LRK-1000 Series Specifications
Quality Management
System - ISO 9001:2015
Doc #11841 Revision L dated APR 2021, page 2 of 7
LRK-1000 Series Part Number Ordering Information/Tables 1 & 2
Table 1 - Typical System Noise Temperature with Various Options (Add to T LNA)
System —— 1:1 —— —————— 1:2 ——————
Configuration: Pol. 1 Pol. 2 Standby
Standard Configuration (Add to TLNA) .......................................... 5 K .............................. 5 K 9K 14 K
With 40 dB Crossguide Coupler(s) ............................................... 7 K .............................. 7 K 11 K 16 K
With Transmit Reject Filter(s) ....................................................... 18 K ............................. 18 K 22 K 27 K
With Tx Filter(s) and Coupler(s) .................................................... 20 K ............................. 20 K 24 K 29 K
Example: For a 1:1 system with Tx filter, crossguide coupler and 80 K LNAs, TLNA = 80 K at +23 °C and passive
losses = 20 K at +23 °C; thus, TSYS = 100 K at +23 °C. What is TSYS at +50 °C?
From the table, NT2 /NT1 at 50 °C = 1.17 for the LNAs and 1.09 for the passive losses:
NT2 = 1.17 x (80 K) + 1.09 x (20 K) = 94 K + 22 K = 116 K at +50 °C.
Unit Current Window Width ±5% to ±25% of nominal; user selectable in 5% steps (applies to all monitored unit currents)
External Alarm Inputs Optionally up to one per unit; require sinking 5 mA at 5 Vdc to negate alarm
Parallel I/O Interface Control inputs: Contact closures to ground; require sinking 20 mA at 15 Vdc
Status outputs: Form ‘C’ dry contacts; 100 Vdc, 0.5 A, 3 W max (resistive load)
Controller Dimensions 19” (483 mm) W x 1.72” (43.7 mm) H x 17.5” (445 mm) D; 7.6 lb (3.4 kg)
Cable Length to Plate Assy Order cable separately. 100 ft (30 m) to 250 ft (75 m) lengths in 50 ft (15 m) increments are
standard; other lengths (up to 500 ft or 150 m) are available by special order.
AC Input (standard) 100-135 or 180-240 Vac, 47-63 Hz, 100 W; Dual AC inputs and dual redundant power supplies.
Reliability MTBF: 48,200 hours; MTTR: less than 30 minutes with spares and proper technical person.
J1, J2 – LINE 1, LINE 2 Dual power entry modules contain the AC line input connectors. System can be powered from
(IEC 320-C14) separate AC lines if desired. Either or both power supplies are capable of operating the system.
J3 – PLATE ASSY Cable to plate assembly carries unit power (for line drivers, LNAs or LNBs) and switch drive signals.
(37-pos D, Female) Order cable separately. Standard lengths are 100’ (30 m) to 250’ (75 m) in 50’ (15 m) increments;
other lengths are special order. An adapter cable mates the controller to legacy system cables.
J6 – SERIAL I/O and RS-232/RS-422/RS-485 connector for user M&C System. Commands provide monitoring,
J7 – SERIAL LOOP controlling, and configuration. Interconnect cable lengths to 4000 ft (1200 m) with RS-422 or RS-
(9-pos D Female) 485. A serial loop connector provides a convenient connection for daisy-chained systems.
J5 – REMOTE LINK For connection via a proprietary RS-422 link (up to 4000 ft/1200 m) to an optional, second RSC,
(9-pos D Male) which duplicates Local control functions at a secondary site.
J9 – NETWORK 10/100 Base T Ethernet connection port via standard RJ-45 connector. Supports SNMP v1, v2c and v3.
(RJ-45)
J4 – EXT ALARM External Alarm inputs. Substitute for or combine with internal unit current monitor alarms. Allows an
(9-pos D Female) external signal to indicate unit failure. Unused inputs can be used as status inputs to M&C system.
J8 – PARALLEL I/O Parallel I/O (discrete logic) connection for limited control and monitoring of the system.
(37-pos D Male) Form ‘C’ relay contact outputs (1:2 system example):
• Unit 1 status • PS 1 status • Pol 1: Unit 1 or Unit 3
• Unit 2 status • PS 2 status • Pol 2: Unit 2 or Unit 3
• Unit 3 status • Local/Remote mode • Auto/Manual mode
Control inputs—contact closure to ground (1:2 system example):
• Pol 1 Unit 1 select • Pol 2 Unit 2 select • Auto/Manual select
• Pol 1 Unit 3 select • Pol 2 Unit 3 select
0.25 [6.3]
OPTIONAL
WAVEGUIDE
0.75 [19.0] OFFLINE 6.40 [162.6]
MOUNTING
RF INPUT
SURFACE
TYPE N FEMALE
LNA 2
3.40 [86.4]
9.00
[228.6]
7.25
S1
[184.2]
OPTIONAL
TRANSMIT REJECT
FILTER
LNA 1
OPTIONAL INPUT
CROSSGUIDE
W3
COUPLER
8.50 [215.9]
11.50 [292.1]
NOTES:
1. OUTPUT ISOLATOR INCLUDED WITH STANDARD SYSTEM.
2. OPTIONAL TRANSMIT REJECT FILTER, CROSSGUIDE COUPLER, OUTPUT
COAXIAL COUPLER AND OFFLINE INPUT/OUTPUT SHOWN.
3. DIMENSIONS ARE IN INCHES [mm].
7.4 [188]
3.50 [88.9]
0.12 [3.2]
TO CONTROL PANEL
Outline 12670-2
6
LRK-1000 Series Outline Drawing
OPTIONAL
0.25 [6.3]
LNA 2
LNA 3
OFFLINE INPUT
TYPE N FEMALE
WAVEGUIDE MOUNTING SURFACE
0.75 [19]
6.40 [163]
20.00 3.40
[508] [86.4]
9.00
S2
[229] POL 1 INPUT
7.25 (WR75F)
S1
OPTIONAL POL 1 [184]
COUPLED OUT OPTIONAL INPUT
TYPE N FEMALE CROSSGUIDE COUPLERS 4.50
TYPE N FEMALE
[114]
OPTIONAL POL 2
COUPLED OUT
TYPE N FEMALE
POL 2 INPUT
(WR75F)
LNA 1
11.25 [286]
14.6 [372]
NOTES:
3.00
[76.2]
8.1
[205]
OPTIONAL 3.50
[88.9]
TRANSMIT
REJECT
FILTERS
Outline 12671-3
SMP Division For more detailed information, please refer to the corresponding CPI technical description if one
has been published, or contact CPI. Specifications may change without notice as a result of
Satcom Products additional data or product refinement. Please contact CPI before using this information for system
design.
tel: +1 (669) 275-2744
© 2021 Communications & Power Industries LLC. Company proprietary: use and reproduction is
email: [email protected] strictly prohibited without written authorization from CPI.
7
web: www.cpii.com/satcom
Doc #11841 Revision L dated APR 2021, page 7 of 7