Mechanical Data Sheets For Sump Evacuating Pump (P 407)
Mechanical Data Sheets For Sump Evacuating Pump (P 407)
Sheet no. Rev.01 Rev.02 Rev.03 Rev.04 Rev.05 Sheet no. Rev.01 Rev.02 Rev.03 Rev.04 Rev.05
01 X X
02 X X
03 X
04 X X
Mechanical Data Sheets for Sump Evacuating Pump (P 407)
Page 3 of 4
Class : 1
SUBMERSIBLE PUMP DATA SHEET
1
2
APPLICABLE TO:
FOR
● PROPOSAL ○ PURCHASE
UNIT
◘ AS BUILT
REV.
7 ● GENERAL
8 PUMP ITEM NO. P-407 OPERATION ○ CONTINUOUS ● INTERMITTENT
18 RATED 2.2
19 ● DISCHARGE PRESSURE (barg) 0.97
FLOW RATE / HEAD CURVE SUPPLIED: YES ● NO ○
□ DRIVER SPEED (rpm)
20 ● SUCTION PRESSURE (barg) MAX/RATED 0
□ EFFICIENCY AT REQUIRED PERFORMANCE:
21 ● DIFFERENTIAL HEAD (m) 10
□ MIN. CONTINUOUS FLOW (m3 / h) MECHANICAL
22 ● DIFFERENTIAL PRESSURE (bar) 0.97 THERMAL
23 ● NPSH AVAILABLE (m) 9.3 □ RATED POWER (KW):
24 ● BHP (KW) Note 4 □ MAX. HEAD WITH RATED IMPELLER (m):
25 ● MAX SOUND PRESS. LEVEL REQ'D 85 dBA @ 1 Meter □ MAX. POWER WITH RATED IMPELLER (m):
29 ● OUTDOOR ● UNHEATED ○ PARTIAL SIDES ◘ IMPELLER TYPE : (NOTE 9) □ Free passage size (mm):
41 ◘ SERVICE FACTOR
◙ CLAW
◙ ACHOR/FIXATION BOLT & NUTs
42 ◙ VOLTS/PHASE/HERTZ 400 / 3 / 50
◙ WATER IN OIL SENSOR
43 ◙ ENCLOSURE IP68
◙ MOISTURE SENSOR
Page 4 of 4
Class : 1
SUBMERSIBLE PUMP DATA SHEET
MATERIAL INSPECTION AND TEST REV.
9 REMARKS
10 NOTE 1: Hydraulic calculation is based on PID " KHYCO-DD-000-PR-PID-0051".
NOTE 2: Pump shall be vertically submerged type for installation in underground sump
11
12 NOTE 3: Pump differential head and discharge pressure are quoted at bottom of sump.
13 NOTE 4: Estimated efficiency is 13% . Estimated shaft power is 0.5 KW.
14 NOTE 5: Vendor to confirm pump motor is suitable for end of curve operation.
16 NOTE 6: Suction strainer to be included in supply.
17 NOTE 7: Discharge Line Diameter/Rating/Class: 3/4"/ #150).
18 NOTE 8: Hydraulic Power Per Pump: 0.1 kW.
22 NOTE 9: Impeller shall be non-clog and suitable for specified pumping liquid.
24 NOTE 10: Material test certificate 3.1 is required for wetted parts.
27 NOTE 11: [Deleted]
28 Note 12: [Deleted]
29 Note 13: [Deleted]
30 Note 14: Motors shall be capable of starting under 80% nominal voltage at motor terminal box.
31 NOTE 15: Referred process data sheet is KHYCO-DD-000-PR-DSH-0016 Rev.00
32 Note 16: Performance curve shall be submitted and rated flow shall be within allowable operating region.
33 Note 17: Design pressure shall cover pump shutoff pressure plus maximum suction pressure.
34 Note 18: Pumping liquid is not flammable.
35 Note 19: Vibration values shall be recorded during the test.
36 Note 20: 3 mm CA is required for casing.
37 Note 21: Max allowable pressure at shut off shall not be exceed 1.2barg 02
Note 22: Specification for LV Motor is KHYCO-BD-000-EL-SPC-1011 .Datasheet for LV Motors KHYCO-DD-000-EL-DSH-0010, to be filled and be
02
38 provided by vendor
Note 23: For Instrument scope of work include selection of field instrument , Ingress Protection, Ex protection, power supply and etc., please
02
39 refer to "Technical Specification for Instrumentation and control for packages: KHYCO-DD-000-IN-SPC-0006".
40 Note 24: Design Temperature : -3.5 / 100 ͦC 02
41
42
43
44
45
46