2003 49e Ed7 1
2003 49e Ed7 1
2003 49e Ed7 1
n x 2 x 0.6 or 0.8 mm Bd
Halogen-free, flame-retardant, low-smoke internal
telecommunication cable with electrostatic screen, unit-
stranded
Specification DIN VDE 0815
© 2009
Changes reserved according
to technical progress.
Fire test DIN EN 50266-2-4 (according to IEC 332-3
test type C)
Principle drawing
J-H(St)H 50x2x0.6 Bd
Application
Used as installations cable in local networks, especially for fixed indoor installations in fire protected areas.
Not admissible as power installation cable and not allowed for laying in ground.
Construction
J-H(St)H
Conductor copper, solid, 0.6 or 0.8 mm, soft annealed
Insulation halogen-free, flame-retardant compound (H), ring marking of cores according to DIN VDE 0815
Twisting quads in unit-stranding (SZ-stranding)
Cable core wrapping at least one layer of plastic tape
Screen electrostatic screen; tinned copper drain wire of diameter 0.6 or 0.8 mm galvanically connected
with the laminated aluminium/PETP tape
Outer sheath halogen-free, flame-retardant compound (H), grey
nx2x0.8 also suitable as fire alarm cable with red outer sheath and printing
“BRANDMELDEKABEL”.
2003_49e_Ed7
LINKING THE FUTURE www.prysmiangroup.com Version 7 | 10.09.2009
Page 1 of 3
J-H(St)H
n x 2 x 0.6 or 0.8 mm Bd
*
For cable with 4 pairs mentioned value may not exceed 20 %.
**
20% of the values , at least however 1 value may amount to 500 pF.
***
10% of the values, at least however 4 values (relations), may amount to 300 pF.
2003_49e_Ed7
LINKING THE FUTURE www.prysmiangroup.com Version 7 | 10.09.2009
Page 2 of 3
J-H(St)H
n x 2 x 0.6 or 0.8 mm Bd
Additional Properties
Product Outer Cable Standard Drum Transport Copper
code Dimension diameter weight supply size/ weight content
(grey) ca. net length flange-Ø gross ca.
ca.
ca. mm kg/km m kg/drum kg/km
J-H(St)H n x 2 x 0.6 Bd
1016306-*… 2x 6.2 48 1000 S6** 55 14
1019147-*… 4x 8.8 81 1000 S7** 91 25
1019148-*… 6x 9 94 1000 S7** 104 37
1008201-*… 10 x 10.7 135 1000 NG10/ 1000 215 60
1008202-*… 20 x 13.5 221 1000 NG10/ 1000 301 116
1008203-*… 30 x 15.8 302 1000 NG12/ 1200 472 172
1019162-*… 40 x 17.7 382 1000 NG12/ 1200 507 229
1019163-*… 50 x 19.8 478 1000 NG14/ 1400 608 286
1019166-*… 60 x 21.3 556 1000 NG14/ 1400 686 342
1019167-*… 80 x 23,9 707 1000 NG14/ 1400 837 455
1000169-*… 100 x 26.7 882 1000 NG16/ 1600 1087 568
J-H(St)H n x 2 x 0.8 Bd
1019149-*… 2x 7.0 65 1000 S6** 71 25
1019150-*… 4x 10.4 112 1000 NG10/ 1000 192 46
1019151-*… 6x 10.6 135 1000 NG10/ 1000 215 65
1019152-*… 10 x 12.6 197 1000 NG10/ 1000 277 106
1019153-*… 20 x 16.3 335 1000 NG12/ 1200 460 206
1019154-*… 30 x 19.6 485 1000 NG14/ 1400 615 306
1019155-*… 40 x 21.9 616 1000 NG14/ 1400 746 407
1019156-*… 50 x 24 743 1000 NG14/ 1400 843 508
1019157-*… 60 x 26,2 894 1000 NG16/ 1600 1099 608
1019160-*… 80 x 30 1174 1000 NG16/ 1600 1379 809
1019161-*… 100 x 33 1428 1000 NG18/ 1800 1808 1010
*... Delivery length and packaging code, for example at 1000m lengths: 01000DX
S6**, S7** ply wood drums, ≥NG10…drum one way (solid wood)
2003_49e_Ed7
LINKING THE FUTURE www.prysmiangroup.com Version 7 | 10.09.2009
Page 3 of 3