19.1 Inputting - Outputting Data

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

19.

MAINTENANCE FUNCTION

19.1 Inputting/Outputting Data


The main CPU memorized the following data.
Outputting the data I/O device while the CNC is running normally
(1) CNC parameter
(2) PMC parameter
(3) Pitch error compensation amount
(4) Custom macro variable values
(5) Tool compensation amount
(6) Part program (machining program, custom macro program)

19.1.1 Parameters required for data input/output


NOTE Note that data may not be output in the alarm state.
Parameters required for input/output are as follows :
In addition, l indicates the standard setting for input/output devices made
by FANUC. Change these settings according to the unit you actually use.
(Parameter can be changed in MDI mode or emergency stop status.)
#7 #6 #5 #4 #3 #2 #1 #0
0000 ISO

#1 (ISO) 0 : Output with EIA code


1 : Output with ISO code (FANUC cassette)

0020 Selection of I/O channel

l 0 : Channel 1 (JD36A of mother board)


1 : Channel 1 (JD36A of mother board)
2 : Channel 2 (JD36B of mother board)
3 : Channel 3 (JD38A of serial communication board)
4 : Memory card interface
NOTE An operation example shown here assumes that data input/output
is performed with an input/output unit connected to the JD36A. (I/O
channel = 0)
#7 #6 #5 #4 #3 #2 #1 #0
0101 NFD ASI SB2

#0 (SB2) 0 : No. of stop bits is 1.


l 1 : No. of stop bits is 2.
#3 (ASI)l 0 : EIA or ISO code is used for input/output data.
1 : ASCII code is used.
#7 (NFD) 0 : Feed is output when data is output.
1 : Feed is not output when data is output.

890
19. MAINTENANCE FUNCTION

0102 Specification number of input/output device

Set value Input/output device


0 RS–232–C (Used control codes DC1 to DC4)

1 FANUC CASSETTE ADAPTOR 1 (FANUC CASSETTE B1/ B2)

2 FANUC CASSETTE ADAPTOR 3 (FANUC CASSETTE F1)

3 FANUC PROGRAM FILE Mate, FANUC FA Card Adaptor


FANUC FLOPPY CASSETTE ADAPTOR, FANUC Handy File
FANUC SYSTEM P-MODEL H

4 RS–232–C (Not used control codes DC1 to DC4)

5 Portable tape reader

6 FANUC PPR
FANUC SYSTEM P-MODEL G, FANUC SYSTEM P-MODEL H

0103 Baud Rate

1: 50 5: 200 9: 2400
2: 100 6: 300 l10: 4800
3: 110 7: 600 11: 9600
4: 150 8: 1200 12: 19200 [BPS]

19.1.2 Output of data

* In the alarm state, data output is disabled in some cases.

19.1.2.1 Outputting CNC parameters


1. Enter EDIT mode or the emergency stop condition.

2. Press SYSTEM
key and soft key [PARAM] to display parameter screen.

3. Press soft key [(OPRT)] ,and soft key .


4. Press soft key [PUNCH] and [EXEC],and the parameters are started to
be output.

19.1.2.2 Outputting PMC parameters


1. Select MDI mode.

2. Press SETTING
OFFSET
key then soft key [SETTING] to select a setting screen.

3. Set the cursor to PARAMETER WRITE and input 1 and INPUT


. At
this time, alarm 100 will be generated.

4. Press SYSTEM
key and soft key [PMC].

5. Press soft key [PMCPRM] and soft key [KEEPRL]


6. Set the cursor to K900 (on the SB7) or K17 (on the SA1) and set the first
bit to 1.

X X X X X X 1 X INPUT

Where, mark x is a former value


Thus, data input/output screen has been selected.
7. Select EDIT mode.
891