Single Loop Fire Alarm Control Panel

The AX-CTL-1C is a member of the industry leading Axis AX


product family. The AX-CTL-1C is a small, compact single loop
fire alarm control panel for use in cost sensitive fire alarm
installations, where less than 126 addressable points are
required. The AX-CTL-1C contains all of the same features as
the Advanced AX- CTL-1L, AX-CTL-2 and AX-CTL-4 intelligent
fire alarm control panels however in a small compact enclosure.
As a member of the Axis AX product line the AX-CTL- 1C can
easily be utilized in larger applications due to its optional
peer-to-peer networking capabilities.

Designed with installation and service engineers in mind, the


AX-CTL-1C single loop fire alarm control panel is modularly
packaged, using surface mount and dual flash microprocessor
technology, with onboard real time clocks for ease of installation,
troubleshooting, programming and maintenance.
Features
The AX-CTL-1C provides a single Style 4 or Style 6/7 Signaling
Line Circuit (SLC). Communications to the field devices attached 126 Analog Addressable Points
to the SLC is via an advanced, 100% digital protocol with
advantages of being highly immune to noisy environments. The Advanced User Interface w/Graphical LCD
SLC supports up to 126 analog addressable devices (any
combination
“DynamiX” I/O Relationship Programming
of intelligent detectors, input and/or output devices, including
loop powered technology devices). In addition, unique
sub-addressing of various input and/ or output devices is Synchronized Audible and Visual NAC Circuits
permitted expanding on overall AX- CTL-1C system capacity.
Superior Service & Maintenance Diagnostics
The AX-CTL-1C comes with two filtered, voltage regulated
Notification Appliance Circuits (NACs), Class A or B, each rated AD-NeT-PluS Peer-to-Peer Networking
2 Amp @ 24 VDC. Due to exceptional regulation and high rating,
the onboard NAC outputs provide compatibility with most listed Automatic Drift Compensation per Detector
notification appliance devices.
Automatic Detector Testing w/Maintenance Alert
The AX-CTL-1C single loop fire alarm control panel has
resettable and non-resettable power outputs; each rated 0.5
Alarm Verification and P.A.S.
Amp @ 24 VDC for connection to four-wire conventional smoke
detectors and/or ancillary devices. Each AX-CTL-1C contains
three, field programmable, Form “C” relay contacts rated 1 Amp Style 4, 6 & 7 SLC Operation (supports loop powered
@ 30 VDC, defaulted as a fail-safe trouble relay, alarm relay, technology)
and supervisory relay.
Class A or B NAC Circuits
Simplifying and reducing initial system set-up, each AX- CTL-1C
single loop fire alarm control panel is equipped with an Voltage Regulated NACs (compatible with most Listed NAC
installer-friendly “Auto-Learn/Loop Detection” feature that devices)
permits the rapid recognition of all signaling line circuit devices.
This rapid recognition simplifies the assignment of critical life Multi-Pattern and Two-Stage NAC Control
safety functions immediately. Assignments include: intelligent
detector type and operation criteria, addressable input device
recognition as an alarm input and addressable output control on
a general alarm basis.

Page 1 of 5
www.advancedco.com

Designed with built-in powerful installation and customization


tools, the AX-CTL-1C can adapt to virtually any application
Features Cont.
requirement. With DynamiX programming, typical time
consuming complexities associated with I/O relationship Network-Wide Audible and Visual Synchronization
programming such as two-stage multi-pattern NAC control,
intelligent detector drift compensation, precision “Auto-Learn/Loop Detection” Programming
response/sensitivity mode settings, flexible timing functions, and
more, are sharply reduced. Built-in Intelligent Multi-Meter
The AX-CTL-1C single loop fire alarm control panels are fully
Optional ipGateway for text and email status notification
field programmable, via the onboard graphical LCD display and
alphanumeric keypad. Front panel programming may
encompass defining input to output relationships, configuring Network-Wide Audible and Visual Synchronization
output circuit characteristics, entering zone, device, and other
text descriptions, and configuring multiple user-access level “Auto-Learn/Loop Detection” Programming
passwords.
Listings and Approvals
To maximize the capability and flexibility of the single loop fire
alarm control panel and to expand upon the customization of an ETL ANSI/UL 864 Listed: 101564744NYM-001
installation, the standard Advanced Windows based PC-NeT
field configuration tool is compatible with the AX-CTL-1C. The
PC-NeT field configuration tool is a powerful, user-friendly CSFM Approved: Pending
programming tool that allows users to perform virtually any I/O
relationship with multiple criteria. Simple drop- down menus with NYCFD COA - Pending
point-and-click operation make project commissioning and
troubleshooting fast and efficient. The integral power supply offers status LEDs, temperature
compensated charging, and the ability to operate directly from
The AX-CTL-1C single loop fire alarm control panel can the batteries when AC supply is not yet available at the
accommodate remote graphical LCD annunciators (with or installation site. A unique built-in intelligent multi-meter allows
without system control capabilities) on the Ad-NeT- PluS technicians to interrogateany input and/or output and diagnose
peer-to-peer network. Multiple annunciator locations can be potential time consuming trouble issues with virtually no
created based on installation demands. These locations can complications or aggravation.
have either: no system control, partial system control, or full
system control. When installations exceed a single panel’s With an AX-CTL-1C single loop fire alarm control panel,
capacity, the Advanced Ad- NeT-PluS peer-to-peer network may servicing a customer after installation can be as simple as
be implemented, providing up to 200 network nodes. The adding an Advanced ipGateway (AX-LAN). The ipGateway can
Ad-NeT-PluS is completely field programmable for inter panel provide real time text and email alerts of system status via
functionality or segregation of information and control based on internet access.
installation requirements.

Designed with the technician in mind, each module of the


AX-CTL-1C single loop fire alarm control panel is easy to install
and service.

Page 2 of 5
www.advancedco.com

Wiring Diagram

Page 3 of 5
www.advancedco.com

Specification
Operating Voltage 120 VAC (1.4A) - 240 VAC (0.7A), 50/60Hz
System-Brown-Out 98 VAC nominal
Battery Circuit
Charging Voltage 27.4 VDC nominal
Temp. Compensated Charging Current 2 Amp
Battery Derating Factor 0.83A
Battery Capacity 7 Ah (minimum), 48 Ah (maximum)
Battery Fuse 5A @ 240 VAC, Time Delayed, Ceramic, High Breaking (In-line
Wire Link)
Fire, Supervisory, and Trouble Relays (Power Limited - when utilizing system power)
Type Form "C"
Rating 1A @ 30 VDC/VAC
Trouble Relay Normally Active (fail-safe operation)
Auxiliary Power Outputs (Power Limited)
Resettable
Voltage 24 VDC
Current 0.5A
Reset Time 10-15 Seconds
Non-Resettable
Voltage 24 VDC
Current 0.5A
Humidity 85% RH
Temperatures
Operating 32 o F - 120 o F (0 o C - 49 o C)
Recommended Room 60 o F - 86 o F (15 o C - 27 o C)
Enclosure Dimensions 17 7/8"H x 14 3/4"W x 5 5/8"D
SLC Loop (Power Limited)
Class (Style) Class A or B (Style 4, 6 or 7)
Voltage 24 VDC
Minimum Return Voltage 17 VDC
Current 0.5A
NAC Circuits (Power Limited)
Class (Style) Class A or B
Voltage 24 VDC (filtered and regulated)
Minimum Return Voltage 16 VDC
Current 2A (each)
Maximum Voltage Drop 3 VDC
Maximum Line Impedance 1.5Ω
RS232 Supervised, Optically Isolated
Baud Rate 9600
Parity None
Data Bits 8
Stop Bits 1
Base Card Operating Current Quiescent Alarm
AX-CTL-1PCB 110 mA 195 mA

* Refer to individual Axis AX Series module data sheets for specific specifications regarding optional modules.

Page 4 of 5
www.advancedco.com

Order codes and Options


AX-CTL-1C* Single Loop Fire Alarm Control Panel with Power supply/charger, 1 SLC, 2 NACs, 3 auxiliary
relays (enclosure supports batteries 7Ah - 18Ah)
AX-CTL-1C-BCP* Optional Battery Cover (Dress) Plate
AX CTL Base Card Option Modules**:
AX-NET4 Network Interface Card (Style 4)
AX-NET7 Network Interface Card (Style 7)
AX-RL8 8-Way Relay Output Card (Programmable)
D9068P Serial Expansion Board, requires AX-SEB and AX-DACT
AX-SEB Serial Expansion Board, Required with D9068P
AX-DACT DACT Metal Mounting Plate, required with D9068P

* For gray enclosure, add the suffix "G" to the part number.
** Refer to individual Axis AX module data sheets for peer to peer network and peripheral bus optional modules.

Check if this document is up to date | Give us feedback

Advanced, The Bridges, Balliol Business Park, Newcastle upon Tyne, NE12 8EW, UK T: +44 (0)345 894 7000, E: [email protected],
W: www.advancedco.com
As our policy is one of constant product improvement the right is therefore reserved to modify product specifications without prior notice.

Page 5 of 5

You might also like