SCHOOL OF CHEMICAL & MATERIALS ENGINEERING

NATIONAL UNIVERSITY OF SCIENCES & TECHNOLOGY, ISLAMABAD


Course Title: Heat Transfer Course Code: CHE-242
Assignment 2 (Spring 2024) Instructor: Dr. Waheed Miran
Name: _______________________________ Reg. # ____________________________Total Marks: 10

Q1. Apply the concept of effectiveness of heat exchanger and number of transfer units (NTU) 4+3+3 (CLO2, C-3)
to derive the relation for NTU Effectiveness for Counter Flow heat exchanger.
Q2. Student’s assignment:

Muhammad Imran
Zainab Rahman
Ubaid Ur Rehman
Maaz Nadeem
Laeeqa Aslam Chaudhry
Muhammad Usama Bin Asif
Usman Murtaza
Allah Ditta
Ammara Asif
Ahmed Hassan
Zara Khan
m2.K, respectively. Solve for the (1) Overall heat transfer coefficient (2) Surface area for both Muhammad Umair
parallel and series arrangement.

Q1. Hot oil is to be cooled by water in a 1-shell-pass and 8-tube-passes heat exchanger. The 4+3+3 (CLO2, C-3)
tubes are thin-walled and are made of copper with an internal diameter of 1.4 cm. The length of
each tube pass in the heat exchanger is 5 m, and the overall heat transfer coefficient is 310 W/m2 Student’s assignment:
· °C. Water flows through the tubes at a rate of 0.2 kg/s, and the oil through the shell at a rate of
0.3 kg/s. The water and the oil enter at temperatures of 20°C and 150°C, respectively. Solve for Abdul Muqeet
the rate of heat transfer in the heat exchanger and the outlet temperatures of the water and the Malik Salal
oil. Rabia Waheed
Ali Ahmed Zaki
Q2. Water (Cp _ 4180 J/kg · °C) enters the 2.5-cm internal-diameter tube of a double- Malika Khan
pipe counter-flow heat exchanger at 17°C at a rate of 3 kg/s. It is heated by steam Fatima Saleem
condensing at 120°C (hfg _ 2203 kJ/kg) in the shell. If the overall heat transfer coefficient Tehreem Sajid
of the heat exchanger is 1500 W/m2 · °C, solve for the length of the tube required in Anas Attiq
order to heat the water to 80°C. Arham Naseem Khan
Talha Gulzar
Syeda Fatima Hashim
Ajmal Munir
SCHOOL OF CHEMICAL & MATERIALS ENGINEERING
NATIONAL UNIVERSITY OF SCIENCES & TECHNOLOGY, ISLAMABAD
Course Title: Heat Transfer Course Code: CHE-242
Assignment 2 (Spring 2024) Instructor: Dr. Waheed Miran
Name: _______________________________ Reg. # ____________________________Total Marks: 10

Q1. Water (Cp = 4180 J/kg · °C) is to be heated by solar heated hot air (Cp = 1010 J/kg 4+3+3 (CLO2, C-3)
· °C) in a double-pipe counterflow heat exchanger. Air enters the heat exchanger at 90°C
at a rate of 0.3 kg/s, while water enters at 22°C at a rate of 0.1 kg/s. The overall heat
transfer coefficient based on the inner side of the tube is given to be 80 W/m2 · °C. The Student’s assignment:
length of the tube is 12 m and the internal diameter of the tube is 1.2 cm. Determine the
outlet temperatures of the water and the air. Rida Fatima Irfan
Mahnoor Ayesha .
Zikias Ali Rao
Q2. Cold water (Cp _ 4180 J/kg · °C) enters the tubes of a heat exchanger with 2-
Hamzah Kamran
shell passes and 20–tube passes at 20°C at a rate of 3 kg/s, while hot oil (Cp _ 2200
Abdullah Kamran
J/kg · °C) enters the shell at 130°C at the same mass flow rate and leaves at 60 °C.
Muhammad Noor Ul Hassan .
If the overall heat transfer coefficient based on the outer surface of the tube is 300
Faizan Bakht
W/m2·°C, solve for (a) the rate of heat transfer and (b) the heat transfer surface area
Hifza Amjad
on the outer side of the tube.
Muhammad Zeeshan Akhtar
Mughal
Muhammad Adil Bin Safdar

Q1. A thin-walled double-pipe parallel-flow heat exchanger is used to heat a chemical 4+3+3 (CLO2, C-3)
whose specific heat is 1800 J/kg · °C with hot water (Cp _ 4180 J/kg · °C). The chemical
enters at 20°C at a rate of 3 kg/s, while the water enters at 110°C at a rate of 2 kg/s. The Student’s assignment:
heat transfer surface area of the heat exchanger is 7 m2 and the overall heat transfer
Ali Muaz
coefficient is 1200 W/m2 · °C. Apply the concept of e-NTU and determine the outlet
Dure E Adan Zaib
temperatures of the chemical and the water.
Muhammad Masood Farid
Muhammad Zaid Amjad
Q2. In a countercurrent-flow heat exchanger, 1.25 kg/s of benzene (specific heat 1.9 kJ/kg K and
Hafsa Jalil
specific gravity 0.88) is to be cooled from 350 to 300 K with water at 290 K. In the heat
exchanger, tubes of 25 mm external and 22 mm internal diameter are employed and the water Abdul Rehman
passes through the tubes. If the film coefficients for the water and benzene are 0.85 and 1.70 Haisum Tahir
SCHOOL OF CHEMICAL & MATERIALS ENGINEERING
NATIONAL UNIVERSITY OF SCIENCES & TECHNOLOGY, ISLAMABAD
Course Title: Heat Transfer Course Code: CHE-242
Assignment 2 (Spring 2024) Instructor: Dr. Waheed Miran
Name: _______________________________ Reg. # ____________________________Total Marks: 10

kW/m2 K respectively and the scale resistance can be neglected, Solve for total length of tube Ali Raza
will be required if the minimum quantity of water is to be used and its temperature is not to be Masood Ahmed
allowed to rise above 320 K? Usman Ali
Muhammad Usama
Hafsa Arif
Q3.

Derive from Stefan Boltzmann Law and show that