MMCM-C - 1x32a

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

DATASHEET - MMCM-C32/1

Miniature circuit breaker (MCB), 32 A, 1p, characteristic: C

Part no. mMCM-C32/1


Catalog No. 138882

Delivery program
Basic function Miniature circuit-breakers

Number of poles 1 pole

Tripping characteristic C

Application Switchgear for residential and commercial applications

Rated current In A 32

Rated switching capacity according to IEC/EN 60898-1 Icn kA 10

Product range mMCM

Technical data
Electrical
Rated switching capacity according to IEC/EN 60898-1 Icn kA 10

Rated insulation voltage Ui V 440

Rated impulse withstand voltage Uimp kV 4

lifespan

Electrical Operations ≧ 10000

Mechanical Operations ≧ 20000


References
Auxiliary switch for subsequent installation ZP-IHK 286052

Tripping signal contact for subsequent installation ZP-NHK 248437

Remote control and automatic switching device Z-FW/LP 248296

Switching interlock Z-IS/SPE-1TE 274418


Mechanical
Standard front dimension mm 45

Device height mm 80

Mounting Quick attachment with 3 latch positions for top-hat rail IEC/EN 60715

Degree of Protection IP20

Terminals top and bottom Open mouthed/lift terminals

Terminal protection BGV A3, ÖVE-EN 6

Thickness of busbar material mm 0.8 - 2

Design verification as per IEC/EN 61439


Technical data for design verification

Rated operational current for specified heat dissipation In A 32

Heat dissipation per pole, current-dependent Pvid W 0

Equipment heat dissipation, current-dependent Pvid W 3.7

Static heat dissipation, non-current-dependent Pvs W 0

Heat dissipation capacity Pdiss W 0

Operating ambient temperature min. °C -25

Operating ambient temperature max. °C 75

linear, per +1 °C, results in a 0.5% reduction of current carrying capacity

IEC/EN 61439 design verification

10.2 Strength of materials and parts

10.2.2 Corrosion resistance Meets the product standard's requirements.

10/30/2020 Eaton 138882 ED2020 V73.0 EN 1/2


10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements.

10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements.

10.2.3.3 Verification of resistance of insulating materials to abnormal heat Meets the product standard's requirements.
and fire due to internal electric effects

10.2.4 Resistance to ultra-violet (UV) radiation Meets the product standard's requirements.

10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated.

10.2.6 Mechanical impact Does not apply, since the entire switchgear needs to be evaluated.

10.2.7 Inscriptions Meets the product standard's requirements.

10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated.

10.4 Clearances and creepage distances Meets the product standard's requirements.

10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated.

10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated.

10.7 Internal electrical circuits and connections Is the panel builder's responsibility.

10.8 Connections for external conductors Is the panel builder's responsibility.

10.9 Insulation properties

10.9.2 Power-frequency electric strength Is the panel builder's responsibility.

10.9.3 Impulse withstand voltage Is the panel builder's responsibility.

10.9.4 Testing of enclosures made of insulating material Is the panel builder's responsibility.

10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will
provide heat dissipation data for the devices.

10.11 Short-circuit rating Is the panel builder's responsibility. The specifications for the switchgear must be
observed.

10.12 Electromagnetic compatibility Is the panel builder's responsibility. The specifications for the switchgear must be
observed.

10.13 Mechanical function The device meets the requirements, provided the information in the instruction
leaflet (IL) is observed.

Technical data ETIM 7.0


Circuit breakers and fuses (EG000020) / Miniature circuit breaker (MCB) (EC000042)

Electric engineering, automation, process control engineering / Electrical installation, device / Miniature circuit breaker system (MCB) / Miniature circuit breaker (MCB)
([email protected] [AAB905014])

Release characteristic C

Number of poles (total) 1

Number of protected poles 1

Rated current A 32

Rated voltage V 230

Rated insulation voltage Ui V 440

Rated impulse withstand voltage Uimp kV 4

Rated short-circuit breaking capacity Icn EN 60898 at 230 V kA 10

Rated short-circuit breaking capacity Icn EN 60898 at 400 V kA 10

Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V kA 15

Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V kA 15

Voltage type AC

Frequency Hz 50 - 60

Current limiting class 3

Suitable for flush-mounted installation No

Concurrently switching N-neutral No

Over voltage category 3

Pollution degree 2

Additional equipment possible Yes

Width in number of modular spacings 1

Built-in depth mm 70.5

Degree of protection (IP) IP20

Ambient temperature during operating °C -25 - 75

Connectable conductor cross section multi-wired mm² 1 - 25

Connectable conductor cross section solid-core mm² 1 - 25