Intelligent digital display instruments

【Intelligent multi-channel data-logging display controller】


> Summarize
Intelligent multi-channel data-logging display controller adopt advanced microprocessor for smart
control, It is suitable for display and control temperature, humidity, pressure, liquid level, instantaneous
flow, speed and so on in many physical quantity inspect signal, and can data-logging multi-channel
measure signal. it also can carry on high-accuracy linear correction to various non-linear input signals.
Each input port all have function of universal signal input and single channel input, and each channel
can input the different type signal at the same time. They only need to simple selection by instrument’s
menu when input signal is full switching, namely can realized lightly switching in different type input
signal (a variety of thermocouple, thermo resistance, standard voltage/current signal), and improved
universality and reliability of instrument.
Control output has two kinds: each channel unite alarm / transmit output; each channel respectively
independent alarm /transmit output. Unite alarm type again classified into: alarm memory and alarm no
memory type. Input/output loop all adopt photoelectric isolation, which have the better anti-jamming
ability.
There are two kinds display for high-brightness LED numeric and the whole Chinese large screen
LCD liquid crystal. They can take serial communication interface. The whole machine uses cassette insert
construction, easy to installation.
 Outline dimension and open dimension

Less then 16 channels outline dimension:160×80×140mm less then 16 channel outline dimension:80×160×140mm

32 channels outline dimension:160×80×252mm 32 channels outline dimension:80×160×252mm


+0.7 +0.7 +0.7 +0.7
Open hole dimension:152 -0 ×76 -0 mm Open hole dimension:76 -0 ×152 -0 mm

12
Intelligent digital display instrument

> Type spectrum table for intelligent multi-channel data-logging display controller
Model Explanation
WP- □ □□□ -□ □ □□ -□ □ □ -□
D Double-screen numeric horizontal type display
Outline S Double-screen numeric vertical type display
feature MD Liquid crystal horizontal type display
MS Liquid crystal vertical type display
806 Eight-channels data-logging measurement display
807 Eight-channels data-logging measurement with unite alarm
808 Eight-channels data-logging respectively output measurement
Channel and
controller (note 2)
control
809 Sixteen-channels data-logging measurement display
816 Sixteen-channels data-logging measurement with unite alarm
832 32-channels data-logging measurement with unite alarm
0 No communication interface
Communicatio
2 RS-232C communication interface
n mode
8 RS-485 communication interface
1 Relay control or alarm output
2 (4~20)mA output
3 (0~10)mA output
4 (1~5)V output
Output mode
5 (0~5)V output
6 SCR zero crossing -trigger pulse output
7 SSR control signal output
8 Special specification transmission output
Input type □□ See “input type table”
N No control/alarm
First alarm H First alarm is high limit alarm
L First alarm is low limit alarm
Second alarm □ Same as first alarm mode
Feed output P DC24V feed output (no feed can be omitted)
AC220V linear power supply (can be omitted)
Supply mode T AC (90~265) switch power supply
W DC24V supply power
★ Note 1: 8-channel respective output and 16-channel data logging instrument have aviation plug and
post type connection, post type is approved when out of factory, if need aviation plug, explain
while ordering, please connection mode of 32 –channel data logging instrument only has
aviation plug.
2. Respective output is 8-channel up limit + 8-channel down limit control alarm output or
8-channel respective transmitting output, output relay or transmitting select one.
Option as an example: WP-D806-02-23-N-T; WP-MD832-81-23-HL-T
 Wiring diagram
>> Post type wiring diagram (unity output)
8-channel
1
RTD
first channel 9 9
mA/V/TC
1 8 17 17
mA /V
2
1 2 3 …… …… 7 8
9 ALM1 2
3 RTD
10 seco nd c hanne l 1 0 10 mA/V/TC
…… …… 11 18 18
9 10 1 1 15 16 ALM2
5 12 ……
…… ……
……
T/ R(A) 6 1 7 18 1 9 …… …… 23 24
13
RS -485 po wer 8
T/ R(B) 7 14 RTD
eighth channel 1 6
eight 16
mA/V/TC
24 24

13
Intelligent digital display instruments

16-channels
1
fir st ch ann el 17 RTD
17
mA/V/TC
1 8 33 33
m A/V
2 …… …… 9 A L M1 2
1 2 3 15 16 RTD
3 10 seco nd channel 18 18
mA/V/TC
11
17 18 19 …… …… 3132 A L M2 34 34
5 12 …… ……
T/ R(A ) 6 33 34 35 …… …… 4748
13
…… ……
RS-485 p ow er 16
T/ R(B) 7 14 RTD
Six th channel 32
Sixteenth 32
mA/V/TC
48 48

Aviation plug mode

>> Aviation plug mode wiring diagram

1 19 36 8
mA/ V
2 1 18 9 AL M1
3 9~16 chann el inpu t 10
19 36 11
AL M2
5 1 18 12
1 ~ 8 chan nel in put
T/R( A) 6 13
RS-485 Power
T/R( B) 7 Outli ne:160×80 ×140mm 14
Outli ne:80×160 ×140mm

9~16 c hanne l
19 36

8-channels 1 R YB 18
19 36

1 R YB 18
I/Vin I/Vin I/V in I/Vin I/Vin I/Vin I/Vin I/Vin
/TCi n /TCi n /TC in /TCin /TCin /TCi n /TCi n /TCi n
9 10 11 1 2 1 3 1 4 15 16

I /Vin I /Vin I/Vin I/ Vin I/ Vin I /Vin I /Vin I /Vin 1 ~8 channel


/ TCin / TCin /TCin /TCin /TCin / TCin / TCin / TCin
1 2 3 4 5 6 7 8 19 36

1 R YB 18

I/Vin I/Vin I/V in I/Vin I/Vin I/Vin I/Vin I/Vin


/TCi n /TCi n /TC in /TCin /TCin /TCi n /TCi n /TCi n
1 2 3 4 5 6 7 8

32-channels

14
Intelligent digital display instrument

12 11 10 9 8 7 6 5 4 3 2 1

A B POWER
RS-4 85 A LM 2 ALM 1
O u t dime
Outline li n e :nsion:160
:160 ×80 252mm
×
×80 × 252mm

in put si g na l w ir i n g dia gr a m

>> Post type wiring diagram (respectively output)

2 5 ……… … 27
3
mA/ V/TC
6
mA/ V/TC
……… … 28
mA/ V/TC

CH1 CH2 CH3 CH4


1 8
2 9
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
3 10
CH5 CH6 CH7 CH8
11
5 12
17 18 19 20 21 22 23 2 4 25 26 27 28 29 30 31 32
T/R(A) 6 13
RS-485 Pow er
T/R(B) 7 33 34 35 36 37 38 39 40 4 1 42 43 44 45 46 47 48 49 14

Alarm
output sign al

M ain machine
Assista nt machine wiring
diagram(for relav output)
Channel A L1 AL2
1 8 15 22 29 First cha nnel 1 8 15 22
2 9 16 23 30 Second channel 2 9 16 23
3 10 17 24 31
Third cha nnel 3 10 17 24
11 18 25 32
Fourth ch ann el 4 11 18 25
5 12 19 26 33
6 13 20 27 34 Fifth cha nnel5 12 19 26
Powe r
7 14 21 28 35 Sixth channel 6 13 20 27
Assista nt machine Seventh channel 7 14 21 28
Eitghth channel 29 30 32 33

15
Intelligent digital display instruments

2 5 …… …… 27
3
mA/V/TC
6
mA/V/TC
…… …… 28
mA/V/TC

1 8
2 9
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
3 10
11
5 12
1 7 1 8 1 9 2 0 2 1 2 2 23 2 4 2 5 2 6 2 7 2 8 2 9 3 0 3 1 3 2
T/R(A) 6 13
RS-485 POWER
T/R(B) 7 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 14

mA/V 1 15 CH1 CH8 22 8 mA/V

mA/V 2 16 CH2 23 9
mA/V 3 17 CH3 24 10
mA/V 4 18 CH4 25 11
mA/V 5 19 CH5 26 12
mA/V 6 20 CH6 27 13
POWER
mA/V 7 21 CH7 28 14

>> Aviation plug type wiring diagram (respective output)


Main machine

Out line:160×80 ×140mm


1 8
2 19 36 9
3 1 18 10
1~8channel input 11
5 12
T /R(A) 6 13
RS-485 DA TA OUT Power
T /R(B) 7 14

Connect to a ssis tant machine

8 -channe ls in pu t wirin g dia gram


19 36

1 RY B 18

I/Vin I /Vin I/Vin I/Vin I/Vin I/Vin I/ Vin I/V in


/TCin / TCin /TCin /TCin /TCin /TCin /TCin /TCi n
1 2 3 4 5 6 7 8

16