ULTRAMETER

Advanced Design • Superior Performance

Choice of KCl, NaCl, and 442™ bluDock Enabled


TM

Natural Water Standards


ORP mV to ppm free
chlorine conversion (6Pfc)
pH/ORP Sensor Both Ultrameter IIs
protective cap (6Pfc) are capable of
wireless data
Four-digit display for transfer with
full 9999 readings, with bluDock™ option
autoranging capability installed
up to 200 mS/200 ppt
Powerful microprocessor
based surface-mount
circuitry

Display prompts for simple


pH calibration
Memory for 100 readings
with Date & Time Stamp
RealTime Clock
Factory calibrations
stored in microprocessor

Ultra-fast
Ultra-easy
Ultra-Powerful
S ince 1957, the Myron L Company has designed and
manufactured highly reliable analytical instruments
for a wide variety of applications. Thousands of
W e are proud of the trust our handheld instruments
and monitor/controllers have earned in the past.
Ourproductlinehasevolvedtoanewlevelofoutstanding
professionals around the world rely every day on the performance and value in analytical instruments: the
performance of our instruments. Demanding uses range Ultrameter II series. While priced like affordable
from boiler water testing to ultrapure water control to single-parameter instruments, the Ultrameter II does
medical instruments for artificial kidney machines. the job of three, four or even six instruments.
Accuracy You Can Trust Advanced Features Benefits Designed to
Both Ultrameter II models deliver • 3 solution standards for greatest Save you time & money
performance of ±1% of reading accuracy in diverse applications
(not merely full scale). This high
• Fully automatic temperature The 6Pfc measures a
level of accuracy has been achieved
compensation dynamic range of free
through advanced four-electrode
• User adjustable temperature chlorine concentrations
conductivity cell technology, a
wider than the range of
unique pH/ORP sensor and powerful compensation (up to 9.99%/°C)
colorimetric test kits.
microprocessor-based circuitry.With which also allows TC to be
displayed values of up to 9999, the disabled for applications requiring
full four-digit LCD ensures resolution non-compensated readings. Easily transfer stored
readings to Macintosh
levels never before possible in • User adjustable conductivity/
and PC platforms with
such affordable instruments. TDS conversion ratio for greater the optional bluDock™
FactorycalibratedwithNIST traceable accuracy when measuring accessory package.
solutions, each Ultrameter II may solutions not contained in the
be supplied with both certification microprocessor. Ample memory provides
of traceability and NIST traceable • Auto-shutoff maximizes the life increased flexibility to
solutions for definitive calibration. of the single 9V battery to more record and store 100
than 100 hours/5000 tests. separate readings.
Fast and accurate
in the laboratory, both • Non-volatile microprocessor
provides data back-up, even Real Time Clock with
Ultrameter II models
Date & Time Stamp
are rugged enough for when the battery is changed.
allows you to maintain
daily in-line controller This assures all calibrations and
the integrity of each
checks in hostile memory data will be retained.
individual reading.
process applications.
• Extended life pH/ORP sensor is
user replaceable in the field.
Innovative Engineering The advanced four-
electrode cell for
The Ultrameter II is a prime example
conductivity/resistivity/
of how high-tech engineering can High Performance at a
TDS eliminates
greatly simplify and streamline a task. Low Cost
polarization, allowing
Whether in the lab, industrial plant, Beyond their affordable purchase greater accuracy and
or in a remote field location, merely: price, Ultra-Fast, Ultra-Easy, Ultra- stability with minimal
1. Fill the cell cup Powerful Ultrameter IIs save both maintenance.
time and money. Measure for
2. Push a parameter key
measure, Ultrameter IIs give you a The pH/ORP sensor
3. Take the reading better return on your investment than chamber provides
Temperature compensation and anyotherhandheldinstrument.Tosee protection to a unique
range selection are both rapid and for yourself, contact your distributor porous liquid-junction.
automatic. The Ultrameter II is a or the Myron L Company today.
true one-hand operation instrument. The large capacity KCI
Multiple Applications reservoir guarantees
Easy to Calibrate • Irrigation Water
extended life.
All calibrations are quickly
accomplished by pressing the • Hydroponics A custom LCD helps
 or  keys to agree with our • Laboratories simplify calibration
NIST traceable Standard Solution. • Homeland Security and operation by using
When calibration is necessary, annunciators and
• Reverse Osmosis prompts to indicate
display prompts simplify pH
calibration and make sure the • Deionization various conditions.

correct buffer is being used. • Wastewater


Plus, all parameters (excluding IP67/NEMA 6 rated
• Cooling Towers
Ultrameter IIs are
factory-set temperature) have an • Environmental waterproof and buoyant
internal electronic setting that can
• Desalination and can be fully
be used for field calibration and
immersed to
as a check on pH/ORP sensor life. • Fountain Solutions
3 feet/1 meter.
Features Specifications
Ultrameter II™ Models 4PII 6Pfc Display 4 Digit Liquid Crystal Display
Conductivity Conductivity
TDS, Resistivity TDS, Resistivity, pH Dimensions: LxWxH 196 x 68 x 64 mm/7.7 x 2.7 x 2.5 inches
Temperature ORP, Free Chlorine Weight 352 g/12.4 oz.
Temperature
Case/conductivity cell material valox*
ORP mV and Free Chlorine •
Autoranging • • Cell capacities pH/ORP: 1,2 ml/0.04 oz.
Adjustable Temp. Compensation • • Cond/TDS/Res: 5 ml/0.2 oz.
Adjustable Cond/TDS ratio • • Power 9V alkaline battery
Memory (100 readings) • •
Battery life >100 hours (5000 readings)
Date & Time Stamp • •
pH Calibration Prompts • Operating/storage temperature 0 – 55°C/32 – 132°F
Low battery indicator • • Protection ratings IP67/nema 6
Auto-off • • Waterproof to 1 meter/3 feet
* ® Sabic Innovative Plastics

Parameters
Conductivity TDS Resistivity pH ORP/Free Chlorine Temperature
Ranges 0–9999 µS/cm 0–9999 ppm 10 KΩ–30 MΩ 0–14 pH ±999 mV 0–71°C
10–200 mS/cm 10–200 ppt 0.00–10.00 ppm 32–160°F
in 5 autoranges in 5 autoranges
Resolution 0.01(<100 µS) 0.01(<100 ppm) 0.01(<100 KΩ) ±0.01 pH ±1 mV 0.1°C/F
0.1(<1000 µS) 0.1(<1000 ppm) 0.1(<1000 KΩ) 0.01 ppm
1.0(<10 mS) 1.0(<10 ppt) 0.1(>1 MΩ)
0.01(<100 mS) 0.01(<100 ppt)
0.1(<200 mS) 0.1(<200 ppt)
Accuracy ±1% of reading ±1% of reading ±1% of reading ±0.01 pH* ±1 mV ±0.1°C
<1ppm ±.5ppm** —
≥1ppm ±.2ppm
Auto Temperature Compensation 0–71°C 0–71°C 0–71°C 0–71°C — —
32–160°F 32–160°F 32–160°F 32–160°F
Adjustable Temperature 0–9.99%/°C 0–9.99%/°C 0–9.99%/°C — — —
Compensation to 25ºC
Conductivity/TDS Ratios Preprogrammed KCl, 442***, NaCl KCI, 442***, NaCl — — — —
Adjustable Conductivity/TDS Ratio Factor 0.20–7.99 0.20–7.99 — — — —
*± .2 pH in presence of RF fields ≥ 3V/m and >300MHz **Given water is sanitized by chlorine only when 5<pH<9 ***442 Natural Water Standard ™ Myron L Company

Accessories
bluDock™ Accessory Package pH Buffers are necessary to maintain Hard protective case (kit) with
includes bluDock™, Macintosh/PC accuracy and for periodic calibration of three buffers (pH 4, 7, and 10),
application software for downloading pH and ORP parameters. Calibration one pH/ORP storage solution,
data and printed instructions. with pH 7 Buffer is especially and two standard solutions,
model: BLUDOCK important. All pH 4, 7, and 10 Buffers (KCI-7000 and 442-3000).
Certificates confirming the NIST are NIST traceable and are available in All bottles are 2 oz/59 ml.
traceability of an Ultrameter II are 2 oz/59 ml, 1 qt/1 L, and 1 gal/3,8 L. model: PKUU (Replaces PKU)

available (must be specified when pH Sensor Storage Solution Soft protective case is
placing instrument order). model: MC Available in 2 oz/59 ml, 1 qt/1 L, and constructed of padded Nylon
ConductivityStandardSolutionsare 1 gal/3,8 L. and features a belt clip for
necessary to maintain accuracy and for model: SS20Z, SSQ and SSG hands-free mobility. models: UCC
periodiccalibrationofconductivity/TDS Certificate of NIST traceability for (Blue) and UCCDT (Desert Tan)
parameters. All Standard Solutions pH Buffer or Conductivity Standard Replacement pH/ORP sensor
are NIST traceable for your complete Solutions are available (must be user-replaceable, features a
confidence. recommended values: KCl- specified when placing solution order). unique/porous liquid-junction.
7000 (7 mS), 442-3000 (TDS), or model: SC model: RPR
NaCl-14.0 (mS) available in 2 oz/59 Hard protective case (small) ORP Sensor Conditioner Solution
ml, 1 qt/1 L, and 1 gal/3,8 L. model: UPP model: ORPCOND
Built on Trust Limited Warranty
Founded in 1957, Myron L Company is one of the world’s All Myron L Ultrameter IIs have a Two (2) Year Limited
leading manufacturers of water quality instruments. Because Warranty. The pH/ORP sensors have a Six (6) Month
of our policy of continuous product improvement, changes in Limited Warranty. Warranty is limited to the repair or
design and the specifications in this brochure are possible. replacement of the Ultrameter II only, at our discretion.
You have our assurance any changes will be guided by Myron L Company assumes no other responsibility or liability.
our product philosophy: Accuracy, Reliability, Simplicity.

2450 Impala Drive


Carlsbad, California 92010-7226 USA
Tel: +1-760-438-2021 www.myronl.com
Water Quality Instrumentation
Accuracy • Reliability • Simplicity Fax: +1-800-869-7668 / +1-760-931-9189
Printed in U. S. A. Specifications subject to change without notice © Myron L Company 2011