CONDENSING UNITS 50°C CONDENSING UNITS

FOR HIGH
ambient temperature AMBIENT
TEMPERATURE
WITH
SEMI-HERMETIC
COMPRESSORS

F U L L C ATA L O G U E

BRAND SOLUTIONS
CONDENSING UNITS
FOR HIGH AMBIENT
TEMPERATURE
WITH COPELAND AND
BITZER SEMI-HERMETIC
COMPRESSOR

GENERAL FEATURES FAN MOTORS


• Condensing units with Bitzer and Cope- •All fans are for 230V (+/-10%) /
land semi-hermetic compressors precharge ~1/50-60Hz supply;
of mineral oil for R22 applications and • We made whole ranges with a total of 4
POE oil for R404A applications; types of fans Ø 350 400 450 500mm;
• Electronic motor protection; •All fans are strong and suitable for high
•Electronic oil differential pressure switch, ambient temperature with at least 50°C
when needed; guaranteed when work at 60Hz;
•Liquid injection mounted (LT for R22 • All fans are with metallic blades;
application); BASE FRAME •Ø 450 and 500mm are newest models
• Vibration damper on compressor available on the market. Quiet operation
• Special base frame with 2,5mm thick and performance are assured.
discharge side; metal sheet and strong fixing profiles
• Liquid receiver with pressure relief valve handling the units is easier thanks to
connection, valve and pressure service port higher frame on the front and “windows”
on outside; on the side. Also less risk of tubes damage,
components and paint is assured when you
• Copper tubes and aluminium fin
put units on work position.
condenser;
• Compressor discharge tubes and, where
• Condenser fans 230V
present, liquid injection tubes are always
(+/-10%)/~1/50-60Hz thermally
fixed to the frame for max strenght of the
protected, suitable to run under fan speed
whole assembly.
control;
•HP/LP pressure safety switch (HP cut-out
@ 27barg/diff. = 4bar and LP cut out @
0barg/diff. = 1bar);
•Electrical box for fan motors, pressure CONDENSER BRACKETS
switch and optional items (crankcase
heater and electronic fan speed regulator).
• Max strenghth of the overall assembly
by the use of brackets from the condenser
to the base frame.

SIDE PANELS
ON THE CONDENSERS
• Aluminium panels fitted on both sides
for protection of tubes and headers of all
condensers.

2
S
N
O
I
T
U
L
O
S

PAINT ON BRAZING ELECTRICAL BOX


• Condenser and receiver brazed connec- • We use the same E-Box model for all
D

tion are painted in order to protect from units. Each E-Box can serve maximum 2
oxidation. condenser fan motors. Then in the version
N

with 4 fans are fitted 2pcs of the same


A

E-Box model.
PAINT The E-Box is also wired with the pressure
R

safety switch and could also be wired with


• Good quality paint: metalized paint
B

RAL 9006. Test in salt fog under ISO- optional items like crankcase heater and
9227 test for sunlight decay the original electronic fan speed regulator.
brightness. The E-Box is always coupled with the
pressure safety switch on the same bracket
in order to have a simple subassembly to
LARGER LIQUID RECEIVER manage for logistics matter.
Wiring diagram: the scheme is attached on LABEL
• An oversized liquid receiver can be back cover of each E-Box of every the unit • The identification label with main
fitted on demand for all units except for supplied for an easy installation and/or technical info and serial number of the
the following sizes: 1x350 units with 3 lt maintenance operation. unit is placed on the base frame near the
receiver and units with 50 lt receiver as a compressor.
standard. 1) Rivacold name and address; 2) Code;
UNLOADED START 3) Supply voltage; 4) Gas; 5) Serial num-
ber; 6) Absorption; 7) Model compressor.
CRANCKASE HEATER • This could be an interesting optional
when is used big motor compressor on
• Applicable for all units. direct start. In this way it is possible to re-
duce starting absorption. For this optional PACKAGE
item the compressor discharge line needs • 3 different pallets and 5 cardboards
ELECTRONIC FAN SPEED to be changed for the NRV valve fitting cover the whole range.
REGULATOR (make a specific request).

CCU R22/50Hz R22/60Hz R404A/50Hz R404A/60Hz R134a


BCU MBP LBP MBP LBP MBP LBP MBP LBP MBP/50Hz MBP/60Hz
Operating
range +5°C / -20°C -15°C / -40°C +5°C / -20°C -15°C / -40°C +5°C / -20°C -15°C / -40°C +5°C / -20°C -15°C / -40°C +10°C / -20°C +10°C / -20°C

Compressor
power 0,5 - 40 HP 0,5 - 30 HP 0,5 - 40 HP 0,5 - 30 HP 0,5 - 40 HP 0,5 - 30 HP 0,5 - 40 HP 0,5 - 30 HP 0,5 - 33 HP 0,5 - 33 HP

Refrigerating 1440 - 50470 W 474 - 19440 W 1700 - 58690 W 565 - 22430 W 1380 - 45420 W 440 - 25580 W 1612 - 51810 W 520 - 25038 W 924 - 36281 W 1095 - 42354 W
capacity Ta 45°C / Te -10°C Ta 45°C / Te -30°C Ta 45°C / Te -10°C Ta 45°C / Te -30°C Ta 45°C / Te -10°C Ta 45°C / Te -30°C Ta 45°C / Te -10°C Ta 45°C / Te -30°C Ta 45°C / Te -10°C Ta 45°C / Te -30°C