1. 290 For the concrete column shown below, b = 250 mm, h =
400 mm, d' = 65 mm. The column is reinforced with 6-25 mm diameter rebar with fy = 415 MPa. F'c = 27 MPa
What is the balanced eccentricity?
2. 1794 For the concrete column shown below, b = 250 mm, h =
400 mm, d' = 65 mm. The column is reinforced with 6-25 mm diameter rebar with fy = 415 MPa. F'c = 27 MPa
What is the ultimate axial design capacity of the column in
kN?
3. 965.8 For the concrete column shown below, b = 250 mm, h =
400 mm, d' = 65 mm. The column is reinforced with 6-25 mm diameter rebar with fy = 415 MPa. F'c = 27 MPa
What is the total compressive force (nominal) in concrete
under balanced condition?
4. 2760 For the concrete column shown below, b = 250 mm, h =
400 mm, d' = 65 mm. The column is reinforced with 6-25 mm diameter rebar with fy = 415 MPa. F'c = 27 MPa
What is the nominal axial load capacity of the column in
kN?
5. 76.08 A precast concrete beam T-beam has a flange width of
600 mm, flange thickness of 100 mm, width of 300 mm, effective depth of 580 mm, and a total depth of 600 mm. Use f;c = 21 MPa and fy = 415 MPa. The section is reinforced with 4-25 mm bars in tension.
Calculate the depth of the compression block in mm.
6. 0.0164 A precast concrete beam T-beam has a flange width of
600 mm, flange thickness of 100 mm, width of 300 mm, effective depth of 580 mm, and a total depth of 600 mm. Use f;c = 21 MPa and fy = 415 MPa. The section is
1/5 CIVINCO KCQ8 Study online at https://quizlet.com/_dial03 reinforced with 4-25 mm bars in tension.
Compute for the strain in tension steel
7. 52.20 A precast concrete beam T-beam has a flange width of
600 mm, flange thickness of 100 mm, width of 300 mm, effective depth of 580 mm, and a total depth of 600 mm. Use f;c = 21 MPa and fy = 415 MPa. The section is reinforced with 4-25 mm bars in tension.
If the beam is 8 m long, find the maximum concentrated
service liveload at midspan that can be supported by the beam if it already carries a total service uniform load of 24 kN/m. Use 1.2DL+1.6LL.
8. 0.02573 A reinforced concrete beam has a width of 300mm and an
effective depth of 618mm. Compressive reinforcement (if required) will be placed at d'=60mm. f=25MPa and f=415 MPa. The beam is to support a factored bending moment of 520 kN-m. Æ=0.90. Use 2012/2015 NSCP.
Calculate the steel ratio for balance section, Pb.
9. 0.01409 A reinforced concrete beam has a width of 300mm and an
effective depth of 618mm. Compressive reinforcement (if required) will be placed at d'=60mm. f=25MPa and f=415 MPa. The beam is to support a factored bending moment of 520 kN-m. Æ=0.90. Use 2012/2015 NSCP.
Determine the governing steel ratio (p) following NSCP
requirements.
10. 4 pcs A reinforced concrete beam has a width of 300mm and an
effective depth of 618mm. Compressive reinforcement (if required) will be placed at d'=60mm. f=25MPa and f=415 MPa. The beam is to support a factored bending moment of 520 kN-m. Æ=0.90. Use 2012/2015 NSCP.
Determine the maximum number of 25mmØ bars that can
be used for given section if it is singly-reinforced. 2/5 CIVINCO KCQ8 Study online at https://quizlet.com/_dial03
11. 2613 sq mm A reinforced concrete beam has a width of 300mm and an
effective depth of 618mm. Compressive reinforcement (if required) will be placed at d'=60mm. f=25MPa and f=415 MPa. The beam is to support a factored bending moment of 520 kN-m. Æ=0.90. Use 2012/2015 NSCP.
Solve for the required area of steel reinforcement, A.
12. 6 pcs A reinforced concrete beam has a width of 300mm and an
effective depth of 618mm. Compressive reinforcement (if required) will be placed at d'=60mm. f=25MPa and f=415 MPa. The beam is to support a factored bending moment of 520 kN-m. Æ=0.90. Use 2012/2015 NSCP.
Determine the minimum number of 25mmØ bars required
as tension reinforcement for the beam to support the given factored bending moment.
13. 6 pcs A rectangular concrete beam having a width of the 250
mm and effective depth of 350 mm will be designed to carry the factored design loads as stated. The steel yield strength f=275 MPa and concrete strength f ' = 20.7 Mpa. If the compression steel is found necessary, it will be placed 60mm from the extreme compression fiber of the beam. Neglect the effect of the displaced concrete and use the 2010 NSCP.
Determine the number of pieces of 20mmØ tension steel
for a singly-reinforced section reinforced with maximum steel for tension control.
14. 6 pcs A rectangular concrete beam having a width of the 250
mm and effective depth of 350 mm will be designed to carry the factored design loads as stated. The steel yield strength f=275 MPa and concrete strength f ' = 20.7 Mpa. If the compression steel is found necessary, it will be placed 60mm from the extreme compression fiber of the beam. Neglect the effect of the displaced concrete and use the 2010 NSCP. 3/5 CIVINCO KCQ8 Study online at https://quizlet.com/_dial03
Determine the number of pieces of 20 mm Ø tension
reinforcements if beam is to carry factored design moment of 135 kN-m
15. 4 pcs A rectangular concrete beam having a width of the 250
mm and effective depth of 350 mm will be designed to carry the factored design loads as stated. The steel yield strength f=275 MPa and concrete strength f ' = 20.7 Mpa. If the compression steel is found necessary, it will be placed 60mm from the extreme compression fiber of the beam. Neglect the effect of the displaced concrete and use the 2010 NSCP.
Determine the number of pieces of 20 mm Ø tension
reinforcements if beam is to carry factored design moment of 80 kN-m
16. 246 mm A rectangular reinforced concrete beam has a width of
300 mm and an effective depth of 600 mm. The beam is subjected to a service bending moment of 200 kN-m and a service dead load of 15 kN/m. The section is reinforced with 4-32mmØ bars. The modular ratio n=8.
Using the Alternate Design method, find the distance of
the neutral axis from the top of the beam.
17. 10.45 MPa A rectangular reinforced concrete beam has a width of
300 mm and an effective depth of 600 mm. The beam is subjected to a service bending moment of 200 kN-m and a service dead load of 15 kN/m. The section is reinforced with 4-32mmØ bars. The modular ratio n=8.
Determine the maximum stress in concrete in MPa.
18. 386 A rectangular reinforced concrete beam has a width of
300 mm and an effective depth of 600 mm. The beam is subjected to a service bending moment of 200 kN-m and a service dead load of 15 kN/m. The section is reinforced with 4-32mmØ bars. The modular ratio n=8. 4/5 CIVINCO KCQ8 Study online at https://quizlet.com/_dial03
Calculate the total compressive force in concrete in kN?
19. 400 A reinforced concrete tied column is to be designed to
support a factored axial load of 2500 kN. Use f'c = 28 MPa, fy = 400 MPa, and the NSCP 2010.
The required dimension of a circular spiral column if a 2%
gross steel ratio is not exceeded for economic reason
20. 400 A reinforced concrete tied column is to be designed to
support a factored axial load of 2500 kN. Use f'c = 28 MPa, fy = 400 MPa, and the NSCP 2010.
Determine the required dimension of a square-tied column
if a 2% gross steel ratio is not be exceeded for economic reason