RETROFIT AND UPGRADE SERVICES

3rd party LCI drive


with SINAMICS CU320-2
Answer all LCI drive challenges with a single upgrade
siemens.com/lda-services

Today, many operators are faced with operative challenges like the discontinuation of the drive
product and the service assistance, or the risk of failures during operation caused by equipment
age and wear, and the lack of spare parts. In addition, equipment obsolescence often increases
the price of spare parts, and the outdated systems are not compatible with digitalization. On the
other hand, there is often a lack of funds to invest in a new VFD, combined with uncertainty about
production or performance failures when installing and commissioning a new drive. All this calls
for a comprehensive solution: a LCI control upgrade kit with SINAMICS CU320-2.

Convincing value-adds

Availability and reliability Cost advantage Sustainability


A SINAMICS CU320-2 control upgrade extends Compared to a new 3rd party drive A SINAMICS CU320-2 control upgrade concen-
the availability and reliability of your LCI drives, and depending on the installed power, trates on changing the parts that need to be
as well as plant operation and spare parts a SINAMICS CU320-2 control upgrade replaced and keeping materials and equipment
supply chain. is up to four times more cost-efficient. suitable for further use in place.
Transparent and efficient project execution
Execution line

1. Identify 2. Preliminary 3. Assessment, 4. Order 5. On-site


3rd party data engineering implemen­ execution and
LCI drives collection and offering tation Field Services

Available for thyristor- Initial checklist for first After a personal assess- Manufacturing starts with Installation of the new
based load commutated analysis through Siemens ment, Siemens Engineering the final design and the control set and its
converters driving engineering prepares a technical offer preparation of the bill of additio­nal components,
synchronous motors with the final control materials. After material followed by recommissio­
system modernization receipt, control cabinet ning to configure the
concept, the content of the and additional components equipment accordingly.
technical packages, and are assembled and finally
the schedule for execution. tested (FAT optional).

Benefits for our customers


With a SINAMICS CU320-2 control unit upgrade kit, your operating assets can
tap the latest technology standards, and provide you with clear advantages.

Buy what you need Optional LCI drive retrofit


A SINAMICS CU320-2 control unit upgrade Should the initial analysis show that your Published by
Siemens AG
always is a customized solution, and ranges whole LCI drive needs replacement, we can
from partial retrofits to complete drive offer a retrofit of the entire system after a Large Drives Applications
Vogelweiherstr. 1–15
replacements, allowing you to choose and compatibility evaluation. With this you profit
90411 Nuremberg
plan the best approach for your requirements. from many advantages: Germany

Bridge the digitalization gap • Comprehensive solution from a single For the U.S. published by
With the implementation of the new source; no interface problems
Siemens Industry Inc.

SINAMICS CU320-2 control unit, the assets • Reliable solution: All LCI drives are config- 100 Technology Drive
in operation will be digitally enabled so that ured by experienced Siemens specialists Alpharetta, GA 30005
United States
SIDRIVE IQ-based services can be implemented. • Speedy implementation: All field service
personnel are trained and qualified TH S82-220528 DA 1022
Enjoy highest cyber security
© Siemens 2022
As LCI drives are often used in mission-critical specialists
assets, the proven, certified Siemens cyber • Short project lead times: fast commis-
security standards are part of the upgrade sioning, minimized production losses
package. • Secured spare parts supply for years
to come
Changes and replacements
on 3rd party LCIs
• Control unit cabinet
• Measuring related components Subject to changes and errors.
The information given in this document
• Thyristors gate units Upgrade and retrofit scope of supply only contains general descriptions and/or
performance features which may not
• Excitation unit • Hardware package always specifically reflect those described,
or which may undergo modification in the
• Software engineering course of further development of the
products. The requested performance
Additional highlights: • Test of the upgraded software features are binding only when they are
expressly agreed upon in the concluded
• No changes to the drive dimensions • Project management contract.

• No external cable adaptations • Field service execution (optional) All product designations may be trade-