuit protection. If the application temperature exceeds 40 C (104 F) and is known, either a breaker specially calibrated for the higher ambient or one oversized according to Table 1 may be selected. In a case such as this, the circuit conductors should be oversized as well. Siemens Electronic Trip Unit Breakers are insensitive to temperature changes. However, they do include circuitry to protect the components from abnormally high temperatures. Moisture Corrosion For atmospheres having high moisture content and / or where fungus growth is prevalent, a special preventive treatment may be required. Where the air is heavily laden with corrosive elements, breakers made with special corrosion-resistant finishes may be required. Altitude Reduced air density at altitudes greater than 6600 ft. (2000 meters) affects the ability of a molded case circuit breaker to transfer heat and interrupt faults. Therefore, circuit breakers applied at these altitudes should have interrupting, insulation and continuous currents derated as indicated in Figure 1. Table 1 Temperature Derating Data for Thermal-Magnetic Breakers
Reference Ampere Rating at 40 C (104 F) 0015 0020 0025 0030 0035 0040 0050 0060 0070 0090 0100 0125 0150 0175 0200 0225 0250 0300 0350 0400 0500 0600 0700 0800 0900 1000 1200 1400 1600 1800 2000 Ampere Rating at: 25 C 50 C (77 F) (122 F) 0017 0013 0022 0018 0028 0023 0033 0028 0039 0030 0044 0037 0055 0046 0066 0056 0077 0065 0099 0084 0110 0094 0137 0114 0165 0136 0192 0159 0220 0182 0247 0205 0275 0235 0330 0276 0385 0325 0440 0372 0550 0468 0660 0564 0770 0658 0880 0754 0990 0828 1100 0900 1320 1090 1540 1304 1760 1500 1980 1690 2200 1880
60 C (140 F) 0011 0016 0021 0026 0025 0034 0042 0052 0060 0078 0087 0100 0120 0140 0160 0180 0220 0252 0301 0340 0435 0525 0613 0704 0749 0825 1000 1148 1320 1485 1650
Siemens Breaker Frames BQ, BL, BQD, CQD, NGG, NGB, EG, EB DG
FG
JG
LG MG
NG
PG
13,000 (4,000) Altitude in Feet (Meters) 12,000 (3,675) 11,000 (3,350) 10,000 (3,000) 9,000 (2,750) 8,000 (2,400) 7,000 (2,100) 6,000 (1,800) 1.0 .95 .90 .85 .80 .75
17/62
Ordering Instructions
All ED Frame Sentron circuit breakers are supplied with load side lugs. If line side lugs are required, add L suffix to catalog number. Consult Siemens sales office for any addditional charge 50C Calibration, 400HZ - see page 17/110. All ED frame circuit breakers may be reverse connected
Type ED2
1-Pole Continuous Current Rating @ 40 C 015 020 25 030 35 040 45 050 060 070 80 90 100 120V AC Catalog Number ED21B015 ED21B020 ED21B025 ED21B030 ED21B035 ED21B040 ED21B045 ED21B050 ED21B060 ED21B070 ED21B080 ED21B090 ED21B100 2-Pole 125V DC 240V AC List Price $ Catalog Number ED22B015 ED22B020 ED22B025 ED22B030 ED22B035 ED22B040 ED22B045 ED22B050 ED22B060 ED22B070 ED22B070 ED22B090 ED22B100 3-Pole
Blue Label
125V DC 250V DC 240V AC List Price $ Catalog Number ED23B015 ED23B020 ED23B025 ED23B030 ED23B035 ED23B040 ED23B045 ED23B050 ED23B060 ED23B070 ED23B080 ED23B090 ED23B100 List Price $
Shipping Weights
Number of Poles 1 2 3 CED6 2 3 5 5 20 30 Number per Carton 30 10 10 Shipping Weight (lbs.) 38 25 38 ED2, ED4, ED6, HED4, HHED6
Lugs
Ampere Rating No. of Poles Catalog Number Line/Load SA1E025 Line Side LN1E100 Load Side LD1E060 Load Side LD1E100 Load Side LN1E100 Line/Load TA1E6125 Line/Load TC1ED6150 CCE125 Wire Range #14#10 Cu #12#10 Al #101/0 Cu/Al #10#4 Cu/Al #6#1/0 Cu/Al #101/0 Cu/Al #33/0 Cu #12/0 Al Aluminum Body Lugs All 1525A All 30100A 1, 2, 3 1, 2, 3
Type ED4
1-Pole Continuous Current Rating @ 40 C 015 020 025 030 035 040 045 050 060 070 080 090 100 110 125 120V AC 277V AC Catalog Number ED41B015 ED41B020 ED41B025 ED41B030 ED41B035 ED41B040 ED41B045 ED41B050 ED41B060 ED41B070 ED41B080 ED41B090 ED41B100 125V DC List Price $ 2-Pole 480V AC Catalog Number ED42B015 ED42B020 ED42B025 ED42B030 ED42B035 ED42B040 ED42B045 ED42B050 ED42B060 ED42B070 ED42B080 ED42B090 ED42B100 ED42B110 ED42B125 3-Pole
Blue Label
250V DC 480V AC List Price $ Catalog Number ED43B015 ED43B020 ED43B025 ED43B030 ED43B035 ED43B040 ED43B045 ED43B050 ED43B060 ED43B070 ED43B080 ED43B090 ED43B100 ED43B110 ED43B125 List Price $
ED2, 4, CED6 1 3060A ED2, 4, CED6 1 70100A ED2, 4, 6, HED4, HHED6 2, 3 30100A All 110, 125A 2, 3
2/0
Type ED6
1-Pole Continuous Current Rating @ 40 C 015 020 025 030 035 040 045 050 060 070 080 090 100 110 125 347V AC Catalog Number ED61B015 ED61B020 ED61B025 ED61B030 ED61B035 ED61B040 ED61B040 ED61B050 ED61B060 ED61B070 ED61B080 ED61B090 ED61B100 List Price $ 2-Pole 600V AC Catalog Number ED62B015 ED62B020 ED62B025 ED62B030 ED62B035 ED62B040 ED62B045 ED62B050 ED62B060 ED62B070 ED62B080 ED62B090 ED62B100 250V DC List Price $ 3-Pole
Blue Label
600V AC Catalog Number ED63B015 ED63B020 ED63B025 ED63B030 ED63B035 ED63B040 ED63B045 ED63B050 ED63B060 ED63B070 ED63B080 ED63B090 ED63B100 ED63B110 ED63B125 500V DC List Price $
Note: ED frame circuit breakers qualified to UL 489 Supplement SB Naval See page 17/110 for additional information Built to order. Allow 23 weeks for delivery.
CSA Certified only (Not UL) For CED types and all 110125 ampere ED frames. See Note: A, page 17/100. SWD rated. HACR rated.
17/63
Type HED4
1-Pole Continuous Current Rating @ 40 C 015 020 025 030 035 040 045 050 060 070 080 090 100 110 125 277V AC Catalog Number HED41B015 HED41B020 HED41B025 HED41B030 HED41B035 HED41B040 HED41B045 HED41B050 HED41B060 HED41B070 HED41B080 HED41B090 HED41B100 125V DC List Price $ 2-Pole 480V AC Catalog Number HED42B015 HED42B020 HED42B025 HED42B030 HED42B035 HED42B040 HED42B045 HED42B050 HED42B060 HED42B070 HED42B080 HED42B090 HED42B100 HED42B110 HED42B125 250V DC List Price $ 3-Pole 480V AC Catalog Number
Black Label
List Price $ D1 H
HED43B015 HED43B020 HED43B025 HED43B030 HED43B035 HED43B040 HED43B045 HED43B050 HED43B060 HED43B070 HED43B080 HED43B090 HED43B100 HED43B110 HED43B125
W3 W1 W2
1-POLE
2-POLE
3-POLE
Type HHED6
Continuous Current Rating @ 40C 015 020 025 030 035 040 045 050 060 070 080 090 100 110 125
Black Label
D1 H
2-Pole 3-Pole 2-Pole 600V AC 600V AC 600V AC, 250V DC Catalog List Catalog List Catalog List Number Price $ Number Price $ Number Price $ HHED63B015A CED62B015 HHED62B015 HHED62B020 HHED63B020 CED62B020 HHED62B025 HHED63B025 HHED62B030 HHED63B030 CED62B030 HHED62B035 HHED63B035 HHED62B040 HHED63B040 CED62B040 HHED62B045 HHED63B045 HHED62B050 HHED63B050 CED62B050 HHED62B060 HHED63B060 CED62B060 HHED63B070 CED62B070 HHED62B070 HHED62B080 HHED63B080 CED62B080 HHED62B090 HHED63B090 CED62B090 HHED62B100 HHED63B100 CED62B100 HHED63B110 HHED62B110 HHED62B125 HHED63B125 CED62B125
W2, W3
Interrupting Ratings
Breaker Type ED2 (1-P) ED2 (2, 3-P) ED4 (1-P) ED4 (2, 3-P) ED6 (1P) ED6 (2, 3-P) HED4 (1-P) (1530A) HED4 (1-P) (35100A) HED4 (2, 3-P) HHED6 (2, 3-P) CED6 (2, 3-P) UL 489 AIR (File #E10848) RMS Symmetrical Amperes (KA) Volts AC 120 240 277 347 480 010 010 065 22 065 18 30 065 25 100 100 100 100 200 65 25 42 0 650 200 Volts DC 125 250 05 05 (2-P) 30 30 (2-P) 30 30 30 (2-P) 50 (2-P) IEC 947-2 Volts AC (50/60Hz) 220/240 380/415 lcu lcs lcu lcs 65 17 35 9 500 lcu 18
600 18 18 100
lcs 5
Built to order. Allow 23 weeks for delivery. SWD rated. When wired as shown on page 17/5, this circuit breaker is UL listed and rated for use on 500V DC ungrounded UPS systems.
HED4 and HHED6 type circuit breakers meet the UL criteria for current limiting at 240V AC. ED6-ETI, CED6-ETI, see page 17/88 for ordering information.
Single Pole 15-30A 30KA @ 347V non-UL. 35-100A 18KA @ 347V non-UL. HACR rated. HHED63B015A is rated 18KAIC at 600/347V.
17/64
Accessories
Selection
Accessories for:
ED 125A Frame
024 048 120 208 240 277 480 012 024 048 125 250
List Price $:
S17ED60 S18ED60 S01ED60 S03ED60 S15ED60 S04ED60 S16ED60 S07ED60 S09ED60 S11ED60 S13ED60
S01ED62A S02ED62A S03ED62A S15ED64A S04ED64A S16ED62A S07ED62A S09ED62A S11ED62A S13ED62A
Combinations
Available only when ordered together. Only one module can be added to a breaker. Additional accessories, which always attach to the left pole, cannot be added to the combination later. Adds 1 inch pole space.
120 208 240 277 480 600 024 048 125 250
List Price $:
U01ED60 U02ED60 U03ED60 U16ED60 U06ED60 U08ED60 U13ED60 U14ED60 U10ED60 U12ED60
240 480
250
A01ED62 A01ED64
A01ED62B A01ED64B
A02ED62
A02ED62B
List Price $: Maximum Voltage AC DC 1 Auxiliary Switch Catalog Number List Price $
12
A01EDLV
240 480
250
B00ED62 B00ED64
Basic Kit CED6, ED2, ED4 ED6, EFC, EFF, HED4, HHED6 1, 2, 3 Basic Kit with Normally Open Bell Alarm Basic Kit with Normally Closed Bell Alarm
17/65
Accessories
Selection
Type FXD6-A
Continuous Current Rating @ 40C 70 80 90 100 110 125 150 175 200 225 250 2-Pole Catalog Number FXD62B070 FXD62B080 FXD62B090 FXD62B100 FXD62B110 FXD62B125 FXD62B150 FXD62B175 FXD62B200 FXD62B225 FXD62B250 List Price $
Blue Label
3-Pole Catalog Number FXD63B070 FXD63B080 FXD63B090 FXD63B100 FXD63B110 FXD63B125 FXD63B150 FXD63B175 FXD63B200 FXD63B225 FXD63B250
Ordering Information
Complete Breaker Unassembled with Lugs Prices of FD6, HFD6, and HHFD6 breakers includes frame, trip and both line and load lugs (TA1FD350A). When ordered by these catalog numbers, the customer will receive the frame, trip, and lugs separately packaged. For applications requiring different lugs, order individual items as needed. Complete Breaker Assembled without Lugs Prices of FXD6, HFXD6, HHFXD6, and CFD6 includes frame with non-interchangeable trip unit installed only. Order required lugs separately. For line and load lugs (TA1FD350A) installed, add suffix L to catalog number (add 2 times list price of lugs for each pole). 50C Applications see page 17/110. 400 Hz Applications see page 17/110.
Type FD6-A
Interchangeable Trip
Continuous Current Rating @ 40C Complete Breaker Unassembled with Lugs Catalog List Number Price $ Frame Only Catalog Number List Price $
Blue Label
FD62F250
FD63F250
Enclosures
Type 1 3R 4-4X 7-9 12 Neutral 500 lcu 20 42 65 Catalog Number F6N1S(F) F6N3R FD6SS4 EC2 F6N12 N250 List Price $
Interrupting Ratings
RMS Symmetrical Amperes (KA) UL 489 AIR (File E10848) Volts AC (50/60Hz) Volts DC 240 480 600 250 500 65 100 200 200 35 65 100 200 22 25 25 100 30 (2-P) 30 (2-P) 30 (2-P) 18 (3-P) 25 (3-P) 50 (3-P) IEC 947-2 Volts AC (50/60Hz) 220/240 380/415 lcu lcs lcu lcs 65 33 35 9 100 50 65 33 200 100 100 50
lcs 10 21 33 Modifications page 17/110 Accessories pages 17/68 and 17/103 to 17/108
Built to order. Allow 23 weeks for delivery. Type FXD6-A circuit breakers are UL Listed for reverse fed applications. 2-pole units are 3-pole width. When wired as shown on page 17/5, this circuit breaker is UL listed and rated for use on 500V DC ungrounded UPS systems only. Order neutral as separate item. See Note: A, page 17/100. HFD6 and HHFD6 type circuit breakers meet the UL criteria for current limiting at 240 and 480V AC. HACR rated.
Note: FD frame qualified to UL489 supplement SB NAVAL. See page 17/110 for additional information.
17/66
Black Label
D1
HFD62F250
Figure 1
Figure 2
HFD63F250
4.50
09.50
5.25
4.50
14.25
5.25
Shipping Weights
Number of Number per Shipping Poles Carton Weight (lbs.) FD6-A, HFD6, HHFD6, FXD6-A Assembled Circuit Breaker (less connectors) 2 1 08.6 3 1 10 FD6-A, HFD6, HHFD6 Frame Only 2 1 07.5 3 1 08.7 FD6 Trip Unit Only 2 1 01.1 3 1 01.3 CFD6 Assembled Circuit Breaker (less terminals) 2 1 31 3 1 34
HHFD63F250
Type CFD6
Fuseless Current Limiting
3-Pole Continuous Current Rating @ 40C 070 080 090 100 110 125 150 175 200 225 250 600V AC/500V DC Catalog Number CFD63B070 CFD63B080 CFD63B090 CFD63B100 CFD63B110 CFD63B125 CFD63B150 CFD63B175 CFD63B200 CFD63B225 CFD63B250
Red Label
List Price $
Built to order. Allow 23 weeks for delivery. When wired as shown on page 17/5, this circuit breaker is UL listed and rated for use on 500V DC ungrounded UPS systems. For non-interchangeable trip 3-pole HFD6 type circuit
breaker, change prefix identifier from HFD6 to HFXD6. Price equals frame and trip prices combined, e.g. price of HFXD63B250 equals price of HFD63F250 plus price of FD63T250. Order lugs separately. Type HFXD6, HHFXD6, CFD6 are UL Listed for reverse feed applications.
Type HFXD6, HFD6, HHFD6, HHFXD6 meet the UL criteria for Current Limiting at 240 VAC and 480V AC. FXD6, ETI, CFD6, ETI See page 17/88 for ordering information. HACR rated.
17/67
Internal Accessories
Selection
Accessories:
for FD, FFC & FFF 250A Frames
024 120 240 277 480 600 012 024 048 125 250
S17FD60 S01FD60 S03FD60 S15FD60 S04FD60 S06FD60 S16FD60 S07FD60 S09FD60 S11FD60 S13FD60
120 208 240 277 480 600 024 048 125 250
U01FD60 U02FD60 U03FD60 U16FD60 U06FD60 U08FD60 U13FD60 U14FD60 U10FD60 U12FD60
240 480 12
480
250
B00FD64
C01FD64
Built to order. Allow 68 weeks for delivery. Auxiliary switch application is for 480V AC maximum. Note: Old F-frame accessories cannot be used in new Sentron line. Likewise, new FD-frame accessories cannot be used on old F-frame circuit breakers.
17/68
Type JXD2-A
240V AC , 2-Pole 250V DC Only
Continuous Current Rating @ 40C 200 225 250 300 350 400 2-Pole (3-Pole Width) Catalog List Number Price $ JXD22B200 JXD22B225 JXD22B250 JXD22B300 JXD22B350 JXD22B400
Blue Label
3-Pole List Price $
Type JXD6-A
Blue 600V AC , 2-Pole 250V DC, 3-Pole 500V DC Non-Interchangeable Trip (Assembled Circuit Breaker without Lugs)
200 225 250 300 350 400 JXD62B200 JXD62B225 JXD62B250 JXD62B300 JXD62B350 JXD62B400 JXD63B200 JXD63B225 JXD63B250 JXD63B300 JXD63B350 JXD63B400
Label
Type JD6-A
Interchangeable Trip
Continuous Current Rating @ 40C 200 225 250 300 350 400 200 225 250 300 350 400 Complete Breaker Unassembled with Lugs Catalog List Number Price $ JD62B200 JD62B225 JD62B250 JD62B300 JD62B350 JD62B400 JD63B200 JD63B225 JD63B250 JD63B300 JD63B350 JD63B400 Frame Only Catalog Number List Price $
Blue Label
Trip Unit Only Catalog List Number Price $ JD62T200 JD62T225 JD62T250 JD62T300 JD62T350 JD62T400 JD63T200 JD63T225 JD63T250 JD63T300 JD63T350 JD63T400
Interrupting Ratings
RMS Symmetrical Amperes (KA) UL 489 AIR (File E10848) Volts AC Volts DC (50/60Hz) 240 065 065 100 200 200 480 035 065 100 150 600 025 035 050 100 250 30 (2-P) 30 (2-P) 30 (2-P) 50 (2-P) 500 25 (3-P) 35 (3-P) 50 (3-P) IEC 947-2 Volts AC (50/60Hz) 220/240 380/415 lcu 065 100 200 lcs 033 050 100 lcu 040 065 100 lcs 20 33 50
Breaker Type JXD2-A JXD6-A, JD6-A HJD6-A, HJXD6-A HHJD6, HHJXD6 CJD6-A
5 1960 3140
6 2140 3430
7 2320 3710
Built to order. Allow 23 weeks for delivery. Type JXD2 and JXD6 circuit breakers are UL Listed for reverse feed applications. When wired as shown on page 17/5, this circuit breaker is UL listed and rated for use on 500V DC ungrounded UPS systems only.
See Note: A, page 17/100. HHJD6 type circuit breakers meet the UL criteria for current limiting at 240 and 480V AC. HACR rated. Note: JD frame qualified to UL489 supplement B NAVAL. See page 17/110 for additional information.
17/69
Black Label
D1 Trip Unit Only Catalog Number List Price $ L L
HJD62F400
Figure 1
Figure 2
HJD63F400
Black Label
HHJD62F400 JD62T200 JD62T225 JD62T250 JD62T300 JD62T350 JD62T400
Figure 1 JXD2-A, JXD6-A, JD6-A HJD6-A, HJXD6-A, HHJD6, 7.5 11 HJD6, HJXD6, HHJXD6, JXD6-ETI , SJD6, SHJD6 Figure 2 CJD6, CJD6-ETI , SCJD6 7.5 17.86
3-Pole 600VAC
200 225 250 300 350 400 HHJD63B200 HHJD63B225 HHJD63B250 HHJD63B300 HHJD63B350 HHJD63B400 JD63T200 JD63T225 JD63T250 JD63T300 JD63T350 JD63T400
HHJD63F400
Type CJD6-A
Fuseless Current Limiting
2-Pole Continuous Current Rating @ 40C 200 225 250 300 350 400 600V AC/250V DC 3-Pole
Red Label
Shipping Weights
Number of Number per Shipping Poles Carton Weight (lbs.) JXD2, JXD6, JD6, HJD6, HHJD6 Assembled Breaker (less terminals) 2 1 17.5 3 1 19.5 JD6, HJD6, HHJD6 Frame Only 2 1 14 3 1 15.5 JD6 Trip Unit Only 2 1 03.5 3 1 04 CJD6 Complete Assembled Breaker (less terminals) 2 1 29.5 3 1 31.5
For inches / millimeters conversion, see Application Data section. Built to order. Allow 23 weeks for delivery. 2-pole units available in 3-pole construction. When wired as shown on page 17/5, this circuit breaker is UL listed and rated for use on 500V DC ungrounded UPS systems only. For non-interchangeable 3-pole HJD6 or HHJD6 type circuit breaker change the prefix identifier to HJXD6 or HHJXD6. Price equals price of frame plus price of trip, e.g. price of HJXD63B400 equals price of HJD63F400 plus price of JD63T400. Order lugs separately. JXD6-ETI, CJD6-ETI see page 17/88 for ordering information. Type HJXD6, HHJXD6 Circuit Breakers are UL listed for reverse fed applications. CE applies to non-interchangeable type HJXD6-A only. HACR rated.
17/70
5.44
5.44
SJD 400A Frame, Digital Solid State Sentron Sensitrip III Series
Selection
Current Limiting
Ordering Information
Pricing information for all Digital Sentron Series SJD frames is for complete breaker only price required lugs as separate items lugs are suitable for 75 C wire. SJD6 and SCJD6 are acceptable for reverse connection application. SHJD6 are not acceptable for reverse connection application.
Type SJD6-A
Blue Label
3-Pole, 600V AC Catalog Number SJD69200 SJD69300 SJD69400 SJD69200G SJD69300G SJD69400G SJD69200NT SJD69300NT SJD69400NT SJD69200NGT SJD69300NGT SJD69400NGT Max Current List Rating Price $ 200 300 400 200 300 400 200 300 400 200 300 400
Type SHJD6-A
Black Label
3-Pole, 600V AC Catalog Number SHJD69200 SHJD69300 SHJD69400 SHJD69200G SHJD69300G SHJD69400G SHJD69200NT SHJD69300NT SHJD69400NT SHJD69200NGT SHJD69300NGT SHJD69400NGT Max Current List Rating Price $ 200 300 400 200 300 400 200 300 400 200 300 400
Type SCJD6-A
Red Label
3-Pole, 600V AC Catalog Number SCJD69200 SCJD69300 SCJD69400 SCJD69200G SCJD69300G SCJD69400G SCJD69200NT SCJD69300NT SCJD69400NT SCJD69200NGT SCJD69300NGT SCJD69400NGT Max Current List Rating Price $ 200 300 400 200 300 400 200 300 400 200 300 400
Shipping Weights
Breaker Type SJD6-A SHJD6-A SCJD6-A Number per Carton 1 1 1 Shipping Weight (lbs) 20 20 33
Type SHJD6-A
Black Label
3-Pole, 600V AC Catalog Number SHJD69200H SHJD69300H SHJD69400H SHJD69200GH SHJD69300GH SHJD69400GH SHJD69200NTH SHJD69300NTH SHJD69400NTH SHJD69200NGTH SHJD69300NGTH SHJD69400NGTH Max Current List Rating Price $ 200 300 400 200 300 400 200 300 400 200 300 400
Neutral Transformers
Ampere Rating 200 300 400 Ground Fault Pick Up Ground Fault Delay Catalog Number N02SJD N03SJD N04SJD List Price $
Interrupting Ratings
Breaker Type SJD6-A SHJD6-A SCJD6-A RMS Symmetrical kA UL 489 (File E10848) 240V AC 065 100 200 480V AC 035 065 150 600V AC 025 035 100
Note: G suffix in catalog number denotes circuit breaker for 3-phase, 3-wire systems. For 3-phase, 4-wire, order correct 4th wire (neutral) transformer as separate and additional item.
Built to order. Allow 23 weeks for delivery. For additional information, see Note: A, page 17/100. Refer to the NEC for proper app lication of 100% rated devices.
17/71
Type LXD6-A
2-Pole (3-Pole Width) 600V AC 250V DC Catalog List Number Price $ LXD62B450 LXD62B500 LXD62B600
Blue Label
3-Pole 600V AC Catalog Number LXD63B450 LXD63B500 LXD63B600
Ordering Information
Complete Breaker Unassembled with Lugs Prices of LD6, HLD6, and HHLD6 breakers include frame, trip, and both line and load lugs (TA2J6500). When ordered by these catalog numbers, the customer will receive the frame, trip and lugs separately packaged. For applications requiring different lugs, order individual items as needed. Complete Breaker Assembled without Lugs Prices of LXD6, HLXD6, HHLXD6, and CLD6 include frame with noninterchangeable trip unit installed only. Order required lugs separately. For line and load lugs (TA2J6500) installed, add suffix L to catalog number (add 2 times list price of lugs for each pole). 100% Rated Types LXD6 and HLXD6 breakers are available with 100% ratings. To order add suffix H to catalog number, and 10% to list price. 100% rated LD breakers require the use of 90C Cu cable sized at 75C ampacity and lugs TC1J6600 or TC2J6500. 50C Applications see page 17/110. 400Hz Applications see page 17/110.
Type LD6-A
Interchangeable Trip
Continuous Current Rating @ 40C 250 300 350 400 450 500 600 Complete Breaker Unassembled w/Lugs Catalog List Number Price $ LD62B250 LD62B300 LD62B350 LD62B400 LD62B450 LD62B500 LD62B600 Frame Only Catalog Number List Price $
Blue Label
Trip Unit Only Catalog List Number Price $ JD62T250 JD62T300 JD62T350 JD62T400 LD62T450 LD62T500 LD62T600
LD62F600
LD63F600
Interrupting Ratings
Breaker Type LD6-A, LXD6-A HLD6-A, HLXD6-A HHLD6, HHLXD6 CLD6-A RMS Symmetrical Amperes (KA) UL 489 AIR (File E10848) Volts AC (50/60Hz) Volts DC 240 065 100 200 200 480 035 065 100 150 600 025 035 050 100 250 30 (2-P) 30 (2-P) 500 IEC 947-2 Volts AC (50/60Hz) 220/240 (lcu) (lcs) 25 (3-P) 065 033 35 (3-P) 100 050 200 100 50 (3-P) 380/415 (lcu) (lcs) 040 20 065 33 100 50 500 (lcu) 30 42 65 (lcs) 15 21 33
Shipping Weights
Number of Number per Shipping Poles Carton Weight (lbs.) LXD6, LD6, HLD6, HHLD6 Assembled Breaker (less terminals) 2 1 17.5 3 1 19.5 LD6, HLD6, HHLD6 Frame Only 2 1 14 3 1 15.5 LD6, HHLD6 Trip Unit Only 2 1 03.5 3 1 04 CLD6 Complete Assembled Breaker (less terminals) 2 3 1 1 29.5 31.5
Built to order. Allow 23 weeks for delivery. Type LXD6A circuit breakers are UL Listed for reverse fed applications. When wired as shown on page 17/5, this circuit breaker is UL listed and rated for use on 500V DC ungrounded UPS systems only. See Note: A, page 17/100. HACR rated. Note: LD frame qualified to UL489 supplement SB NAVAL. See page 17/110 for additional information.
17/72
Black Label
D1
HLD62F600
Figure 1
Figure 2
HLD63F600
Black Label
JD62T250 JD62T300 JD62T350 JD62T400 HHLD62T450 HHLD62T500 HHLD62T600
HHLD62F600
Figure 1 LXD6-A, LD6-A HLD6-A HHLD6, HHLXD6, LXD6ETI, SLD6, SHLD6 Figure 2 CLD6, CLD6-ETI, SCLD6
7.5 11
5.44
7.5 17.86
5.44
3-Pole 600V AC
250 300 350 400 450 500 600 HHLD63B250 HHLD63B300 HHLD63B350 HHLD63B400 HHLD63B450 HHLD63B500 HHLD63B600 JD63T250 JD63T300 JD63T350 JD63T400 HHLD63T450 HHLD63T500 HHLD63T600
HHLD63F600
Type CLD6-A
Fuseless Current Limiting Non-Interchangeable Trip (Assembled Circuit Breaker)
2-Pole Continuous Current Rating @ 40C 450 500 600 600V AC/250V DC 3-Pole
Red Label
For inches / millimeters conversion, see Application Data section. Built to order. Allow 23 weeks for delivery. When wired as shown on page 17/5, this circuit breaker is UL listed and rated for use on 500V DC ungrounded UPS systems only. For complete assembled 3-pole HLD6 or HHLD6 type circuit breaker change the prefix identifier HLD6 or HHLD6 to HLXD6 or HHLXD6. Price is sum of frame and trip units prices, e.g. price of HLXD63B400 is the price of HLD63F600 plus the price of LD63T600. Order the terminal connectors separately. Type HLXD6, HHLXD6, & CLD6 Circuit Breakers are UL Listed for reverse feed applications. LXD6-ETI, CLD6-ETI see page 17/88 for ordering information. CE Applies to non-interchangeable type HLXD only. HACR rated.
17/73
SLD 600A Frame, Digital Solid State Sentron Sensitrip III Series
Selection
Current Limiting
Ordering Information
Pricing information for all Digital Sentron Series SLD frames is for complete breaker only price required lugs as separate items lugs are suitable for 75 C wire. SLD6 and SCLD6 are suitable for reverse connection application. SHLD6 are not suitable for reverse connection application.
Type SLD6-A
Blue Label
3-Pole, 600V AC Catalog Number SLD69300 SLD69400 SLD69500 SLD69600 SLD69300G SLD69400G SLD69500G SLD69600G SLD69300NT SLD69400NT SLD69500NT SLD69600NT SLD69300NGT SLD69400NGT SLD69500NGT SLD69600NGT Max List Current Price Rating $ 300 400 500 600 300 400 500 600 300 400 500 600 300 400 500 600
Type SHLD6-A
Black Label
3-Pole, 600V AC Catalog Number SHLD69300 SHLD69400 SHLD69500 SHLD69600 SHLD69300G SHLD69400G SHLD69500G SHLD69600G SHLD69300NT SHLD69400NT SHLD69500NT SHLD69600NT SHLD69300NGT SHLD69400NGT SHLD69500NGT SHLD69600NGT Max List Current Price Rating $ 300 400 500 600 300 400 500 600 300 400 500 600 300 400 500 600
Type SCLD6-A
Red Label
3-Pole, 600V AC Catalog Number SCLD69300 SCLD69400 SCLD69500 SCLD69600 SCLD69300G SCLD69400G SCLD69500G SCLD69600G SCLD69300NT SCLD69400NT SCLD69500NT SCLD69600NT SCLD69300NGT SCLD69400NGT SCLD69500NGT SCLD69600NGT Max List Current Price Rating $ 300 400 500 600 300 400 500 600 300 400 500 600 300 400 500 600
Shipping Weights
Breaker Type SLD6-A SHLD6-A SCLD6-A Number per Carton 1 1 1 Shipping Weight (lbs) 20 20 33
Neutral Transformers
Ampere Rating 300 400 500 600 Catalog Number N03SJD N04SJD N05SLD N06SLD List Price $
Interrupting Ratings
Breaker Type SLD6-A SHLD6-A SCLD6-A RMS Symmetrical kA UL 489 (File E10848) 240V AC 065 100 200 480V AC 035 065 150 600V AC 025 035 100
Note: G suffix in catalog number denotes circuit breaker for 3-phase, 3-wire circuits. For 3-phase, 4-wire, order correct 4th wire (neutral) transformer as separate and additional item.
For ordering information and terminal connectors see page 17/72; for enclosures, see page 17/73. 100% Rated Not available in SLD6 Frame.
17/74
Type LMXD6
Continuous Current Rating @ 40C 500 600 700 800 2-Pole (3-Pole Width) Catalog List Number Price $ LMXD62B600 LMXD62B700 LMXD62B800
Blue Label
3-Pole Catalog Number LMXD63B500 LMXD63B600 LMXD63B700 LMXD63B800
Ordering Information
Complete Breaker Unassembled with Lugs Prices of LMD6 and HLMD6 breakers include frame, trip, and both line and load lugs (TA3K500). These catalog numbers include the frame, trip and lugs separately packaged. For applications requiring different lugs, order individual items as needed. Complete Breaker Assembled without Lugs Prices of LMXD6 and HLMXD6 include frame with non-interchangeable trip unit installed only. Order required lugs separately. For line and load lugs (TA3K500) installed, add suffix L to catalog number (add 2 times list price of lugs for each pole). 50C Applications see page 17/110. 400Hz Applications see page 17/110.
Type LMD6
Interchangeable Trip
Continuous Current Rating @ 40C 500 600 700 800 Complete Breaker Unassembled w/Lugs Catalog List Number Price $ LMD62B500 LMD62B600 LMD62B700 LMD62B800 Frame Only Catalog Number List Price $
Blue Label
List Price $
Shipping Weights
Number of Poles Number per Carton Shipping Weight (lbs.) LMD6, HLMD6, LMXD6, HLMXD6 Complete Breaker (less terminals) 2 3 2 3 2 3 1 1 1 1 1 1 53 61.5 42.25 46 4.5 6.5
Built to order. Allow 23 weeks for delivery. LMXD6 circuit breakers are UL Listed for reverse connected applications. When wired as shown on page 17/5, this circuit breaker is UL listed and rated for use on 500VDC ungrounded UPS systems only.
17/75
Type HLMXD6
2-Pole Continuous Current Rating @ 40C 500 600 700 800 600V AC/250V DC 3-Pole
Black Label
Type HLMD6
Interchangeable Trip
Continuous Current Rating @ 40C Complete Breaker Unassembled Catalog Number List Price $ Frame Only Catalog Number List Price $
Black Label
W
Trip Unit Only Catalog Number List Price $
D1 D
Interrupting Ratings
Breaker Type LMD6, LMXD6 HLMD6, HLMXD6 UL 489A IR RMS Symmetrical Amperes (KA) Volts AC Volts DC 240 65 100 480 50 065 600 25 050 250 30 (2-P) 30 (2-P) IEC 947-2 Volts AC (50/60HZ) 220/240 380/415
7.5
16
4.5
5.93
500 (lcu) (lcs) (lcu) (lcs) (lcu) (lcs) 25 (3-P) 065 033 040 20 30 15 50 (3-P) 100 050 065 33 42 21
Enclosures
Type 1 3R 12 Neutral Catalog Number LMD1 LMD3R LMD12 W63623 List Price $
For inches / millimeters conversion, see Application Data section. Built to order. Allow 23 weeks for delivery. HLMXD6 circuit breakers are UL Listed for reverse connection applications. LMXD6-ETI, see page 17/88 for catalog information. When wired as shown on page 17/5, this circuit breaker is UL listed and rated for use on 500VDC ungrounded UPS systems only. HACR rated.
17/76
Internal Accessories
Selection
Accessories for:
JD 400A Frame LD 600A Frame LMD 800A Frame SJD 400A Frame SLD 600A Frame
--
Sensitrip Ammeter
The Ammeter Display Units plug into the Sensitrip Trip Unit and displays the phrase current flowing in the SADU breaker. They are powered by the breakers CTs with replaceable battery back-up for maintaining trip and max logs. The SADU reads currents, current imbalance, current demand, and trip status.
Note: Accessory modules can only be added to right side pole of solid state SJD and SLD frame circuit breakers. No accessories can be added if mechanical interlock is used. All accessories on this page are useable on superseded JD2, JJ6, JL6, HJ6, SJL, LJ6, LL6, HL6 and SLL circuit breakers.
17/77
Type MXD6
Continuous Current Rating @ 40C 600 700 800 2-Pole Catalog Number MXD62B600 MXD62B700 MXD62B800 List Price $ 3-Pole Catalog Number MXD63B600 MXD63B700 MXD63B800
Blue Label
Ordering Information
Complete Breaker Unassembled with Lugs Pricing information for MD6 and HMD6 breakers includes frame, trip, and both line and load lugs (TA3K500). When ordered by these catalog numbers, the customer will receive the frame, trip and lugs separately packaged. For applications requiring different lugs, order individual items as needed. Complete Breaker Assembled without Lugs Prices of MXD6, HMXD6 and CMD6 include frame with non-interchangeable trip units installed only. Order required lugs separately. For line and load lugs (TA3K500) installed, add suffix L to catalog number (add 2 times list price of lugs for each pole). 100% Rated Types MXD6, HMXD6 and CMD6 breakers are available with 100% ratings. To order add suffix H to catalog number, and 10% to list price. 100% rated MD breakers require the use of 90C Cu cable sized at 75C ampacity and lugs 2TA4P8500 or 2TA2N8750 for 2-pole; 3TA4P8500 or 3TA2N8750 for 3-pole. 50C Applications see page 17/110. 400Hz Applications see page 17/110.
Type MD6
Interchangeable Trip
Continuous Current Setting @ 40C Complete Breaker Unassembled with Lugs Catalog Number List Price $ Frame Only Catalog Number List Price $
Blue Label
Lugs
Catalog Number TA2K500 TA3K500 TC2K500 TC3K350 Kits 2TA2N8750 3TA2N8750 2TA3N8750 3TA3N8750 2TA4N8500 3TA4N8500 2TA4P8500 3TA4P8500 1-2 1-3 1-4 1-4 2 3 2 3 2 3 2 3 500-750 kcmil Cu / Al 500-750 kcmil Cu / Al 250-500 kcmil Cu / Al 250-500 kcmil Cu/Al Cables Per Lug 1-2 1-3 1-2 1-3 Lugs Per Kit 1 1 1 1 Wire Range #1-500 kcmil Cu / Al 1/0-500 kcmil Cu / Al #1-500 kcmil Cu #1-350 kcmil Cu List Price $
Shipping Weights
Number of Number per Poles Carton MD6, HMD6, HMXD6, CMD6 Complete Breaker Assembled (less lugs) 2 1 3 1 7 5570 7420 High +/- 20% Tolerance 6000 8000 MD6, HMD6 Frame Only 2 3 2 3 1 1 1 1 42.25 46 4.5 6.5 Shipping Weight (lbs.)
53 61.5
Enclosures
Type 1 3R 12
Built to order. Allow 23 weeks for delivery. MXD6 circuit breakers are UL Listed for reverse connection applications. 2-pole units available in 3-pole width only. When wired as shown on page 17/5, this circuit breaker is UL listed and rated for use on 500V DC ungrounded UPS systems. See Note: A, page 17/100. 80% rated breakers with the CE mark will also be marked in the 100% rated version. HACR rated. Note: MD frame qualified to UL489 supplement B NAVAL. See page 17/110 for additional information.
List Price $
Neutral
17/78
Type HMXD6
2-Pole Continuous Current Rating @ 40C 600 700 800 600V AC/250V DC 3-Pole
Black Label
Type HMD6
Interchangeable Trip
Continuous Current Rating @ 40C Complete Breaker Unassembled with Lugs Catalog Number List Price $ Frame Only Catalog Number List Price $
Black Label
Type CMD6
Fuseless Current Limiting
2-Pole Continuous Current Rating @ 40C 600 700 800 600V AC/250V DC 3-Pole
Red Label
Interrupting Ratings
UL 489 AIRFile E10848 RMS Symmetrical Amperes (KA) Volts AC Volts DC 240 065 100 200 480 050 065 100 600 25 50 65 250 30 (2-P) 30 (2-P) IEC 947-2 AIR Volts AC (50/60HZ) 220/240 380/415 500 500 (lcu) (lcs) (lcu) (lcs) (lcu) (lcs 25 (3-P) 065 033 040 20 30 15 50 (3-P) 100 050 065 33 50 (3-P) 200 100 100 50 42 65 21 33
16
8.25
24
8.25
For inches / millimeters conversion, see Application Data section. Built to order. Allow 23 weeks for delivery. HMXD6 and CMD circuit breakers are UL listed for reverse connection applications. 2-pole units available in 3-pole width only. MXD6-ETI, CMD6-ETI see page 17/88 for catalog information. When wired as shown on page 17/5, this circuit breaker is UL listed and rated for use on 500V DC ungrounded UPS systems only. HACR rated.
17/79
SMD 800A Frame, Digital Solid State Sentron Sensitrip III Series
Selection
Current Limiting Ordering Information
Pricing information for all Digital Sentron Series MD frames is for complete breaker only. Price requires lugs or lug kits as separate items. Lugs are suitable for 75C wire or as noted. Connector wire ranges and cavities are established in conjunction with Table 6.1.4.2.1 of UL 489 standards. Choose actual connector for circuit breakers based on customer requirements. Recommended Terminal Connectors
Breaker Frame MD MD Ampere Rating 500600 700800 Connector or Connector Kit
TA2K500 TA3K500
Type SMD6
Blue Label
3-Pole, 600V AC Catalog Number
SMD69600A SMD69700A SMD69800A SMD69600AG SMD69700AG SMD69800AG SMD69600ANT SMD69700ANT SMD69800ANT
Type SHMD6
Black Label
3-Pole, 600V AC Max Current List Rating Price $
600 700 800 600 700 800 600 700 800
Type SCMD6
Red Label
3-Pole, 600V AC Catalog Number
SCMD69600A SCMD69700A SCMD69800A SCMD69600AG SCMD69700AG SCMD69800AG SCMD69600ANT SCMD69700ANT SCMD69800ANT
Catalog Number
SHMD69600A SHMD69700A SHMD69800A SHMD69600AG SHMD69700AG SHMD69800AG SHMD69600ANT SHMD69700ANT SHMD69800ANT
Types SMD6 and SHMD6 are acceptable for reverse connection applications.
Shipping Weights
Current Limiting
Type SHMD6-H
Black Label
3-Pole, 600V AC Max Current List Rating Price $
600 700 800 600 700 800
Type SCMD6-H
Red Label
3-Pole, 600V AC Catalog Number
SCMD69600AH SCMD69700AH SCMD69800AH SCMD69600AGH SCMD69700AGH SCMD69800AGH SCMD69600ANTH SCMD69700ANTH SCMD69800ANTH
Catalog Number
SHMD69600AH SHMD69700AH SHMD69800AH SHMD69600AGH SHMD69700AGH SHMD69800AGH
SHMD69600ANTH 600 SHMD69700ANTH 700 SHMD69800ANTH 800 SHMD69600ANGTH 600 SHMD69700ANGTH 700 SHMD69800ANGTH 800
Cables Catalog per Wire List Number Lug Range Price $ TA2K500 2 #1-500 kcmil Cu/Al TA3K500 3 #1-500 kcmil Cu/Al TC2K500 2 #1-500 kcmil Cu TC3K350 3 #1-350 kcmil Cu Kits (3 lugs/kit) 3TA4N8500 4 250500 kcmil Cu/Al 3TA4P8500 4 250500 kcmil Cu/Al 3TA2N8750 2 500750 kcmil Cu/Al 3TA3N8750 3 500750 kcmil Cu/Al Each kit contains the following: 3TA4P85003 connectors plus 1 NDTS end barrier 3TA3N87503 connectors plus 1 NDTS end barrier 3TA2N87503 connectors plus 1 NDTS end barrier
Neutral Transformers
Ampere Rating 0600 0700 0800 Catalog Number N06SMDA N07SMDA N08SMDA List Price $
Enclosures
Type RMS Symmetrical kA UL 489 (File E10848) 240V AC 065 100 200 480V AC 050 065 100 600V AC 25 50 65 1 3R 12 Neutral Catalog Number MND61 MND63 MND612 W63623 List Price $
Interrupting Ratings
Breaker Type SMD6 SHMD6 SCMD6
Note: G suffix in catalog number denotes circuit breaker for 3-phase, 3-wire circuits. For 3-phase, 4-wire, order correct 4th wire (neutral) transformer as separate and additional item. Built to order. Allow 23 weeks for delivery.
Use 2-3TA4P8500 for 3-pole. These kits are rated for 90C wire. 90C Cu only cable must be used, and sized per 75C ampacity. For additional information, see Note: A, page 17/100. SMD6, SHMD6 and SCMD6 circuit breakers are UL Listed for reverse connection applications.
17/80
Type NXD6
2-Pole 600V AC 250V DC Catalog Number NXD62B900 NXD62B100 NXD62B120 List Price $
Blue Label
3-Pole 600V AC 500V DC Catalog Number NXD63B900 NXD63B100 NXD63B120 List Price $
Type ND6
Interchangeable Trip
Continuous Current Rating @ 40C Complete Breaker Unassembled with Lugs Catalog Number List Price $ Frame Only Catalog Number List Price $
Blue Label
Interrupting Ratings
Breaker Type ND6, NXD6 HND6, HNXD6 CND6 RMS Symmetrical Amperes (KA) UL 489 A IR Volts AC Volts DC 240 65 100 200 480 50 65 100 600 25 50 65 250 30 (2-P) 30 (2-P) 500 25 (3-P) 50 (3-P) 50 (3-P) IEC 947-2 Volts AC (50/60HZ) 220/240 380/415 (lcu) (lcs) (lcu) (lcs) 65 33 40 20 100 50 65 33 200 100 100 50 500 (lcu) 30 42 65 (lcs) 15 21 33
Lugs
Catalog Cables Wire Number per Lug Range TA2K500 2 #1-500 kcmil Cu/Al TA3K500 3 #1-500 kcmil Cu/Al TC2K500 2 #1-500 kcmil Cu TC3K350 3 #1-350 kcmil Cu Kits (2 Kits required per breaker) 2TA4P8500 4 250-500 kcmil Cu/Al 3TA4P8500 2TA4N8500 4 250-500 kcmil Cu/Al 3TA4N8500 2TA2N8750 2 500-750 kcmil Cu/Al 3TA2N8750 2TA3N8750 3 500-750 kcmil Cu/Al 3TA3N8750 List Price $
2 4570 5715
3 5140 6430
4 5710 7145
5 6280 7860
6 6850 8575
7 7420 9290
Enclosures
Type 1 3R 12 Neutral Catalog Number MND61 MND63 MND612 W63623 List Price $
Built to order. Allow 23 weeks for delivery. NXD6 circuit breakers are UL listed for reverse connection applications. 2-pole units available in 3-pole width only. When wired as shown on page 17/5, this circuit breaker is UL listed and rated for use on 500VDC ungrounded UPS systems only. Use 2 3TA4P8500 kits for 3-pole, or 2 2TA4P8500 kits for 2-pole. Use for 100% rated breakers.
Use 2 3TA4N8500 for 3-pole or 2 2TA4N8500 for 2-pole. Rated for 75C cable. See Note: A, page 17/100. 80% rated breakers with the CE mark will also be marked in the 100% rated version. HACR rated. Note: ND frame qualified to UL489 supplement B NAVAL. See page 17/110 for additional information.
17/81
Type HNXD6
2-Pole Continuous Current Rating @ 40C 0900 1000 1200 600V AC/250V DC 3-Pole
Black Label
Type HND6
Interchangeable Trip
Continuous Current Rating @ 40C Complete Breaker Unassembled with Lugs Catalog Number List Price $ Frame Only Catalog Number List Price $
Black Label
Type CND6
Fuseless Current Limiting Non-Interchangeable Trip (Assembled Circuit Breaker)
Continuous Current Rating @ 40C 0900 1000 1200 2-Pole 3-Pole
Red Label
Lugs
List Price $ When lugs shield NDTS is used.
Note: NDTS lug shields are required when oversized lugs TA4P8500 or TA4N8500 are used. The kits include the NDTS shield.
Catalog Number For 2-pole application, use outside poles of 3-pole circuit breaker CND63B900 CND63B100 CND63B120
Shipping Weights
Number of Number per Shipping Poles Carton Weight (lbs.) ND6, HND6, NXD6, HNXD6, CND6 Assembled Breaker (less terminals) 2 1 53 3 1 61.5 ND6, HND6 Frame Only 2 1 42.25 3 1 46 ND6, HND6 Trip Unit Only 2 1 04.5 3 1 06.5
24
8.25
For inches / millimeters conversion, see Application Data section. Built to order. Allow 23 weeks for delivery. HNXD6 and CND6 circuit breakers are UL Listed for reverse connection applications. 2-pole units available in 3-pole width only. When wired as shown on page 17/5, this circuit breaker is UL listed and rated for use on 500V DC ungrounded UPS systems only. HACR rated.
17/82
SND 1200A Frame, Digital Solid State Sentron Sensitrip III Series
Selection
Current Limiting
Type SND6
Blue Label
3-Pole, 600V AC Catalog Number
SND69800A SND69100A SND69120A SND69800AG SND69100AG SND69120AG SND69800ANT SND69100ANT SND69120ANT
Type SHND6
Black Label
3-Pole, 600V AC Max List Current Price Rating $
800 1000 1200 800 1000 1200 800 1000 1200
Type SCND6
Red Label
3-Pole, 600V AC Catalog Number
SCND69800A SCND69100A SCND69120A SCND69800AG SCND69100AG SCND69120AG
Catalog Number
SHND69800A SHND69100A SHND69120A SHND69800AG SHND69100AG SHND69120AG SHND69800ANT SHND69100ANT SHND69120ANT
SCND69800ANT 800 SCND69100ANT 1000 SCND69120ANT 1200 SCND69800ANGT 800 SCND69100ANGT 1000 SCND69120ANGT 1200
Current Limiting
Type SHND6H
Black Label
3-Pole, 600V AC Max List Current Price Rating $
800 1000 1200 800 1000 1200 800 1000 1200
Type SCND6-H
Red Label
3-Pole, 600V AC Catalog Number
SCND69800AH SCND69100AH SCND69120AH SCND69800AGH SCND69100AGH SCND69120AGH SCND69800ANTH SCND69100ANTH SCND69120ANTH
Catalog Number
SHND69800AH SHND69100AH SHND69120AH SHND69800AGH SHND69100AGH SHND69120AGH SHND69800ANTH SHND69100ANTH SHND69120ANTH
Interrupting Ratings
Breaker Type SND6 SHND6 SCND6 RMS Symmetrical kA UL 489 (File E10848) 240V AC 065 100 200 480V AC 050 065 100 600V AC 25 50 65
Neutral Transformers
Ampere Rating 0800 1000 1200 Catalog Number N08SMDA N10SNDA N12SNDA List Price $
For inches / millimeters conversion, see Application Data section. For ordering information and terminal connectors, and enclosures, see page 17/81. Note: G suffix in catalog number denotes circuit breaker for 3-phase, 3-wire circuits. For 3-phase, 4-wire, order correct 4th wire (neutral) transformer as separate and additional item. Built to order. Allow 23 weeks for delivery. Use 2-3TA4P8500 for 3-pole. These kits are rated for 90C wire. 90C Cu only cable must be used, and sized per 75C ampacity. SND6, SHND6 and SCND6 circuit breakers are UL Listed for reverse connection applications.
17/83
Blue Label
Lugs (6 required) Catalog Number TA5P600 List Price $
Ordering Instructions
Complete Breaker Unassembled with Lugs Prices of PD6, HPD6, RD6, and HRD6 type breakers include frame, trip, mounting base (MB9301), and both line and load lugs (PD Frame TA5P600, RD Frame TC5R600). When ordered by these catalog numbers, the customer will receive the frame, trip, mounting assembly and lugs separately packaged. For applications requiring different mounting base or lugs, order individual items as needed. Complete Breaker Assembled without Lugs Prices of PXD6, HPXD6, RXD6, HRXD6 and CPD6 type breakers include frame with non-interchangeable trip unit installed only. Order required mounting base and lugs separately. 100% Rated (3-Pole only) Types PXD6, HPXD6 breakers are available with 100% ratings. To order add suffix H to catalog number, and 10% to list price. 100% PD breakers require 90 C cable sized at 75 C ampacity and TC5R600 lugs. RD 2000A Frames not available with 100% ratings. 50C Applications see page 17/110. 400HZ Applications see page 17/110.
Blue Label
Lugs (6 required) List Catalog Price $ Number TA5P600 List Price $
Type HPXD6
Non-Interchangeable Trip
Blue Label
Complete Breaker Assembled (Frame/ Trip Unit Only) Catalog Number List Price $ HPXD63B120 HPXD63B140 HPXD63B160
Black Label
Lugs (6 required) List Catalog Price $ Number TA5P600 List Price $
Red Label
Complete Breaker Assembled (Frame/ Trip Unit Only) Catalog Number List Price $ CPD63B120 CPD63B140 CPD63B160
Lugs
Catalog Number TA5P600 TC5R600 TA4P750 TA6R600 No of Cables per Connector 1-5 Pcs. 1-5 Pcs. 1-4 Pcs. 1-6 Pcs. List Wire Range Price $ 300-600 kcmil Cu/Al 300-600 kcmil Cu only 500-750 kcmil Cu/Al 300-600 kcmil Cu/Al
Interrupting Ratings
UL 489 A IR RMS Symmetrical KA Breaker Type PD6, PXD6 HPD6, HPXD6 CPD6 Volts AC 240 65 100 200 480 50 65 100 600 25 50 65 Volts DC 250 30 (2P) 30 (2P) 30 (2P) 500 25 (3P) 50 (3P) 50 (3P) IEC 947-2 Volts AC (50/60HZ) 220/240 65 100 200 33 50 100 380/415 40 65 100 10 17 25 500 30 42 65 8 11 17 (lcu) (lcs) (lcu) (lcs) (lcu) (lcs)
Built to order. Allow 23 weeks for delivery. Built to order. Allow 68 weeks for delivery. Use two outside poles of a 3-pole circuit breaker for 250V When wired as shown on page 17/5, this circuit breaker is
UL listed and rated for use on 500V DC ungrounded UPS systems only. PXD6, HPXD6 and CPD6 type circuit breakers are UL Listed for reverse feed applications. For additional information See Note: A, page 17/100.
HACR rated. Note: PD frame qualified to UL489 supplement B NAVAL. See page 17/110 for additional information.
17/84
SPD 1600A Frame, Digital Solid State Sentron Sensitrip III Series
Selection/Dimensions Ordering Information
Pricing information for all Digital Sentron Series PD frame unit is for breaker only. Price required mounting block assembly and necessary terminal connectors as separate items. SPD6 and SHPD6 are acceptable for reverse connection applications.
Type SPD6
Blue Label
3-Pole, 600V AC Catalog Number
SPD69140 SPD69160 SPD69140G SPD69160G SPD69140NT SPD69160NT SPD69140NGT SPD69160NGT
Type SHPD6
Black Label
3-Pole, 600V AC Max Current Rating
1400 1600 1400 1600 1400 1600 1400 1600
List Price $
Catalog Number
SHPD69140 SHPD69160 SHPD69140G SHPD69160G SHPD69140NT SHPD69160NT SHPD69140NGT SHPD69160NGT
List Price $
Lugs
No. of Catalog Cables per Wire Number Connector Range
TA5P600 15 pcs. TC5R600 15 pcs. TA6R600 15 pcs. 300600 kcmil Cu/Al 300600 kcmil Cu Only 300600 kcmil Cu/Al
List Price $
Instantaneous Setting
Neutral Transformers
Ground Fault Pick Up Ground Fault Delay Ampere Rating 1400 1600 Catalog Number N14SPD N16SPD List Price $
Enclosure
Type 1 Catalog Number PRD6N1 List Price $
Interrupting Ratings
Breaker Type SPD6 SHPD6 RMS Symmetrical kA UL 489 240V AC 065 100 480V AC 050 065 600V AC 025 050
16.00
16.00
MBR9302
18.73
MB9301
25.50
MBR9302
MB9301
For inches / millimeters conversion, see Application Data section. Built to order. Allow 23 weeks for delivery. For additional information, see Note: A, page 17/100. Note: The PD frame circuit breaker requires the use of a connect-all mounting assembly to allow for placing into service. Note: G suffix in catalog number denotes circuit breaker for 3-phase, 3-wire circuits. For 3-phase, 4-wire, order correct 4th wire (neutral) transformer as separate and additional item.
17/85
Type RXD6
3-Pole 600V AC, 250-500V DC
Complete Breaker Assembled (Frame/Trip Unit Only) Catalog Number RXD63B160 RXD63B180 RXD63B200 List Price $ Mounting Assembly Catalog Number MB9301 -orMBR9302 List Price $
Blue Label
Type RD6
Interchangeable Trip (Unassembled Circuit Breaker with Lugs) 3-Pole 600V AC, 250-500V DC
Complete Breaker Unassembled with Lugs Catalog Number RD63B160 RD63B180 RD63B200 List Price $ Mounting Assembly Catalog Number MB9301 -orMBR9302
Blue Label
Mounting Block
Trip Unit Only List Price $ Catalog Number RD63T160 RD63T180 RD63T200 List Price $ Lugs (6 required) List Catalog List Price $ Number Price $ TC5R600
List Price $
Shipping Weights
Number of Number per Poles Carton PXD6, HPXD6, RXD6, HRXD6, Assembled Breakers 3 1 PD6, HPD6, RD6, HRD6 Frame Only 3 1 PD6, RD6 Trip Unit Only 3 1 Mounting Assembly MB9301 1 MBR9302 1 Shipping Weight (lbs.) CPD6 61.5
Type HRXD6
Continuous Current Rating 40C 1600 1800 2000 Catalog Number HRXD63B160 HRXD63B180 HRXD63B200
Black Label
Complete Breaker Assembled (Frame/ Trip Unit Only) List Price $
55.0
Type HRD6
Complete Breaker Unassembled Continuous with Lugs Current Catalog List Rating 40C Number Price $ 1600 1800 2000 HRD63B160 HRD63B180 HRD63B200 Frame Only Catalog Number HRD63F200 List Price $ Trip Unit Only Catalog Number RD63T160 RD63T180 RD63T200 Mounting Assembly
Black Label
Lugs (6 required) List Catalog List Price $ Number Price $ TC5R600
Lugs
Catalog Number TA5P600 TC5R600 TA6R600 No of Cables per Connector Wire Range 1-5 Pcs. 1-5 Pcs. 1-6 Pcs. 300-600 kcmil Cu/Al 300-600 kcmil Cu only 300-600 kcmil Cu/Al List Price $
Interrupting Ratings
UL 489 A IR RMS Symmetrical KA Breaker Type RD6, RXD6 HRD6, HRXD6 Volts AC 240 65 100 480 50 65 600 25 50 Volts DC 250 30 (2P) 30 (2P) 500 25 (3P) 50 (3P) IEC 947-2 Volts AC (50/60HZ) 220/240 65 100 33 50 380/415 40 65 10 17 500 30 42 8 11 (lcu) (lcs) (lcu) (lcs) (lcu) (lcs)
5 7860
6 8575
7 9790
Built to order. Allow 23 weeks for delivery. Built to order. Allow 68 weeks for delivery. Use two outside poles of a 3-pole circuit breaker for 250V DC applications.
When wired as shown on page 17/5, this circuit breaker is UL listed and rated for use on 500V DC ungrounded UPS systems only. RXD6 and HRXD6 type circuit breakers are UL Listed for reverse feed applications.
17/86
Internal Accessories
Selection
Accessories for:
MD/SMD 800A Frame ND/SND 1200A Frame PD/SPD 1600A Frame RD 2000A Frame
Accessory modules can mount in either left hand or right hand poles of all circuit breakers, including solid state. Exception: when mechanical interlock is used. Accessories cannot be mounted in left pole.
Sensitrip Ammeter
The Ammeter Display Units plug into the Sensitrip Trip Unit and displays the phase current flowing in the breaker. They are powered by the breakers CTs with replaceable battery back-up for maintaining trip and max logs. The SADU reads currents, current imbalance, current demand, and trip status.
17/87
ED6-A
600V AC 250V DC
Minimum 002.6 007 010 016 030 055 080 115 180 315 500 002.6 007 010 016 030 055 080 115 180 315 500 0400 0800 1100 1100 0400 0800 1100 1100 1250 2000 1250 2000 2000 3000 2000 3000 2800 3200 3000 4000 5000 3000 4000 5000
Maximum 00009 00022 00035 00054 00100 00180 00270 00375 00600 01000 01250 00009 00022 00035 00054 00100 00180 00270 00375 00600 01000 01250 00800 01500 02500 02500 00800 01500 02500 02500 02500 04000 02500 04000 04000 06000 04000 06000 06000 08000 06000 08000 10000 06000 08000 10000
CED6-A
600V AC 250V DC
FXD6
600V AC 250V DC
CFD6
600V AC 250V DC
JXD6(A)
600V AC 250V DC 600V AC 250V DC 600V AC 250V DC 600V AC 250V DC 600V AC 250V DC
Complete Circuit Breaker Without Lugs Catalog Catalog Number List Number 2-Pole Price $ 3-Pole ED63A001 ED63A002 ED63A003 ED63A005 ED63A010 ED63A025 ED63A030 ED63A040 ED63A050 ED63A100 ED63A125 03.8 lbs. each CED63A001 CED63A001 CED63A003 CED63A005 CED63A010 CED63A025 CED63A030 CED63A040 CED63A050 CED63A100 CED63A125 06 lbs. each FXD63L150 FXD63A150 FXD63H150 FXD63A250 0 09 lbs. each CFD63L150 CFD63A150 CFD63H150 CFD63A250 12 lbs. each 12 lbs. each JXD63L400 JXD62H400 JXD63H400 16 lbs. each 20 lbs. each CJD62L400 CJD63L400 CJD62H400 CJD63H400 29.5 lbs. each 31.5 lbs. each LXD62L600 LXD63L600 LXD63H600 16 lbs. each 20 lbs. each CLD62L600 CLD63L600 CLD62H600 CLD63H600 31.5 lbs. each LMXD63L800 LMXD63A800 35 lbs. each MXD63L800 MXD63A800 MXD63H800 33 lbs. each CMD63L800 CMD63A800 CMD63H800 80 lbs. each
List Price $
CMD6
600V AC 250V DC
Important Information ETI interrupting ratings are determined through combination tests with properly sized overload relays and contactors. Connectors included when ordering by circuit breaker catalog number for ED6 and CED6 ETIs. Order ETI circuit breaker and lugs (2 per pole) separately for the FXD6, CFD6, MXD6, CMD6, JXD6, CJD6, LXD6 and CLD6 ETIs.
Lug Information pages 17/100 to 17/102 Accessories pages 17/103 to 17/108 Application data pages 17/89 to 17/90
Built to order. Allow 23 weeks for delivery. 2-pole available in 3-pole width only.
When applied on DC Circuits Trip levels will increase approximately +15 to 20%. Tolerance -20/+30%
17/88
Motor Circuits
Application
General
Protection of Motor Circuits Molded case circuit breakers are used in motor circuits as a disconnecting means and for short-circuit protection. They should be used in conjunction with motor-running, over-current-protection devices, and should permit the motor to start without nuisance tripping from motor-inrush current. The circuit breaker should have a continuous-current rating of not less than 115% of the motor full-load current. The recommended motor circuit protectors (Siemens ETI instantaneous only circuit breakers) listed have
continuous-current ratings of at least 115% of motor full-load currents. The trip-setting positions are approximately 11 times motor full-load currents. The suggested trip settings may have to be adjusted upward to no higher than 1300% of full-load current for non-design E type motors, and no greater than 1700% of full load current for design E motors, to allow for motor start-up due to inrush currents. Breaker Mounted Immediately Ahead of Motor Starter Siemens ETI motor circuit protectors are recommended for use in combination motor starters to provide selective short-circuit protection for the motor
branch circuit. The adjustable instantaneous-trip feature of the Siemens ETI motor circuit protector provides for a trip setting slightly above the peak motor-inrush current. With this setting, no delay is introduced in opening the circuit when a fault occurs. This circuit breaker has no time-delay trip element. Therefore it must be used in conjunction with, and immediately ahead of, the motor-running overcurrent protective device. Important: The information below does not apply to all motor applications: it is recommended that the user refer to the National Electrical Code (NEC) for specific needs.
Catalog Number
ED63A001 CED63A001
ED63A002 CED63A002
ED63A003 CED63A003
ED63A005 CED63A005
ED63A010 CED63A010
ED63A025 CED63A025
ED63A030 CED63A030
ED63A040 CED63A040
Motor Full Load Amperes 38.46 55.37 55.38 70.75 70.76 84.60 84.61 96.14 96.15 113.60 30.76 35.37 35.38 39.99 44.51 49.23 53.84 58.45 58.46 63.06 63.07 74.50 61.53 69.22 69.23 76.91 84.61 92.29 100.00 108.00 108.00 115.00 115.00 136.00 85.00 100.00 100.00 115.00 131.00 146.00 162.00 177.00 177.00 192.00 192.00 227.00 95.00 110.00 110.00 124.00 138.00 151.00 165.00 178.00 178.00 192.00 192.00 227.00 154.00 176.00 176.00 198.00 220.00 242.00 264.00 285.00 285.00 308.00 308.00 326.00 155.00 176.00 176.00 198.00 220.00 242.00 264.00 285.00 285.00 308.00 308.00 326.00
Catalog Number
ED63A125 CED63A125
LXD63H600 CLD63H600
FXD63L150 CFD63L150
LMXD63L800
FXD63A150 CFD63A150
LMXD63A800
FXD63A250 CFD63A250
MXD63L800 CMD63L800
JXD63L400 CJD63L400
MXD63A800 CMD63A800
JXD63H400 CJD63H400
MXD63H800 CMD63H800
LXD63L600 CLD63L600
ED63A050 CED63A050
ED63A100 CED63A100
Note: Low instantaneous settings have a +20% tolerance and high settings have a +20% tolerance
17/89
Motor Circuits
Application
Breaker Mounted at a Distance From Motor Starter ET thermal-magnetic circuit breakers conform to the National Electrical Code table 430-152 requirements for motor branch and feeder circuit protection when properly applied in conjunction with motor-running overcurrent protective devices. The recommended
circuit-breaker ratings in Table 2 provide adequate time delay for starting the majority of three phase induction motors. To determine the ampere ratings of the ET breaker to protect a motor feeder, add the rating of the ET breaker used to protect the largest motor branch circuit in the group to the full-load currents of the remaining motors in the group.
Interrupt Ratings For normal commercial purposes, available fault current can conveniently be obtained in the Interrupting Selector Tables.
Motor Horsepower Rating 00012 00034 001 00112 002 003 005 00712 010 015 020 025 030 040 050 060 075 100 125 150 200 250 300 350 400 500
200 and 208V Motors 240V Circuit Breaker Data Breaker Catalog Type Number BQ3B015 BQ3B015 BQ3B015 BQ BQ3B015 BQ3B020 BQ3B030 BQ3B040 BQ3B060 BQ BQ3B070 BQ3B100 FXD63B125 FXD63B150 FXD63B175 FXD63B200 FXD63B225 JXD23B300 JXD23B400 JXD23B400 LD63B600 LMD63B600 LD63B600 or LMD63B600 LMD63B800
FXD6
230V Motors 240V Circuit Breaker Data Ampere Breaker Catalog Ampere Rating Type Number Rating 015 BQ3B015 015 015 BQ3B015 015 015 BQ3B015 015 BQ 015 BQ3B015 015 020 BQ3B015 015 030 BQ3B020 020 040 BQ3B030 030 060 BQ3B050 050 070 BQ BQ3B070 070 100 BQ3B090 090 BQ3B100 100 125 FXD63B125 125 150 FXD63B150 150 175 FXD6 FXD63B175 175 200 FXD63B200 200 225 300 400 JXD2 JXD23B350 350 400 600 600 800 JXD2 LD6 or LMD6 LMD6 LMD6 JXD23B400 LD63B500 or LMD63B500 LD63B600 or LMD63B600 LMD63B800 400 500 600 800
460V Motors 480V Circuit Breaker Data Breaker Catalog Type Number ED43B015 ED43B015 ED43B015 ED4 ED43B015 ED43B015 ED43B015 ED43B015 ED43B030 ED4 ED43B030 ED43B040 ED43B050 FXD63B090 FXD63B100 FXD6 FXD63B125 FXD63B150 FXD6, FD6 FXD6, FD6 FD6 JD6 JD6 JD6 JD6 JD6 LD6 or LMD6 LMD6 LMD6 FXD63B150 FXD63B200 FD63B250 JD63B250 JD63B300 JD63B300 JD63B350 JD63B400 LD63B600 or LMD63B600 LMD63B700 LMD63B800
Ampere Rating 015 015 015 015 015 015 015 030 030 040 050 090 100 125 150 150 200 250 250 300 300 350 400 600 700 800
575V Motors 600V Circuit Breaker Data Breaker Catalog Ampere Type Number Rating ED63B015 015 ED63B015 015 ED63B015 015 ED6 ED63B015 015 ED63B015 015 ED63B015 015 ED63B015 015 ED63B020 020 ED6 ED63B030 030 ED63B035 035 ED63B050 050 FXD63B060 060 FXD63B070 070 FXD6 FXD63B090 090 FDX63B100 100 FXD6 FXD63B100 FXD6, FD6 FXD63B125 FXD6, FD6 FD63B175 FXD6, FD6 OR JD6 FXD6 or JD6 JD6 JD6 JD6 LD6 or LMD6 LD6 or LMD6 LMD6 FXD63B200 JD63B200 FXD63B225 JD63B225 JD63B300 JD63B400 JD63B400 LD63B500 or LMD63B500 LD63B600 or LMD63B600 LMD63B800 100 125 175 200 200 225 225 300 400 400 500 600 800
The selection of breakers for this table is in accordance with Article 430, 2005 National Electric Code. Recommended circuit breakers are for full voltage starting, special consideration is necessary for reduced voltage starting.
For panelboard applications, substitute the BL breaker for the BQ, ED2 circuit breakers may also be used.
For non-interchangeable trip applications, substitute the FXD6 for the FD6, the JXD6 for the JD6, or the LXD6 for the LD6.
17/90
Breaker Type
ED6
CED6
FXD6-A
FD6-A
HFD6
HHFD6
CFD6
Maximum Continuous Amperes 1 2 3 5 10 25 30 40 50 100 125 1 2 3 5 10 25 30 40 50 100 125 70 80 90 100 110 125 150 150 150 175 200 225 250 70 80 90 100 110 125 150 175 200 225 250 70 80 90 100 110 125 150 175 200 225 250 70 80 90 100 110 125 150 175 200 225 250 70 80 90 100 110 125 150 150 150 175 200 225 250
Nominal AC Adjustable Low 2 2.6 4.5 7 11 10 17 16 26 30 50 55 90 80 135 115 185 180 300 315 540 500 720 2.6 4.5 7 11 10 17 16 26 30 50 55 90 80 135 115 185 180 300 315 540 500 720 600 640 600 640 600 640 700 770 700 770 800 900 400 460 800 900 1100 1300 900 1060 900 1060 1100 1300 1100 1300 600 640 600 640 600 640 700 770 700 770 800 900 800 900 900 1060 900 1060 1100 1300 1100 1300 600 640 600 640 600 640 700 770 700 770 800 900 800 900 900 1060 900 1060 1100 1300 1100 1300 600 640 600 640 600 640 700 770 700 770 800 900 800 900 900 1060 900 1060 1100 1300 1100 1300 600 640 600 640 600 640 700 770 700 770 800 900 400 460 800 900 1100 1300 900 1060 900 1060 1100 1300 1100 1300
Trip Range 3 4 6 7.5 15 19 23 30 36 46 70 85 125 155 185 235 255 325 410 520 740 890 920 1100 6 7.5 15 19 23 30 36 46 70 85 125 155 185 235 255 325 410 520 740 890 920 1100 690 730 690 730 690 730 840 920 840 920 1000 1100 520 580 1000 1100 1500 1700 1210 1370 1210 1370 1500 1700 1500 1700 690 730 690 730 690 730 840 920 840 920 1000 1100 1000 1100 1210 1370 1210 1370 1500 1700 1500 1700 690 730 690 730 690 730 840 920 840 920 1000 1100 1000 1100 1210 1370 1210 1370 1500 1700 1500 1700 690 730 690 730 690 730 840 920 840 920 1000 1100 1000 1100 1210 1370 1210 1370 1500 1700 1500 1700 690 730 690 730 690 730 840 920 840 920 1000 1100 520 580 1000 1100 1500 1700 1210 1370 1210 1370 1500 1700 1500 1700
5 770 770 770 990 990 1200 640 1200 1900 1520 1520 1900 1900 770 770 770 990 990 1200 1200 1520 1520 1900 1900 770 770 770 990 990 1200 1200 1520 1520 1900 1900 770 770 770 990 990 1200 1200 1520 1520 1900 1900 770 770 770 990 990 1200 640 1200 1900 1520 1520 1900 1900
6 810 810 810 1060 1060 1300 700 1300 2100 1780 1780 2100 2100 810 810 810 1060 1060 1300 1300 1780 1780 2100 2100 810 810 810 1060 1060 1300 1300 1780 1780 2100 2100 810 810 810 1060 1060 1300 1300 1780 1780 2100 2100 810 810 810 1060 1060 1300 700 1300 2100 1780 1780 2100 2100
7 850 850 850 1140 1140 1400 760 1400 2300 1930 1930 2300 2300 850 850 850 1140 1140 1400 1400 1930 1930 2300 2300 850 850 850 1140 1140 1400 1400 1930 1930 2300 2300 850 850 850 1140 1140 1400 1400 1930 1930 2300 2300 850 850 850 1140 1140 1400 760 1400 2300 1930 1930 2300 2300
High 9 22 35 54 100 180 270 375 600 1000 1250 9 22 35 54 100 180 270 375 600 1000 1250 900 900 900 1200 1200 1500 820 1500 2500 2000 2000 2500 2500 900 900 900 1200 1200 1500 1500 2000 2000 2500 2500 900 900 900 1200 1200 1500 1500 2000 2000 2500 2500 900 900 900 1200 1200 1500 1500 2000 2000 2500 2500 900 900 900 1200 1200 1500 820 1500 2500 2000 2000 2500 2500
Note: Tolerances for instantaneous trip points meet UL 489 (7.3). Nominal AC instantaneous trip points are given in the tables. For DC instantaneous trip points, add 15% to nominal values.
Instantaneous trip adjustment is made through the breaker cover on all frame breakers. To change instantaneous trip point on circuit breaker, depress indicating knob, then rotate to desired position.
17/91
JXD2(A)
JXD6(A)
JD6(A)
HJD6(A)
HHJD6
CJD6
LXD6(A)
LD6(A)
HLD6(A)
HHLD6
CLD6
LMXD6
LMD6
5 1960 1960 1960 1960 3140 3140 1960 1960 1960 1960 3140 3140 1960 1960 1960 1960 3140 1960 3140 1960 1960 1960 1960 3140 3140 1960 1960 1960 1960 3140 3140 1960 1960 1960 1960 3140 3140 1960 3140 4710 4710 1960 1960 3140 3140 3140 4710 3140 4710 1960 1960 3140 3140 3140 4710 4710 1960 1960 3140 3140 3140 4710 4710 1960 1960 3140 3140 3140 4710 3140 4710 4710 4710 4700 4000 4700 4710 4710 4700 4700
6 2140 2140 2140 2140 3430 3430 2140 2140 2140 2140 3430 3430 2140 2140 2140 2140 3430 2140 3430 2140 2140 2140 2140 3430 3430 2140 2140 2140 2140 3430 3430 2140 2140 2140 2140 3430 3430 2140 3430 5140 5140 2140 2140 3430 3430 3430 5140 3430 5140 2140 2140 3430 3430 3430 5140 5140 2140 2140 3430 3430 3430 5140 5140 2140 2140 3430 3430 3430 5140 3430 5140 5140 5140 6400 4800 6400 5140 5140 6400 6400
7 2320 2320 2320 2320 3710 3710 2320 2320 2320 2320 3710 3710 2320 2320 2320 2320 3710 2320 3710 2320 2320 2320 2320 3710 3710 2320 2320 2320 2320 3710 3710 2320 2320 2320 2320 3710 3710 2320 3710 5570 5570 2320 2320 3710 3710 3710 5570 3710 5570 2320 2320 3710 3710 3710 5570 5570 2320 2320 3710 3710 3710 5570 5570 2320 2320 3710 3710 3710 5570 3710 5570 5570 5570 7300 5500 7300 5570 5570 7300 7300
High 2500 2500 2500 2500 4000 4000 2500 2500 2500 2500 4000 4000 2500 2500 2500 2500 4000 2500 4000 2500 2500 2500 2500 4000 4000 2500 2500 2500 2500 4000 4000 2500 2500 2500 2500 4000 4000 2500 4000 6000 6000 2500 2500 4000 4000 4000 6000 4000 6000 2500 2500 4000 4000 4000 6000 6000 2500 2500 4000 4000 4000 6000 6000 2500 2500 4000 4000 4000 6000 4000 6000 6000 6000 8000 6000 8000 6000 6000 8000 8000
ETI Motor Circuit Protector Catalog Number 3-Pole JXD63L400 JXD63H400 CJD63H400 CJD63L400 LXD63L600 LXD63H600 CLD63L600 CLD63H600 LMXD63L800 LMXD63A800
Thermal Magnetic Catalog Number 2-Pole 3-Pole JXD22B200 JXD23B200 JXD22B225 JXD23B225 JXD22B250 JXD23B250 JXD22B300 JXD23B300 JXD22B350 JXD23B350 JXD22B400 JXD23B400 JXD62B200 JXD63B200 JXD62B225 JXD63B225 JXD62B250 JXD63B250 JXD62B300 JXD62B300 JXD62B350 JXD23B350 JXD62B400 JXD23B400 JD62B200 JD63B200 JD62B225 JD63B225 JD62B250 JD63B250 JD62B300 JD63B300 JD62B350 JD63B350 JD62B400 JD63B400 HJD62B200 HJD63B200 HJD62B225 HJD63B225 HJD62B250 HJD63H250 HJD62B300 HJD63B300 HJD62B350 HJD63B350 HJD62H400 HJD63B400 HHJD62B200 HHJD63B200 HHJD62B225 HHJD63B225 HHJD62B250 HHJD63B250 HHJD62B300 HHJD63B300 HHJD62B350 HHJD63B350 HHJD62B400 HHJD63B400 CJD63B200 CJD63B225 CJD63B250 CJD63B300 CJD63B350 CHD63B400 LXD62B450 LXD63B450 LXD62B500 LXD63B500 LXD62B600 LXD63B600 LD62B250 LD63B250 LD62B300 LD63B300 LD62B350 LD63B350 LD62B400 LD63B400 LD62B450 LD63B450 LD62B500 LD63B500 LD62B600 LD63B600 HLD62B250 HLD63B250 HLD62B300 HLD63B300 HLD62B350 HLD63B350 HLD62B400 HLD63B400 HLD62B450 HLD63B450 HLD62B500 HLD63B500 HLD62B600 HLD63B600 HHLD62B250 HHLD63B250 HHLD62B300 HHLD63B300 HHLD62B350 HHLD63B350 HHLD62B400 HHLD63B400 HHLD62B450 HHLD63B450 HHLD62B500 HHLD63B500 HHLD62B600 HHLD63B600 CLD63B250 CLD63B300 CLD63B359 CLD63B400 CLD63B450 CLD63B500 CLD63B600 LMXD63B500 LMXD62B600 LMXD63B600 LMXD62B700 LMXD63B700 LMXD62B800 LMXD63B800 LMD62B500 LMD63B500 LMD62B600 LMD63B600 LMD62B700 LMD63B700 LMD62B800 LMD63B800 Siemens Industry, Inc. Industrial Controls Catalog
17/92
HLMD6
MD6
MXD6
HMD6
HMXD6
CMD6
ND6
NXD6
HND6
HNXD6
CND6
PD6
PXD6
HPD6
HPXD6
Maximum Continuous Amperes 500 600 700 800 500 600 700 800 500 600 700 800 800 800 500 600 700 800 800 800 500 600 700 800 500 600 700 800 400 500 600 700 800 800 800 800 900 1000 1200 900 1000 1200 800 900 1000 1200 900 1000 1200 800 900 1000 1200 1200 1400 1600 1200 1400 1600 1200 1400 1600 1200 1400 1600 1200 1400 1600 1800 2000 1800 2000 1800 2000 1800 2000
Nominal AC Adjustable Trip Range Low 2 3 4 3000 3430 3860 4290 3000 3430 3860 4290 3200 3500 3700 4200 3200 3500 3700 4200 3000 3430 3860 4290 3000 3430 3860 4290 3200 3500 3700 4200 3200 3500 3700 4200 3000 3430 3860 4290 3000 3430 3860 4290 4000 4570 5140 5710 3000 3430 3860 4280 4000 4570 5140 5710 5000 5715 6430 7145 3000 3430 3860 4280 3000 3430 3860 4280 4000 4570 5140 5710 3000 3430 3860 4280 4000 4570 5140 5710 5000 5715 6430 7145 3000 3430 3860 4280 3000 3430 3860 4280 4000 4570 5140 5710 4000 4570 5140 5710 3000 3430 3860 4280 3000 3430 3860 4280 4000 4570 5140 5710 4000 4570 5140 5710 3000 3430 3860 4280 3000 3430 3860 4280 3000 3430 3860 4280 4000 4570 5140 5710 3000 3430 3860 4280 4000 4570 5140 5710 5000 5715 6430 7145 4000 4570 5140 5710 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 4000 4570 5140 5710 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 4000 4570 5140 5710 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145
5 4710 4710 4700 4700 4710 4710 4700 4700 4710 4710 6280 4710 6280 7860 4710 4710 6280 4710 6280 7860 4710 4710 6280 6280 4710 4710 6280 6280 4710 4710 4710 6280 4710 6280 7860 6280 7860 7860 7860 7860 7860 7860 6280 7860 7860 7860 7860 7860 7860 6280 7860 7860 7860 7860 7860 7860 7860 7860 7860 7860 7860 7860 7860 7860 7860 7860 7860 7860 7860 7860 7860 7860 7860 7860 7860 7860
6 5140 5140 6400 6400 5140 5140 6400 6400 5140 5140 6850 5140 6850 8575 5140 5140 6850 5140 6850 8575 5140 5140 6850 6850 5140 5140 6850 6850 5140 5140 5140 6850 5140 6850 8575 6850 8575 8575 8575 8575 8575 8575 6850 8575 8575 8575 8575 8575 8575 6850 8575 8575 8575 8575 8575 8575 8575 8575 8575 8575 8575 8575 8575 8575 8575 8575 8575 8575 8575 8575 8575 8575 8575 8575 8575 8575
7 5570 5570 7300 7300 5570 5570 7300 7300 5570 5570 7420 5570 7420 9290 5570 5570 7420 5570 7420 9290 5570 5570 7420 7420 5570 5570 7420 7420 5570 5570 5570 7420 5570 7420 9290 7420 9290 9290 9290 9290 9290 9290 7420 9290 9290 9290 9290 9290 9290 7420 9290 9290 9290 9290 9290 9290 9290 9290 9290 9290 9290 9290 9290 9290 9290 9290 9290 9290 9290 9290 9290 9290 9290 9290 9290 9290
High 6000 6000 8000 8000 6000 6000 8000 8000 6000 6000 8000 6000 8000 10000 6000 6000 8000 6000 8000 10000 6000 6000 8000 8000 6000 6000 8000 8000 6000 6000 6000 8000 6000 8000 10000 8000 10000 10000 10000 10000 10000 10000 8000 10000 10000 10000 10000 10000 10000 8000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000
17/93
List Price $
Self-Protective Instantaneous Override 20% 11000 11000 11000 11000 11000 11000 11000 11000 11000 11250 11250 12000 13200 13200 13200 16000 16000 16000 16000 16000 16000 16000 18000 18000 18000 10000 10000 10000 10000
Ordering Information
Order by catalog number. Switches include frame and self protective (except TD) trip unit only. Order lugs separately from pages 17/100 to 17/102.
1225 1250
1600
1800
Withstand
50kA 50kA 50kA
Built to order. Allow 23 weeks for delivery. For 2-pole application use outside poles of 3-pole circuit breaker. For additional lugs see pages 17/100 to 17/102.
Molded case switches up to R frame contain a self protecting instantaneous element, which may open circuit above their override set point. UL file E57556 Volume 1, section 2 and CSA LR 42022-51. Requires mounting block MB9301 or MBR9302.
17/94
Internal Accessories
General
Feature Combinations
The available feature combinations are shown in the chart below. For applications requiring combinations of features not listed in this chart, consult the sales office for availability.
Modules Avail. On ST/ Per Breaker ST/ ST/ AUX/ UVT/ Breaker Poles ST AUX ALSW ALSW UVT AUX 1 1 1 1 2 2 1 1, 2, 3 2, 3 3 1, 2, 3 2, 3 2, 3 3 1 1 1/1 1 1/1 1 1 1 1 1 1/1/1 1 1 1 1 1/1, 1/2 1/1 1/1 1/1, 1/2 1/1, 1/2 1/1/1 UVT/ UVT/ ST/ ALSW ALSW Elect. Bell Ground Grd fault ALSW Alarm fault w/Bell 1 1 1 1, 2 1, 2 1 1
Breakers QP, BQ, BL BQD, CQD, NGG QJ All ED All FD All JD, LD, LMD SJD6, SHJD6, SCJD6, SLD6, SHLD6, SCLD6 All MD, ND, PD, RD Including Electronic trip
AUX/ ALSW 1/1 1/1, 2/1 1/1 1/1, 1/2 1/1, 1/2
1 1/1,1/2 1/1
2, 3
1 1/1
1/1, 1/2
1, 2 1 NC / 1 NO, 2 NC / 2 NO,
1/1, 2/1
1, 2
STD
voltage returns to 85% of line voltage. The undervoltage trip, which is continuously energized, must be energized before the circuit breaker can be closed.
For ED Frames
For FD Frames
Factory assembled only If mechanical interlock is installed, no accessory module can be installed in the right pocket.
If mechanical interlock is installed, no accessory module can be installed. If mechanical interlock is installed, no accessory module can be installed in the left pocket.
17/95
The Sentron Sensitrip III circuit Functions available in Sentron Sensitrip circuit breakers breaker is a true RMS current sensing Cont Long InstanShort device. Digital microprocessor Trip Current Time taneous Time circuitry within the electronic trip unit Catalog Number (Description + Suffix) Type Setting Delay Setting Pick Up provides more precise control over Basic Unit + (A) LI the circuit breaker functions. This Basic Unit + (A)G LIG control allows circuit coordination Basic Unit + (A)NT LSI flexibility not available with thermal Basic Unit + (A)NGT LSIG magnetic circuit breakers.
Letter A is used for MD and ND Solid State frame types only.
Typical Trip Unit Labeling and Adjustment Positions for the Sentron Sensitrip Circuit Breaker.
SMD6, SHMD6, SCMD6, SND6, SHND6, SCND6, SPD6, SHPD6
ln = Maximum circuit breaker ampere rating. lr = Current Rating a function of continuous ampere adjustment setting expressed in % of ln .
17/96
A. Adjustable Continuous Amps Rating Switch All Sensitrip III solid state molded case circuit breakers have an adjustable ampere rating switch. Adjustments made to this switch change the continuous current rating of the breaker from 20% to 100% of its maximum trip unit rating depending on the circuit breaker frame. B. Adjustable Long Time Delay Switch All Sensitrip III circuit breakers have an adjustable long time delay switch to allow for selection of long time delays of fixed time intervals at six times the setting of the adjustable continuous amps rating switch. C. Adjustable Instantaneous Pick-Up Switch Sensitrip III circuit breakers with an adjustable instantaneous trip switch allow selection of a tripping point from related to the adjusted circuit breaker Rating (lr).
D. Adjustable Short Time Pick-Up Switch (Optional) Sensitrip III circuit breakers with an adjustable short time pick-up switch allow for selection of short time pick-up in a range from 1.5 to 10 times the setting of the maximum current rating. E. Adjustable Short Time Delay Switch (Optional) Sensitrip III circuit breakers with an adjustable short time pick-up switch also contain a switch for adjustment in time delay. The adjustable short time delay switch allows for either of two modes of short time delays. One range of settings enables the breaker to be set for fixed time delays and the other range of settings enables the breaker to be set for short time delays based on l2t curves.
Adjustable Ground Fault Pick-Up Switch Sensitrip III circuit breakers containing the optional equipment ground fault protection cover the ground fault pick-up range of 20% to 70% of the circuit breaker frame rating. The ground fault pick-up settings also allow for one of three time delays based on 12t curves. For 3-phase, 4-wire systems, an external neutral transformer is required with an ampere rating equal to the trip unit ampere rating.
ln = Maximum circuit breaker ampere rating. lr = Current Rating a function of adjustment setting expressed in % of ln. lg = Ground Fault Pick-up a function of adjustment setting expressed in % of ln.
A k ln = 800 amperes. B k lr = 560 amperes (70% of 800). C k Delay = 20 seconds at 3360 amps (6 x lr). Breaker will trip in 20 seconds with 3360 amperes. D k Short Time Pick-Up Off Instantaneous can be used.
E k Instantaneous set at 10 x lr = 10 x 560 = 5600 amperes. F k Short Time Pick-Up On Set at 8 = 8 x 560 = 4480 amperes. G k Short Time Delay = .5 seconds. (Definite Time) G H Note: k & k are mutually exclusive.
H k l2t switch on .28 seconds @ 6 x 560 = 3360 amperes. (Inverse time) I k Ground Fault Pick-Up set at 40 = 40% of ln = 320 amperes. (Definite Time) J k Ground Fault Delay set at .2 seconds. Breaker will trip in 200 milliseconds with a 400 ampere ground fault.
17/97
The Local Display Unit (LDU) provides a centralized read-out of all Sensitrip III breakers. The device provides a panel mountable display for all trip unit data including phase currents and alarms for up to 32 breakers. Also communicates with other ACCESS devices. Trip Unit Test Set
Type SJD, SLD, SMD, SND, SPD, Portable Spare TS-31 Test Set Interconnecting Cable Catalog Number TS31 TS31CABLE List Price $
The TS-31 test set is used to test the operation of the fault protection functions of the circuit breaker's trip unit, including long-time, short-time, instantaneous, and ground fault by means of secondary current injections. Sensitrip Ammeter Display Unit
Breaker Type SJD, SLD, SMD SND, SPD Catalog Number SADU SADURMK18 List Price $
The Sensitrip Ammeter Display Unit (SADU) provides real-time metering for all Sentron-Sensitrip III Molded Case Circuit Breakers. The unit plugs directly onto the front of the trip unit and provides displays for individual phase currents flowing through the breaker. Additional features include Average, Demand, Ground and Unbalance Current displays, along with impending Trip Status. Current Metering Logs, and a unique diagnostic Trip Log that records the date, time and type of fault for the previous five breaker trips. The device is UL and CSSA certified. The optional panel mount accessory (SADURMK18) allows easy device mounting external from the circuit breaker, in panelboard and switchboard spaces or gutters, with the flexibility of interior panel exterior panel, or wall mounting capability. The 2 x 16 alphanumeric LCD display provides easy viewing of data, such as viewing all three phase currents simultaneously.
SADU Plug-in Mounting
Direct plug-in or Panel Mounting* Trip Unit Powered & Battery back-up 2 x 16 LCD Alphanumeric Display* Ammeter Display Functions
RMS Phase Currents Average Current* Current Demand* Ground Current Current Unbalance (%)* Breaker Status Normal Impending Trip* Time Stamped Trip Log (last 5) Time & Date* Trip Cause: LT, ST, GF, SC Max Log (with date & time) Max Phase Current* Max Average Current* Max Ground Current* Max Unbalance Current* Max Current Demand*
* Unique Features
17/98
Communications Accessories
Selection
Multiplexor Translator
Breaker Type SJD, SLD SMD, SND SPD, STD Features Zone Interlocking Only Full Communications with Zone Interlocking Catalog No MTZ MTA List Price $
The Multiplexor Translator MTZ is an interface device required in zone selective interlock schemes. The MTA combines the zone selective interlocking function with interface to ACCESS Systems.
Telephone Cables
Breaker Type SJD, SLD SMD, SND, SPD Length 8' 15' 25' 50' Catalog No MTC08 MTC15 MTC25 MTC50 List Price $
ACCESS Communications Siemens electronic trip units feature two levels of communication: Zone Selective Interlocking and ACCESS System Open-protocol communications. The trip units are fully equipped for direct integration into ACCESS or compatible communication systems. A multiplexor/Translator (MTA) and Expansion Plug area required for the TYPE TL and Sensitrip trip units when full Access communications is specified. The MTA also has Zone Selective Interlocking capability. Refer to Bulletin IPIM-2211A and Instruction Sheet Pc. No. 411152A00 for additional information. Siemens WinPM.net power monitoring software delivers a powerful energy management system providing sophisticated monitoring capability to a host computer and other components in the electrical distribution system at an affordable cost. It also provides process control, including peak demand, trend analysis, waveform analysis, and harmonic calculations and displays. These functions help pinpoint energy consumption, power quality issues, and the energy cost of any process. Outages and potential outages can be quickly diagnosed and plans can be generated for expansion and preventative plant maintenance. Refer to Bulletins IPIM-2211A for additional information. Communications is accomplished via RS-485 twisted pair wire or modem, providing communications to a remote site and allowing access to multiple plants. With integration of an Access Siemens Power Interface (SPI), communication with Modbus networks is enabled. This part provides the ability to communicate directly to a PC with WinPM.net or any Modbus master.
The Expansion Plug EP is a required isolating device to connect the breaker with the Multiplexor Translator. It is connected to the trip unit on the breaker with a Ribbon Cable, EPC08 e.g., and the Multiplexor Translator with the Telephone Cable (an RJ-11 cable) MTCSB08 e.g.
Built to order. Allow 23 weeks for delivery. Built to order. Allow 68 weeks for delivery.
Factory wired when ACCESS communications or ZSI is ordered for the SB breaker from the factory. When ordered with circuit breaker from the factory.
One MTA or MTZ per eight trip units when required. Always required when multiple MTs are used. One additional cable per each additional MT.
17/99
Mechanical Lug
Selection
For Use With Type(s)
Catalog Number
List Price $
Line Side
1540 BQ, BQH, BQHF BQE, BQF, BL, BLH, HBL, HBQ Switching Neutrals BG, BLG 45100 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 #14#6 AWG Cu #12#6 AWG Al #8#1 AWG Cu #6#1/0 AWG Al #14#10 AWG Cu #12#10 AWG Al #14#6 AWG Cu #12#6 AWG Al #8#6 AWG Cu #8#4 AWG Al #8#4 AWG Cu #8#2 AWG Al #4#1/0 AWG Cu #2#1/0 AWG Al #2#1/0 AWG Cu #1/0#2/0 AWG Al #14#6 AWG Cu #12#6 AWG Al #8#1 AWG Cu #6#1/0 AWG Al #14#6 AWG Cu #12#6 AWG Al #14#6 AWG Cu #12#6 AWG Al #8#1/0 AWG Cu #8#2/0 AWG Al NUT KEEPER PLATE Lugs are integral to Circuit Breaker TC1Q1 TA1Q1
Load Side
1520 2535 4050 5570 80100 110125
Connector wire ranges and cavities are established in conjunction with Table 6.1.4.2.1 of UL 489 standards.
Note: (A) Molded case circuit breakers having a rated ampacity of 125 amperes or less are to be connected with 60 or 75 C wire. Circuit breakers having a rated ampacity greater than 125 amperes shall only be cabled with 75 C cable unless otherwise indicated on the circuit breaker label. Exceptions to this rule are outlined in article 110-14 C(1)(2) of the 2005 National Electrical Code. (B) Connector wire ranges and cavities are established in conjunction with Table 6.1.4.2.1 of UL 489 standards.
Lug is steel. Sold in package of six. One nut keeper plate is required with each lug on the NGG breaker.
17/100
For Use With Type(s) QJ2, QJH2 QJ2H, HQJ2H All 2, 3-pole ED2, ED4, ED6, ED6 ETI, HED4, HHED6 CED6 All 1-pole ED, HED
Lug Wire Range #6 AWG300 kcmil (Cu) #4 AWG300 kcmil (Al) #14#10 AWG (Cu) #12#10 AWG (Al) #10#1/0 (Cu or Al) #3-3/0 (Cu) #1-2/0 (Al) #104 (Cu or Al)
70100 FXD6-A, FD6-A, HFD6, CFD6 HHFD6 SJD6(A), SHJD6(A) SCJD6 JXD2(A), JXD6(A), JD6(A), SJD6(A), HJD6(A), HJXD6(A) HHJXD6, HHJD6, SHJD6(A), CJD6, SCJD6 LXD6(A), LD6(A), SLD6(A), HLD6(A), HLXD6(A), HHLXD6, HHLD6, SHLD6(A), CLD6, SCLD6 LMD6 , LMXD6 , HLMD6 , HLMXD6 , MD6, MXD6, SMD6, HMD6, HMXD6, SHMD6, CMD6, SCMD6 ND6, NXD6, SND6, HND6, HNXD6, SHND6, CND6, SCND6 PD6, HPD6, CPD6 PXD6, HPXD6, SPD6, SHPD6 PD6, PXD6, HPD6, HPXD6, SPD6, SHPD6, RD6, RXD6, HRD6, HRXD6, STD
70250
TA1FD350A
65-200
12
TA2J630
200400
12
TA2J6500
250600
12
TA2J6500
500600
12 13
#1500 kcmil (Cu or Al) 1/0500 kcmil (Cu or Al) 500750 kcmil (Cu or Al) 250500 kcmil (Cu or Al)
500800
12
8001200
12001600
15
TA5P600
12002000
16
TA6R600
Use TA2K500 or TA3K500 only. Used for 100% rated MD/ND frame breakers.
Contains 2 connectors plus 1 NDTS end barrier. Contains 3 connectors plus 1 NDTS end barrier.
17/101
For Use With Type QJ2, QJH2, QJ2H, HQJ2H ED, HED 1, 2 & 3-pole HFD6, HHFD6, CFD6, F(X)D6-A J(X)D2(A), J(X)D6(A), HJD6(A), HHJD6, SHJD6(A), L(X)D6(A), HHLD6, SCD6, HLD6(A), SHLD6(A), CJD6, CLD6, SCJD6, SCLD6 SMD6, M(X)D6, HM(X)D6, HMD6, CMD6, SCMD6, SND6, N(X)D6, HN(X)D6, SHND6, CND6, SCND6 R(X)D6, HR(X)D6 P(X)D6, HP(X)D6, CPD6, SPD6, SHPD6
Circuit Breaker Ampere Rating 60225 1, 2 & 3-pole 30-125 70250 200600
Lug Material Cu Cu Cu Cu
Lug Wire Range #6 AWG250 kcmil (Cu) #10#1/0 (Cu) #6 AWG350 kcmil (Cu) 3/0600 kcmil (Cu) 3/0500 kcmil (Cu) 500750 kcmil (Al) 500600 kcmil (Cu) #1 AWG500 kcmil (Cu) #1 AWG350 kcmil (Cu) 500750 kcmil (Cu) 500750 kcmil (Al) 500750 kcmil (Cu) 500750 kcmil (Al) 300600 kcmil (Cu) 600750 kcmil (Cu/Al)
1 1 1
Al Cu Cu Al Al Cu Al
1 1 1 2 3 2 3 1 1
Compression Lugs
Ampere For Circuit Breaker Types Rating Lugs (contains indicated number of lugs and necessary hardware per kit) ED2, ED4, ED6, HED4, HHED6, CED6 15125 QJ2, QJH2, QJ2-H 125225 F(X)D6-A, HF(X)D6, HHF(X)D6, CFD6 125250 JXD2-A, J(X)D6-A, HJ(X)D6-A, HHJ(X)D6-A, CJD6, SJD6-A, SHJD6-A, 200600 SCJD6, L(X)D6-A, HL(X)D6-A, CLD6, SLD6-A, SHLD6-A, SCLD6 Kits (contain lugs and hardware for complete line or load end of 2 or 3-pole breaker) M(X)D6, HM(X)D6, CMD6, SMD6, SHMD6, SCMD6 N(X)D6, HN(X)D6, CND6, SND6, SHND6, SCND6 500800 9001200 Poles 1, 2, 3 2, 3 2, 3 2, 3 Lugs Per Kit 1 1 1 1 Lug Wire Size #2/0 AWG Cu/Al 350 kcmil Cu/Al 350 kcmil 500 kcmil Catalog Number CCE125 CCQ225 CCF250 CCL600 List Price $
2 3 2 3
6 9 8 12 500 kcmil
Distribution Lugs*
For Circuit Breaker Types ED2, ED4, ED6, HED4, HHED6, CED6 F(X)D6-A, HF(X)D6, HHF(X)D6, CFD6 JXD2-A, J(X)D6-A, HJ(X)D6-A, HHJ(X)D6-A, CJD6-A, SJD6, SHJD6-A, SCJD6, L(X)D6-A, HL(X)D6-A, CLD6-A, SLD6-A, SHLD6-A, SCLD6 Ampere Rating 15-125 70-250 200-600 Poles 1,2,3 2,3 2,3 Lugs Per kit 1 1 1 Wires Per Lug 6 6 6 Lug Wire Size #14-#4 AWG Cu #6-#4 AWG Al #14-#4 AWG Cu #6-#4 AWG Al Catalog Number TA6ED06 TA6FD04 List Price $
* Special purpose wire connectors, not for general use. Built to order. Allow 68 weeks for delivery.
17/102
External Accessories
Selection
Handle Ties
Provide simultaneous switching of 2 adjacent handles. Do not provide common trip. For Use With Breaker Frame(s) BQ, BQH, HBQ, BLH, HBL Catalog Number ECQTH3 List Price $ each Standard Package 50 Wt Lb/ Std Pkg
1
Padlocking Devices
For locking breaker in OFF position. BQXD, BL, BQ, BQH, HBQ, BLH, HBL One pole BL, BLF, BE, BAF Two pole BL, BLF and BE All QJ All BQD, CQD NGG All ED All FD All JD, LD, LMD All MD, ND, PD, RD STD ECQLD3 ECPLD1 ECPLD2 HL9419 BQDPLD HPLG ED2HPL FD6PL1 JD6HPL MN6PLD STDPLD 10 10 10 10 01 01 01 01 01 01 01
1
QTH3
4 4 4 4 8 4 4 4 4 4
1 1 1 1 1 1 1 1 1
Filler Plates
BQ, BQH, HBQ QF3 01
1
1
1 1 1 1 1
4 4 2 2 2
Handle Extensions
For replacement. One extension shipped with breaker. All MD, ND, PD, RD STD EX11 EXSTD 01 2
Terminal Shields
Breaker Type NGG Poles 3 Catalog Number TSSG3A List Price $ each Standard Package 1
17/103
External Accessories
Selection
Mounting Clips
For Use With Breaker Frame(s) BQ, BQH Number of Poles 1 Catalog Number MB120 List Price $ each Standard Package 20 Wt Lb Std Pkg
1
MB120
2 1 112
1 1 1 1
CQD, CQD6
4 4 4
NGG
4 1 4 1 4
4 4
SMB6R (6 shown)
QML12
4 1 4 1 4
1
1
1
I0204ML1125
4 1
1
4 1
1 1 1
4 4 4
MI Mechanical Interlocks
For Use With Breaker Type(s) BQ All QJ All FD All JD, LD All LMD All MD All ND All PD, RD STD Panel Mounted CSO MI5444 MI5413 MI5406 MI5404 MI5404 MI5405 STDMIF32 Plug-in Mounted ECQML12 MI5444
Complete with 1 two breakers
Standard Package 10 1
Wt Lb Std Pkg
1
1 1 1 3 3
1 1 1
Built to order. Allow 23 weeks for delivery. Built to order. Allow 68 weeks for delivery. Kit consists of 4 screws and washers. Consists of 1 screw and washers (order 100). Consists of 1 screw and washers (order 50).
With mechanical interlock in place, no accessory can be installed into circuit breaker right pole. Addition of the mechanical interlock will prevent accessory installation in the left pole. Sold only in standard package quantities. Multiply List Price Each times package quantity for full price.
Each package contains 5 strips of 6 each. Each strip can be broken at perforations for 1, 2 or 3-pole use. Mechanical interlock is not designed for use within Siemens panelboards. CSO = Consult Sales Office for pricing.
17/104
External Accessories
Selection
List Catalog List Catalog Price $ Number Price $ Number RHOEBO RHOFBO RHOJBO RHOLMBO RHOH RHONBO
JD, LD CRHOJSD
RHOH
CRHOH
D11CEU2
For CQD and NGG red emergency handle, order assembly RHOCQVDE (includes handle and operator). For CQD and NGG in a NEMA 3R enclosure, order CQDOP34 operator ($ ), RHOH handle and RHOSVD shaft. For CQD and NGG in a NEMA 4 or 4X enclosure, order CQDOP34 operator, RHOH4 handle and RHOSVD shaft.
Variable Depth
F6RHV9
Rotary Handle
RHOCQVD
Built to order. Allow 23 weeks for delivery. Built to order. Allow 68 weeks for delivery. For use on 3-pole ED frame only.
Meets the requirements of NFPA 79, section 5.3.3.1 for locking external operator disconnecting devices. For 3 or 3R, order shaft and breaker operator as shown, and handle RHOH. For 4 & 4X, order handle RHOH4. List Price adder.
17/105
External Accessories
Selection
Cable Handle
Frames ED
1, 3 (R), FHOE036 12 4 (x) 1, 3 (R), FHOF036 12 4 (x) 1, 3 (R), FHOJ036 12 4 (x) 1, 3 (R), FHOLM036 12 4 (x)
Breaker Operator
FD
Max Flex
LMD
1, 3 (R), MD, ND, FHON048 12 PD, RD, SMD, SND, 4 (x) SPD
Max-Flex handles are available with solid black handles instead of the customary red for on flange handle. These are preferred for use in IECmarkets, where red handles have specific meaning. Order components separately, appending the letter i to the catalog number (e.g. FHOHI).
Max-Flex handles are available with solid black handles instead of the customary Red for On flange handle. These are preferred for use in IECmarkets, where red handles have specific meaning. Order components separately, appending the letter i to the catalog number (e.g. FHOHI).
FDFBFR
Built to order. Allow 68 weeks for delivery. For 1- or 2-pole breaker order FHOED036 complete kit or FHOEDBO breaker operator only. Use MFHM3R handle.
48 inch cable is standard length for M through R frame Max-Flex operators. Meets requirements of NFPA 79, section 5.3.3.1 for locking external operator disconnecting devices
17/106
External Accessories
Selection/Dimensions
Breaker Frame FD
Hinged to Open Right MOF6024DC MOF6048DC MOF6125DC MOJ6024DC MOJ6048DC MOJ6125DC MOLMD6024DC MOLMD6048DC MOLMD6125DC
List Price $
Hinged to Open Right MOF6120 MOF6240 MOJ6120 MOJ6240 MOLMD6120 MOLMD6240 MOMN6120 MOMN6240
List Price $
JD, LD
120 240
To order FD through RD motor operators with Left side hinges, add L to catalog number (e.g. MOF6120L). List prices are the same.
Dimensions
Frame ED FD JD, LD, LMD MD, ND, PD, RD A 7.04 9.50 11.00 16.00 B 4.31 4.55 7.50 9.00 C 1.60 0.79 D 4.31 6.84 8.34 9.83 E 13.84 9.70 9.85 13.13 F 8.84 7.58 7.74 10.13
Operating Currents
On Catalog Number MOE6120 MOE6240 MOF6120/L MOF6240/L MOLMD6120/L MOJ6120/L MOJ6240/L MOMN6120/L MOMN6240/L In-Rush (Amps) 10.25 5.2 13.6 7.6 13.6 13.6 7.6 30.2 14.7 Running (Amps) 2.3 1.1 5.5 3.5 6 6 3.5 13.2 6 Time (msec) 550 500 200 200 210 210 217 240 260 Off In-Rush (Amps) 10 5 13.6 7.6 13.6 13.6 7.6 30.2 14.7 Running (Amps) 2.3 1 5.5 3.5 6 6 3.5 13.2 6 Time (msec) 400 330 175 185 185 185 185 210 230 Reset (Amps) 2.3 1.1 5.5 3.5 6 6 3.5 13.2 6
Front View
Bottom View
For inches / millimeters conversion, see Application Data section. Built to order. Allow 68 weeks for delivery.
17/107
External Accessories
Selection
PL5797
RS4755 RS4756
Rear-Connecting Studs
For Use With Breaker Frames All ED Ampere Rating 100 100 100 100 250 250 400 400 600 600 Extension Behind Breaker (inches) 2.38 2.38 4.88 4.88 3.12 7.06 5.85 11.20 5.85 11.20 Line Side Catalog Number RS2643 RS2641 RS4756 RS4755 RS5774 RS5773 RS5784 RS5783 List Price $ Load Side Catalog Number RS2644 RS2642 RS4756 RS4755 RS5774 RS5773 RS5784 RS5783 CLRSJL3 5.85 11.20 5.50 8.00 RS5788 RS5787 RS5786 RS5785 RS5788 RS5787 RS5786 RS5785 List Price $
Description Line Side (Short) Load Side (Short) Line Side (Long) Load Side (Long) Short Long Short Long Short Long
All FD All JD All LD CJD, SCJD CLD, SCLD LM(X)D6, HLM(X)D6 All MD, ND
Add required shield kit. 800 1200 1200 Short Long Short Long
Built to order. Allow 68 weeks for delivery. Furnished at no extra charge when ordered with plug-in mounting assembly. Each piece catalog number consists of (1) mounting block assembly and required tulip assemblies (2) for 2-pole, (3) for 3-pole
For vertical bus mounting for horizontal, substitute PC5665 for PC5664 and PC5667 for PC5666. Price includes one current stud, insulating tube, stud nuts and terminal shields, when required.
For proper electrical clearance, studs must alternate between short and long stud lengths on circuit breaker poles (e.g. SLSLSL or LSLSLS).
17/108
Tulip Assemblies
Base
Note: The information provided on this and the next page is intended for reference and recommendation only. Because several variables can act on a circuit breakers performance at the same time, the data below is based less on controlled testing, than on experience and engineering judgment. Contact Siemens for further information on special conditions and treatment. High Ambient Temperatures Because thermal-magnetic trip breakers are temperature sensitive and calibrated for a specific ambient of 40 C (104 F) (average enclosure temperature), a higher ambient will cause the breaker to trip at lower current than its nameplate rating, in other words, causing the breaker to derate (see Table 1). Similarly, the current carrying capacity of a circuit conductor is based upon a certain ambient temperature, a higher ambient will reduce its current carrying capacity, causing it to derate. Thus, with a fluctuating temperature, a thermal-magnetic breaker will derate nearly parallel with its connected circuit conductors and maintain close circuit protection. If the application temperature exceeds 40 C (104 F) and is known, either a breaker specially calibrated for the higher ambient or one oversized according to Table 1 may be selected. In a case such as this, the circuit conductors should be oversized as well. Siemens Sensitrip III and Type SB Encased Systems Breakers are insensitive to temperature changes. However, they do include circuitry to protect the components from abnormally high temperatures. Moisture Corrosion For atmospheres having high moisture content and / or where fungus growth is prevalent, a special preventive treatment may be required. Where the air is heavily laden with corrosive elements, breakers made with special corrosion-resistant finishes may be required. Altitude Reduced air density at altitudes greater than 6600 ft. (2000 meters) affects the ability of a molded case circuit breaker to transfer heat and interrupt faults. Therefore, circuit breakers applied at these altitudes should have interrupting, insulation and continuous currents derated as indicated in Figure 1. Table 1 Temperature Derating Data for Thermal-Magnetic Breakers
Reference Ampere Rating at 40 C (104 F) 0015 0020 0025 0030 0035 0040 0050 0060 0070 0090 0100 0125 0150 0175 0200 0225 0250 0300 0350 0400 0500 0600 0700 0800 0900 1000 1200 1400 1600 1800 2000 Ampere Rating at: 25 C 50 C (77 F) (122 F) 0017 0013 0022 0018 0028 0023 0033 0028 0039 0030 0044 0037 0055 0046 0066 0056 0077 0065 0099 0084 0110 0094 0137 0114 0165 0136 0192 0159 0220 0182 0247 0205 0275 0235 0330 0276 0385 0325 0440 0372 0550 0468 0660 0564 0770 0658 0880 0754 0990 0828 1100 0900 1320 1090 1540 1304 1760 1500 1980 1690 2200 1880
60 C (140 F) 0011 0016 0021 0026 0025 0034 0042 0052 0060 0078 0087 0100 0120 0140 0160 0180 0220 0252 0301 0340 0435 0525 0613 0704 0749 0825 1000 1148 1320 1485 1650
JD LD
MD
ND
PD RD
13,000 (4,000) Altitude in Feet (Meters) 12,000 (3,675) 11,000 (3,350) 10,000 (3,000) 9,000 (2,750) 8,000 (2,400) 7,000 (2,100) 6,000 (1,800) 1.0 .95 .90 .85 .80 .75
17/109
Modifications
General/Selection
A variety of internal and external accessories, as well as modifications, are available to adapt Siemens circuit breakers to special installation requirements. UL listed internal accessories for 100 through 2000A circuit breakers are field-addable. Internal accessories fine tune an electrical distribution system, allowing control of the circuit breakers to meet special application requirements. For example, emergency situations may dictate tripping critically placed circuit breakers quickly. Shunt trips accomplish this conveniently and efficiently. Or, when voltage drops are a concern, undervoltage trips automatically open the circuit breaker at a predetermined voltage level. A wide range of external operating and mounting accessories is also available. For example, face, shallow, and back mounting plates are ideal for tailoring BQ circuit breakers to OEM applications. A complete line of operating handles and handle-blocking devices meet switchboard, enclosure and safety needs. Plug-in mounting assemblies, which simplify switchboard mounting of circuit breakers and permit breaker removal without disconnecting bus or cable connections, are available.
50C Ambient Calibration Not UL listed and not available for solid state, 100% rated breakers or 400HZ calibrated breakers. For BL Type Circuit Breakers Add suffix M to catalog number (Example: B120M) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .No Charge For BQ, QJ2, and ED Frame Circuit Breakers Replace B in catalog number with M . . . . . . . . . . . . . . . . . . . . . . . .No Charge (Example: BQ3M060, QJ23M200, ED63M060) For FD, JD, LD, LMD, MD, ND, PD, and RD Frame Circuit Breakers Non-Interchangeable Trip (3pole only) . . . . . . . . . . . . . . . . . . . . . . . . . . . .No Charge Replace B in catalog number with M (Example: FXD63M225, JXD63M400) Interchangeable Trip (trip unit only, 3pole only) . . . . . . . . . . . . . . . . . . . .No Charge Replace T in catalog number with W (Example: FD63W200, JD63W400) 400 HZ Calibration UL Listed (5KA IR) For BQ & BL Type Circuit Breakers (200A max.) . . . . . . . . . . . . . . . . . . . . .Add 25% to list price Add suffix Y to catalog number Not UL Listed For all other Circuit Breakers, see derating tables on pages 17/111 & 17/112 and order standard circuit breakers. Fungus Proofing All BQD, CQD, NGG, ED, FD, JD, LD, LMD, MD, ND, PD, RD, DG, FG, JG, LG, MG, NG, and PG Frame Circuit Breakers are inherently fungus resistant and do not require special treatment. In accordance with MIL-T-152 For BL, and BQ Type Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Add $10.00 net per pole Consult Sales Office for Availability For all other Circuit Breaker Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Add $160.00 net per device Consult Sales Office for Availability Certificate of Compliance with Test Report (catalog number CERT OF COMP.) Add $210.00 net Certificate of compliance testing must be performed on the actual device being shipped. The certificate cannot be provided after initial shipment. Order for devices with COC requirement must be placed directly with the factory by the sales office and shipped directly to the end user.
Ordering Information
For NAVAL label, add $75. net per catalog number per order. Order must be placed directly with the factory by Siemens Sales Office.
Types BQD/CQD NGG NGB ED2, ED4, ED6, IIED4, HED6 CED6 FD6, FXD6, HFD6, HFXD6 CFD6 JXD2, JD6, JXD6, LXD6, LD6, HJD6, HJXD6, HLD6, HLXD6 HHJD6, HHJXD6, HHLD6, HHLXD6 CJD6, CLD6 MD6, MXD6, HMD6, HMXD6, CMD6, ND6, NXD6, HND6, HNXD6, CND6 PD6, PXD6, HPD6, HPXD6, CPD6, RD6, RXD6, HRD6, HRXD6 UL File E10848, Vol 10, Sec 1 E10848, Vol 10, Sec 2 E10848, Vol 10, Sec 3 E10848, Vol 4, Sec 11 E10848, Vol 4, Sec 13 E10848, Vol 4, Sec 17 E10848, Vol 4, Sec 18 E10848, Vol 4, Sec 8 E10848, Vol 4, Sec 20 E10848, Vol 4, Sec 14 E10848, Vol 4, Sec 15 E10848, Vol 4, Sec 19
17/110
400 Hz Systems
Siemens molded case circuit breakers can be applied for overcurrent protection on 400Hz systems, commonly used to power computer installations, aircraft, military and other specialty equipment. Below are basic guidelines. Circuit Breaker Derating Required This table lists the maximum continuous current carrying capacity for Siemens breakers at 400Hz. Due to the increased resistance of the copper sections resulting from the skin effect produced by eddy currents at these frequencies, circuit breakers in many cases require derating. The thermal derating on these devices is based upon 100%, three phase application in open air in a maximum of 40 C (104 F) with 48 in. (1219 mm) of the specified cable or bus at the line and load side. Additional derating of not less than 20% will be required if the circuit breaker is to be utilized in an enclosure. Further derating may be required if the enclosure 400Hz Breakers
Siemens Breaker Type Maximum Continuous Ampere Rating At 40 C (104 F) 60HZ 400HZ Enclosed Open Air Open Air After Derating 015 015 012 020 020 016 15 15 12 20 20 16 25 25 20 30 30 24 35 35 28 40 40 32 45 43 34 50 48 38 60 57 46 70 67 54 80 76 61 90 86 69 100 95 76 110 105 84 125 119 95 50 48 38 60 57 46 70 63 50 80 72 58 90 80 64 100 90 72 110 95 75 125 105 84 150 125 100 100 90 72 110 95 75 125 105 84 150 125 100 175 140 112 200 160 128 225 180 144 250 200 160 75 C (167 F) Copper Cable per Pole No of Wire Pieces Size 1 #14 1 #12 1 #14 1 #12 1 #10 1 #10 1 #10 1 #8 1 #8 1 #8 1 #6 1 #4 1 #4 1 #3 1 #3 1 #2 1 #1 1 #8 1 #6 1 #4 1 #4 1 #3 1 #3 1 #2 1 #1 1 #1/0 1 #3 1 #2 1 #1 1 #1/0 1 #2/0 1 #3/0 1 #4/0 1 250 kcmil Siemens Breaker Type Maximum Continuous Ampere Rating At 40 C (104 F) 60HZ 400HZ Enclosed Open Air Open Air After Derating 250 210 168 300 240 192 350 260 208 400 300 240 250 210 210 300 240 240 350 260 260 400 300 300 400 300 240 500 375 300 600 420 336 600 430 360 700 500 400 800 560 448 600 430 430 700 500 500 800 560 560 800 560 448 900 600 480 1000 650 520 1200 780 624 900 600 600 1000 650 650 1200 780 780 1200 780 624 1400 850 680 1600 960 768 1200 780 780 1400 850 850 1600 960 960 75 C (167 F) Copper Cable per Pole No of Wire Pieces Size 1 250 kcmil 1 350 kcmil 1 500 kcmil 2 #2/0 1 250 kcmil 1 350 kcmil 1 500 kcmil 2 #3/0 2 #3/0 2 250 kcmil 2 350 kcmil 2 350 kcmil 3 250 kcmil 3 300 kcmil 2 350 kcmil 3 250 kcmil 3 300 kcmil 3 300 kcmil 3 350 kcmil 3 400 kcmil 4 350 kcmil 3 350 kcmil 3 400 kcmil 4 350 kcmil 4 400 kcmil 4 500 kcmil 5 500 kcmil 4 400 kcmil 4 500 kcmil 5 500 kcmil
ambient temperature exceeds 40 C (104 F). Cable and Bus Sizing The cable and bus sizes to be utilized at 400Hz are not based on standard National Electric Codes tables for 60Hz application. Larger cross sections are necessary at 400Hz. All bus bars specified are based upon mounting the bars in the vertical plane to allow maximum air flow. All bus bars are spaced at a minimum of 0.25 in. (6 mm) apart. Mounting of bus bars in the horizontal plane will necessitate additional drafting. Edgewise orientation of the bus may change the maximum ratings indicated. If additional information is required for other connections of cable or bus, contact Siemens for information. Application Recommendations It is recommended that temperatures be measured on the line and load terminals or T-connectors of the center pole. These
are usually the hottest terminals with a balanced load. A maximum temperature of 75 C (35 C over a maximum ambient of 40 C) would verify the particular application. Temperature profiles taken on these breakers can be correlated to ensure that the hottest points within the breaker are within the required temperature limits. Factory Configuration When required, molded case circuit breakers may be factory calibrated for 400Hz application. These breakers are specially labeled for 400Hz usage and their nameplate current rating will include the necessary derating factory. The highest Maximum Continuous Amperes rating at 400Hz, found in the table below approximates the highest specially calibrated 400Hz nameplate ampere rating available for a given frame size. Contact Siemens for ordering information on other breakers applied in 400Hz systems.
JG
JG 100% Rated
NGG
LG
MG
MG 100% Rated
NG
DG
NG 100% Rated
PG
PG 100% Rated
FG
The information provided on this page is intended for reference and recommendation only. Because several variables can act on a circuit breakers performance at the same time, the data above is based less on controlled testing, than on experience and engineering
judgment. Contact Siemens for further information on special conditions and treatment. Additional derating may be required if the ambient temperature is greater than 40C (104F).
Calculated after derating to compensate for the heating of the copper conductor, caused by the skin effect generated by eddy currents produced at 400/415HZ.
17/111
400 Hz Systems
Siemens molded case circuit breakers can be applied for overcurrent protection on 400Hz systems, commonly used to power computer installations, aircraft, military and other specialty equipment. Below are basic guidelines. Circuit Breaker Derating Required This table lists the maximum continuous current carrying capacity for Siemens breakers at 400Hz. Due to the increased resistance of the copper sections resulting from the skin effect produced by eddy currents at these frequencies, circuit breakers in many cases require derating. The thermal derating on these devices is based upon 100%, three phase application in open air in a maximum of 40 C (104 F) with 48 in. (1219 mm) of the specified cable or bus at the line and load side. Additional derating of not less than 20% will be required if the circuit breaker is to be utilized in an enclosure. Further derating may be required if the enclosure 400Hz Breakers
Siemens Breaker Type Maximum Continuous Ampere Rating At 40 C (104 F) 60HZ 400HZ Enclosed Open Air Open Air After Derating 015 015 012 020 020 016 025 025 020 030 030 024 035 035 028 040 040 032 045 043 034 050 048 038 060 057 046 070 067 054 080 076 061 090 086 069 100 095 076 110 105 084 125 119 095 070 063 050 080 072 058 090 080 064 100 090 072 110 095 075 125 105 084 150 125 100 175 140 112 200 160 128 225 180 144 250 200 160 200 170 136 225 190 152 250 210 168 300 240 192 350 260 208 400 300 240 200 170 170 225 190 190 250 210 210 300 240 240 350 260 260 400 300 300 75 C (167 F) Copper Cable per Pole No of Wire Pieces Size 1 #14 1 #12 1 #10 1 #10 1 #10 1 #8 1 #8 1 #8 1 #6 1 #4 1 #4 1 #3 1 #3 1 #2 1 #1 1 #4 1 #4 1 #3 1 #3 1 #2 1 #1 1 #1/0 1 #2/0 1 #3/0 1 #4/0 1 250 kcmil 1 #3/0 1 #4/0 1 250 kcmil 1 350 kcmil 1 500 kcmil 2 #3/0 2 #3/0 2 #4/0 1 250 kcmil 1 350 kcmil 1 500 kcmil 2 #3/0 Siemens Breaker Type Maximum Continuous Ampere Rating At 40 C (104 F) 60HZ 400/415HZ Enclosed Open Air Open Air After Derating 0250 0210 168 0300 0240 192 0350 0260 208 0400 0300 240 0450 0340 272 0500 0375 300 0600 0420 336 0250 0210 210 0300 0240 240 0350 0260 260 0400 0300 300 0450 0340 340 0500 0375 375 0600 0420 420 0500 0400 320 0600 0430 360 0700 0500 400 0800 0560 448 0500 0400 400 0600 0430 430 0700 0500 500 0800 0560 560 0800 0560 448 0900 0600 480 1000 0650 520 1200 0780 624 0900 0600 600 1000 0650 650 1200 0780 780 1200 0780 624 1400 0850 680 1600 0960 768 1200 0780 780 1400 0850 850 1600 0960 960 1600 0960 768 1800 1080 864 2000 1200 960 75 C (167 F) Copper Cable per Pole No of Wire Pieces Size 1 250 kcmil 1 350 kcmil 1 500 kcmil 2 #3/0 2 #4/0 2 250 kcmil 2 350 kcmil 1 250 kcmil 1 350 kcmil 1 500 kcmil 2 #3/0 2 #4/0 2 250 kcmil 2 350 kcmil 2 250 kcmil 2 350 kcmil 3 250 kcmil 3 300 kcmil 2 250 kcmil 2 350 kcmil 3 250 kcmil 3 300 kcmil 3 300 kcmil 3 350 kcmil 3 400 kcmil 4 350 kcmil 3 350 kcmil 3 400 kcmil 4 350 kcmil 4 400 kcmil 4 500 kcmil 5 500 kcmil 4 400 kcmil 4 500 kcmil 5 500 kcmil 5 500 kcmil 5 500 kcmil 6 500 kcmil
ambient temperature exceeds 40 C (104 F). Cable and Bus Sizing The cable and bus sizes to be utilized at 400Hz are not based on standard National Electric Codes tables for 60Hz application. Larger cross sections are necessary at 400Hz. All bus bars specified are based upon mounting the bars in the vertical plane to allow maximum air flow. All bus bars are spaced at a minimum of 0.25 in. (6 mm) apart. Mounting of bus bars in the horizontal plane will necessitate additional drafting. Edgewise orientation of the bus may change the maximum ratings indicated. If additional information is required for other connections of cable or bus, contact Siemens for information. Application Recommendations It is recommended that temperatures be measured on the line and load terminals or T-connectors of the center pole. These
are usually the hottest terminals with a balanced load. A maximum temperature of 75 C (35 C over a maximum ambient of 40 C) would verify the particular application. Temperature profiles taken on these breakers can be correlated to ensure that the hottest points within the breaker are within the required temperature limits. Factory Configuration When required, molded case circuit breakers may be factory calibrated for 400Hz application. These breakers are specially labeled for 400Hz usage and their nameplate current rating will include the necessary derating factory. The highest Maximum Continuous Amperes rating at 400Hz, found in the table below approximates the highest specially calibrated 400Hz nameplate ampere rating available for a given frame size. Contact Siemens for ordering information on other breakers applied in 400Hz systems.
MD6, MXD6, HMD6, HMXD6, CMD6 MD6, MXD6, HMD6, HMXD6, CMD6 100% Rated ND6, NXD6 HND6, HNXD6, CND6 ND6, NXD6 HND6, HNXD6, CND6 100% Rated PD6, PXD6, HPD6, HPXD6, CPD6, PD6, PXD6, HPD6, HPXD6, CPD6 100% Rated RD6, RXD6, HRD6, HRXD6 80% Rated
The information provided on this page is intended for reference and recommendation only. Because several variables can act on a circuit breakers performance at the same time, the data above is based less on
controlled testing, than on experience and engineering judgment. Contact Siemens for further information on special conditions and treatment. Additional derating may be required if the ambient
temperature is greater than 40C (104F). Calculated after derating to compensate for the heating of the copper conductor, caused by the skin effect generated by eddy currents produced at 400/415HZ.
17/112