Schneider MiCOM P642 B1 Transformer PTT User Manual ENU
Schneider MiCOM P642 B1 Transformer PTT User Manual ENU
Schneider MiCOM P642 B1 Transformer PTT User Manual ENU
OMICRON PTL
User Manual
V1.000
Content
1. General ............................................................................................................................................ 3
1.1 Supported Relays........................................................................................................................... 3
2. Software and Hardware Requirements........................................................................................... 3
3. Hardware ......................................................................................................................................... 4
4. Functional Range ............................................................................................................................ 5
5. XRIO Converter ............................................................................................................................... 6
1. General
This user manual describes details of testing MiCOM P642 relay with the OMICRON
Protection Test Template. General information on the usage of OMICRON Protection Testing Library
items can be found in the OMICRON PTL user manual.
A CMC test set with six current outputs is required. A CMA 156 current amplifier may be additionally
required for testing with higher currents e.g. relays with 5A current measuring inputs.
3. Hardware
There are multiple possibilities of wiring a MiCOM P642 relay to a CMC test set. The advised connections
are shown in Figure 1. These connections are the default settings in the Hardware Configuration of the
PTT.
Figure 2: Connection diagram for testing Earth Fault protection side 1 (EF Input “Measured”, TN1)
Figure 3: Connection diagram for testing Earth Fault protection side 2 (EF Input “Measured”, TN2)
4. Functional Range
Supported functions:
Differential Protection (87)
Phase Overcurrent Protection (50, 51)
Earth Fault Overcurrent Protection (50N, 51N)
5. XRIO Converter
The Test Object already contains the Schneider MiCOM P642 XRIO Converter, which includes setting
parameters of the modelled protection relay. The setting parameters are built as an image of the Easergy
Studio V6.0.0 software and the following data models with software version:
P642: Software Version B1
The XRIO Import Filter can be used for importing settings into the Relay Parameter Section.
Note: The MiCOM P642 PTT works with settings in secondary values. Please ensure that the parameter
Setting Values (PARAMETER_09_2E) is set to Secondary before exporting to XRIO from the MiCOM
S1 Agile SW.