CIVINCO KCQ8

Study online at https://quizlet.com/_dial03

1. 290 For the concrete column shown below, b = 250 mm, h =


400 mm, d' = 65 mm. The column is reinforced with 6-25
mm diameter rebar with fy = 415 MPa. F'c = 27 MPa

What is the balanced eccentricity?

2. 1794 For the concrete column shown below, b = 250 mm, h =


400 mm, d' = 65 mm. The column is reinforced with 6-25
mm diameter rebar with fy = 415 MPa. F'c = 27 MPa

What is the ultimate axial design capacity of the column in


kN?

3. 965.8 For the concrete column shown below, b = 250 mm, h =


400 mm, d' = 65 mm. The column is reinforced with 6-25
mm diameter rebar with fy = 415 MPa. F'c = 27 MPa

What is the total compressive force (nominal) in concrete


under balanced condition?

4. 2760 For the concrete column shown below, b = 250 mm, h =


400 mm, d' = 65 mm. The column is reinforced with 6-25
mm diameter rebar with fy = 415 MPa. F'c = 27 MPa

What is the nominal axial load capacity of the column in


kN?

5. 76.08 A precast concrete beam T-beam has a flange width of


600 mm, flange thickness of 100 mm, width of 300 mm,
effective depth of 580 mm, and a total depth of 600 mm.
Use f;c = 21 MPa and fy = 415 MPa. The section is
reinforced with 4-25 mm bars in tension.

Calculate the depth of the compression block in mm.

6. 0.0164 A precast concrete beam T-beam has a flange width of


600 mm, flange thickness of 100 mm, width of 300 mm,
effective depth of 580 mm, and a total depth of 600 mm.
Use f;c = 21 MPa and fy = 415 MPa. The section is

1/5
CIVINCO KCQ8
Study online at https://quizlet.com/_dial03
reinforced with 4-25 mm bars in tension.

Compute for the strain in tension steel

7. 52.20 A precast concrete beam T-beam has a flange width of


600 mm, flange thickness of 100 mm, width of 300 mm,
effective depth of 580 mm, and a total depth of 600 mm.
Use f;c = 21 MPa and fy = 415 MPa. The section is
reinforced with 4-25 mm bars in tension.

If the beam is 8 m long, find the maximum concentrated


service liveload at midspan that can be supported by the
beam if it already carries a total service uniform load of 24
kN/m. Use 1.2DL+1.6LL.

8. 0.02573 A reinforced concrete beam has a width of 300mm and an


effective depth of 618mm. Compressive reinforcement (if
required) will be placed at d'=60mm. f=25MPa and f=415
MPa. The beam is to support a factored bending moment
of 520 kN-m. Æ=0.90. Use 2012/2015 NSCP.

Calculate the steel ratio for balance section, Pb.

9. 0.01409 A reinforced concrete beam has a width of 300mm and an


effective depth of 618mm. Compressive reinforcement (if
required) will be placed at d'=60mm. f=25MPa and f=415
MPa. The beam is to support a factored bending moment
of 520 kN-m. Æ=0.90. Use 2012/2015 NSCP.

Determine the governing steel ratio (p) following NSCP


requirements.

10. 4 pcs A reinforced concrete beam has a width of 300mm and an


effective depth of 618mm. Compressive reinforcement (if
required) will be placed at d'=60mm. f=25MPa and f=415
MPa. The beam is to support a factored bending moment
of 520 kN-m. Æ=0.90. Use 2012/2015 NSCP.

Determine the maximum number of 25mmØ bars that can


be used for given section if it is singly-reinforced.
2/5
CIVINCO KCQ8
Study online at https://quizlet.com/_dial03

11. 2613 sq mm A reinforced concrete beam has a width of 300mm and an


effective depth of 618mm. Compressive reinforcement (if
required) will be placed at d'=60mm. f=25MPa and f=415
MPa. The beam is to support a factored bending moment
of 520 kN-m. Æ=0.90. Use 2012/2015 NSCP.

Solve for the required area of steel reinforcement, A.

12. 6 pcs A reinforced concrete beam has a width of 300mm and an


effective depth of 618mm. Compressive reinforcement (if
required) will be placed at d'=60mm. f=25MPa and f=415
MPa. The beam is to support a factored bending moment
of 520 kN-m. Æ=0.90. Use 2012/2015 NSCP.

Determine the minimum number of 25mmØ bars required


as tension reinforcement for the beam to support the given
factored bending moment.

13. 6 pcs A rectangular concrete beam having a width of the 250


mm and effective depth of 350 mm will be designed to
carry the factored design loads as stated. The steel yield
strength f=275 MPa and concrete strength f ' = 20.7 Mpa. If
the compression steel is found necessary, it will be placed
60mm from the extreme compression fiber of the beam.
Neglect the effect of the displaced concrete and use the
2010 NSCP.

Determine the number of pieces of 20mmØ tension steel


for a singly-reinforced section reinforced with maximum
steel for tension control.

14. 6 pcs A rectangular concrete beam having a width of the 250


mm and effective depth of 350 mm will be designed to
carry the factored design loads as stated. The steel yield
strength f=275 MPa and concrete strength f ' = 20.7 Mpa. If
the compression steel is found necessary, it will be placed
60mm from the extreme compression fiber of the beam.
Neglect the effect of the displaced concrete and use the
2010 NSCP.
3/5
CIVINCO KCQ8
Study online at https://quizlet.com/_dial03

Determine the number of pieces of 20 mm Ø tension


reinforcements if beam is to carry factored design moment
of 135 kN-m

15. 4 pcs A rectangular concrete beam having a width of the 250


mm and effective depth of 350 mm will be designed to
carry the factored design loads as stated. The steel yield
strength f=275 MPa and concrete strength f ' = 20.7 Mpa. If
the compression steel is found necessary, it will be placed
60mm from the extreme compression fiber of the beam.
Neglect the effect of the displaced concrete and use the
2010 NSCP.

Determine the number of pieces of 20 mm Ø tension


reinforcements if beam is to carry factored design moment
of 80 kN-m

16. 246 mm A rectangular reinforced concrete beam has a width of


300 mm and an effective depth of 600 mm. The beam is
subjected to a service bending moment of 200 kN-m and
a service dead load of 15 kN/m. The section is reinforced
with 4-32mmØ bars. The modular ratio n=8.

Using the Alternate Design method, find the distance of


the neutral axis from the top of the beam.

17. 10.45 MPa A rectangular reinforced concrete beam has a width of


300 mm and an effective depth of 600 mm. The beam is
subjected to a service bending moment of 200 kN-m and
a service dead load of 15 kN/m. The section is reinforced
with 4-32mmØ bars. The modular ratio n=8.

Determine the maximum stress in concrete in MPa.

18. 386 A rectangular reinforced concrete beam has a width of


300 mm and an effective depth of 600 mm. The beam is
subjected to a service bending moment of 200 kN-m and
a service dead load of 15 kN/m. The section is reinforced
with 4-32mmØ bars. The modular ratio n=8.
4/5
CIVINCO KCQ8
Study online at https://quizlet.com/_dial03

Calculate the total compressive force in concrete in kN?

19. 400 A reinforced concrete tied column is to be designed to


support a factored axial load of 2500 kN. Use f'c = 28 MPa,
fy = 400 MPa, and the NSCP 2010.

The required dimension of a circular spiral column if a 2%


gross steel ratio is not exceeded for economic reason

20. 400 A reinforced concrete tied column is to be designed to


support a factored axial load of 2500 kN. Use f'c = 28 MPa,
fy = 400 MPa, and the NSCP 2010.

Determine the required dimension of a square-tied column


if a 2% gross steel ratio is not be exceeded for economic
reason

5/5