MPAC128-MPAC128ATEX DS en V01

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

MPAC128 Series

Acoustic Imager

„ 128 Microphone array


„ Detection frequency up to 48 kHz
„ Detection range up to 120 m
„ 8 MP optical camera resolution
„ 7” screen
„ Intelligent Analytics
„ Ultrasonic monitoring

DESCRIPTION FEATURES
MPAC128 Series: Cutting-Edge Gas Leak Detection „ Detects multiple gas types and pressurised gas leaks
with ease.

MPAC128: Locate gas leaks and partial discharge threats „ Simple operation with only two parameters to set.
swiftly and precisely with Megger’s MPAC128. Equipped „ Provides leak rate quantification for cost estimation.
with 128 sensors, this high-resolution acoustic imager „ Phase Resolved Partial Discharge (PRPD) for discrimination
enables clear visualisation of gas, pressure, and vacuum between different types of partial discharge.
leaks, as well as electrical partial discharge from safe „ Focus function reduces unwanted noise in noisy
distances up to 120 meters away. With an IP54 rating, environments.
it ensures accurate targeting for repairs, preventing safety
„ Converts ultrasonic monitoring sounds to audible sounds
hazards, production disruptions, and losses, ultimately
for pinpointing leaks.
saving valuable time, energy, and resources.
The MPAC128 series also packs impressive reliability with „ Expandable storage for storing results, images, and
the units ingenious self-check function, meticulously videos on site.
verifying internal components’ integrity and guaranteeing „ Easy update firmware to latest version via the USB-C
flawless operation of the microphone array, providing memory stick or microSD card.
unwavering performance day in, day out. „ Free Acoustic Analysis software.

The MPAC128-ATEX is designed for hazardous With the MPAC128 series, experience unparalleled
Zone 2 areas, and provides ATEX-certified safety without precision and efficiency in gas leak detection, aid
compromising performance. Identifying gas, pressure, maintenance planning and prevention of catastrophic
and vacuum leaks, as well as corona, arcing, and partial events, ensuring safety and reliability in various industrial
discharge faults up to 120 meters away, including applications.
challenging areas, this model ensures prompt action to
restore safety and system integrity in finished products,
process plants, and electrical installations.

www.megger.com 1
MPAC128 Series
Acoustic Imager
„ Detection frequency: 2 kHz to 48 kHz Camera
Camera Focal Length 3.04 mm fixed focal length
„ Detection range: 0.3 to 120 m
Camera Image
„ Optical camera resolution: 8 megapixels Field of View (FOV) Horizontal: 62°
„ Leak detection rate: Vertical: 48°

„ 1 m 7 bar 0.37 ml/s Saved Picture Zoom Manual


Resolution 8 megapixels
„ 10 m 7 bar 0.7 ml/s
„ Microphones in array: 128 Display
Resolution 1024 x 600
„ Sound image field of view
Size 7 inches
Horizontal: 62°
Brightness Adjustable
Vertical: 48°
Touchscreen Capacitive touch screen
„ Meets IP54
Standard palettes Grayscale, Ironbow, Rainbow

SPECIFICATIONS Storage
Internal Storage 8 GB
Ease Of Use Intuitive user interface and
Storage capacity subject to change
touch screen
based on software version
Trend Graphs Frequency and dB scale
Image Format JPG
Cursor information dB level reading at centre point of
Audio Format WAV
the image
Video Format mp4
Supported Languages English, Dutch, French, Chinese,
German, Hungarian, Italian, Japanese, Video Length 5 min
Korean, Norwegian, Polish, Digital Export microSD card/USB-C memory stick
Portuguese, Russian, Spanish,
Swedish Battery
Battery Capacity 6600 mAH, 7.2 V Rechargeable Li-ion
Sensors
Microphone Array 128 channels MEMS microphone Battery Life ~ 4 hours under full load state

Frequency Band 2 kHz to 48 kHz Charge USB Type-C port

Dynamic Range 0.5 dB to 12 dB (user adjustable) Output: USB-C 5.0 V 3.0 A.

Sound Image Rated input: 100 240 VAC,


Field of View (FOV) Horizontal: 62° 50/60 Hz, 1.2 A
Vertical: 48° Power Consumption 29 W max
Nominal Frame Rate 25 fps (min) Energy management User selectable Sleep/Auto power off
Note: frames per second is a measure
of how quickly the image on the Environmental
screen is refreshed each second. Operating Temperature -20 ºC to +50 ºC
Test Sound Pressure Relative Humidity 10% to 95% (no condensation)
Level Range 25.7 dBA to 132.5 dBA
Storage Temperature -20 ºC to +60 ºC
Acoustic measurements Charging Temperature 10 ºC to +45 ºC
Detect distances 0.3 m to 120 m Restriction of
Leak detection rate 1 m 7 bar 0.37 ml/s Hazardous Substances
(RoHS) Compliant Yes
10 m 7 bar 0.7 ml/s
Number of digits 24-bit Mechanical
Auto max/min dB gain User-selectable, minimum Colours MPAC128: Grey, Black and White
test bandwidth 1 kHz MPAC128-ATEX: Grey, Black and Red
Size 272 x 174 x 42 mm
Weight 1.7 kg
Ingress Protection (IP) IP54
Warranty 2 years

www.megger.com 2
MPAC128 Series
Acoustic Imager
Safety
General Safety IEC 61010-1
Electromagnetic
Compatibility (EMC)
International IEC 61326-1: Portable
Electromagnetic Environment
IEC 61326-2-2
CISPR 11: Group 1, Class A
ATEX IEC 60079-0, IEC 60079-11
II 3G Ex ic IIC T5 Gc

Software
Report types Gas/Electricity, ISO 50001-compliant
Analysis Waveform, spectrum, spectrogram,
leakage assessment, discharge type
discrimination

ORDERING INFORMATION
Description Part number Description Part number
MPAC128-ATEX acoustic imaging camera 1015-885 Included accessories
MPAC128 acoustic imaging camera 1015-886 Hand straps
Shoulder strap
Universal mains charger
USB-C charge cable
Headphone
Protective box
8 GB microSD card
USB-A microSD card reader
8 GB USB-C/USB-A memory stick
Cleaning tool

SALES OFFICE MPAC128-MPAC128ATEX_DS_en_V01


Megger Limited www.megger.com
Archcliffe Road Dover ISO 9001
CT17 9EN England The word ‘Megger’ is a registered trademark
T. +44 (0) 1304 502101
E. [email protected]

You might also like