HC-BD Sgs Test Report PDF
HC-BD Sgs Test Report PDF
HC-BD Sgs Test Report PDF
No. : GZIN2007039756MR
Date : Aug 11, 2020
Page: 1 of 8
CUSTOMER NAME: GUANG ZHOU HUI CHI GLASS TECHNICAL CO., LTD.
ADDRESS: 2ND LIKANG INDUSTRIAL SHITAN ROAD SHIJING BAIYUN DISTRICT
510430 GUANGZHOU
Signed for
SGS-CSTC Standards Technical
Services Co., Ltd. GZ Branch Testing
Center
Kelly Lee
Authorized signatory
TEST REPORT
No. : GZIN2007039756MR
Date : Aug 11, 2020
Page: 2 of 8
Summary of Results:
No. Test Item Test Method Result Conclusion
With reference to
ASTM D3330/D3330M-
1 180º Peel Strength 121N/10mm /
04(2018) Method A and
client's requirement
ASTM D1003-13
2 Haze 1.1% /
Procedure A
Tensile
27.0MPa
Strength
3 Tensile Test ASTM D638-14 /
Elongation
610%
at Break
Total Luminous ASTM D1003-13
4 91.2% /
Transmittance Procedure A
Test Result:
Note: The result was maximum peel force/specimen width.The result was for reference only as the
adhesive transfer.
Test Photo:
Equipment Information:
Next Calibration
Equipment Model Equipment No. Calibration date
date
Universal Testing
Z010 GZMR-PL-E109 2020-07-17 2021-07-16
Machine
C Haze 1.1%
.
TEST REPORT
No. : GZIN2007039756MR
Date : Aug 11, 2020
Page: 5 of 8
Test Photo:
Equipment Information:
Next Calibration
Equipment Model Equipment No. Calibration date
date
Hazemeter NDH5000 GZMR-PL-E083 2019-11-14 2020-11-13
Test Result:
Note:
1. Test specimens were cut from the sample.
2. The release paper of test specimens was ripped off before test.
Test Photo:
Equipment Information:
Next Calibration
Equipment Model Equipment No. Calibration date
date
Universal Testing
CMT6103 GZMR-PL-E022 2019-09-04 2020-09-03
Machine
Test Photo:
Equipment Information:
Next Calibration
Equipment Model Equipment No. Calibration date
date
Hazemeter NDH5000 GZMR-PL-E083 2019-11-14 2020-11-13