Data centers require scalable design to: Data center design changes rapidly in terms of:
a Manage different heat loads for different areas a Shape & architecture
a Manage an increasing heat load over time a Computing capacity
a Accomodate new areas to be cooled a New technologies, always adopting the latest rack
and server solutions
a Heat dissipation
02/03
02/03
Energy efficiency is crucial in data centers that require the 40kW in less than one square meter (or 10 square feet).
latest cooling technologies to ensure the reliability and high Cooling such loads is a serious challenge for the air
performance of these critical applications. conditioning industry and only solid technological innovations
backed by R&D and experienced staff can provide the right
Server usage in both upgraded and newly designed data solutions.
centers will, over time, lead to increasingly higher performance
that will eventually result in higher density power loads. The answers lie in the use and combination of the most
sophisticated technologies such as MAGNETIC LEVITATION
The data center environment is critical and requires a and FULL ELECTRONIC MODULATION cooling equipment.
guarantee of reliability, device safety, and modularity.
As a race car needs an experienced driver, high tech
Preparing for the modular infrastructure evolution, components require superb design capacities as well
the IT room has several standards, classifications, as a deep understanding of the application’s requirements.
and certifications to comply with.
Climaveneta range of IT COOLING solutions includes state
The key factor that must be continuously improved is energy of the art, efficient, and reliable cooling technologies for ICT
efficiency to cope with more demanding OPEX requirements, environments.
and the global footprint, which greatly affects CAPEX.
The growth of microprocessor performance leads to Redundancy is the typical way to increase uptime.
the growth of power generated density. In facing the cooling problems only smart solutions can
avoid the disaster of shut-down while limiting CAPEX
Besides this, progressive diffusion of incoming and OPEX. Reliability must look at a full 360° view.
virtualisation and blade servers characterised by
increasing power in limited volumes, leads to the
unrelenting growth of loads which consequently
increases thermal power per m2.
BUILDING AN ENHANCED
MODEL FOR TOP DATA CENTER
EFFICIENCY
Built on the profound experience of both the Climaveneta and RC, the
new Climaveneta IT Cooling solutions merge the best technologies of
the two brands with the top quality approach of Mitsubishi Electric to
ensure:
HIGH
Density Zone
> 25 kW/rack
MEDIUM
Density Zone
10 - 20 kW/rack
LOW
Density Zone
< 5 kW/rack
04/05
04/05
Climaveneta IT Cooling solutions put great efforts on the use of high quality components such as the EC
PUL (polymeric ultralight) fans and the full DC inverter technology applied both on the compressors and
fans.
This means that air conditioning systems are required to be more and more performing,
even if space available is still the same. In this sense, Climaveneta for IT COOLING range
ensures
the best power/footprint ratio in the market.
Climaveneta for IT COOLING range features 360° versatility, both a s concerns capacities, as well as
configurations. Perimeter air conditioners, together with close-coupled solutions ensure effective cooling
for low-medium and high density areas. Data center infrastructures and PDU solutions complete the range
provinding customers a complete cooling package for your data center.
Climaveneta Close control units have been designed to manage such air suction
temperature up to 40°C. Available both as Dual Fluid (DF) and Free Cooling (FC)
versions, NEXT air conditioners optimize the primary water circuit performance
even with high temperature fluids.
UP TO
The chiller’s efficiency and the free cooling operation are therefore maximized 18-27°C 40°C
also when outdoor temperatures are high.
Climaveneta’s approach to cooling dependability goes beyond the unit’s accurate and sturdy design.
It also involves several devices and functions that maximise unit’s uptime in case of emergency
circumstances such as power supply outage.
40% 7% IT IT equipment
equipment
35%
6% Power
Power distrib.
distrib. units units
30%
30%
CRAC
CRAC
25%
Humidification
Humidification
20% 18%
15% UPS
UPS
10% 32% Lighting
Lighting
5%
5%
1% 1% Switchgear/generator
Switchgear/generator
0%
06/07
06/07
CAPEX
Capital Expenditure
OPEX
Operating Expenditure
LOW MEDIUM
Density Zone Density Zone
< 5 kW/rack 10 - 20 kW/rack
Aisle Containment
AISLE CONTAINMENT prevents the
HOT & COLD air from mixing in the
upper section of the racks,
guaranteeing homogeneous air flow.
Hot/Cold aisle
a No mixing between Hot & Cold air
An easy, fast and long-lasting solution; streams in order to avoid energy
the hot & cold aisle is the basic and waste.
essential concept that drives the layout
of all data denters. a Additional 15% energy saving
depending on the data center
layout.
a Through the raised floor, air can
be easily delivered exactly where
required (in front of the rack)
allowing easy management of
redundant cooling units.
08/09
08/09
HIGH
Density Zone
> 25 kW/rack
Aisle Containment +
Localised Cooling to
manage hot spots
CCD (Climaveneta for IT COOLING
Door) & CCV (Climaveneta for IT
COOLING Rack Cooler) guarantee
ideal integration to manage HOT
SPOTS caused by new blade servers,
providing extra local cooling exactly
where it is needed.
a Quick and easy solution with low
initial investments. a Extra cooling only where a Modulating Air flow thanks
required. to EC high efficiency fans.
a Complete integration with The fans adapt to the thermal
existing perimeter CRAC units. a Direct expansion inverter load detected by sensors
type or Chilled water system positioned in the hot and cold
a Immediate energy benefits. for complete cooling system aisle. This increases efficiency
flexibility. and reduces air stratification.
a High efficiency
a Perfect redundancy
a Quick and easy expansion
a Low initial investment
The hot and cold aisle solution overcomes the limits of a traditional
approach where cooling aims to maintain stable room conditions,
forgetting to focus on the racks requirements.
In the last decade the data center design has dramatically The arrangement of rack servers according to
changed. Years ago data center design was not driven by heat this logic allows delivery of cold air-flow exactly where it is
loads, so server distribution in the room was driven by other needed - i.e. typically in front of the racks, greatly reducing
needs leading to only one reference room temperature. This the chances of cold and hot air mixing. This system increases
used to be from 18°C to 24°C and it was an accepted standard the efficiency of the cooling system by 20% if compared to
throughout the world. As soon as server heat generation traditional layouts.
increased, it became clear a more rational distribution of heat
was necessary; this resulted in the Hot & Cold Aisle concept. On the other hand, this new concept requires two levels of
temperatures to be properly defined.The optimisation of these
temperatures leads to greatly improved working conditions.
10/11
10/11
This essential concept drives the layout of the majority of data centers.
AISLE CONTAINMENT
This mix results in air flow with a temperature that reduces the
performance of the data center. If such air goes to the servers
and it is warmer than expected the servers may stop working
due to overheating.
If mixed air goes to the cooling system and it is cooler than air
coming out from the servers, heat exchange is reduced and
then global efficiency is affected.
12/13
12/13
CCD LEGACY
Close-Coupled Solution For High Density Racks
a Zero footprint
14/15
14/15
CRC LEGACY
Rack Cooling Solutions
CRCX: Direct Expansion CRCD: Dual Fluid CRCX ROW: Direct Expansion
with integrated compressor
a DC inverter compressor a DC inverter compressor
a New generation EC brushless fans a Double coil a Installation within the row; do not
a Capacity from 4,7 to 68,3 kW a Capacity from 4,5 to 16,7 Kw require underfloor plenum, ducts or
false-ceilings
a DC inverter compressor integrated
CRCF: Free Cooling within the air conditioner
CRCC: Chilled Water
a Capacity from 14 to 39 kW
a New generation EC brushless fans a DC inverter compressor
a 3-way modulating valve a New-generation EC brushless fans
a Capacity from 16 to 74,7 kW a Capacity from 4,6 to 17,5 kW
a 60% of the year in the free cooling
Mode
ADVANCED TECHNOLOGIES
FOR EFFICIENT DATA CENTERS
Climaveneta IT Cooling leadership in data center cooling systems is
backed by 50 years of experience in the smart integration of premium
technologies for complex IT cooling projects.
SMART THERMAL
ACTIVE REDUNDANCY
ENERGY MANAGEMENT
A real active redundancy achieved through An innovative heat recovery system which
the adoption of innovative EC PUL fans allows Climaveneta for IT COOLING units
together with Inverter DC brushless to synergistically match both the cooling
compressors (on direct expansion units) and sources of the data center with the heating
an advanced algorithm for balancing the heat requirements inside the building, by moving
loads among the units (including those units the heat from the data center to other areas
that usually remain in stand-by). inside the building.
16/17
16/17
An extended range of chillers with magnetic levitation An advanced free cooling system available both
centrifugal compressors from 200kW, both air source as direct and indirect free cooling (no glycol),
and water source, available also in free cooling and to exploit the outdoor air to cool the data center.
evaporative free cooling versions, to deliver the highest
effiency in every application.
Following the vast experience in using green refrigerants, An advanced algorithm instantaneously detects the
Climaveneta IT Cooling has already employed extensively real thermal loads of indoor units and conveys this
green HFO refrigerants such as HFO1234ze in many information to chiller, to select the most efficient
ranges, in order to continue to be at the forefront of green operating mode.
best practices.
The latest AHR solution with The revolutionary double stage Additional full sensible A significant improvement
2-stage indirect adiabatic design applied to the heat cooling capacity in efficiency thanks to a tight
free-cooling section. exchangers in order to achieve control of the conditioned
pPUE down to 1,025. top level efficiency and pPUE air feeding the servers and
levels down to 1,07. to the addition of more
servers in less volume.
ON / OFF INVERTER
ACCURATE LEGACY Direct expansion close control air conditioners for laboratories
i-AX PRECISE
Direct expansion air conditioners with inverter technology - From 11 to 16,6 kW
w-AV S w-AV DF
Chilled water air conditioners - From 6,7 to 213 kW Chilled water air conditioners with double chilled water coil
From 13,3 to 163 kW
w-AV 2 S/K
2-Section chilled water air conditioners - From 57,8 to 227 kW w-AV 2DF
2-Section chilled water air conditioners with double chilled water coil
w-AV HD S/K
From 63,5 to 243 kW
Chilled water air conditioners for high density
From 15,3 to 183 kW
ACCURATE LEGACY close control air conditioners for high temperatures, high delta T
AV-XT
Chilled water air conditioners with X-type coil technology - From 49,3 to 173 kW
t-AV DL DX
Air cooled direct expansion air conditioners
From 7,6 to 42,6 kW
i-AV DL DX w-AV DL DX
Air cooled direct expansion air conditioners with Chilled water air conditionerstechnology
full DC inverter technology - From 16,2 to 40,5 kW From 11,6 to 41,3 kW
18/19
18/19
CRCX CRCD
Direct Expansion Rack Cooler unit Dual Fluid Rack Cooler unit
From 4,7 to 68,3 kW From 4,5 to 16,7kW
CRCC CRCF
Chilled Water Rack Cooler unit Free Cooling Rack Cooler unit
From 16 to 74,7 kW From 4,6 to 17,5 kW
CRCX ROW
Direct Expansion Rack Cooler unit with integrated compressor
From 14 to 39 kW
a Variable air flow and cooling capacity a Low pPUE index: 1,025
a Fully aluminium structure (20-year warrenty against corrosion) a Modular units
2,/)5((
i-NX-Z TECS2-Z
Chillers with screw compressors and inverter technology Chillers with oil-free inverter compressors
From 32 to 129 kW From 220 to 1324 kW
R 2,/)5((
FX-Z TECS2 HFO-Z
Chillers with screw compressors Chillers with oil-free inverter compressors and HFO refrigerant
From 145 to 1710 kW From 339 to 1017 kW
High efficiency
2,/)5((
NX-W-Z FOCS3-W-Z
Chillers with scroll compressors Chillers with oil-free inverter compressors
From 38 to 398 kW From 241 to 1949 kW
R 2,/)5((
FX-W-Z TECS2 HFO-Z
Chillers with screw compressors Chillers with oil-free inverter compressors and HFO refrigerant
From 124 to 1693 kW From 340 to 1364 kW
2,/)5((
i-FX-W (1+i)-Z TX-W-Z
Chillers with screw compressors and inverter technology Chillers with oil-free inverter compressors
From 468 to 1637 kW From 246 to 4191 kW
20/21
20/21
UTMOST RELIABILITY
NECS-FC-Z FX-EFC-Z
Chillers with scroll compressors and free-cooling technology Chillers with screw compressors and evaporative free-cooling
From 41 to 477 kW technology
From 329 to 1441 kW
FX-FC-Z 2,/)5((
Chillers with screw compressors and free-cooling technology
From 332 to 1450 kW TECS-EFC-Z
Chillers with oil-free compressors and evaporative free-cooling
technology
2,/)5(( From 300 to 1682 kW
TECS-FC-Z
Chillers with oil-free compressors and free-cooling technology
From 302 to 1693 kW
proRZ
Munich, Germany
proRZ is one of the main German general
contractors, which realizes and optimizes
data centers of any size, focusing
on the fulfilment of individual requirements.
Cooling Capacity:
1800 kW
Installed machines:
2x High-efficiency free cooling
Air cooled unit with magnetic
levitation centrifugal compressors
14x Chilled water air conditioners
WIIT Tier IV
2014 Milan, Italy
WIIT is an italian company focused on Private
and Hybrid continuative services, it is one of the
main players in Europe and Worldwide among the
most specialized players in application management
and critical application as disaster recovery and
business continuity.
Cooling Capacity:
700kW
Installed machines:
12X Close Control Air Conditioners
with downflow air delivery equipped
with BLDC scroll compressors
18x Remote condensers
22/23
22/23
FastWeb Tier IV
2014 Milan, Italy
Fastweb, a telecommunications operator,
decided to build a new data center offering
the highest level of security possible to its clients.
Cooling Capacity:
2800 kW
Installed machines:
4x High-efficiency Air cooled unit
with magnetic levitation centrifugal
compressors.
Unipol Tier IV
2015-2016 Bologna, Italy
Unipol is the second largest insurance group on
the italian market and the first in Non-Life business,
classified among the top ten in Europe.
Cooling Capacity:
2300 kW
Installed machines:
4x High-efficiency Air cooled unit
with magnetic levitation centrifugal
compressors
CLIMAVENETA for IT COOLING_05-2018_ENG