TEMPORARY ACCESS SUMMARY DETAILS

Descriptions
Drawing
Supporting Block/ Man-
S.No. Details
Documents Compartment Fr./Long'l/ TS No Job scope
Hours
Remarks Material Specification Quantity
No. (Lump
sum)
PL-5000 x 2600 x 12 1
AL-2600 x 75/100 x 6 8
T-Bar W/PL-2600 x 1100 x 10 1
F/PL-2600 x 350 x 16 1
T-Bar W/PL-1350 x 450 x 8 1
F/PL-1350 x 150 x 8 1
Supply skilled manpower, tools, PPE & equipment to crop off
FWD-STBD THRUSTER VFD existing steel/remove and reinstall FWD STBD Thruster VFD room T-Bar W/PL-3640 x 350 x 8 1
ROOM Fr 4 to 6 EL due to interference for equipment installatiion and QC/QA/Owner
1 H200-233-001-02, R3 2 18500 Access opened F/PL-3640 x 100 x 8 1
(MAIN DECK) inspection was carried out at erection stage. sketch and as BKT-635 x 300 x 10 1
instructed by the yard/ owner's representatives.
BKT-Stif-570 x 100 x 10 1
BKT-742 x 350 x 10 1
BKT-Stiff-680 x 100 x 10 1
AL-1050 x 75/100 x 6 1
AL-1410 x 75/100 x 6 1
BKT-250 x 250 x 8 1
PL-5000 x 2600 x 12 1
AL-2600 x 75/100 x 6 8
T-Bar W/PL-2600 x 1100 x 10 1
F/PL-2600 x 350 x 16 1
T-Bar W/PL-1350 x 450 x 8 1
F/PL-1350 x 150 x 8 1
Supply skilled manpower, tools, PPE & equipment to crop off
FWD-STBD THRUSTER VFD existing steel/remove and reinstall FWD STBD Thruster VFD room T-Bar W/PL-3640 x 350 x 8 1
ROOM Fr 4 to 6 EL due to interference for equipment installatiion and QC/QA/Owner
2 H200-233-001-02, R3 4 18500 Access opened F/PL-3640 x 100 x 8 1
(MAIN DECK) inspection was carried out at erection stage. sketch and as BKT-635 x 300 x 10 1
instructed by the yard/ owner's representatives.
BKT-Stif-570 x 100 x 10 1
BKT-742 x 350 x 10 1
BKT-Stiff-680 x 100 x 10 1
AL-1050 x 75/100 x 6 1
AL-1410 x 75/100 x 6 1
BKT-250 x 250 x 8 1

PL-3790 x 3150 x 6 1
Supply skilled manpower, tools, PPE & equipment to crop off AL-3790 x 75/100 x 6 6
FWD-FUNNEL Fr 19 to 21 existing steel/remove and reinstall FWD Funnel (Roof top) due to Visual done T-Bar W/PL-3150 x 500 x 8 1
3 H950-268-000-01, R0 5 interference for equipment installatiion and QC/QA/Owner (NDT Balance)
(ROOF TOP) EL 41795 inspection was carried out at erection stage. sketch and as T-Bar F/PL-3150 x 150 x 8 1
instructed by the yard/ owner's representatives. BKT-400 x 250 x 10 1

PL-2500 x 1500 x 16 1
PL-2500 x 1500 x 10 1
Supply skilled manpower, tools, PPE & equipment to crop off
Fr 38 to 39 existing steel/remove and reinstall Main deck,LG-BHD and PL-2400 x 1400 x 8 1
MAIN DECK AND EL16500 Cofferdam deck (Transformer room) due to interference for JOB AL-1500 x 75/100 x 6 3
4 H200-233-001-02, R3 COFFERDAM DECK 9 Completed
TO equipment installatiion and QC/QA/Owner inspection was carried AL-1500 x 90/150 x 12 1
(Transformer Room) EL 18500 out at erection stage. sketch and as instructed by the yard/ owner's AL-1400 x 75/100 x 6 7
representatives.

Supply skilled manpower, tools, PPE & equipment to crop off


Fr 41 to 43 EL existing
steel/remove and reinstall AFT Funnel (Roof top) due to JOB PL-2700 x 2500 x 6 1
AFT-FUNNEL interference for equipment installatiion and QC/QA/Owner Completed
5 H950-268-002-01, R3 (ROOF TOP) 10 41795 inspection was carried out at erection stage. sketch and as AL-2700 x 75/100 x 6 5
instructed by the yard/ owner's representatives.

Supply skilled manpower, tools, PPE & equipment to crop off


AFT-PORT THRUSTER VFD existing steel/remove and reinstall AFT PORT Thruster VFD room Visual done PL-6000 X 1200 X 25 1
Fr 54 to 55 EL due
6 H200-233-001-02, R3 ROOM 12 to interference for equipment installatiion and QC/QA/Owner (NDT Balance)
18500 AL-1200 x 75/150 x 7 11
(MAIN DECK) inspection was carried out at erection stage. sketch and as
instructed by the yard/ owner's representatives.

PL-4600 x 3610 x 25 1
AL-3610 x 75/150 x 7 8
AL-830 x 75/100 x 6 2
Supply skilled manpower, tools, PPE & equipment to crop off AL-2650 x 75/100 x 6 2
AFT-PORT THRUSTER ROOM existing steel/remove and reinstall AFT PORT Thruster room due to AL-880 x 75/100 x 6 2
Fr 56 to 58 EL interference for equipment installatiion and QC/QA/Owner
7 H200-233-001-02, R3 13 18500 Access opened
(MAIN DECK) inspection was carried out at erection stage. sketch and as T-Bar W/PL-4600 x 1045 x 10 2
instructed by the yard/ owner's representatives. T-Bar F/PL-4600 x 350 x 16 2
BKT-300 x 160 x 10 6
BKT-900 x 410 x 10 4
PL-840 x 100 x 10 4

PL-3600 x 2280 x 12 1
Supply skilled manpower, tools, PPE & equipment to crop off T-Bar W/PL-2280 x 650 x 10 1
AFT-PORT THRUSTER VDF existing steel/remove and reinstall AFT PORT Thruster VDF room T-Bar F/PL-2280 x 150 x 16 1
Fr 60 to 62 EL due
8 H200-233-001-02, R3 ROOM 14 to interference for equipment installatiion and QC/QA/Owner Access opened
18500 BKT-500 x 250 x 10 1
(MAIN DECK) inspection was carried out at erection stage. sketch and as
instructed by the yard/ owner's representatives. PL-420 x 100 x 10 1
AL-3600 x 75/150 x 7 4

PL-4500 x 2800 x 25 1
Supply skilled manpower, tools, PPE & equipment to crop off AL-4500 x 75/100 x 6 5
AFT-PORT THRUSTER VDF existing steel/remove and reinstall AFT PORT Thruster VDF room T-Bar W/PL-2800 x 800 x 12 1
Fr 55 to 57 EL due
9 H200-233-001-02, R3 ROOM 15 to interference for equipment installatiion and QC/QA/Owner Access opened
18500 T-Bar F/PL-2800 x 200 x 16 1
(MAIN DECK) inspection was carried out at erection stage. sketch and as
instructed by the yard/ owner's representatives. BKT-800 x 300 x 10 1
PL-600 x 100 x 10 1

PL-4500 x 2700 x 25 1
Supply skilled manpower, tools, PPE & equipment to crop off T-Bar W/PL-2700 x 800 x 12 1
AFT-STBD THRUSTER VDF existing steel/remove and reinstall AFT STBD Thruster VDF room Visual done T-Bar F/PL-2700 x 200 x 16 1
Fr 55 to 57 EL due
10 H200-233-001-02, R3 ROOM 16 to interference for equipment installatiion and QC/QA/Owner (NDT Balance)
18500 AL-4500 x 75/150 x 7 5
(MAIN DECK) inspection was carried out at erection stage. sketch and as
instructed by the yard/ owner's representatives. BKT-650 x 300 x 10 1
PL-600 x 100 x 10 1

Supply skilled manpower, tools, PPE & equipment to crop off PL-6000 X 1200 X 25 1
AFT-STBD THRUSTER VDF existing steel/remove and reinstall AFT STBD Thruster VDF room Visual done AL-1200 x 75/150 x 7 10
Fr 54 to 55 EL due
11 H200-233-001-02, R3 ROOM 17 to interference for equipment installatiion and QC/QA/Owner (NDT Balance)
18500
(MAIN DECK) inspection was carried out at erection stage. sketch and as
instructed by the yard/ owner's representatives.
Supply skilled manpower, tools, PPE & equipment to crop off
AFT-STBD THRUSTER VDF existing steel/remove and reinstall AFT STBD Thruster VDF room Visual done
Fr 54 to 55 EL
11 H200-233-001-02, R3 ROOM 17 18500 due to interference for equipment installatiion and QC/QA/Owner (NDT Balance)
(MAIN DECK) inspection was carried out at erection stage. sketch and as
instructed by the yard/ owner's representatives.
PL-4500 x 3200 x 25 1
AL-4500 x 75/150 x 7 6
Supply skilled manpower, tools, PPE & equipment to crop off T-Bar W/PL-3200 x 1045 x 10 2
AFT-STBD THRUSTER ROOM Fr 56 to 58 EL existing steel/remove and reinstall AFT STBD Thruster room due to Access opened T-Bar F/PL-3200 x 400 x 16 2
12 H200-233-001-02, R3 18 18500 interference for equipment installatiion and QC/QA/Owner (Temporary
(MAIN DECK) inspection was carried out at erection stage. sketch and as closed) AL-2650 x 75/100 x 6 2
instructed by the yard/ owner's representatives. BKT-900 x 410 x 10 4
PL-840 x 100 x 10 4
AL-4550 x 75/100 x 6 (Loose piece) 4

PL-3600 x 2300 x 12 1
Supply skilled manpower, tools, PPE & equipment to crop off T-Bar W/PL-2300 x 650 x 10 1
AFT-STBD THRUSTER VDF Fr 59 to 61 EL existing steel/remove and reinstall AFT STBD Thruster VDF room T-Bar F/PL-2300 x 150 x 16 1
13 H200-233-001-02, R3 ROOM 19 18500 due to interference for equipment installatiion and QC/QA/Owner Access opened
(MAIN DECK) inspection was carried out at erection stage. sketch and as BKT-500 x 250 x 10 1
instructed by the yard/ owner's representatives. PL-420 x 100 x 10 1
AL-3600 x 75/150 x 7 4

PL-3900 x 2300 x 12 1
T-Bar W/PL-3900 x 640 x 10 1
Supply skilled manpower, tools, PPE & equipment to crop off T-Bar F/PL-3900 x 150 x 16 1
AFT-PORT THRUSTER VDF existing steel/remove and reinstall AFT PORT Thruster VDF room AL-2300 x 75/150 x 7 7
ROOM Fr 65 to 67 EL due to interference for equipment installatiion and QC/QA/Owner
14 H200-233-001-02, R3 20 18500 Access opened
(MAIN DECK) inspection was carried out at erection stage. sketch and as BKT-500 x 250 x 10 2
instructed by the yard/ owner's representatives. PE-1200 x Dia 500 x 10 1
DBLR - Dia1330 x 10 1
AL-11100 x 75/150 x 7 1
PL-3900 x 2300 x 12 1
T-Bar W/PL-3900 x 640 x 10 1
Supply skilled manpower, tools, PPE & equipment to crop off T-Bar F/PL-3900 x 150 x 16 1
AFT-PORT THRUSTER VDF existing steel/remove and reinstall AFT PORT Thruster VDF room
Fr 65 to 67 EL due AL-2300 x 75/150 x 7 7
15 H200-233-001-02, R3 ROOM 21 to interference for equipment installatiion and QC/QA/Owner Access opened
18500 BKT-500 x 250 x 10 2
(MAIN DECK) inspection was carried out at erection stage. sketch and as
instructed by the yard/ owner's representatives. PE-1200 x Dia 500 x 10 2
DBLR - Dia1330 x 10 2
AL-11100 x 75/150 x 7 1

FWD-PORT THRUSTER
ROOM Access is not
16 H200-233-001-02, R3 1 opened
(MAIN DECK)

FWD-STBD THRUSTER Access is not


17 H200-233-001-02, R3 ROOM 3 opened
(MAIN DECK)

STBD MID THRUSTER ROOM


Access is not
18 H200-233-001-02, R3 8 opened
(MAIN DECK)