0% found this document useful (0 votes)
8 views12 pages

Eclipse en LQ

Download as pdf or txt
Download as pdf or txt
Download as pdf or txt
You are on page 1/ 12

Eclipse

Adaptative Flow Control

Thermostatic Radiator Valves


With automatic flow limitation
IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Eclipse

Eclipse
The thermostatic radiator valve Eclipse has a unique integrated
flow limiter that eliminate over flows. The required flow rate can be
adjusted directly at the valve with a twist. The adjusted flow will not
be exceed even if there are load changes in the system, due to other
valves closing or during morning start up. The valve controls the flow
rate independently from differential pressure. Therefore, complicated
calculations to determine settings are not necessary.

Key features
> Integrated flow limiter > Perfect for renovation
Eliminates over flows Standard dimensions and easy flow
sizing
> Easy adjustment
Just a twist to reach design flow > All valve bodies with II+ marking
can be retrofitted as Eclipse
> Flow range from 10 to 150 l/ h i.e. V-exact II, Standard, Multilux,
For high flexibility Multilux 4-Set

Technical description

Applications area: Differential pressure (ΔpV): Orange protection cap.


Heating and cooling systems. Max. differential pressure:
60 kPa (<30 dB(A)) Standards:
Function: Min. differential pressure: Valves meet the following requirements:
Control 10 – 100 l/h = 10 kPa – KEYMARK certified and tested to DIN
Flow limitation 100 – 150 l/h = 15 kPa EN 215, series D.
Shut-off
Materials:
Dimensions: Valve body: Corrosion resistant Gunmetal.
DN 10-20 O-rings: EPDM rubber
Valve disc: EPDM rubber
Pressure class: 011
Return spring: Stainless steel
PN 10 Valve insert: Brass, PPS
(polyphenylsulphide) and SPS Pipe connection:
Temperature: (syndiotactic polystyrene) The female-threaded version is designed
Max. working temperature: 120°C, with The complete thermostatic insert can be for connection to threaded pipe, or in
protection cap or actuator 100°C, with replaced using the HEIMEIER fitting tool conjunction with compression fittings, to
press connection 110°C. without draining the system. copper precision steel or multi-layer pipe
Min. working temperature: -10°C. Spindle: Niro-steel spindle with double (only DN 15). The male-threaded version,
O-ring sealing. in conjunction with the appropriate
Flow range: compression fittings, permits connection
The flow can be stepless pre-set within Surface treatment: to plastic pipe. Versions with Viega press
the range: 10-150 l/h. Valve body and fittings are nickel-plated. connection (15 mm) with SC-Contur
Delivery setting: Commissioning. are suitable for copper, Viega Sanpress
(Max. nominal flow qmN at 10 kPa stainless-steel, and Prestabo steel pipe.
Marking:
concerning EN 215: 110 l/h) THE, country code, flow direction arrow,
DN and KEYMARK-Designation. Connection to thermostatic head and
II+ Designation. actuator:
HEIMEIER M30x1.5

2
Construction
Eclipse

  1. S
 trong return spring in combination with high locating force
ensures that the valve does not slacken off over time
2. H
 EIMEIER M30x1.5 connection for thermostatic heads and
 actuators
 3. Automatic flow limiter
4. Valve body in corrosion-resistant gunmetal
 5. Long-life double O-ring sealing
6. Flow setting

Replaceable insert
 The complete thermostatic insert can be replaced using the
HEIMEIER fitting tool without draining the system.

Function
Eclipse flow limiter
A regulating part is set to the calculated control rate by turning The set flow rate is therefore never exceeded. If the flow rate
the digit cap with the setting key or an 11 mm end wrench. If drops below the set value a spring presses the sleeve back to
the flow rate increases at the valve the rising pressure moves the its original position.
sleeve, thus constantly limiting the flow to the set value.

Application
The thermostatic radiator valve Eclipse is applied in two-pipe Renovation
pumped heating system with normal to high temperature Eclipse replaces old valves easily due to dimensions according
spread. to EN 215 standard. All HEIMEIER thermostatic radiator valves
The required design flow for each radiator is set directly on the with II+ marking, i.e. V-exact II, Standard, Multilux, Multilux 4-Set
Eclipse valve. This automatic flow limitation is done with a twist can be retrofitted as Eclipse.
and the adjusted flow will then not be exceeded. Even if there is
Noise behaviour
an oversupply of pressure, due to load changes in the system,
To ensure low-noise performance, the following conditions must
for example other valves closing or during morning start up,
be met:
Eclipse will guarantee the requested flow.
•T he differential pressure above Eclipse should not exceed
The valve controls the flow rate independently from differential 60 kPa = 600 mbar = 0,6 bar (<30 dB(A)).
pressure. Therefore, complicated calculations to determine • Flow must be correctly adjusted.
settings are not necessary. The pressure loss of pipings in old • The system must be completely deaerated.
systems does not have to be determined in renovation projects.
Only the heating capacity and the resulting max. flow rate
have to be determined (see setting chart). The min. differential
pressure has to be at the most unfavourable valve. If necessary,
it can be measured in order to optimize pump settings (see
accessories).

3
IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Eclipse

Sample application

1. Eclipse
2. Lockshield Regulux/Regutec
3. STAD balancing valve for maintenance and diagnostics
4. Boiler

Notes
– To avoid damage and the formation of scale deposit in the hot – The thermostatic valve bodies can be used with all HEIMEIER
water heating system, the composition of the heat transfer thermostatic heads and HEIMEIER or TA thermal or
medium should be in accordance with the VDI guideline 2035. motorized actuators. The optimal tuning of the components
For industrial and long-distance energy systems, see the guarantees maximum safety. When using actuators from
applicable codes VdTÜV and 1466/AGFW FW 510. other manufacturers, make sure that the pressure power is
A heat transfer medium containing mineral oils, or any type of appropriate for thermostatic valve bodies with soft sealing
lubricant containing mineral oil can have extremely negative valve discs.
effects and usually lead to the disintegration of EPDM seals.
When using nitrite-free frost and corrosion resistance solutions
with an ethylene glycol base, pay close attention to the details
outlined in the manufacturers’ documentation, particularly
concerning concentration and specific additives.

–F
 lush the system before changing thermostatic valves in heavy
polluted existing systems.

4
Operation
Flow setting
Stepless setting between 1 to 15 (10 to 150 l/h). • Place the setting key on the valve insert.
The setting is changed using a special setting key (article No. •T urn the setting tool so that desired setting value is pointing at
3930-02.142) or an 11 mm end wrench, to ensure tamper proof the index* of the valve body (see fig.).
setting. • Remove the key or 11 mm end wrench. The valve is now set.

Front-end and lateral visibility

*) **)
SW 11

*) Index
**) Commissioning setting

Setting 1 l l l 5 l l l l 10 l l l l 15

l/h 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150

P-band [xp] max. 2 K.


P-band [xp] max. 1 K up to 90 l/h.

5
IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Eclipse

Diagram

25 dB(A)*) 30 dB(A)*)
Lowest flow tolerances
160
l/h

max.
140

120

100

80

60

40 10 30 50 70 90 110 130 150


20 l/h
min. 10 - 100 l/h: 10 kPa
100 - 150 l/h: 15 kPa
0
0 10 20 30 40 50 60
kPa

*) P-band [xp] max. 2 K.

Setting table

Setting values with different radiator performances and system differential temperatures

10 2 2 3 3 4 5 6 7 8 9 10 12 14 15

15 1 1 2 2 3 3 4 5 5 6 7 8 9 10 12 13 14 15

20 1 1 1 2 2 3 3 3 4 4 5 6 7 8 9 10 10 11 12 13 14 15

30 1 1 1 1 1 2 2 2 3 3 3 4 5 5 6 6 7 8 8 9 9 10 10 11 12 14 15

40 1 1 1 1 1 2 2 2 2 3 3 3 4 4 5 5 6 6 7 7 7 8 8 9 10 11 14 15

∆p min. 10 - 100 l/h = 10 kPa


∆p min. 100 - 150 l/h = 15 kPa
Q = Radiator performance
Δt = System differential temperature
Δp = Differential pressure

Sample:
Q = 1000 W, Δt = 15 K
Setting value: 6 (≈ 60 l/h)

6
Articles

SW2*
)
Angle
H1
d2 DN D d2 l3 l4 l5 H1 Flow EAN Article No
l5 range[l/h]
SW*1
)

10 Rp3/8 R3/8 26 52 23,5 23,5 10-150 4024052929313 3931-01.000


D
l3 15 Rp1/2 R1/2 29 58 27 23,5 10-150 4024052929412 3931-02.000
l4
20 Rp3/4 R3/4 34 66 29 23,5 10-150 4024052930715 3931-03.000

SW2*
)
Angle
H1
with reduced lengths. Brass. Not suitable for compression fitting for multi layer pipes.
d2
l5 DN D d2 l3 l4 l5 H1 Flow EAN Article No
*)
D
SW1 range[l/h]
l3
l4 10 Rp3/8 R3/8 24 49 20 24 10-150 4024052932313 3461-01.000
15 Rp1/2 R1/2 26 53 23 23,5 10-150 4024052932412 3461-02.000
20 Rp3/4 R3/4 30 63 26 21,5 10-150 4024052932511 3461-03.000

SW2*
)
Angle
H1
with Viega press connection 15 mm
d2
DN d2 l3 l4 H1 Flow EAN Article No
SW1*
)

54 range[l/h]
22

15 R1/2 29 58 23,5 10-150 4024052938018 3941-15.000


15
l3
l4

SW2*) Angle
H1 with male thread G 3/4
d2
DN d1 d2 l3 l4 H1 Flow EAN Article No
26
range[l/h]
d1 15 G3/4 R1/2 29 58 21,5 10-150 4024052930616 3935-02.000
l3
l4

SW1* SW2*) Straight


)

H2
D d2 DN D d2 l1 l2 H2 Flow EAN Article No
range[l/h]
l1
l2 10 Rp3/8 R3/8 59 85 21,5 10-150 4024052929511 3932-01.000
15 Rp1/2 R1/2 66 95 21,5 10-150 4024052929610 3932-02.000
20 Rp3/4 R3/4 74 106 23,5 10-150 4024052929917 3932-03.000

SW1*
)
SW2*
)
Straight
H2
with reduced lengths. Brass. Not suitable for compression fitting for multi layer pipes.
D d2
DN D d2 l1 l2 H2 Flow EAN Article No
l1
l2 range[l/h]
10 Rp3/8 R3/8 50 76 22,5 10-150 4024052932610 3462-01.000
15 Rp1/2 R1/2 55 83 22,5 10-150 4024052932719 3462-02.000
20 Rp3/4 R3/4 65 97 22,5 10-150 4024052932818 3462-03.000

*) S
 W1: DN 10 = 22 mm, DN 15 = 27 mm, DN 20 = 32 mm
SW2: DN 10 = 27 mm, DN 15 = 30 mm, DN 20 = 37 mm
Values H1 and H2 are at the bearing surface thermostatic head or actuator.

7
IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Eclipse

SW1*
)
SW2*
) Straight
H2 with Viega press connection 15 mm
d2
15

22 DN d2 l1 H2 Flow EAN Article No


l1
121 range[l/h]
15 R1/2 66 21,5 10-150 4024052938117 3942-15.000

SW2*
)
Straight
H2
with male thread G 3/4
d1 d2
DN d1 d2 H2 Flow EAN Article No
59
88 range[l/h]
15 G3/4 R1/2 21,5 10-150 4024052933013 3936-02.000

59

d2 Straight
SW2*
)
30 with bended nipple

DN D d2 l1 H2 Flow EAN Article No


range[l/h]
l1
15 Rp1/2 R1/2 66 21,5 10-150 4024052933013 3944-02.000
SW*1
)

D
H2

SW2*
)

Axial
d2
24 DN 10
27 DN 15

DN D d2 l3 l4 H1 Flow EAN Article No


*)
SW1
D
range[l/h]
l3
H1 l4 10 Rp3/8 R3/8 26 52 31,5 10-150 4024052929115 3930-01.000
15 Rp1/2 R1/2 29 58 31,5 10-150 4024052929214 3930-02.000

SW2*
) Axial
with reduced lengths. Brass. Not suitable for compression fitting for multi layer pipes.
22,0 DN 10
23,5 DN 15
26,0 DN 20

d2
DN D d2 l3 l4 H1 Flow EAN Article No
* )
SW1 range[l/h]
D
l3
H1 l4 10 Rp3/8 R3/8 24,5 50 34,5 10-150 4024052932016 3460-01.000
15 Rp1/2 R1/2 26 53 34,5 10-150 4024052932115 3460-02.000
20 Rp3/4 R3/4 30 63 34,5 10-150 4024052932214 3460-03.000

SW2*)
Axial
d2 with male thread G3/4
27

DN d1 d2 l3 l4 H1 Flow EAN Article No


d1
l3 range[l/h]
H1 l4
15 G3/4 R1/2 29 58 31,5 10-150 4024052930913 3937-02.000

*) S
 W1: DN 10 = 22 mm, DN 15 = 27 mm, DN 20 = 32 mm
SW2: DN 10 = 27 mm, DN 15 = 30 mm, DN 20 = 37 mm
Values H1 and H2 are at the bearing surface thermostatic head or actuator.

8
SW2*
)
Double angle
Connection to radiator left
d2

22 DN10
26 DN15
SW1*
) DN D d2 l3 l4 Flow EAN Article No
D range[l/h]
l3
l4 10 Rp3/8 R3/8 26 52 10-150 4024052931019 3933-01.000
15 Rp1/2 R1/2 29 58 10-150 4024052931217 3933-02.000

SW2*
)

Double angle
d2 with male thread G 3/4
26 Connection to radiator left
d1 DN d1 d2 l3 l4 Flow EAN Article No
l3
l4
range[l/h]
15 G3/4 R1/2 29 58 10-150 4024052931316 3938-02.000

SW2*
)

Double angle
d2 Connection to radiator right
22 DN10
26 DN15

SW1*
)

DN D d2 l3 l4 Flow EAN Article No


D
l4
l3 range[l/h]
10 Rp3/8 R3/8 26 52 10-150 4024052931118 3934-01.000
15 Rp1/2 R1/2 29 58 10-150 4024052931415 3934-02.000

SW2*
)

Double angle
d2 with male thread G 3/4
26 Connection to radiator right

d1 DN d1 d2 l3 l4 Flow EAN Article No


l3
l4 range[l/h]
15 G3/4 R1/2 29 58 10-150 4024052931514 3939-02.000

*) SW1: DN 10 = 22 mm, DN 15 = 27 mm, DN 20 = 32 mm


SW2: DN 10 = 27 mm, DN 15 = 30 mm, DN 20 = 37 mm
Values H1 and H2 are at the bearing surface thermostatic head or actuator.

9
IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Eclipse

Accessories

Setting key
for Eclipse. Color orange. EAN Article No
4024052937714 3930-02.142

Compression fitting
for copper or precision steel pipe Ø Pipe DN EAN Article No
according to DIN EN 1057/10305-1/2. 12 10 (3/8”) 4024052174614 2201-12.351
Female thread connection Rp 3/8 – 14 15 (1/2”) 4024052174713 2201-14.351
Rp 3/4. Metal-to-metal joint. 15 15 (1/2”) 4024052175017 2201-15.351
Brass nickel-plated. 16 15 (1/2”) 4024052175116 2201-16.351
Support sleeves should be used for a pipe 18 20 (3/4”) 4024052175215 2201-18.351
wall thickness of 0.8 – 1 mm. Follow the
specifications of the pipe manufacturer.

Support sleeve
for copper or precision steel pipe with a Ø Pipe L EAN Article No
1 mm wall thickness. 12 25,0 4024052127016 1300-12.170
Brass. 15 26,0 4024052127917 1300-15.170
16 26,3 4024052128419 1300-16.170
18 26,8 4024052128815 1300-18.170

Compression fitting
for Alu/PEX multi-layer pipe according to
DIN 16836. Ø Pipe EAN Article No
Female thread connection Rp 1/2. 16 x 2 4024052138616 1335-16.351
Nickel-plated brass.

Double connection fitting


For clamping plastic, copper, precision L EAN Article No
steel or multi-layer pipes. G3/4 x R1/2 26 4024052308415 1321-12.083
Brass, nickel-plated.

Compression fitting
for copper or precision steel pipe Ø Pipe EAN Article No
according to DIN EN 1057/10305-1/2. 12 4024052214211 3831-12.351
Connection male thread G 3/4 according 14 4024052214310 3831-14.351
to DIN EN 16313 (Eurocone). 15 4024052214617 3831-15.351
Metal-to-metal joint. Brass nickel-plated. 16 4024052214914 3831-16.351
With a pipe wall thickness of 0.8-1 mm 18 4024052215218 3831-18.351
insert supporting sleeves. Heed pipe
manufacturer’s technical advice.

Compression fitting
for copper or precision steel pipe Ø Pipe EAN Article No
according to DIN EN 1057/10305-1/2 and 15 4024052515851 1313-15.351
stainless steel pipe. 18 4024052516056 1313-18.351
Connection male thread G 3/4 according
to DIN EN 16313 (Eurocone).
Soft sealed, max. 95°C.
Nickel-plated brass.
10
Compression fitting
for plastic pipe according to DIN 4726, Ø Pipe EAN Article No
ISO 10508. 12x1,1 4024052136018 1315-12.351
PE-X: DIN 16892/16893, 14x2 4024052134618 1311-14.351
EN ISO 15875; 16x1,5 4024052136117 1315-16.351
PB: DIN 16968/16969. 16x2 4024052134816 1311-16.351
Connection male thread G3/4 according 17x2 4024052134915 1311-17.351
to DIN EN 16313 (Eurocone). 18x2 4024052135110 1311-18.351
Nickel plated brass.
20x2 4024052135318 1311-20.351

Compression fitting
for Alu/PEX multi-layer pipe according to Ø Pipe EAN Article No
DIN 16836. Connection male thread G3/4 16x2 4024052137312 1331-16.351
according to DIN EN 16313 (Eurocone). 18x2 4024052137411 1331-18.351
Nickel-plated brass.

Fitting tool
complete with case, box spanner EAN Article No
and replacement seals, for replacing Fitting tool 4024052298914 9721-00.000
thermostatic inserts without draining off
the heating system (for DN 10 to DN 20).

Measuring spindle for fitting tool


for differential pressure measurement at EAN Article No
thermostatic valve bodies with TA-SCOPE 4024052942114 9790-01.890
balancing instrument.

Replacement thermostatic insert


with automatic flow limiter for Eclipse. EAN Article No
4024052940912 3930-02.300

Other accessories, see catalogue leaflet “Accessories and spare parts for thermostatic radiator valves”.

11
IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Eclipse

The products, texts, photographs, graphics and diagrams in this document may be subject to
alteration by IMI Hydronic Engineering without prior notice or reasons being given. For the most up
to date information about our products and specifications, please visit www.imi-hydronic.com.
1217-18.483 EN Eclipse ed.3 01.2023

You might also like