0% found this document useful (0 votes)
53 views23 pages

Harmony XPS Basic and Universal Safety Modules With Predefined Safety Functions - February 2024

Uploaded by

Richy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
53 views23 pages

Harmony XPS Basic and Universal Safety Modules With Predefined Safety Functions - February 2024

Uploaded by

Richy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 23

Catalog | February 2024

Harmony XPS
Basic & Universal Safety Modules

www.se.com
Harmony
Discover Harmony
Advanced operator interface and industrial relays
Harmony operator interface and industrial relays enhance operational
efficiency and equipment availability across industrial and building
applications. Harmony includes intelligent connected products and edge
terminals that visualize, gather and process data, enabling informed
operator decisions

Explore our offer


- Harmony Push Buttons and Switches
- Harmony HMI Operator Terminals, IPC and EdgeBox
- Harmony Signaling Devices
- Harmony Electrical Relays
- Harmony Safety
Quick access to product information
Get technical information about your product

Each commercial reference presented in a catalog contains a hyperlink.


Click on it to obtain the technical information of the product:
– Characteristics, Dimensions and drawings, Mounting and clearance,
Connections and schemas, Performance curves
– Product image, Instruction sheet, User guide, Product certifications,
End of life manual

Find your catalog

• Up-to-date catalogs
> With just 3 clicks, you can access the Industrial Automation • Embedded product selectors,360° pictures
• Optimized search by commercial references
and Control catalogs, in both English and French
> Consult digital automation catalogs at Digi-Cat Online

Select your training

> Find the right Training for your needs on our Global website
> Locate the training center with the selector tool, using this link
General content

HarmonyTM XPS
Basic & Universal Safety Modules
Selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2
Selection of safety function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4

Basic Safety modules


b Type XPSBAC
- Operating principles.................................................................................. page 5
- Main features, references.......................................................................... page 5
b Type XPSBAT
- Operating principles.................................................................................. page 6
- Main features, references.......................................................................... page 6

Universal Safety modules


b Type XPSUAB
- Operating principles, selection.................................................................. page 7
- Main features, references.......................................................................... page 8
b Type XPSUAF
- Operating principles.................................................................................. page 9
- Main features, references.......................................................................... page 9
b Type XPSUAK
- Operating principles................................................................................ page 10
- Main features, references........................................................................ page 10
b Type XPSUAT
- Operating principles................................................................................ page 11
- Main features, references........................................................................ page 11
b Type XPSUDN
- Operating principles................................................................................ page 12
- Main features, references........................................................................ page 12
b Type XPSUS
- Operating principles, selection................................................................ page 13
- Main features, references........................................................................ page 14
b Type XPSUEP
- Operating principles................................................................................ page 15
- Main features, references........................................................................ page 15
b Type XPSUVN
- Operating principles................................................................................ page 16
- Main features, references........................................................................ page 16
b Accessories for Basic & Universal Safety Modules..................................... page 17
b Substitution table....................................................................................... page 18
b Product reference index............................................................................ page 20

1
Selection guide Harmony XPS
Basic & Universal Safety Modules

Safety module type Basic safety modules Universal safety modules


with pre-defined safety function with pre-defined safety function, or Selectable safety functions via rotary selectors
Safety functions

- Emergency stop - Emergency stop - Emergency stop - Emergency stop - Emergency stop - Emergency stop - Emergency stop - Emergency stop - For Extending the number - Zero speed monitoring
- Guard switch - Guard switch - Antivalent contact - Guard switch - Guard switch - Guard switch - Guard switch - Guard switch of safety contacts with delayed access to
- Magnetic switch - Guard switch - Magnetic switch - Magnetic switch - Magnetic switch - Magnetic switch - Magnetic switch dangerous area
- RFID safety switch - Magnetic switch - Proximity safety switch - Proximity safety switch - Proximity safety switch - Proximity safety switch - Proximity safety switch
- Safety light curtain - Proximity safety switch - PNP sensor - PNP & NPN sensor - PNP & NPN sensor - PNP sensor - PNP sensor
- PNP sensor - RFID safety switch - RFID safety switch - RFID safety switch - RFID safety switch - RFID safety switch
- RFID safety switch - Safety light curtain - Safety light curtain - Safety light curtain - Safety light curtain - Safety light curtain
- Safety light curtain - Sensing mat/edge - Sensing mat/edge - Two-hand control station
- Two-hand control station - Enabling switch

Maximum achievable safety level b PL e/Category 4 b PL c conforming to ISO 13849-1 b PL e/Category 4 b PL e/Category 3
conforming to ISO 13849-1 conforming to ISO 13849-1 conforming to ISO 13849-1
b SILC L 3 conforming to IEC 62061 b SILCL 1 conforming to IEC 62061 b SILC L 3 conforming to IEC 62061 b SILC L 3 conforming to
b SIL 3 conforming to IEC 61508 b SIL 1 conforming to IEC 61508 b SIL 3 conforming to IEC 61508 IEC 62061
b SIL 3 conforming to IEC
61508
Conformity to standards b IEC 60947-5-1
b IEC 61508-1 (functional safety standard)
b IEC 61508-2 (functional safety standard)
b IEC 61508-3 (functional safety standard)
b ISO 13849-1 (functional safety standard)
b IEC 62061 (functional safety standard)
Product certifications b cULus b cULus b cULus
b TÜV b TÜV b TÜV
b EAC b EAC b EAC
b CCC b CCC b CCC
b KC marking b KC marking b KC marking

Number of outputs Safety immediate 4 NO 2 NO 1 single changeover output 3 NO 2 NO + 1 NC 3 NO 3 NO + 1 NC 2 NO 4 NO -


Safety delayed - 1 NO (configurable) - - - 3 NO + 1 NC (configurable) - - - 1 NO (configurable)
(time delay) 0...900 s 0...900 s 0,5...60 s
Diagnostic 2 NC 1 solid state 1 pulsed solid state 1 pulsed solid state 1 pulsed solid state 1 pulsed solid state 1 pulsed solid state 1 pulsed solid state 2 NC 1 pulsed solid state
1 solid state 1 solid state
Display 5 LEDs 8 LEDs 6 LEDs 6 LEDs 6 LEDs 8 LEDs 16 LEDs 8 LEDs 3 LEDs 5 LEDs
Supply voltage 24 V AC/DC and 48-240 V 24 V AC/DC 24 V AC/DC and 48-240 V AC/DC
AC/DC
Synchronization time between inputs Fixed Fixed Selectable Selectable Selectable Selectable Selectable Selectable - Fixed
Number of inputs channels 2 2 2 2 2 3 12 4 - 3

Safety module type XPSBAC XPSBAT XPSUAB XPSUAF XPSUAK XPSUAT XPSUDN XPSUS XPSUEP XPSUVN
Page 5 6 7 9 10 11 12 13 15 16
Accessory type XPSEC, XPSES
Page 17 17

2 2
3
Presentation Harmony XPS
Basic safety modules
Safety functions: selection of safety modules

This selection table indicates which safety module to select, according to the
required safety functions.
Safety functions Safety modules

ISO 13849-1 PL c PL e/Category 3 PL e/Category 4


IEC 62061 SILCL 1 SILCL 3 SILC L 3
IEC 61508 SIL 1 SIL 3 SIL 3
Emergency stop Stop category 0 XPSUAB - XPSBAC
XPSUAF
XPSUAK
XPSUDN
XPSUS
Stop category 0+1 - - XPSBAT
XPSUAT

Control of access Interlocking guard with XPSUAB - XPSBAC


to hazardous zones and without guard XPSBAT
locking XPSUAF
XPSUAK
XPSUAT
XPSUDN
XPSUS
Magnetic switch XPSUAB - XPSBAT
XPSUAF
XPSUAK
XPSUAT
XPSUDN
XPSUS
RFID safety switch XPSUAB - XPSBAT
XPSUAF
XPSUAK
XPSUAT
XPSUDN
XPSUS
Light curtains XPSUAB - XPSBAT
XPSUAF
XPSUAK
XPSUAT
XPSUDN
XPSUS
Safety mats - - XPSUAK
XPSUAT

Starting and enabling of Two-hand control station XPSUAB - XPSUS


dangerous movements

Enabling switch - - XPSUS


(grip switch)

Proximity safety switch XPSUAB - XPSUAF


XPSUAK
XPSUAT
XPSUDN
XPSUS
Safety monitoring Zero speed detection - XPSUVN -
functions (remanent voltage)

Safety timer - XPSUVN -

Increasing the number of - - XPSUEP


safety contacts (1)

(1) More information in the page 16.

4
Operating principle, Harmony XPS
main features, Basic safety modules
references Type XPSBAC For E-stop and Guard switch

Operating principle
XPSBAC safety modules are used for monitoring Emergency stop circuits
conforming to standards EN/ISO 13850 and EN/IEC 60204-1 and also meet the
safety requirements for the electrical monitoring of switches in protective devices
conforming to standard EN/ISO 14119.
b They provide protection for both the machine operator and the machine by
immediately stopping the dangerous movement on receipt of a stop instruction
from the operator, or on detection of a fault in the safety circuit itself.
b XPSBAC module have 4 NO safety outputs and a serial or parallel hardwire
configurable NC output for signalling to the PLC.

- The safety functions are fixed.


- To aid diagnostics, XPSBAC modules have a serial or parallel hardwire
configurable NC output to provide information on the status of the zero speed
detection circuit.
- 5 LEDs on the front face provide information on the monitoring circuit status.
Main features
Start inputs Automatic, manual & monitored start
Safety inputs ˗
Control outputs 1
Safety outputs 4 NO
Diagnostic outputs 2 NC
Connection type Removable terminal blocks
Terminals 16
Module width 22.5 mm/0.886 in.
Maximum achievable safety b PL e/Category 4 conforming to ISO 13849-1
level b SILCL 3 conforming to IEC 62061
b SIL 3 conforming to IEC 61508
Product certifications b cULus
b TÜV
b EAC
b CCC
b KC marking
Conformity to standards b IEC 60947-5-1
b IEC 61508-1 (functional safety standard)
b IEC 61508-2 (functional safety standard)
b IEC 61508-3 (functional safety standard)
b ISO 13849-1 (functional safety standard)
b IEC 62061 (functional safety standard)

References
Description Voltage Terminals References Weight
mm/in. kg/lb
Type XPSBAC 24 V a/c Spring XPSBAC14AC 0.200
For monitoring E-stop and 5.08/0.20 0.440
Guard switch
Screw XPSBAC14AP 0.200
5.08/0.20 0.440

48-240 V a/c Spring XPSBAC34AC 0.200


5.08/0.20 0.440

Screw XPSBAC34AP 0.200


5.08/0.20 0.440
XPSBACp1AC XPBACp1AP

5
Operating principle, Harmony XPS
main features, Basic safety modules
references Type XPSBAT for monitoring Emergency stop, Guard switch, Magnetic
switch, RFID safety switch and Safety light curtain

Operating principle
XPSBAT safety modules are used for monitoring Emergency stop circuits
conforming to standards EN/ISO 13850 and EN/IEC 60204-1 and also meet the
safety requirements for the electrical monitoring of switches in protection devices
conforming to standard EN/ISO 14119.
b They provide protective for both the machine operator and the machine by
immediately stopping the dangerous movement on receipt of a stop instruction
from the operator, or on detection of a fault in the safety circuit itself.
b In addition to the stop category 0 instantaneous opening safety outputs, the
modules incorporate 1 stop category 1 time delay output which allows for controlled
deceleration of the motor components until a complete stop is achieved (for
example, motor braking by variable speed drive). At the end of the preset delay, the
supply is disconnected by opening the time delay output circuits.
b The time delay of the 3 output circuits is adjustable between 0 and 15 min (900 s),

- The safety functions and the time delay are selectable and can be configured by
selector switches on the front face, while the start function can be wiring configured.
- The Start button monitoring function is configurable depending on the wiring.
- 8 LEDs on the front face provide information on the monitoring circuit status, and
aid diagnostics.
Main features
Start inputs Automatic, manual & monitored start
Safety inputs 2
Control outputs 3
Safety outputs 2 NO immediate, 1 NO (configurable) 0...900 s
Diagnostic outputs 1
Connection type Removable terminal blocks
Terminals 16
Module width 22.5 mm/0.886 in.
Maximum achievable safety b PL e/Category 4 conforming to ISO 13849-1
level b SILCL 3 conforming to IEC 62061
b SIL 3 conforming to IEC 61508
Product certifications b cULus
b TÜV
b EAC
b CCC
b KC marking
Conformity to standards b IEC 60947-5-1
b IEC 61508-1 (functional safety standard)
b IEC 61508-2 (functional safety standard)
b IEC 61508-3 (functional safety standard)
b ISO 13849-1 (functional safety standard)
b IEC 62061 (functional safety standard)

References
Description Number of Setting Voltage Terminals References Weight
safety range of mm/in. kg/lb
circuits time delay
Type XPSBAT 3 NO 0…900 s 24 V a/c Spring XPSBAT12A1AC 0.200
for monitoring: (1 NO 5.08/0.20 0.440
- Emergency stop time
- Guard switch delay)
Screw XPSBAT12A1AP 0.200
- Magnetic switch
5.08/0.20 0.440
- RFID safety switch
- Safety light curtain

XPSBAT12A1AC XPSBAT12A1AP

6
Operating principle, Harmony XPS
selection Universal safety modules
Type XPSUAB, for monitoring Emergency stop, Antivalent contact, Guard
switch, Magnetic switch, Proximity safety switch, PNP sensor, RFID safety
switch, Safety light curtain or Two-hand control station

Operating principle
XPSUAB safety modules are designed to monitor two hand control stations IIIA
which must comply with International standard ISO 13851. The control stations must
be designed and installed so that they cannot be activated involuntarily or easily
rendered inoperative. Depending on the application, the requirements of type C
standards specific to the machinery involved must be met (additional personal
protection methods may have to be considered).
To initiate a dangerous movement, both operators (two-hand control pushbuttons)
must be activated within an interval of 0.5 s (synchronous activation). If one of the
two pushbuttons is released during a dangerous operation, the control sequence is
cancelled. Resuming the dangerous operation is possible only if both pushbuttons
are returned to their initial position and reactivated within the required time interval.
The safety distance between the control units and the hazardous zone must be
enough to ensure that when only one operator is released, the hazardous zone
cannot be reached before the dangerous movement has been completed or
stopped.
b With automatic, manual & monitored start, XPSUAB safety modules are used for
monitoring:
v A single contact Emergency stop conforming to standard ISO 13850
v Switches activated by protection devices conforming to standard ISO 14119:
- Antivalent contact pair
- Mechanical guard switch
- Magnetic switch with Antivalent contact
- Proximity safety switch with Antivalent contact
- PNP sensor
- RFID safety switch
v Type 4 light curtains conforming to IEC 61496-1 which have solid-state safety
outputs with test function
b With automatic start only, XPSUAB safety modules are used for monitoring
two-hand control IIIA.

- The safety functions and the start function are selectable and can be configured
by selector switches on the front face.
- A solid-state diagnostic output with complete status information facilitates
maintenance.
- 6 LEDs on the front face provide information on the monitoring circuit status, and
aid diagnostics.

Selection
Requirements of standard ISO 13851 Type I Type II Type III
A B C
Standard ISO 13851 defines the Use of both hands
selection of two-hand controls (simultaneous action)
according to its behavior.
Link between input and
This table details the 3 types of output signals
two-hand control conforming to
ISO 13851. Prevention of accidental
operation
For each type, it lists the
operating characteristics and Tamper-proof
minimum requirements.
Output signal reinitialised

Synchronous action
(specified time limit)
Use of proven components XPSUAB
(PLc, SIL1 conforming to
ISO 13849-1)
Redundancy with partial error XPSUS
detection (Category 3
conforming to ISO 13849-1)
Redundancy + Self- XPSUS
monitoring (Category 4
conforming to ISO 13849-1)

Conforming to ISO 13849-1 Conforming to ISO 13851

7
Main features, Harmony XPS
references Universal safety modules
Type XPSUAB, for monitoring Emergency stop, Antivalent contact, Guard
switch, Magnetic switch, Proximity safety switch, PNP sensor, RFID safety
switch, Safety light curtain or Two-hand control station

Main features
Start inputs Automatic, manual & monitored start
Safety input 1
Control outputs 2 ON/OFF configurable pulsed outputs
Safety outputs 1 single changeover output
Diagnostic outputs 1 solid state diagnostic output with complete status information
Connection type Removable terminal blocks
Safe expansion connection No
Terminals 16
Module width 22.5 mm/0.886 in.
Maximum achievable safety b PL c conforming to ISO 13849-1
level b SILCL 1 conforming to IEC 62061
b SIL 1 conforming to IEC 61508
Product certifications b cULus
b TÜV
b EAC
b CCC
b KC marking
Conformity to standards b IEC 60947-5-1
b IEC 61508-1 (functional safety standard)
b IEC 61508-2 (functional safety standard)
b IEC 61508-3 (functional safety standard)
b ISO 13849-1 (functional safety standard)
b IEC 62061 (functional safety standard)

References
Description Voltage Terminals References Weight
mm/in. kg/lb
Type XPSUAB 24 V a/c Spring XPSUAB11CC 0.200
for monitoring: 5.08/0.20 0.440
- Emergency stop
- Antivalent contact
- Guard switch
Screw XPSUAB11CP 0.200
- Magnetic switch
5.08/0.20 0.440
- Proximity safety switch
- PNP sensor
- RFID safety switch
- Safety light curtain 48-240 V a/c Spring XPSUAB31CC 0.200
- Two-hand control station 5.08/0.20 0.440

XPSUABp1CC XPSUABp1CP Screw XPSUAB31CP 0.200


5.08/0.20 0.440

8
Operating principle, Harmony XPS
main features, Universal safety modules
references Type XPSUAF, for monitoring Emergency stop, Guard switch, Magnetic
switch, Proximity safety switch, PNP sensor, RFID safety switch or Safety
light curtain

Operating principle
XPSUAF safety modules are used for providing protection for both the machine
operator and the machine by immediately stopping the dangerous movement on
receipt of a stop instruction from the operator or on detection of an issue in the
safety circuit itself.
XPSUAF safety modules are used for monitoring:
v Emergency stop circuits conforming to standard ISO 13850
v Switches activated by protection devices conforming to standard ISO 14119:
- Mechanical guard switches
- Magnetic switch with antivalent or 2 NC contacts
- Proximity safety switch with Antivalent contact
- PNP sensor
- RFID safety switch
v Type 4 light curtains conforming to IEC 61496-1 having solid-state safety outputs
with test function

- The safety functions and the start function are selectable and can be configured
by selector switches on the front face.
- A solid-state diagnostic output with complete status information facilitates
maintenance.
- To monitor a higher number of Antivalent contacts using this safety module, the
Antivalent contact can be connected with a NC in series and NO in parallel.
- 6 LEDs on the front face provide information on the monitoring circuit status, and
aid diagnostics.
Main features
Start inputs Automatic, manual & monitored start
Safety inputs 2
Control outputs 3 ON/OFF configurable pulsed outputs
Safety outputs 3 NO
Diagnostic outputs 1 solid state diagnostic output with complete status
information
Connection type Removable terminal blocks
Safe expansion connection Yes
Terminals 16
Module width 22.5 mm/0.886 in.
Maximum achievable safety b PL e/Category 4 conforming to ISO 13849-1
level b SILC L 3 conforming to IEC 62061
b SIL 3 conforming to IEC 61508
Product certifications b cULus
b TÜV
b EAC
b CCC
b KC marking
Conformity to standards b IEC 60947-5-1
b IEC 61508-1 (functional safety standard)
b IEC 61508-2 (functional safety standard)
b IEC 61508-3 (functional safety standard)
b ISO 13849-1 (functional safety standard)
b IEC 62061 (functional safety standard)

References
Description Voltage Terminals References Weight
mm/in. kg/lb
Type XPSUAF 24 V a/c Spring XPSUAF13AC 0.200
for monitoring: 5.08/0.20 0.440
- Emergency stop
- Guard switch Screw XPSUAF13AP 0.200
- Magnetic switch 5.08/0.20 0.440
- Proximity safety switch
- PNP sensor
- RFID safety switch 48-240 V a/c Spring XPSUAF33AC 0.200
- Safety light curtain 5.08/0.20 0.440

Screw XPSUAF33AP 0.200


5.08/0.20 0.440

XPSUAFp3AC XPSUAFp3AP

9
Operating principle, Harmony XPS
main features, Universal safety modules
references Type XPSUAK, for monitoring Emergency stop, Guard switch, Magnetic
switch, Proximity safety switch, PNP & NPN sensors, RFID safety switch,
Safety light curtain or Sensing mat/edge

Operating principle
XPSUAK safety modules provide protection for both the machine operator and the
machine by immediately stopping the dangerous movement on receipt of a stop
instruction from the operator or on detection of an issue in the safety circuit itself.
XPSUAK safety modules are used for monitoring:
v Emergency stop circuits conforming to standard ISO 13850
v Switches activated by protection devices conforming to standard ISO 14119:
- Mechanical guard switches
- Magnetic switch with antivalent or 2 NC contacts
- Proximity safety switch with Antivalent contact
- Sensor pair
- 1 PNP + 1 NPN sensor
- RFID safety switch
v Type 4 light curtains conforming to IEC 61496-1 having solid-state safety outputs
with test function
v 4-wire sensing mats or edges conforming to ISO 13856

- The safety functions and the start function are selectable and can be configured
by selector switches on the front face.
- A solid-state diagnostic output with complete status information facilitates
maintenance.
- To monitor a higher number of Antivalent contacts using this safety module, the
Antivalent contact can be connected with a NC in series and NO in parallel.
- 6 LEDs on the front face provide information on the monitoring circuit status, and
aid diagnostics.
Main features
Start inputs Automatic, manual & monitored start
Safety inputs 2
Control outputs 3 ON/OFF configurable pulsed outputs
Safety outputs 2 NO + 1 NC
Diagnostic outputs 1 solid state diagnostic output with complete status information
Connection type Removable terminal blocks
Safe expansion connection Yes
Terminals 20
Module width 22.5 mm/0.886 in.
Maximum achievable safety b PL e/Category 4 conforming to ISO 13849-1
level b SILC L 3 conforming to IEC 62061
b SIL 3 conforming to IEC 61508
Product certifications b cULus
b TÜV
b EAC
b CCC
b KC marking
Conformity to standards b IEC 60947-5-1
b IEC 61508-1 (functional safety standard)
b IEC 61508-2 (functional safety standard)
b IEC 61508-3 (functional safety standard)
b ISO 13849-1 (functional safety standard)
b IEC 62061 (functional safety standard)

References
Description Voltage Terminals References Weight
mm/in. kg/lb
Type XPSUAK 24 V a/c Spring XPSUAK12AC 0.200
for monitoring: 5.08/0.20 0.440
- Emergency stop
- Guard switch Screw XPSUAK12AP 0.200
- Magnetic switch 5.08/0.20 0.440
- Proximity safety switch
- PNP & NPN sensor
48-240 V a/c Spring XPSUAK32AC 0.200
- RFID safety switch
5.08/0.20 0.440
- Safety light curtain
- Sensing mat/edge
Screw XPSUAK32AP 0.200
5.08/0.20 0.440

XPSUAKp2AC XPSUAKp2AP

10
Operating principle, Harmony XPS
main features, Universal safety modules
references Type XPSUAT, for monitoring Emergency stop, Guard switch, Magnetic
switch, Proximity safety switch, PNP & NPN sensor, RFID safety switch,
Safety light curtain or Sensing mat/edge

Operating principle
XPSUAT safety modules provide protection for both the operator and the machine
by immediately stopping the dangerous movement on receipt of a stop instruction
from the operator, or on detection of an issue in the safety circuit itself.
XPSUAT safety modules are used for monitoring:
v Emergency stop circuits conforming to standard ISO 13850.
v Switches activated by protection devices conforming to standard ISO 14119:
- Mechanical guard switches
- Magnetic switch with antivalent or 2 NC contacts
- Proximity safety switch with Antivalent contact
- PNP Sensor
- 1 PNP + 1 NPN Sensor
- RFID safety switch
v Type 4 light curtains conforming to IEC 61496-1 having solid-state safety outputs
with test function.
v 4-wire sensing mats or edges conforming to ISO 13856.
v In addition to the stop category 0 instantaneous opening safety outputs, the
XPSUAT safety modules incorporate stop category 1 time delay outputs which
allow controlled deceleration of the motor to a complete stop (for example, motor
braking by variable speed drive). At the end of the preset delay, the supply is
disconnected by opening the time delayed output circuits. Also the time delay from 0 s
to 15 min (900 s) can be selected by selector switches on the front face.
- The safety functions and the start function are selectable and can be configured
by selector switches on the front face.
- A solid-state diagnostic output with complete status information facilitates
maintenance.
- To monitor a higher number of Antivalent contacts using this safety module, the
Antivalent contact can be connected with a NC in series and NO in parallel.
- 8 LEDs on the front face provide information on the monitoring circuit status, and
aid diagnostics.
Main features
Start inputs Automatic, manual & monitored start
Safety inputs 2 positive safety inputs 24 VDC, 1 negative safety input
Control outputs 4 ON/OFF configurable pulsed outputs
Safety outputs 3 NO immediate + 3 NO configurable + 1 NC configurable
Diagnostic outputs b 1 solid state diagnostic output for time delay ending
b 1 solid state diagnostic output with complete status information
Connection type Removable terminal blocks
Safe expansion Yes
connection
Terminals 27
Module width 45 mm/1.77 in.
Time delay setting 0 s to 15 min. The delay is configured with the delay base selector and
the delay factor selector
Maximum achievable b PL e/Category 4 conforming to ISO 13849-1
safety level b SILCL 3 conforming to IEC 62061
b SIL 3 conforming to IEC 61508
Product certifications b cULus
b TÜV
b EAC
b CCC
b KC marking
Conformity to standards b IEC 60947-5-1
b IEC 61508-1 (functional safety standard)
b IEC 61508-2 (functional safety standard)
b IEC 61508-3 (functional safety standard)
b ISO 13849-1 (functional safety standard)
b IEC 62061 (functional safety standard)
References
Description Setting range of Voltage Terminals References Weight
time delay mm/in. kg/lb
Type XPSUAT 0...900 s 24 V a/c Spring XPSUAT13A3AC 0.350
for monitoring 5.08/0.20 0.770
- Emergency stop
- Guard switch Screw XPSUAT13A3AP 0.350
- Magnetic switch 5.08/0.20 0.770
- Proximity safety
switch 48-240 V a/c Spring XPSUAT33A3AC 0.350
- PNP & NPN sensor 5.08/0.20 0.770
- RFID safety switch
- Safety light curtain Screw XPSUAT33A3AP 0.350
- Sensing mat/edge 5.08/0.20 0.770

XPSUATp3A3AC XPSUATp3A3AP

11
Operating principle, Harmony XPS
main features, Universal safety modules
references Type XPSUDN, for monitoring Emergency stop, Guard switch, Magnetic
switch, Proximity safety switch, PNP sensor, RFID safety switch or safety
light curtain

Operating principle
XPSUDN safety modules are used for monitoring:
v Emergency stop circuits conforming to standard ISO 13850
v Switches activated by protection devices conforming to standard ISO 14119:
- Mechanical guard switches
- Magnetic switch with antivalent or 2 NC contacts
- Proximity safety switch with Antivalent contact
- PNP Sensor
- RFID safety switch
v Type 4 light curtains conforming to IEC 61496-1 having solid-state safety outputs
with test function

- The safety functions and the start function are selectable and can be configured
by selector switches on the front face.
- A solid-state diagnostic output with complete status information facilitates
maintenance.
- To monitor a higher number of Antivalent contacts using this safety module, the
Antivalent contact can be connected with a NC in series and NO in parallel.
- 16 LEDs on the front face provide information on the monitoring circuit status,
and aid diagnostics.

Main features
Start inputs Automatic, manual & monitored start
Safety inputs 6
Control outputs 7 ON/OFF configurable pulsed outputs
Safety outputs 3 NO + 1 NC
Diagnostic outputs 1 solid-state diagnostic output with complete status information
Connection type Removable terminal blocks
Safe expansion connection Yes
Terminals 32
Module width 45 mm /1.77 in.
Maximum achievable safety b PL e/Category 4 conforming to ISO 13849-1
level b SILCL 3 conforming to IEC 62061
b SIL 3 conforming to IEC 61508
Product certifications b cULus
b TÜV
b EAC
b CCC
b KC marking
Conformity to standards b IEC 60947-5-1
b IEC 61508-1 (functional safety standard)
b IEC 61508-2 (functional safety standard)
b IEC 61508-3 (functional safety standard)
b ISO 13849-1 (functional safety standard)
b IEC 62061 (functional safety standard)

References
Description Voltage Terminals References Weight
mm/in. kg/lb
Type XPSUDN 24 V a/c Spring XPSUDN13AC 0.350
for monitoring 5.08/0.20 0.770
- Emergency stop
- Guard switch
- Magnetic switch Screw XPSUDN13AP 0.350
- Proximity safety switch 5.08/0.20 0.770
- PNP sensor
- RFID safety switch 48-240 V a/c Spring XPSUDN33AC 0.350
- Safety light curtain 5.08/0.20 0.770

Screw XPSUDN33AP 0.350


5.08/0.20 0.770

XPSUDNp3AC XPSUDNp3AP

12
Operating principle, Harmony XPS
selection Universal safety modules
Type XPSUS, for monitoring Emergency stop, Guard switch, Magnetic
switch, Proximity safety switch, PNP sensor, RFID safety switch, Safety
light curtain, Two-hand control station or Enabling switch

Operating principle
XPSUS safety modules are designed to monitor two hand control stations IIIA or IIIC
which must comply with International standard ISO 13851. The control stations must
be designed and installed so that they cannot be activated involuntarily or easily
rendered inoperative. Depending on the application, the requirements of type C
standards specific to the machinery involved must be met (additional personal
protection methods may have to be considered).
To initiate a dangerous movement, both operators (two-hand control pushbuttons)
must be activated within an interval of 0.5 s (synchronous activation). If one of the
two pushbuttons is released during a dangerous operation, the control sequence is
cancelled. Resuming the dangerous operation is possible only if both pushbuttons
are returned to their initial position and reactivated within the required time interval.
The safety distance between the control units and the hazardous zone must be
enough to ensure that when only one operator is released, the hazardous zone
cannot be reached before the dangerous movement has been completed or
stopped.
b With automatic, manual & monitored start, XPSUS safety modules are used for
monitoring:
v 2 Emergency stop circuits conforming to standard ISO 13850
v Switches activated by protection devices conforming to standard ISO 14119:
- 2 mechanical guard switches
- 2 magnetic switches with Antivalent contact or 2 NC contacts
- 2 proximity safety switches with Antivalent contact
- 2 independent PNP sensors
- 2 RFID safety switches
v Type 4 light curtains conforming to IEC 61496-1 having solid-state safety outputs
with test function
b With automatic start only, XPSUS safety modules are used for monitoring one
two-hand control IIIA, IIIC or enabling switch.

- The safety functions and the start function are selectable and can be configured
by selector switches on the front face.
- A solid-state diagnostic output with complete status information facilitates
maintenance.
- To monitor a higher number of Antivalent contacts using these safety modules,
the Antivalent contact can be connected with a NC in series and NO in parallel.
- 8 LEDs on the front face provide information on the monitoring circuit status, and
aid diagnostics.
Selection
Requirements of standard ISO 13851 Type I Type II Type III
A B C
Standard ISO 13851 defines the Use of both hands (simultaneous action)
selection of two-hand controls
according to its behavior. Link between input and output signals
This table details the 3 types of
two-hand control conforming to Prevention of accidental operation
ISO 13851.
For each type, it lists the Tamper-proof
operating characteristics and
minimum requirements. Output signal reinitialised

Synchronous action (specified time limit)

Use of proven components XPSUAB


(PLc, SIL1 conforming to ISO 13849-1)
Redundancy with partial error detection XPSUS
(Category 3 conforming to ISO 13849-1)
Redundancy + Self-monitoring (Category 4 XPSUS
conforming to ISO 13849-1)

Conforming to ISO 13849-1 Conforming to ISO 13851

13
Main features, Harmony XPS
references Universal safety modules
Type XPSUS, for monitoring Emergency stop, Guard switch, Magnetic
switch, Proximity safety switch, PNP sensor, RFID safety switch, Safety
light curtain,Two-hand control station or Enabling switch

Main features
Start inputs Automatic, manual & monitored start
Safety inputs 2
Control outputs 3 ON/OFF configurable pulsed outputs
Safety outputs 2 NO
Diagnostic outputs 1 solid-state diagnostic output with complete status information
Connection type Removable terminal blocks
Safe expansion connection Yes
Terminals 16
Module width 22.5 mm/0.886 in.
Maximum achievable safety b PL e/Category 4 conforming to ISO 13849-1
level b SILCL 3 conforming to IEC 62061
b SIL 3 conforming to IEC 61508
Product certifications b cULus
b TÜV
b EAC
b CCC
b KC marking
Conformity to standards b IEC 60947-5-1
b IEC 61508-1 (functional safety standard)
b IEC 61508-2 (functional safety standard)
b IEC 61508-3 (functional safety standard)
b ISO 13849-1 (functional safety standard)
b IEC 62061 (functional safety standard)

References
Description Voltage Terminals References Weight
mm/in. kg/lb
Type XPSUS 24 V a/c Spring XPSUS12AC 0.200
for monitoring: 5.08/0.20 0.440
- Emergency stop
- Guard switch
- Magnetic switch Screw XPSUS12AP 0.200
- Proximity safety switch 5.08/0.20 0.440
- PNP sensor
- RFID safety switch
- Safety light curtain
- Two-hand control station 48-240 V a/c Spring XPSUS32AC 0.200
- Enabling switch 5.08/0.20 0.440

Screw XPSUS32AP 0.200


XPSUSp2AC XPSUSp2AP 5.08/0.20 0.440

14
Operating principle, Harmony XPS
main features, Universal safety modules
references Type XPSUEP, for Extending the number of safety contacts

Operating principle
XPSUEP safety modules are used for extending the number of safety output contacts
of XPS Universal safety modules.
XPSUEP are available as additions to base modules (Emergency stop, limit switch,
two-hand control, etc.).
XPSUEP can be only used with XPSUAF, XPSUAK, XPSUAT, XPSUDN, XPSUVN
and XPSUS safety modules. When XPSUAT is the base module for instance, its
con iguration is used to choose whether the XPSUEP's outputs follow XPSUAT’s
immediate or time delayed outputs.

- 3 LEDs on the front face provide information on the monitoring circuit status, and
aid diagnostics.

Main features
Start input Follows the host module
Safety inputs 0, Extension bus
Safety outputs 4 NO + 2 single NC
Connection Connection to base module by connector
Diagnostic outputs 1 solid-state diagnostic output with complete status information
Connection type Removable terminal blocks
Terminals 16
Module width 22.5 mm/0.886 in.
Maximum achievable b PL e/Category 4 conforming to ISO 13849-1
safety level b SILCL 3 conforming to IEC 62061
b SIL 3 conforming to IEC 61508
Product certifications b cULus
b TÜV
b EAC
b CCC
b KC marking
Conformity to b IEC 60947-5-1
standards b IEC 61508-1 (functional safety standard)
b IEC 61508-2 (functional safety standard)
b IEC 61508-3 (functional safety standard)
b ISO 13849-1 (functional safety standard)
b IEC 62061 (functional safety standard)

References
Description Compatible Voltage Terminals References Weight
with mm/in. kg/lb
Type XPSUEP XPSUAF 24 V a/c Spring XPSUEP14AC 0.200
For Extending the XPSUAK 5.08/0.20 0.440
number of safety XPSUAT
contacts XPSUDN
Screw XPSUEP14AP 0.200
XPSUS
5.08/0.20 0.440
XPSUVN

48-240 V Spring XPSUEP34AC 0.200


a/c 5.08/0.20 0.440

Screw XPSUEP34AP 0.200


5.08/0.20 0.440
XPSUEPp4AC XPSUEPp4AP

15
Operating principle, Harmony XPS
main features, Universal safety modules
references Type XPSUVN, for Zero speed monitoring with delayed access to
dangerous area

Operating principle
XPSUVN is a safety module for interruption of safety-related electrical circuits.
XPSUVN provides for sensorless standstill monitoring of a motor, and measures the
residual voltage that is generated by remanent magnetization after power to the
motor is removed and while it coasts down. The voltage is measured via an analog
voltage measuring input to determine when standstill has actually been reached.
This can be used to implement a safety related function such as controlling an
interlocking device with guard locking.
The following types of motors which generate a measurable residual voltage when
coasting down after power supply has been removed can be connected to the
safety-related input of the device:
v Three-phase AC motors
v Single-phase AC motors
v DC motors
v Three-phase AC motors with star-delta wiring
XPSUVN safety module can monitor motors that are operated via mains as well as
motors that are controlled by electronic motor control equipment such as frequency
inverters.
In addition, XPSUVN safety module uses an adjustable activation delay. The
activation delay is the period between the point in time at which the measured
voltage drops below the adjusted voltage threshold and the point in time at which
activation of the safety-related outputs is triggered;

- The Voltage threshold and the Activation delay can be configured by selector
switches on front face.
- To aid diagnostics, XPSUVN modules have 2 solid-state outputs to provide
information on the status of the zero speed detection circuit
- 5 LEDs on the front face provide information on the monitoring circuit status, and
aid diagnostics.
Main features
Start input Automatic
Safety inputs 3
Control outputs ˗
Safety outputs 1 NO (configurable) 0,5...60 s
Diagnostic outputs 2
Connection type Removable terminal blocks
Safe expansion connection Yes
Terminals 16
Module width 22.5 mm/0.886 in.
Time delay setting 0.5 s, 1 s, 2 s, 3 s, 5 s, 8 s, 12 s, 20 s, 35 s, 60 s
Voltage threshold selector: 50...500 mV
Maximum achievable safety level b PL e/Category 3 conforming to ISO 13849-1
b SILCL 3 conforming to IEC 62061
b SIL 3 conforming to IEC 61508
Product certifications b cULus
b TÜV
b EAC
b CCC
b KC marking
Conformity to standards b IEC 60947-5-1
b IEC 61508-1 (functional safety standard)
b IEC 61508-2 (functional safety standard)
b IEC 61508-3 (functional safety standard)
b ISO 13849-1 (functional safety standard)
b IEC 62061 (functional safety standard)

References
Description Setting range of Voltage Terminals References Weight
time delay mm/in. kg/lb
Type XPSUVN 0.5...60 s 24 V a/c Spring XPSUVN11AC 0.200
For zero speed 5.08/0.20 0.440
monitoring with
delayed access Screw XPSUVN11AP 0.200
to dangerous 5.08/0.20 0.440
area 48-240 V a/c Spring XPSUVN31AC 0.200
5.08/0.20 0.440
Screw XPSUVN31AP 0.200
XPSUVNp1AC XPSUVNp1AP 5.08/0.20 0.440

16
Presentation, Harmony XPS
references Basic & Universal Safety Modules
Accessories

Presentation
XPSEC is a set of plastic coding elements for terminal blocks

References
Description Use for Unit reference Weight
kg/lb
Terminal block coding bit XPS Basic & Universal Safety XPSEC 0.010/
Modules Sold in lot of 30 0.020

XPSEC

Presentation
XPSES is a set of uniquely numbered sealing strips used to seal the transparent
front cover flap of any XPS Universal and Basic safety module to prevent operator or
maintenance to change the configuration.

References
Description Use for Unit reference Weight
kg/lb
Sealing strips XPS Basic & Universal Safety XPSES 0.030/
Modules Sold in lot of 10 0.066

XPSES

17
References Harmony XPS
Basic & Universal Safety Modules
Substitution table

Preventa XPS Safety modules (end of commercialization) Harmony XPS Basic safety modules (new)
Reference Reference Comment Additional comment
XPSABV11330C 1.5…30 sec delay, only XPSBAT12A1AC - Direct replacement 0…900 sec delay
potential free inputs
XPSABV11330P XPSBAT12A1AP - Direct replacement

XPSABV1133C 0.15…3 sec delay, only XPSBAT12A1AC - Direct replacement


potential free inputs
XPSABV1133P XPSBAT12A1AP - Direct replacement
XPSAC1321 3 NO output XPSBAC34AP - Direct replacement 4 NO + 2 NC output
XPSAC1321P 3 NO output XPSBAC34AP - Direct replacement
XPSAC3421 3 NO output XPSBAC34AP - Direct replacement
XPSAC3421P 3 NO output XPSBAC34AP - Direct replacement
XPSAC3721 3 NO output XPSBAC34AP - Direct replacement
XPSAC3721P 3 NO output XPSBAC34AP - Direct replacement
XPSAC5121 3 NO output XPSBAC14AP - Direct replacement
XPSAC5121P 3 NO output XPSBAC14AP - Direct replacement

XPSAXE5120C 3 NO + 1 NC output XPSBAC14AC - Direct replacement


XPSAXE5120P 3 NO + 1 NC output XPSBAC14AP - Direct replacement

XPSAFL5130 - XPSUAF13AP - Direct replacement -


XPSAFL5130P - XPSUAF13AP - Direct replacement -
XPSAK311144 - XPSUAK12AP - Direct replacement XPSUAK have 1 NO less than XPSAK
XPSAK311144P - XPSUAK12AP - Direct replacement XPSUAK have 1 NO less than XPSAK
XPSAK331144P - XPSUAK32AP - Direct replacement XPSUAK have 1 NO less than XPSAK
XPSAK351144 - XPSUAK32AP - Direct replacement XPSUAK have 1 NO less than XPSAK
XPSAK351144P - XPSUAK32AP - Direct replacement XPSUAK have 1 NO less than XPSAK
XPSAK361144 - XPSUAK32AP - Direct replacement XPSUAK have 1 NO less than XPSAK
XPSAK361144P - XPSUAK32AP - Direct replacement XPSUAK have 1 NO less than XPSAK
XPSAK371144 - XPSUAK32AP - Direct replacement XPSUAK have 1 NO less than XPSAK
XPSAK371144P - XPSUAK32AP - Direct replacement XPSUAK have 1 NO less than XPSAK
XPSAR311144 Global group 1 XPSUAT13A3AP 1 OR If max. 6 NO are used
XPSAR311144 Global group 1 XPSUAF13AP 1 AND If all 7 NO are used
XPSAR311144 Global group 1 XPSUEP14AP 1
XPSAR311144P Global group 2 XPSUAT13A3AP 2 OR If max. 6 NO are used
XPSAR311144P Global group 2 XPSUAF13AP 2 AND If all 7 NO are used
XPSAR311144P Global group 2 XPSUEP14AP 2
XPSAR351144 Global group 3 XPSUAT33A3AP 3 OR If max. 6 NO are used
XPSAR351144 Global group 3 XPSUAF33AP 3 AND If all 7 NO are used
XPSAR351144 Global group 3 XPSUEP14AP 3
XPSAR351144P Global group 4 XPSUAT33A3AP 4 OR If max. 6 NO are used
XPSAR351144P Global group 4 XPSUAF33AP 4 AND If all 7 NO are used
XPSAR351144P Global group 4 XPSUEP14AP 4

XPSAR371144 Global group 5 XPSUAT33A3AP 5 OR If max. 6 NO are used


XPSAR371144 Global group 5 XPSUAF33AP 5 AND If all 7 NO are used
XPSAR371144 Global group 5 XPSUEP14AP 5
XPSAR371144P Global group 6 XPSUAT33A3AP 6 OR If max. 6 NO are used
XPSAR371144P Global group 6 XPSUAF33AP 6 AND If all 7 NO are used

XPSAR371144P Global group 6 XPSUEP14AP 6

18
References Harmony XPS
Universal Safety Modules
Substitution table (Continued)

Preventa XPS Safety modules (end of commercialization) Harmony XPS Universal safety modules (new)
Reference Reference Group Comment Additional comment
XPSATE3410 XPSUAT33A3AP - Direct replacement -
XPSATE3410P XPSUAT33A3AP - Direct replacement -
XPSATE3710 XPSUAT33A3AP - Direct replacement -
XPSATE3710P XPSUAT33A3AP - Direct replacement -
XPSATE5110 XPSUAT13A3AP - Direct replacement -
XPSATE5110P XPSUAT13A3AP - Direct replacement -
XPSATR11530C XPSUAT13A3AC - Direct replacement -
XPSATR11530P XPSUAT13A3AP - Direct replacement -
XPSATR1153C XPSUAT13A3AC - Direct replacement -
XPSATR1153P XPSUAT13A3AP - Direct replacement -
XPSATR39530C XPSUAT33A3AC - Direct replacement -
XPSATR39530P XPSUAT33A3AP - Direct replacement -
XPSATR3953C XPSUAT33A3AC - Direct replacement -
XPSATR3953P XPSUAT33A3AP - Direct replacement -
XPSAV11113 XPSUAT13A3AP - Direct replacement -
XPSAV11113P XPSUAT13A3AP - Direct replacement -
XPSAV11113T050 XPSUAT13A3AP - Direct replacement -
XPSAV11113Z002 XPSUAT13A3AP - Direct replacement -
XPSBAE3920C XPSUAB31CC (1) - Direct replacement -
XPSBAE3920P XPSUAB31CP(1) - Direct replacement -
XPSBAE5120C XPSUAB11CC (1) - Direct replacement -
XPSBAE5120P XPSUAB11CP (1) - Direct replacement -
XPSBCE3110C XPSUS12AC - Direct replacement -
XPSBCE3110P XPSUS12AP - Direct replacement -
XPSBCE3410C XPSUS32AC - Direct replacement -
XPSBCE3410P XPSUS32AP - Direct replacement -
XPSBCE3710C XPSUS32AC - Direct replacement -
XPSBCE3710P XPSUS32AP - Direct replacement -
XPSBF1132 XPSUS12AP - Direct replacement -
XPSBF1132P XPSUS12AP - Direct replacement -
XPSDMB1132 XPSUS12AP - Direct replacement -
XPSDMB1132P XPSUS12AP - Direct replacement -
XPSDME1132 XPSUDN13AP - Direct replacement -
XPSDME1132P XPSUDN13AP - Direct replacement -
XPSDME1132TS220 XPSUDN13AP - Direct replacement -
XPSECME5120C XPSUEP14AC - Indirect replacement Only in combination with XPSU host
XPSECME5120P XPSUEP14AP - Indirect replacement Only in combination with XPSU host
XPSECME5131C XPSUEP14AC - Indirect replacement Only in combination with XPSU host
XPSECME5131P XPSUEP14AP - Indirect replacement Only in combination with XPSU host
XPSVC1132 XPSUS12AP - Direct replacement -
XPSVC1132P XPSUS12AP - Direct replacement -
XPSVNE1142HSP No time delay included (must be XPSUVN11AP - Time delay included + 2 variants
implemented with another for different supply voltages, no
XPSVNE1142LFP device) XPSUVN11AP - variants for different frequency
XPSVNE1142P + 3 variants for different supply XPSUVN11AP - ranges
voltages
XPSVNE3442HSP + 3 variants for different XPSUVN31AP -
frequency ranges
XPSVNE3442LFP XPSUVN31AP -
XPSVNE3442P XPSUVN31AP -
XPSVNE3742HSP XPSUVN31AP -
XPSVNE3742P XPSUVN31AP -

(1) Suitable for PLc according to ISO 13849-1.

19
Index Harmony XPS
Basic & Universal Safety Modules
Product reference index

X XPSBAT12A1AP 6 XPSUS32AP 14
XPSABV1133C 18 18 19
XPSABV1133P 18 XPSBCE3110C 19 XPSUVN11AC 16
XPSABV11330C 18 XPSBCE3110P 19 XPSUVN11AP 16
XPSBCE3410C 19 19
XPSABV11330P 18
XPSBCE3410P 19 XPSUVN31AC 16
XPSAC1321 18
XPSBCE3710C 19 XPSUVN31AP 16
XPSAC1321P 18 19
XPSAC3421 18 XPSBCE3710P 19
XPSVC1132 19
XPSAC3421P 18 XPSBF1132 19
XPSVC1132P 19
XPSAC3721 18 XPSBF1132P 19
XPSVNE1142HSP 19
XPSAC3721P 18 XPSDMB1132 19
XPSVNE1142LFP 19
XPSAC5121 18 XPSDMB1132P 19
XPSVNE1142P 19
XPSAC5121P 18 XPSDME1132 19
XPSVNE3442HSP 19
XPSAFL5130 18 XPSDME1132P 19
XPSVNE3442LFP 19
XPSAFL5130P 18 XPSDME1132TS220 19
XPSVNE3442P 19
XPSAK311144 18 XPSEC 17
XPSVNE3742HSP 19
XPSAK311144P 18 XPSECME5120C 19
XPSVNE3742P 19
XPSAK331144P 18 XPSECME5120P 19
XPSAK351144 18 XPSECME5131C 19
XPSAK351144P 18 XPSECME5131P 19
XPSAK361144 18 XPSES 17
XPSAK361144P 18 XPSUAB11CC 8
19
XPSAK371144 18
XPSUAB11CP 8
XPSAK371144P 18 19
XPSAR311144 18 XPSUAB31CC 8
XPSAR311144P 18 19
XPSAR351144 18 XPSUAB31CP 8
XPSAR351144P 18 19
XPSAR371144 18 XPSUAF13AC 9
XPSAR371144P 18 XPSUAF13AP 9
18
XPSATE3410 19
XPSUAF33AC 9
XPSATE3410P 19
XPSUAF33AP 9
XPSATE3710 19 18
XPSATE3710P 19 XPSUAK12AC 10
XPSATE5110 19 XPSUAK12AP 10
XPSATE5110P 19 18
XPSATR1153C 19 XPSUAK32AC 10
XPSATR1153P 19 XPSUAK32AP 10
XPSATR3953C 19 18
XPSATR3953P 19 XPSUAT13A3AC 11
19
XPSATR11530C 19
XPSUAT13A3AP 11
XPSATR11530P 19 18
XPSATR39530C 19 19
XPSATR39530P 19 XPSUAT33A3AC 11
XPSAV11113 19 19

XPSAV11113P 19 XPSUAT33A3AP 11
18
XPSAV11113T050 19 19
XPSAV11113Z002 19 XPSUDN13AC 12
XPSAXE5120C 18 XPSUDN13AP 12
XPSAXE5120P 18 19
XPSBAC14AC 5 XPSUDN33AC 12
18 XPSUDN33AP 12
XPSBAC14AP 5 XPSUEP14AC 15
18 19
XPSBAC34AC 5 XPSUEP14AP 15
XPSBAC34AP 5 18
18 19
XPSBAE3920C 19 XPSUEP34AC 15
XPSBAE3920P 19 XPSUEP34AP 15
XPSBAE5120C 19 XPSUS12AC 14
19
XPSBAE5120P 19
XPSUS12AP 14
XPSBAT12A1AC 6
19
18
XPSUS32AC 14
19

20
Learn more about our products at
www.se.com

The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the
products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability
of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk
analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric
nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.

Design: Schneider Electric


Photos: Schneider Electric

Schneider Electric Industries SAS


Head Office
35, rue Joseph Monier - CS 30323
F-92500 Rueil-Malmaison Cedex
France

DIA3ED2181204EN
February 2024 - V3.3

You might also like