Nutribullet RX
Nutribullet RX
USER GUIDE
Downloaded from www.Manualslib.com manuals search engine
IMPORTANT SAFEGUARDS AND
• Do not allow cord to touch hot surfaces, including stove.
• Periodically inspect cord and plug for damage. Do not operate any appliance with
CAUTIONARY INFORMATION a damaged cord or plug. If the appliance malfunctions or is dropped or damaged in
any manner, discontinue use. Contact Customer Service for assistance in obtaining a
SAVE THESE INSTRUCTIONS replacement.
• Do not remove the rubber liner inside the power base. To clean, unplug first, then
FOR YOUR SAFETY, CAREFULLY READ ALL INSTRUCTIONS wipe with a sponge moistened with warm water.
BEFORE OPERATING YOUR NUTRIBULLET Rx.
• THIS APPLIANCE CAN BE USED BY CHILDREN AGED FROM 8
YEARS AND ABOVE AND PERSONS WITH REDUCED PHYSICAL,
MEDICAL WARNING! SENSORY OR MENTAL CAPABILITIES OR LACK OF EXPERIENCE
• IF YOU ARE TAKING ANY MEDICATION, ESPECIALLY CHOLESTEROL-LOWERING AND KNOWLEDGE IF THEY HAVE BEEN GIVEN SUPERVISION OR
MEDICATION, BLOOD THINNERS, BLOOD PRESSURE DRUGS, TRANQUILIZERS, INSTRUCTION CONCERNING USE OF THE APPLIANCE IN A SAFE
OR ANTIDEPRESSANTS, PLEASE CHECK WITH YOUR DOCTOR BEFORE WAY AND UNDERSTAND THE HAZARDS INVOLVED.
CONSUMING ANY OF THE NUTRIBLAST Rx RECIPES.
• IF THE SUPPLY CORD IS DAMAGED, IT MUST BE REPLACED
• THE FOLLOWING LIST OF SEEDS AND PITS CONTAIN CHEMICALS THAT
RELEASE CYANIDE INTO THE BODY WHEN INGESTED. DO NOT USE THE BY THE MANUFACTURER, ITS SERVICE AGENT OR SIMILARLY
FOLLOWING SEEDS AND PITS IN THE NUTRIBULLET Rx: APPLE SEEDS, APRICOT QUALIFIED PERSONS IN ORDER TO AVOID A HAZARD.
PITS, CHERRY PITS, PLUM PITS, PEACH PITS. • DEPRESS POWER BUTTON TO SWITCH OFF THE APPLIANCE
AFTER EACH USE. DISCONNECT FROM POWER SOURCE BEFORE
CHANGING ACCESSORIES OR APPROACHING PARTS THAT MOVE
ELECTRICAL SAFETY IN USE.
hen using any electrical appliance, basic safety precautions should always be
W
observed, including the following: • SHALL WARN OF POTENTIAL INJURY FROM MISUSE, SHALL
STATE THAT CARE SHALL BE TAKEN WHEN HANDLING THE
• CAUTION! TO AVOID RISK OF ELECTRIC SHOCK, NEVER IMMERSE THE CORD, SHARP CUTTING BLADES, EMPTYING THE PITCHER / CUP AND
PLUG, OR POWER BASE OF BLENDER IN WATER OR OTHER LIQUIDS.
DURING CLEANING.
• DO NOT USE THIS PRODUCT WITH ANY TYPE OF ADAPTOR OR VOLTAGE
CONVERTER DEVICE. • CHILDREN SHALL NOT PLAY WITH THE APPLIANCE.
• THE USE OF ATTACHMENTS, INCLUDING CANNING JARS, NOT RECOMMENDED • CLEANING AND USER MAINTENANCE SHALL NOT BE MADE BY
OR SOLD BY MANUFACTURER MAY CAUSE FIRE, ELECTRIC SHOCK, OR INJURY CHILDREN WITHOUT SUPERVISION.
AND VOID THE WARRANTY
• USE OF ADAPTERS AND CONVERTERS IS CONSIDERED AN UNAUTHORIZED
MODIFICATION OF THE PRODUCT AND AS SUCH WILL VOID THE WARRANTY.
USE OF THIS PRODUCT IN LOCATIONS WITH DIFFERENT ELECTRICAL
SPECIFICATIONS MAY RESULT IN DAMAGE TO THE PRODUCT.
WARNING: VENTILATION CAUTION
• Always operate the NUTRIBULLET on level surface, leaving unobstructed
• UNPLUG THE NUTRIBULLET Rx AND DEPRESS POWER BUTTON WHEN IT IS NOT space beneath and around the power base to permit proper air circulation. Slots
IN USE. MAKE SURE THE POWER BASE IS UNPLUGGED BEFORE ASSEMBLING, and openings on the bottom of the product are provided for ventilation to ensure
DISASSEMBLING, ADDING ADDITIONAL PARTS, OR CLEANING. reliable motor operation and to prevent over-heating. Warning: To prevent fire
hazard, power base openings should be free of dust or lint and never obstructed
• Do not pull, twist, or damage the power cord. with flammable materials such as newspapers, tablecloths, napkins, dishtowels,
• Do not allow the cord to hang over the side of the counter or table. or place mats.
2 3
4 5
6 7
STUBBORN CLEANUP
• If ingredients dry inside the NutriBullet Rx Cups or SouperBlast Pitcher, make
your cleanup a snap by filling the cup about 2/3 full with warm soapy water and
screw on the Extractor Blade and if using the SouperBlast Pitcher, put on
lids. Place the cup assembly on the NutriBullet Rx Power Base for about 20-30
seconds. That will loosen the stuck ingredients, and with a light scrub and rinse,
you’ll be all done.
10 11
1
Power Base to start another SMART Technology cycle. Do not repeat more
Add ingredients into one of the cups. than 3 consecutive cycles resting 15 seconds between cycles. If you press
the green G-button for 2 seconds and the light turns RED, you have switched
2
Fill with liquid up to the Max Line. Then, twist the in SouperBlast Mode. Simply lift the cup off the Power Base at any time to
Extractor Blade onto the cup and tighten by hand to MAX exit this mode or press the power button, located 90˚ to the left side of the
make sure the vessel is sealed. LINE
G-button. When the vessel is removed from the power base, only the G-button
light will turn off. When the power off button is pressed, the BLUE light will turn
3
Plug the power base into an electrical outlet. Press off and the blade will stop spinning. Always press the power off button upon
the power button, located 90˚ to the left side of the completion of processing.
G-button, to turn the machine on. The power button
light will glow BLUE, signifying power. Next, place
• NOTE: IF AT ANY TIME THE G BUTTON IS PUSHED FOR 2 SECONDS, THE BUTTON
the cup blade-side-down onto the power base. This
WILL TURN RED AND INITIATE SOUPERBLAST MODE.
will activate the NutriBullet Rx’s SMART Technology
• WHEN EXTRACTING OIL BASED OR STICKY FOODS, REFER TO INSTRUCTIONS
function, causing the G-Button at the front of the LISTED UNDER TAP TECHNIQUE ON PAGE 19.
unit to glow GREEN, and initiating the 1-minute • DO NOT TOUCH COUPLING GEAR DIRECTLY WITH HANDS AFTER NUTRIBLAST
extraction cycle. MODE! THE COUPLING GEAR IN BLADE BASE AND POWER BASE WILL BE HOT!
4
When the cycle has completed and the GREEN
light has turned off, turn off the unit by depressing • TO TURN OFF THE MACHINE AT ANYTIME DURING THE NUTRIBLAST CYCLE (G
the power button, located 90˚ to the left side of BUTTON WILL BE GREEN), PRESS THE POWER BUTTON, LOCATED 90˚ TO THE
the G-button. The BLUE light will stop glowing, LEFT SIDE OF THE G-BUTTON OR LIFT THE CUP OFF THE POWER BASE.
signifying the power is off. POWER BUTTON
14 15
2
A dd ingredients into the SouperBlast Pitcher and AND COUPLING GEAR WILL BE HOT! DO NOT TOUCH DIRECTLY WITH HANDS! ALWAYS USE
securely attach the vented, 2-piece lid SouperBlast HEAT RESISTANT PADS TO GRASP THE HANDLE AND TO SUPPORT THE BOTTOM OF THE
Pitcher Lid. SOUPERBLAST PITCHER.
• IF YOU DESIRE SOUP TO BE HOTTER OR YOU WISH TO RE-HEAT SOUP, TRANSFER
3
P lug the power base into an electrical outlet. Press FIRST TO AN APPROPRIATE MICROWAVE SAFE CONTAINER OR STOVE TOP POT
the power button located 90˚ to the left side of the AND HEAT SEPARATELY—DO NOT REHEAT IN THE NUTRIBULLET Rx.
G-button, to turn the machine on. Next, place the
cup blade-side-down onto the power base. This will
• TO TURN OFF THE MACHINE AT ANYTIME DURING THE SOUPERBLAST CYCLE (G
activate the NutriBullet Rx’s SMART Technology BUTTON WILL BE RED), PRESS THE POWER OFF BUTTON, LOCATED 90˚ TO THE
function, causing the G-Button at the front of the unit LEFT SIDE OF THE G-BUTTON OR LIFT THE SOUPERBLAST PITCHER OFF THE
to glow GREEN. POWER BASE.
4
P ress the GREEN G-Button down for 2 seconds
until it glows RED. This will indicate that
SouperBlast Mode has begun. The unit will run
in SouperBlast Mode for about 7 minutes before
automatically turning off, causing the ingredients
inside the SouperBlast Pitcher to heat up to about
70 degrees Celsius/150 degrees Fahrenheit. The
unit is programmed to slow down twice during the
7-minute cycle to allow ingredients to settle for
improved processing. This is normal.
16 17
1
ingredients are having a hard time making it down to the blade, simply use the
Shake technique. Take the cup and blade assembly off the Power Base
and Tap the cup and blade assembly on the counter
to force the ingredients down into the blades.
from the Power Base.
2
Place the cup and blade assembly onto the
Power Base and finish processing.
2
With the cup and blade assembly in
hand, shake it like a cocktail shaker.
Then put it back on the Power Base.
ALLOW MACHINE TO COOL DOWN FOR 10 MIN AFTER 4-5 CYCLES TO PREVENT
OVERHEATING AND DAMAGING THE UNIT.
18 19
CLEANING SAFEGUARDS
• AFTER MAKING A NUTRIBLAST OR SOUPERBLAST, THE BLADE MUST BE
CLEANED IMMEDIATELY
• ALWAYS UNPLUG POWER BASE AND DEPRESS THE THE POWER BUTTON PRIOR
TO CLEANING, ASSEMBLING OR DISASSBMBLING.
• NEVER SUBMERGE THE POWER BASE IN WATER OR PLACE IT IN THE
DISHWASHER. WIPE OFF ANY DEBRIS INSIDE THE POWER BASE IMMEDIATELY
TO KEEP IT IN GOOD WORKING ORDER.
• DO NOT WASH THE BLADES IN THE DISHWASHER AS ELEVATED
STUBBORN CLEANUP TEMPERATURES CAN DAMAGE GASKET SEALS.
If ingredients dry inside the NutriBullet Rx Cups or SouperBlast Pitcher, make your • THE NUTRIBULLET Rx CUPS CAN BE WASHED IN THE DISHWASHER AND
cleanup a snap by filling the cup about 2/3 full with warm soapy water and screw SHOULD BE WASHED ON THE TOP RACK OF THE DISHWASHER USING THE
on the Extractor Blade and if using the SouperBlast Pitcher, put on lids. Place the NORMAL (NOT SANITIZE) CYCLE.
cup assembly on the NutriBullet Rx Power Base for about 20-30 seconds. That will • THE NUTRIBULLET Rx CUPS AND BLADES SHOULD NOT BE EMERSED IN
loosen the stuck ingredients, and with a light scrub and rinse, you’ll be all done. BOILING WATER FOR ANY REASON AS THIS WILL WARP PLASTIC AND
DAMAGE GASKETS.
• BLADES ARE SHARP! USE CARE WHEN CLEANING BLADES TO AVOID INJURY!
CLEANING THE NUTRIBULLET POWER BASE RINSE BLADES IMMEDIATELY AFTER EACH USE TO PREVENT DEBRIS FROM
For the most part the Power Base doesn’t really get dirty, but if you neglect to twist the DRYING AND STICKING TO BLADE COMPONENTS. IF NECESSARY, USE
blade on to the cup tightly, liquids can leak out and get into the base and INCLUDED BRUSH TO LOOSEN AND DEBRIS AROUND BLADES, GASKETS AND
activator buttons. BLADE HOUSING THREADS WITH CARE.
Here’s how to clean it up. • HANDWASH ONLY WITH MILD DISH SOAP AND WARM WATER (NOT HOT).
Step 1: The most important thing is to depress the power button and UNPLUG the • DRY IMMEDIATELY.
Power Base before! • FOR TOUGH DEBRIS, FILL THE CUP ½ FULL WITH WARM (NOT HOT), MILD
Step 2: Use a damp rag to wipe down the inside and outside of the Power Base. SOAPY WATER. THEN, SIMPLY TWIST ON THE BLADE, POP IT ON THE BASE
• NEVER SUBMERGE THE POWER BASE IN WATER OR PLACE IT IN AND GIVE IT A RUN FOR 30-45 SECONDS. FOLLOW UP WITH A QUICK BRUSH.
THE DISHWASHER. • WHEN WASHING BLADES, DO NOT ATTEMPT TO REMOVE THE GASKET RING.
• Never put your hands or utensils near the moving blade and never use your SIMPLY HAND WASH THE BLADES IN WARM, MILD SOAPY WATER. ATTEMPTED
hands or utensils to press the activator buttons down while the Power Base REMOVAL OF THE GASKET MAY PERMANENTLY DAMAGE THE BLADE
is plugged in. CONFIGURATION AND CAUSE LEAKAGE.
20 21
CUP! MAKE SURE YOUR leafy greens or, mix and match! Fill the
INGREDIENTS AND LIQUID (2 cups = 1 serving) Romaine
Tall Cup up to 50% with leafy greens.
Spinach
REACH NO HIGHER THAN Work up to 2 full cups (2 handfuls) of
Spring Greens
leafy greens per Blast.
THE MAX LINE.
TIP: We recommend using frozen fruits such as berries or bananas if you desire
a frosty NUTRIBLAST.
22 23
24 25
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
26 27
The power, speed, heating capabilities and unique design of the NUTRIBULLET Rx
make it easier than ever to maximize your daily intake and absorption of vegetables,
fruits, nuts, seeds, and other superfoods...the very foods that have been scientifically
proven to reduce mortality when consumed and absorbed in abundance.
Join the millions of NutriBullet users who have transformed their health with the
power of extracted nutrition, aka “nature’s prescription” to look and feel better
than they ever thought possible.