Walls and Columns Rft-Zeraay Direction r00

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

GENERAL NOTES

1. DIMENSIONS
1.1 All dimensions are in millimeter.
1.2 All dimensions should be checked with the road planning
and Arch. drawings
2. CODES
2.1 The bridge has been designed according to the Egyptian
Code of Practice for Planning, Design and Construction

04 67T16@150-L=(1805-2000)

04 67T16@150-L=(1805-2000)
of Bridges and Elevated Intersections (ECP207-2015.)

03 67T16@150-L=(2000-2160)

03 67T16@150-L=(2000-2160)
3. DRAWINGS
3.1 All structural drawings should be revised with Road planning

02 36T16@150-L=(2080-2160)
02 36T16@150-L=(2080-2160)
190 190 drawings.
190 190 190 190
3.2 Do not measure from drawings. All dimension should be read

a=1065-1260

a=1065-1260
or computed.

a=1260-1420

a=1260-1420
a=1340-1420

a=1340-1420
4. REINFORCED CONCRETE.
550 550 4.1 The reinforcement bars are high grade steel 60 with minimum
550 550 550 550 yield strength of 4000 kg/cm.
- minimum yield strength of 2400 kg/cm for mild steel bars.
4.2 The Concrete protective Cover for steel shall
be as follows, unless otherwise noted:
a) 30mm for Columns & Walls.
b) 50mm for Foundations.
4.3 The Splice Length should be according to the Egyptian code
of practice for the design of the reinforced concrete structures.
4.4 The reinforced Concrete should have a minimum characteristic
2
-Fcu=400 kg/cm (Slab)

07 53T16@150-L=(835-1810)

07 53T16@150-L=(835-1810)
04 67T16@150-L=(1805-2000)

04 67T16@150-L=(1805-2000)

00 09-07-2024 FOR APPROVAL

05 33T16@150-L=(1755-1805)

05 33T16@150-L=(1755-1805)
REV. DATE DESCRIPTION

190 190 190 190 190 190


PROJECT TITLE :

a=1015-1065

a=1015-1065
a=1065-1260

a=1065-1260

a=95-1070

a=95-1070
RING ROAD
BUS RAPID TRANSIT
550 550 550
550 550 550

OWNER :

OWNER CONSULTANT :

08 263T16@100-L=1960
09 263T16@100-L=1960
240 240
1357T16@100-L=1920
12 57T16@100-L=1920

240 240

1170
1170
CONTRACTOR :
1130
1130

550 550
550 550

CONTRACTOR CONSULTANT :

DRAWING TITLE :
10 36T16@100-L=(1790-1960)
11 36T16@100-L=(1790-1960)

240
WALLS AND COLUMNS REEINFORCEMENT
240
ZERAAY DIRECTION BETWEEN AXIS (20~26)
a=1000-1170
a=1000-1170

SHEET(1 -4)
550
DESIGN CHECK DATE
550
M.SAID A.H.KH JUL - 2024
SCALE DWG NO.

AS SHOWN EG-23-02- STR-BRT-MS-WSD-RFT- 301 -R00


GENERAL NOTES
1. DIMENSIONS
1.1 All dimensions are in millimeter.
1.2 All dimensions should be checked with the road planning
and Arch. drawings
2. CODES
2.1 The bridge has been designed according to the Egyptian
Code of Practice for Planning, Design and Construction
of Bridges and Elevated Intersections (ECP207-2015.)
3. DRAWINGS
3.1 All structural drawings should be revised with Road planning
12000
240

11760 drawings.
01 10T12@100-L=12000-SIDE BARS (R&L) 3.2 Do not measure from drawings. All dimension should be read
27 10T12@100-L=12000-SIDE BARS (R&L)
or computed.
4. REINFORCED CONCRETE.

4.1 The reinforcement bars are high grade steel 60 with minimum
yield strength of 4000 kg/cm.
- minimum yield strength of 2400 kg/cm for mild steel bars.
4.2 The Concrete protective Cover for steel shall
be as follows, unless otherwise noted:
a) 30mm for Columns & Walls.
b) 50mm for Foundations.
4.3 The Splice Length should be according to the Egyptian code
of practice for the design of the reinforced concrete structures.
4.4 The reinforced Concrete should have a minimum characteristic
2
-Fcu=400 kg/cm (Slab)

240
12000 1760 00 09-07-2024 FOR APPROVAL
12000 01 10T12@100-L=12000-SIDE BARS (R&L) 28 10T12-L=2000 REV. DATE DESCRIPTION
10T12@100-L=12000-SIDE BARS (R&L)
PROJECT TITLE :
RING ROAD
BUS RAPID TRANSIT

OWNER :
190
190

2515
5355

190
3580

190
26 1T12-L=3770 11810 OWNER CONSULTANT :
22 1T12@150-L=12000-SIDE BARS (R&L)

CONTRACTOR :

CONTRACTOR CONSULTANT :
190

190

11810
22 1T12@150-L=12000-SIDE BARS (R&L) 9000
23 6T12@150-L=9000-SIDE BARS (R&L) DRAWING TITLE :
WALLS AND COLUMNS REEINFORCEMENT
ZERAAY DIRECTION BETWEEN AXIS (20~26)
SHEET(1 -4)
DESIGN CHECK DATE
M.SAID A.H.KH JUL - 2024
SCALE DWG NO.

AS SHOWN EG-23-02- STR-BRT-MS-WSD-RFT- 302 -R00


GENERAL NOTES
1. DIMENSIONS
1.1 All dimensions are in millimeter.
1.2 All dimensions should be checked with the road planning
and Arch. drawings
2. CODES
2.1 The bridge has been designed according to the Egyptian
Code of Practice for Planning, Design and Construction
of Bridges and Elevated Intersections (ECP207-2015.)
3. DRAWINGS
3.1 All structural drawings should be revised with Road planning
drawings.
3.2 Do not measure from drawings. All dimension should be read
or computed.
4. REINFORCED CONCRETE.

4.1 The reinforcement bars are high grade steel 60 with minimum
yield strength of 4000 kg/cm.
- minimum yield strength of 2400 kg/cm for mild steel bars.
4.2 The Concrete protective Cover for steel shall
be as follows, unless otherwise noted:
a) 30mm for Columns & Walls.
b) 50mm for Foundations.
4.3 The Splice Length should be according to the Egyptian code
of practice for the design of the reinforced concrete structures.
4.4 The reinforced Concrete should have a minimum characteristic
2
-Fcu=400 kg/cm (Slab)

00 09-07-2024 FOR APPROVAL


REV. DATE DESCRIPTION

PROJECT TITLE :
RING ROAD
BUS RAPID TRANSIT

OWNER :
340 340
340 340 340 340
[email protected] [email protected] [email protected]
19 19 19
L=1200 L=1200 L=1200 340 340
15 4T16-L=2420

[email protected]
19
4T16-VL. RFT. 4T16-VL. RFT. 4T16-VL. RFT. 4T16-VL. RFT. 4T16-VL. RFT. 4T16-VL. RFT. L=1200
29 4T16-L=2280
14 4T16-L=2340

14 29

14 4T16-L=2340
14 4T16-L=2340
L = 2340 L = 2280 15 15 14 14
L = 2420 L = 2420 L = 2340 L = 2340 4T16-VL. RFT. 4T16-VL. RFT.
15 4T16-L=2420

16 4T16-L=2260
16 4T16-L=2260
16 16
1440

1440
1360

1360

1360

1360
L = 2260 L = 2260
[email protected]. [email protected]. [email protected].
20

1280

1280
L=1840 20 20
L=1840 L=1840
[email protected].
20
L=1840

640 580 640 640 640 640


640 640 OWNER CONSULTANT :

CONTRACTOR :

[email protected]
340 340 19 [email protected] [email protected]
L=1200 340 340 19 19
L=1200 340 340 L=1200
4T16-VL. RFT. 4T16-VL. RFT. 4T16-VL. RFT. 4T16-VL. RFT. 4T16-VL. RFT.
18 4T16-L=2060
18 4T16-L=2060

21 4T16-L=2010
21 4T16-L=2010
18 18
17 4T16-L=2150
17 4T16-L=2150

17 17 21
L = 2150 L = 2150 L = 2060 L = 2060 L = 2010 4T16-VL. RFT.
21
CONTRACTOR CONSULTANT :
L = 2010
1170

1170

1080

1080

[email protected].

1030

1030
20 [email protected]. [email protected].
L=1840 20 20
L=1840 L=1840

640 640 640 640 640 640

DRAWING TITLE :
WALLS AND COLUMNS REEINFORCEMENT
ZERAAY DIRECTION BETWEEN AXIS (20~26)
SHEET(3 -4)
DESIGN CHECK DATE
M.SAID A.H.KH JUL - 2024
SCALE DWG NO.

AS SHOWN EG-23-02- STR-BRT-MS-WSD-RFT- 303 -R00


GENERAL NOTES
1. DIMENSIONS
1.1 All dimensions are in millimeter.
1.2 All dimensions should be checked with the road planning
and Arch. drawings
2. CODES
2.1 The bridge has been designed according to the Egyptian
Code of Practice for Planning, Design and Construction
of Bridges and Elevated Intersections (ECP207-2015.)
3. DRAWINGS
3.1 All structural drawings should be revised with Road planning
drawings.
3.2 Do not measure from drawings. All dimension should be read
or computed.
4. REINFORCED CONCRETE.

4.1 The reinforcement bars are high grade steel 60 with minimum
yield strength of 4000 kg/cm.
- minimum yield strength of 2400 kg/cm for mild steel bars.
4.2 The Concrete protective Cover for steel shall
be as follows, unless otherwise noted:
a) 30mm for Columns & Walls.
b) 50mm for Foundations.
4.3 The Splice Length should be according to the Egyptian code
of practice for the design of the reinforced concrete structures.
4.4 The reinforced Concrete should have a minimum characteristic
2
-Fcu=400 kg/cm (Slab)

00 09-07-2024 FOR APPROVAL


REV. DATE DESCRIPTION

PROJECT TITLE :
RING ROAD
BUS RAPID TRANSIT

OWNER :

OWNER CONSULTANT :

CONTRACTOR :

CONTRACTOR CONSULTANT :

DRAWING TITLE :
WALLS AND COLUMNS REEINFORCEMENT
ZERAAY DIRECTION BETWEEN AXIS (20~26)
SHEET(4 -4)
DESIGN CHECK DATE
M.SAID A.H.KH JUL - 2024
SCALE DWG NO.

AS SHOWN EG-23-02- STR-BRT-MS-WSD-RFT- 304 -R00