Mechanical Data Sheets for Sump Evacuating Pump (P 407)

Tabulation of Revised Pages

Sheet no. Rev.01 Rev.02 Rev.03 Rev.04 Rev.05 Sheet no. Rev.01 Rev.02 Rev.03 Rev.04 Rev.05

01 X X

02 X X

03 X

04 X X
Mechanical Data Sheets for Sump Evacuating Pump (P 407)

Page 3 of 4

Class : 1
SUBMERSIBLE PUMP DATA SHEET
1
2
APPLICABLE TO:
FOR
● PROPOSAL ○ PURCHASE
UNIT
◘ AS BUILT
REV.

3 SITE SERVICE Sump Evacuating Pump (P 407)


4 NO. REQ. 1 Main PUMP SIZE TYPE Lift Pump (SUBMERSIBLE) NO. OF STAGES

5 MANUFACTURER MODEL SERIAL NO.

6 NOTE: ○ INDICATES INFORMATION COMPLETED BY PURCHASER □ BY MANUFACTURER


◘ BY MANUFACTURER OR PURCHASER

7 ● GENERAL
8 PUMP ITEM NO. P-407 OPERATION ○ CONTINUOUS ● INTERMITTENT

9 PURCHASER'S REQUIREMENTS CONSTRUCTION


10 LIQUID Water NOZZLES SUCTION DISCHARGE BALANCE DRUM

11 PUMPING TEMP. (°C) NORMAL 35~42 SIZE (Note 7)


12 MAXIMUM LOCATION TOP
13 MINIMUM FACING RF
14 ACT. DENSITY (kg/m3) 991~994 RATING

15 VAPOR PRESSURE (bara) 0.09 □ DESIGN PRESSURE (barG):

16 VISCOSITY (CENTIPOISE) 0.63~0.719 □ HYDRAULIC TEST PRESSURE (barg) 1.5 * MAWP


17 ● CAPACITY (m 3 / h) NORMAL 2 □ MAXIMUM ALLOWABLE WORKING PRESSURE AT RATED TEMP.(barG):

18 RATED 2.2
19 ● DISCHARGE PRESSURE (barg) 0.97
FLOW RATE / HEAD CURVE SUPPLIED: YES ● NO ○
□ DRIVER SPEED (rpm)
20 ● SUCTION PRESSURE (barg) MAX/RATED 0
□ EFFICIENCY AT REQUIRED PERFORMANCE:
21 ● DIFFERENTIAL HEAD (m) 10
□ MIN. CONTINUOUS FLOW (m3 / h) MECHANICAL
22 ● DIFFERENTIAL PRESSURE (bar) 0.97 THERMAL
23 ● NPSH AVAILABLE (m) 9.3 □ RATED POWER (KW):
24 ● BHP (KW) Note 4 □ MAX. HEAD WITH RATED IMPELLER (m):
25 ● MAX SOUND PRESS. LEVEL REQ'D 85 dBA @ 1 Meter □ MAX. POWER WITH RATED IMPELLER (m):

26 ● INSTALLATION DEPTH (m) □ MINIMUM REQUIRED SUBMERGENCE (mm):

27 ● SITE AND UTILITY DATA (Note 1) □ IMPELLER DIAMETER (mm)


RATED MIN. MAX.
28 LOCATION: (2.1.29)

29 ● OUTDOOR ● UNHEATED ○ PARTIAL SIDES ◘ IMPELLER TYPE : (NOTE 9) □ Free passage size (mm):

30 ○ ELECTRICAL AREA CLASSIFICATION ( 2.1.22 / 3.1.5) ◙ IMPELLER MOUNTING: OVERHUNG

31 ZONE GR DIV Safe ◘□ SHAFT SEALING:


SEAL MANUFACTURER:
DUAL MECHANICAL SEAL
32 SITE DATA (2.1.29)
□ BEARING TYPE: RADIAL :
33 ● ELEVATION 0 (m) BAROMETER 0.995 - 1.02 (bara)
AXIAL :
34 ● RANGE OF AMBIENT TEMPS: MIN/MAX -3.5 52 (°C)
□ LUBRICATION TYPE:
35 ● RELATIVE HUMIDITY: MIN / MAX 45 90 (%)

36 UNUSUAL CONDITIONS (2.1.23) ○ DUST ○ FUMES


GREASE
◘ OIL BATH
◘ OTHER

37 ○ OTHER
38 MOTOR DRIVE (NOTE 22 ) ACCESSORIES 02
39 ◘ MANUFACTURER ◙ INSTALLATION ACCESSORIES:

40 □ 1.5 (KW) □ (RPM)


◙ DUCT FOOT BEND
◙ GUIDE BAR / PIPE
◙ LIFTING CHAIN

41 ◘ SERVICE FACTOR
◙ CLAW
◙ ACHOR/FIXATION BOLT & NUTs

42 ◙ VOLTS/PHASE/HERTZ 400 / 3 / 50
◙ WATER IN OIL SENSOR

43 ◙ ENCLOSURE IP68
◙ MOISTURE SENSOR

44 ◙ INSULATION / TEMP. RISE F/B


◙ OTHER: (Note 2)

46 ◘ LUBE APPLICABLE STANDARDS


47 ◘ RTD FOR MOTOR WINDING IF REQUIRED ○ API 610 ○ ISO 5199
48 ◙ STARTING METHOD OPEN VALVE ○ ISO 2858 ● OTHER
Mechanical Data Sheets for Sump Evacuating Pump (P 407)

Page 4 of 4

Class : 1
SUBMERSIBLE PUMP DATA SHEET
MATERIAL INSPECTION AND TEST REV.

1 MATERIAL OF CONSTRUCTION TEST NON -WIT WIT

2 CASE CAST IRON IMPELLER CAST IRON HYDROSTATIC ○ ●


3 WEAR RINGS CAST IRON SHAFT 12% Chrome PERFORMANCE ○ ●
4 DUCT FOOT BEND By Vendor COMPLETE UNIT TEST ○ ●
5 GUIDE BAR / PIPE By Vendor □ WEIGHTS
6 LIFTING CHAIN Stainless Steel WEIGHT OF PUMP & MOTOR (kg)

7 OTHERS By Vendor WEIGHT OF INSTALLATION ACCESSORIES (kg)


8 TOTAL WEIGHT (kg)

9 REMARKS
10 NOTE 1: Hydraulic calculation is based on PID " KHYCO-DD-000-PR-PID-0051".

NOTE 2: Pump shall be vertically submerged type for installation in underground sump
11
12 NOTE 3: Pump differential head and discharge pressure are quoted at bottom of sump.
13 NOTE 4: Estimated efficiency is 13% . Estimated shaft power is 0.5 KW.
14 NOTE 5: Vendor to confirm pump motor is suitable for end of curve operation.
16 NOTE 6: Suction strainer to be included in supply.
17 NOTE 7: Discharge Line Diameter/Rating/Class: 3/4"/ #150).
18 NOTE 8: Hydraulic Power Per Pump: 0.1 kW.
22 NOTE 9: Impeller shall be non-clog and suitable for specified pumping liquid.
24 NOTE 10: Material test certificate 3.1 is required for wetted parts.
27 NOTE 11: [Deleted]
28 Note 12: [Deleted]
29 Note 13: [Deleted]
30 Note 14: Motors shall be capable of starting under 80% nominal voltage at motor terminal box.
31 NOTE 15: Referred process data sheet is KHYCO-DD-000-PR-DSH-0016 Rev.00
32 Note 16: Performance curve shall be submitted and rated flow shall be within allowable operating region.
33 Note 17: Design pressure shall cover pump shutoff pressure plus maximum suction pressure.
34 Note 18: Pumping liquid is not flammable.
35 Note 19: Vibration values shall be recorded during the test.
36 Note 20: 3 mm CA is required for casing.
37 Note 21: Max allowable pressure at shut off shall not be exceed 1.2barg 02
Note 22: Specification for LV Motor is KHYCO-BD-000-EL-SPC-1011 .Datasheet for LV Motors KHYCO-DD-000-EL-DSH-0010, to be filled and be
02
38 provided by vendor
Note 23: For Instrument scope of work include selection of field instrument , Ingress Protection, Ex protection, power supply and etc., please
02
39 refer to "Technical Specification for Instrumentation and control for packages: KHYCO-DD-000-IN-SPC-0006".
40 Note 24: Design Temperature : -3.5 / 100 ͦC 02