SOLENOID VALVES

G75-O | Latch Operator 2 Way, 3 Way NC, NO G75-O | Latch Operator 2 Way, 3 Way NC, NO
Applicable for G75-A, GALIT, G75-S & G75-Z valves

Ø30
Dimensions
1/8" BSP/NPT

CABLE LENGTH
350 (mm)
BLACK/GREEN

58

47
SOLENOID ON
1.2
2WNC 3WNC/3WNO

9
2W Operator 3W Operator
3/4"-20 UNEF-2B
PLUNGER STROKE 1± 0.1

3WNC/3WNO 2WNC

Technical Data Working pressure (bar) 2W NC How to Order 3/4" 20TPI UNEF
Ø12
Function 2 Way, 3 Way NC, NO Latch Orifice (mm) up to 2.0 2W
2 Way : No orifice VOLTAGE
Pressure (bar) 12 G75-O - FUNCTION WIRES

2.2+0.1
Orifice size

5.5
6.5
3 Way : See table VDC (1)

10
Pressure range (bars) See solenoid valve performances 2W NC 1 4Ω B two null
• 4700µF for 9V DC
Working pressure (bar) 3W NC
Capacitors 9Ω C three a
• 2200µF for 12V DC Orifice (mm) 1.0 1.2 1.6
3W 12Ω D
Switching time 25-50 ms
AC Pressure (bar) 16 11 6
Fluid : 5ºC to 50ºC (no freezing) 23Ω 6
Temperature range G75-O - PORT FUNCTION ORIFICE Operator seat MaxØ2.0
Ambient : -10ºC to 50ºC
Housing: Working pressure (bar) 3W NO 1/8" BSP 10 3W NC 3 1.0 1
Reinforced Nylon 66
Orifice (mm) 1.0 1.2 1.6 1/8" NPT 11 3W NO 4 1.2 2
Plunger & pole:
Passivated Stainless Steel AISI 430F Pressure (bar) 16 12 10 1.6 3
Materials in contact Rubber Seals:
with media EPDM Coil resistance vs input voltage range
Encapsulate: Resistance [Ω] Suitable input voltage range [V]
Polyurethane
4 6-9
Spring:
Stainless Steel AISI 300 series 9 12 - 14
G1/8" or 1/8" NPT female to connect exhaust, 12 14 - 16
Threads on operator tube
muffler etc 23 18 - 21
One coil with exit of 2 lead wires. To pull the
Two wire operator plunger up, connect the black wire (-) and
the green to the (+). Example : G75-O-1-Ba
One coil and an integrated electrical circuit. G75 latch solenoid operator, 2W NC, 4Ω, 3 wires
To pull plunger up, pulse is given to the
Three wire operator red wire (-). To release the plunger, pulse is G75-O 1 B a
given to the black wire (-).
Operate only by a controller.
• Lead wires 35 cm, 18 AWG (0.75mm2) Example : G75-O-1042-Ca
Electrical connection (black/green)
G75 latch solenoid operator, 1/8" BSP, 3W NO, 1.2 orifice, 9Ω, 3 wires
• Lead wires : red, white, black for 3 wires G75-O 10 4 2 C a
Voltage 9, 12V DC (coils for other voltages available)
Standard protection class IP66 (1) Refer to coil resistance vs input voltage table
• Available with brass adaptor

* To order operators manufactured according to your specific requirements, please contact our technical sales department