0% found this document useful (0 votes)
17 views18 pages

Inec314 Approved Arch

Uploaded by

Umer Rashid
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
17 views18 pages

Inec314 Approved Arch

Uploaded by

Umer Rashid
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 18

FOR MUNICIPALITY USE

LAND AREA: 839.30m2


BUILT-UP AREA: 819 m2 PARKING STATEMENT
PERCENTAGE OF B.U.A: 83%

COVERED AREA & FEES SCHEDULE

X= 346365.2346
Y= 2802263.4463 X= 346348.3009
Plot Limit Plot Limit Y= 2802238.7478

90
°
83

°
+0.15 m Interlock Level +0.15 m Interlock Level 14/11/2023

2 1.20m PROJECTION LINE

GARDEN GARDEN

+18.55 m F.F.L
3D PERSPECTIVE
5.80
2
6.20

ROOF ACCESS AREA


35.38 m²
F-03
Service Cat Balcony +18.55 m F.F.L
Ladder to Roof
Balcony Outdoor sitting area
1.40
Outdoor sitting area SHARJAH MUNICIPALITY NOTES GENERAL NOTES SYMBOLS & ABBREVIATIONS
1.00
+18.55 m F.F.L F-02 OTS 2.10 1. ALL DIMENSIONS IN CM.
1.70 m² * ALL WINDOWS & BALCONY DOORS SHOULD BE
2. DO NOT SCALE FROM DRAWING.
EQUIPPED WITH WINDOWS OPENING CONTROL ELEVATION NUMBER
DEVICE (W.O.C.D) TO LIMITS THE OPENING LESS 3. ALL DIMENSIONS TO BE VERIFIED ON SITE
THAN 10CM CM TO HAVE MAXIMUM OPENING LIMIT 4. THIS DRAWING TO BE READ IN CONJUCTION
OF 10CM TO HELP IN THE PREVENTION OF WITH RELEVANT ARCH,STRUC & MEP SECTION NUMBER
ACCIDENTAL FALLS FROM WINDOWS AND BALCONY DETAILS & SPECIFICATIONS.
BY CHILDREN AS PER SHARJAH MUNICIPALITY 5. CONTRACTOR MUST CO-ORDINATE
REGULATION.
THESE DRAWINGS AND REPORT IF ANY LEVEL IN PLAN.

1.20m PROJECTION LINE


DISCREPANCY FOR CLARIFICATION BEFORE
PROCEEDING WITH THE WORK
+21.95 m ROOF *ALL EXTERNAL WALL ARE THERMAL INSULATION LEVEL IN ELEVATION & SECTION

S.S.L BLOCKS WITH MINIMUM 20cm THICKNESS 6. ALL MATERIAL TO BE APPROVED IN WRITEN
BY ENGINEER. FINISHING NOTATION

2 *ALL WINDOWS ARE REFLECTIVE, DOUBLE GLAZING 7. CONTRACTOR SHOULD SUBMIT THE
SHOP DRAWING FOR APPROVAL.
8. THE COPY RIGHTS OF THIS PLANS AND
WINDOW NOTATION

DRAWINGS ARE RESERVED FOR INVESTMENT DOOR NOTATION


ENGINEERING CONSULTANCY. 2007
LIFT TOP OF
GRP PANEL O.H.W.T
SLAB
5,000 UK GALLONS CAPACITY
0.88

Rest on 50cm Concrete base 2.00

1
1.40
+4.95 m F.F.L
L

OTS
VE

3.30
1.74

9.04 m²
TERLOCK LE

1.40
3.40
2
E
ECTION LIN

2.00
3
0.68
+0.15m IN

Balcony
4
3.40

6.46 m²
1.20m PROJ

F-03

+18.55 m F.F.L 5
15.21 m²
+4.95 m F.F.L +18.55 m F.F.L

Balcony
3.50

+21.95 m ROOF F-01


S.S.L
1.20
+18.55 m F.F.L Rev. No. REVISION Date Status
F-02
Balcony
Outdoor sitting area
1 DESIGN CONSULTANT:

INVESTMENT
OTS

X= 346338.2691
GARDEN GARDEN X= 346323.5587 Engineering Consultancy
97 Y= 2802255.7111
Y= 2802277.1660 °
°
90

Plot Limit
Plot Limit TEL : +971 6 5737979 FAX : +971 6 5737779
Balcony P.O.BOX : 1388, SHARJAH , UAE EMAIL : [email protected]
+18.55 m F.F.L
Outdoor sitting area www.investmentengineering.ae
+0.15 m Interlock Level 2.00m PROJECTION LINE F-01

2 +0.15 m Interlock Level


CLIENT'S :-
0.30

grass area grass area grass area grass area grass area grass area
MR. ABDULAZIZ ABDULLA AHMED MOHAMAD
AL ZAROONI
PROJECT TITLE :-

PROPOSED G+4+PENTHOUSE (50%) BUILDING


DWG. TITLE :

SETTING LAYOUT
MULK 118/3131
PLOT NO:- BLOCK:- MUWAILEH COMMERCIAL
GOV. 6086
SETTING LAYOUT DESIGNED BY:- CORDINATED BY:- APPROVED BY:- DRAWING NO. :-
ENGR. MARIA INEC TEAM E.KHALID ALZ
FACADE BY:- SCALE:- 1/100 DATE:- JOB NO. :-
ENGR. ALBATOUL SHEET SIZE: A2 18-06-2023 INV 314
FOR MUNICIPALITY USE

B
E4
Plot Limit Plot Limit

+0.15 m Interlock Level +0.15 m Interlock Level

1.80
7.116 3.70 3.70 1.20m PROJECTION LINE 3.70 3.80 4.30
14/11/2023
2.50 2.60 1.25 2.60 0.85 1.20 1.68 2.60 1.15 2.60 1.67 1.20 0.80 2.60 1.20

1.00

1.00

1.00

1.00
Plant Box Plant Box Plant Box Plant Box Plant Box
3.00
3.00 3.00 3.00

4.90 4.00

1.41
3.70 3.50 2.50
Plant Box

3.80
3.50

3.50

3.50

3.50

3.50

3.90
3.60
8.75 m²

3.00
1.20
19.92 m² 14.35 m² 8.75 m² 21.24 m² 20.65 m² 14.00 m²
5.00

5.00
vel

5.50
Interlock Le
1.00
+0.75 m F.F.L
4.44 4.10 2.50
+0.75 m F.F.L

7.00
3
1.90

0.60
Closet 3.60
+0.15 m

2.20
1.20

0.80
1.20

1.20

1.20
Cabinet

1.10
2.52 m² 2.42 m²
3.13

1.90
1.00 2.20 5.10 4.32 m² Common Toilet

2.50

2.50

2.30

2.00 Level

1.20
1.20

4.14 m²

1.70
7.50 m² OTS 3.50

+0.15 m Interlock
Passage 1.80 1.85 1.55 2.90
1.70 m² F-02
+0.75 m

1.90
1.56 m²

2.20
F.F.L 4.00m²

2.00
3.80 +0.75 m F.F.L Watchman's Room

0.80
2.50
2.40

2.40
3.18 m²
1.21

1.30
1.00 7.25 m²
5.99 2.10 F-01

0.70
+0.30m F.F.L
4.28 m²

0.20 0.90
4.30

4.30
1.45

3.10

3.10
3.50
11.78 m²

0.40
2.70

1.20
Plant Box +0.75 m F.F.L

1.80
1.75m Corridor

3.50
F-03 +0.45m F.F.L

1.20m PROJECTION LINE


20.15 m²
2.60

7.30 RAMP UP

1.50

1.50

1.50
chute Garbage Trolley Passage
+0.75 m F.F.L 5.30 2.00 2.80 3.60 3 nos. 1 BEDROOM FLAT
E

1.00 6.40
JECTION LIN

5.53 2.70 1.20 1.20 2.30 6 nos. SHOPS

3.87
2.20
6.00

1.60

4.83
4.50
Garbage Room

1.90
2.20
3.50

1.87
4.83 m² +0.45m F.F.L
Pump Room
1.20m PRO

1.01
1.20

1.20

2.70 UP
7.75m ramp Lenght 2.00
slope 1:12 3.90
100 GPM FIRE FIGHTING PUMP SET

4.50
+0.75 m F.F.L +0.45m LEVEL

4.70
R.C.C U/G.W.T WITH TOTAL

1.20
1.21 0.94 1.20
4.70

1.70 2.00

4.50
A 2.20 A
3.50
4.39

1.00 CAPACITY OF 11,500 UK GALS


1.10

3.70

1.00
9.50

1.10
Plant Box U/G.W.T AREA=43.68 m² 9.20 m² 13.04 m² OTS +0.75 m F.F.L
Transformer Room
3.10

+0.75 m F.F.L
Gas Mt. Rm SHARJAH MUNICIPALITY NOTES GENERAL NOTES SYMBOLS & ABBREVIATIONS

2.50
LIQUID DEPTH = 1.20m
2.50

2.00
2.50

E2 TOTAL DEPTH = 1.50m

0.54
4.41 m² 1. ALL DIMENSIONS IN CM.
5.00 6.90 * ALL WINDOWS & BALCONY DOORS SHOULD BE
1.20

2. DO NOT SCALE FROM DRAWING.


EQUIPPED WITH WINDOWS OPENING CONTROL ELEVATION NUMBER

1.00
Ramp up +0.75 m F.F.L

1.74

1.50
DEVICE (W.O.C.D) TO LIMITS THE OPENING LESS 3. ALL DIMENSIONS TO BE VERIFIED ON SITE

8.70

1.20
0.60 THAN 10CM CM TO HAVE MAXIMUM OPENING LIMIT
+0.75 m F.F.L 4. THIS DRAWING TO BE READ IN CONJUCTION

0.30
OF 10CM TO HELP IN THE PREVENTION OF

2.53
WITH RELEVANT ARCH,STRUC & MEP SECTION NUMBER
ACCIDENTAL FALLS FROM WINDOWS AND BALCONY DETAILS & SPECIFICATIONS.
BY CHILDREN AS PER SHARJAH MUNICIPALITY 5. CONTRACTOR MUST CO-ORDINATE

1.50
REGULATION.
2.70 2.25 4.50 THESE DRAWINGS AND REPORT IF ANY LEVEL IN PLAN.
DISCREPANCY FOR CLARIFICATION BEFORE
+0.45m F.F.L PROCEEDING WITH THE WORK
E3 LEVEL IN ELEVATION & SECTION
vel

*ALL EXTERNAL WALL ARE THERMAL INSULATION


Main Lobby
Interlock Le

BLOCKS WITH MINIMUM 20cm THICKNESS 6. ALL MATERIAL TO BE APPROVED IN WRITEN


Main Entrance UP

3.65
Electrical Room

3.00
BY ENGINEER. FINISHING NOTATION
33.44 m²
1.50 2.25
4.10

4.10

15.28 m² *ALL WINDOWS ARE REFLECTIVE, DOUBLE GLAZING 7. CONTRACTOR SHOULD SUBMIT THE
+0.75 m F.F.L
3.90

3.90
step up +0.75 m F.F.L
4.14

1.20

1.80
SHOP DRAWING FOR APPROVAL.
+0.75m F.F.L WINDOW NOTATION

+0.15 m Interlock Level


8. THE COPY RIGHTS OF THIS PLANS AND
Telephone Room
+0.15 m

4.48
Exit DRAWINGS ARE RESERVED FOR INVESTMENT DOOR NOTATION

4.83
ENGINEERING CONSULTANCY. 2007
+0.75 m F.F.L
+0.45m F.F.L
12.18
3.48 8.50 1.20

0.27
RAMP UP 1

1.50

1.50
1.50 1.50 1.90 1.50 1.90 1.50
2.95 8.90 2

1.20
13.04 m²
1.40

1.40

1.40
1.50

1.50

1.50

2.70
Plant Box
Toilet Toilet Toilet 3

0.80
3.60 BC
3.00

1.60 1.60 1.60 4


4.00

4.00
1.95

0.85
1.00 Gas duct
5

4.10 3.50 3.50 3.50 3.60 4.10


8.70

8.70

8.70
9.18

Rev. No. REVISION Date Status


7.75

7.75

7.75

8.15
7.40
7.20

7.20

7.20

DESIGN CONSULTANT:

5.80
INVESTMENT
4.90

4.90
Plant Box
0.20 0.30 0.30 0.30 0.40 0.40
+0.30 m F.F.L +0.30 m F.F.L +0.30 m F.F.L +0.30 m F.F.L +0.30 m F.F.L +0.30 m F.F.L
4.08

1.00
1.80 1.20 1.80 1.20 1.80 1.20 1.80 1.20 1.80 1.20 1.80 1.20 Engineering Consultancy
Plot Limit
Plot Limit
TEL : +971 6 5737979 FAX : +971 6 5737779
1.20

1.20

1.20

+0.15 m Interlock
Plant Box Plant Box Plant Box Plant Box 1.20 +0.15 m Interlock P.O.BOX : 1388, SHARJAH , UAE EMAIL : [email protected]
Level Plant Box Level Plant Box www.investmentengineering.ae
0.38 3.00 0.70 3.00 0.70 3.00 0.70 3.00 0.80 3.00 0.80 3.00 0.90
2.00m PROJECTION LINE CLIENT'S :-
1.35

1.35

+0.15 m Interlock +0.15 m Interlock


1.65

Level Level
MR. ABDULAZIZ ABDULLA AHMED MOHAMAD
0.30

0.30

grass area grass area


2.40
grass area grass area grass area grass area AL ZAROONI
PROJECT TITLE :-

PROPOSED G+4+PENTHOUSE (50%) BUILDING


B

3.597 3.70 3.70 3.70 3.80 4.30


DWG. TITLE :

GROUND FLOOR PLAN


GROUND FLOOR PLAN +0.00 m Road Level
MULK 118/3131
PLOT NO:- BLOCK:- MUWAILEH COMMERCIAL
E1 GOV. 6086
DESIGNED BY:- CORDINATED BY:- APPROVED BY:- DRAWING NO. :-
ENGR. MARIA INEC TEAM E.KHALID ALZ
FACADE BY:- SCALE:- 1/100 DATE:- JOB NO. :-
ENGR. ALBATOUL SHEET SIZE: A2 18-06-2023 INV 314
FOR MUNICIPALITY USE
E4

B
7.116 3.70 3.70 3.70 3.80 4.30
Plot Limit Plot Limit
14/11/2023

3.14 2.60 0.20 1.05 2.60 0.85 1.20 1.00 0.68 2.60 1.15 2.60 0.67 1.00 1.20 0.80 2.60 1.20
3.50 3.00 0.20 1.05 5.65 7.70 5.68 2.32

0.10
Plant Box Plant Box

1.20
1.10

1.10

1.10
+4.95 m F.F.L Plant Box
6.71 m² 3.30 m² 1.04 m² 6.22 m² +4.95 m F.F.L 6.25 m²
+4.95 m F.F.L 8.49 m²

3.60 3.50

1.20
5.51 4.10 4.00

1.41
2.50 C

4.70

4.70

1.20
21.24 m²

3.50

3.50

3.50

3.50
5.90

5.90
1.20

6.80
19.92 m² 14.35 m² 8.75 m² 20.65 m² 8.75 m²
14.00 m²

4.70
5.00

5.00
7.46
+4.95 m F.F.L +4.95 m F.F.L 2.50

1.55
5.05

1.90
0.50 1.20
3

0.60
Closet

0.60
1.20

1.20

1.20

1.20

1.20
0.60 4.32 m² 4.92 m² 4.14 m²

1.80
3.73 3.60 4.10
1.00 2.30

2.50

2.30
1.20

1.20 4.14 m² F-03 F-02

1.70
OTS
8.77 m²

2.15
1.30
1.70 m²
5.10

0.20
Passage

1.20
1.80

1.30
3.42 1.56 m² +0.75 m
4.18 m²
2.04 m² 6.00 F-01
0.74 0.47

2.20

2.00
F.F.L
1.70
0.10

1.70 +4.95 m F.F.L


2.89
5.50
1.20 1.41
2.00 1.70 +4.95 m F.F.L
1.10
2

0.70
1.30
0.90

1.40
4.30

4.10

4.30
2.30 m²

1.35
2.06 m² 1.19 m²

3.50
1.59 chute 25.13 m²

0.75
9 nos. 1 BEDROOM FLAT

2.60
1.20
0.72 m²
3.50
1.69

1.50

1.50
3.53

21.99 m²
2.60

3.88 m² F-04 5.85 m² UP DN 5.80

5.55
6.11 m²

0.27
+4.95 m F.F.L 4.10 2.80

2.10
+4.95 m
F.F.L F-05
1.10 4.70
+4.95 m
F.F.L D

0.20
2.50
6.73

3.10
4.83
1.50
0.20

8.26 m²

1.25
Passage
1.15

2.20

2.20

1.80
8.41

2.50
4.83 m² 1.20 1.20 1.56 m²

1.60
2.20 2.10
+4.95 m F.F.L

3.50
+4.95 m SHARJAH MUNICIPALITY NOTES GENERAL NOTES SYMBOLS & ABBREVIATIONS
2.60 2.70 1.90 15.25 m²

1.20
F.F.L
A A
4.70

4.70
0.90
1. ALL DIMENSIONS IN CM.
3.50

2.15
* ALL WINDOWS & BALCONY DOORS SHOULD BE
3.53

0.88
2. DO NOT SCALE FROM DRAWING.
13.04 m² 4.50
2.60

1.65
24.451 m² +0.75 m EQUIPPED WITH WINDOWS OPENING CONTROL ELEVATION NUMBER
50.60 m² 3. ALL DIMENSIONS TO BE VERIFIED ON SITE
F.F.L DEVICE (W.O.C.D) TO LIMITS THE OPENING LESS
Plant Box

2.00

2.00

0.80 0.20 0.80


3.88 m²
5.34 1.90 4.41 m² 1.40 1.40 2.00
THAN 10CM CM TO HAVE MAXIMUM OPENING LIMIT 4. THIS DRAWING TO BE READ IN CONJUCTION
4.00 m² 1.71 m² OF 10CM TO HELP IN THE PREVENTION OF WITH RELEVANT ARCH,STRUC & MEP SECTION NUMBER

16.20
ACCIDENTAL FALLS FROM WINDOWS AND BALCONY

0.20
DETAILS & SPECIFICATIONS.
4.14 1.20

3.30
2.20

1.74
9.04 m² BY CHILDREN AS PER SHARJAH MUNICIPALITY

3.20
5. CONTRACTOR MUST CO-ORDINATE
3.40 1.90 REGULATION.
THESE DRAWINGS AND REPORT IF ANY LEVEL IN PLAN.
+4.95 m

E2 8.00 m² 2.44 m² F.F.L


E3 DISCREPANCY FOR CLARIFICATION BEFORE

38
1.40

19.00m TRAVEL DISTANCE BETWEEN 2nos. STAIRCASE


1.29

0.60 4.22 1.60 PROCEEDING WITH THE WORK

.92
LEVEL IN ELEVATION & SECTION
Plant Box

2.00
*ALL EXTERNAL WALL ARE THERMAL INSULATION
2.00
1.20

2.30
1.20
6. ALL MATERIAL TO BE APPROVED IN WRITEN
2.50 2.64 m² 4.50 2.09 m²
BLOCKS WITH MINIMUM 20cm THICKNESS

0.68
BY ENGINEER. FINISHING NOTATION

1.30
0.50 1.92 m² 2.20 4.37 m²
*ALL WINDOWS ARE REFLECTIVE, DOUBLE GLAZING
2.70 7. CONTRACTOR SHOULD SUBMIT THE

1.20
SHOP DRAWING FOR APPROVAL. WINDOW NOTATION

3.90
17.55 m² 8. THE COPY RIGHTS OF THIS PLANS AND
1.00

16.20 m² 4.15
0.90

DRAWINGS ARE RESERVED FOR INVESTMENT DOOR NOTATION


2.25 m² ENGINEERING CONSULTANCY. 2007
4.10

4.10

Plant Box 2.10 1.20


4.24

2.60

+4.95 m
3.90

3.90
2.12 m² 1.20 1.20

2.00

1.80
F.F.L

1.50
2.25 9.11 m² Passage
2.70

3.05
1.75 m²

4.83
5.23 m²

2.50
4.15
1
D
1.80

4.05 m² 8.16 m²

0.20
3.68
2

4.75
1.15 2.70 2.80 1.10 4.70
1.08
0.20

DN UP
5.80 3
4.55 1.00

2.60
1.20
4

1.00
0.90
2.70
1.05

13.04 m² FHC 1.70 m²

3.50
7.50 m² 1.70
2.00

+4.95 m
+4.95 m
F.F.L 4.20 m² 20.86 m² F.F.L 5
2.10 2.80 +4.95 m F.F.L 1.10
3.50

+4.95 m F.F.L
4.00

4.00
3.53

1.40
F-09

1.05 0.20 0.90

0.20 0.85
2.00
3.88 m² 15.13 m² Plant Box
5.90
2.50

2 0.83 m²
1.30

1.30

6.63 m² F-06 7.20


4.09 5.10
F-07 F-08 OTS
1.50 m²
0.10

0.90 1.50 Rev. No. REVISION Date Status

1.50

1.80
1.20 1.10 2.50
C
1.00
1.00
1.00
1.75 m² 1.00
4.08 1.30
1.20

4.50 m²
1.60

1.80 1.30 DESIGN CONSULTANT:


1.50

+4.95 m +4.95 m

3.10
1.60 m² F.F.L

1.20
Passage
2.20

F.F.L 2.60
2.00

1.92 m² OTS 7.75 m²


2.53

1.76 m² 1.50 m² 4.00 m² 1.60 1.50


1.10

+4.95 m F.F.L 2.00 Passage


INVESTMENT

1.20
2.97 m²
1.92 m²

1.35
2.00 1.40
4.90

4.90
1.20

1.20

Plant Box Passage Passage


6.10
6.00

8.29 m²
22.11 m²
2.40 m² 4.10
1.20

1.68 m²

8.00
5.00

1.20
17.50 m²
4.80

4.80
18.47 m²
Engineering Consultancy
7.26

4.30

3.90

3.54 15.05 m² 3.50 3.50 3.60

3.60

3.50
+4.95 m F.F.L +4.95 m F.F.L 14.35 m²
TEL : +971 6 5737979 FAX : +971 6 5737779
2.50
2.60

8.75 m² P.O.BOX : 1388, SHARJAH , UAE EMAIL : [email protected]

2.10
Plot Limit Plot Limit www.investmentengineering.ae
3.29 3.50
CLIENT'S :-

Plant Box
MR. ABDULAZIZ ABDULLA AHMED MOHAMAD
1.00

1.00

1.00

1.10
3.00 m²
+4.95 m +4.95 m Plant Box 3.50 m²
+4.95 m +4.95 m
6.55 m² 10.14 m²
F.F.L 3.50 m² F.F.L 3.70 m² F.F.L F.F.L
AL ZAROONI
0.10

1.53 3.00 3.50


2 3.90 3.50 0.20 6.55 2.75 PROJECT TITLE :-

0.87 2.60 0.20 0.90 2.60 1.35 1.20 1.80 2.60 0.45 0.45 2.60 0.75 2.60 1.70 1.20
PROPOSED G+4+PENTHOUSE (50%) BUILDING
A B A B A DWG. TITLE :

TYPICAL 1ST-4TH FLOOR PLAN


B

TYPICAL 1ST- 4TH FLOOR PLAN 3.597 3.70 3.70 3.70 3.80 4.30

PLOT NO:-
MULK 118/3131
BLOCK:- MUWAILEH COMMERCIAL
GOV. 6086
DESIGNED BY:- CORDINATED BY:- APPROVED BY:- DRAWING NO. :-
E1 ENGR. MARIA INEC TEAM E.KHALID ALZ
FACADE BY:- SCALE:- 1/100 DATE:- JOB NO. :-
ENGR. ALBATOUL SHEET SIZE: A2 18-06-2023 INV 314
FOR MUNICIPALITY USE

B
E4
Plot Limit Plot Limit
14/11/2023

1.20

1.20
11.90

GARDEN

3.20
45.96 m²

4.40
6.460 3.70 3.70 3.70 3.80 4.30
GARDEN
58.43 m²
ROOF ACCESS AREA

7.72 3.50
31.11 m²

+18.55 m F.F.L
3.70

Balcony
F-03
8.00

+18.55 m F.F.L
3

3.00
5.10 Outdoor sitting area
Balcony 1.40 2.10 Service Cat 24.00m²
Outdoor sitting area Ladder to Roof

3.00

3.00
22.08 m² 1.00 3.00 1.00 6.20 2.60 3.20
Exit
OTS
F-02

1.70

0.93
+18.55 m F.F.L 1.70 m² 1.70 +18.55 m F.F.L
+0.75 m 7.60
6.00

1.20
1.72 2.60 5.40

1.30

1.30
F-03

2.00
1.20
1.90
0.72

8.89

1.00
1.00 1.20 1.80

0.70

2.60
4.10

4.30
Toilet

1.35
23.37 m²
0.90 2.43 m²
3nos. 2 BEDROOM FLAT

0.75
2.40 chute +18.55 m F.F.L

1.20
2.70 0.72 m²
3.50

1.50
30.30 m² F-02
2.60

+18.55 m F.F.L
4.40 DN 5.70
+18.55 m F.F.L
8.43 1.50m Corridor
1.10 4.60

1.67
2.45
2.20
4.63 1.20 2.60

3.10
4.83
8.54 m²
1.13

1.20
2.00 Passage

2.20
4.00 0.50
0.50 2.90
4.83 m² 1.20 1.20 2.20

1.10
1.20
4.50 1.50 Closet 2.20 m² 2.10

16.00m TRAVEL DISTANCE BETWEEN 2nos. STAIRCASE


14.00 m²
1.80 1.10 SHARJAH MUNICIPALITY NOTES GENERAL NOTES SYMBOLS & ABBREVIATIONS
Closet

4.00

2.60

4.70
1.20
2.60

1. ALL DIMENSIONS IN CM.


A 3.50
A
3.50

* ALL WINDOWS & BALCONY DOORS SHOULD BE

2.20
2.20 Passage 2. DO NOT SCALE FROM DRAWING.
ELEVATION NUMBER

0.88
EQUIPPED WITH WINDOWS OPENING CONTROL

14.00
13.04 m² DEVICE (W.O.C.D) TO LIMITS THE OPENING LESS 3. ALL DIMENSIONS TO BE VERIFIED ON SITE
2.00
5.00
THAN 10CM CM TO HAVE MAXIMUM OPENING LIMIT 4. THIS DRAWING TO BE READ IN CONJUCTION

2.00
1.40 1.00
1.90

9.50 m² 4.41 m² 1.40 OTS OF 10CM TO HELP IN THE PREVENTION OF WITH RELEVANT ARCH,STRUC & MEP SECTION NUMBER
14.15 m² 4.00 m² ACCIDENTAL FALLS FROM WINDOWS AND BALCONY DETAILS & SPECIFICATIONS.
9.04 m²

3.80
BY CHILDREN AS PER SHARJAH MUNICIPALITY

3.30

0.35 0.90
Passage 5. CONTRACTOR MUST CO-ORDINATE

1.74
+4.95 m F.F.L

1.74
4.04 REGULATION.
Closet THESE DRAWINGS AND REPORT IF ANY LEVEL IN PLAN.

E2 2.72
2.50
2.44 m² 1.40
3.40 5.00 1.50 1.20 *ALL EXTERNAL WALL ARE THERMAL INSULATION
DISCREPANCY FOR CLARIFICATION BEFORE
PROCEEDING WITH THE WORK LEVEL IN ELEVATION & SECTION
1.94

0.60

1.20 BLOCKS WITH MINIMUM 20cm THICKNESS 6. ALL MATERIAL TO BE APPROVED IN WRITEN
Closet

1.20
2.64 m² 2.00 BY ENGINEER. FINISHING NOTATION

0.68
2.70 *ALL WINDOWS ARE REFLECTIVE, DOUBLE GLAZING 7. CONTRACTOR SHOULD SUBMIT THE
2.20 17.50 m² SHOP DRAWING FOR APPROVAL.

1.20
WINDOW NOTATION
3.85
2.00 Balcony 8. THE COPY RIGHTS OF THIS PLANS AND

2.60
3.50

3.50

3.40
2.10 9.18 m² DRAWINGS ARE RESERVED FOR INVESTMENT DOOR NOTATION
3.90 E3 ENGINEERING CONSULTANCY. 2007

0.27
F-03

3.90
1.90

2.05
2.60

4.10 m² 5.00
19.44 m² 4.00 m²
5.30

+4.95 m F.F.L +18.55 m F.F.L

0.27
0.80
0.90
4.70

4.83
1
3.90

3.90

1.00
1.20 1.20
2.10 15.21 m² +18.55 m F.F.L 2

0.27
3.51 Closet

0.60
DN 3
1.90

0.60 1.50

1.90
4.00 m² +18.55 m F.F.L
1.62

Balcony 4

1.20

1.30
0.85
Closet

2.95
3.90
0.80

9.30 m²

2.60
3.50
13.04 m² 2.10

3.60

3.60
0.10
F-01
F-01
5

0.70
0.90 2.60 2.40 2.40
0.60

+18.55 m F.F.L

4.00
1.00
2.60

1.70
0.30
F-02 18.00 m²
5.00
2.40

0.55
+18.55 m F.F.L 0.80
Gas Riser
3.00

11.50 m²
Balcony
1.70

1.70

1.77
Outdoor sitting area 5.00 1.00
31.06 m² Rev. No. REVISION Date Status

4.60
OTS

1.50

1.80

1.80

1.80
1.50 m²
5.31 Toilet 1.20 4.32 m²
1.30 4.68 m² DESIGN CONSULTANT:

0.60
2.40
1.50

1.10

OTS 2.42 m²
1.50 m²
+18.55 m F.F.L
5.30 2.20 2.60
1.00 Laundry
7.40

INVESTMENT
5.20
1.20

1.20
Passage

1.10

2.00
25.36m² 3.90 1.60
2.20
5.00

1 0.60

4.90
Maid's Rm.
1.30 Plant Box

3.90
3.70

GARDEN 3.60 14.00 m² 9.84 m²

1.20
GARDEN Engineering Consultancy
2.70

2.70
33.31 m² 3.41 m² Kitchen
31.67 m² 3.50 Closet

TEL : +971 6 5737979 FAX : +971 6 5737779


0.50 3.60

1.20
P.O.BOX : 1388, SHARJAH , UAE EMAIL : [email protected]
Plot Limit www.investmentengineering.ae
Plot Limit
0.65 2.60 1.15 1.20 0.90 0.60 1.70 1.20 2.40 2.60 0.70 CLIENT'S :-

Balcony Outdoor sitting area


F-01
15.50 31.00 m²
+18.55 m F.F.L
1.30 MR. ABDULAZIZ ABDULLA AHMED MOHAMAD
AL ZAROONI
PROJECT TITLE :-

PROPOSED G+4+PENTHOUSE (50%) BUILDING


DWG. TITLE :
B

E1 PENTHOUSE PLAN
PENTHOUSE PLAN (50%) 3.597 3.70 3.70 3.70 3.80 4.30
MULK 118/3131
PLOT NO:- BLOCK:- MUWAILEH COMMERCIAL
GOV. 6086
DESIGNED BY:- CORDINATED BY:- APPROVED BY:- DRAWING NO. :-
ENGR. MARIA INEC TEAM E.KHALID ALZ
FACADE BY:- SCALE:- 1/100 DATE:- JOB NO. :-
ENGR. ALBATOUL SHEET SIZE: A2 18-06-2023 INV 314
FOR MUNICIPALITY USE

E4

B
Plot Limit Plot Limit
14/11/2023

2.50
GARDEN

4.40
44.20 m²
GARDEN
5.80 2.90 8.10

6.20
3
58.43 m²
ROOF ACCESS AREA

7.40
35.38 m²

+18.55 m F.F.L

3.70
Service Cat Balcony Outdoor sitting area
Ladder to Roof 24.00m²
Balcony +18.55 m F.F.L
1.40
Outdoor sitting area
22.08 m²
1.00
+18.55 m F.F.L OTS 2.10
1.70 m²

chute
cover 3nos. 2 BEDROOM FLAT

2.60 +21.95 m ROOF


S.S.L
5.00

GRP PANEL O.H.W.T LIFT TOP OF


1 SHARJAH MUNICIPALITY NOTES GENERAL NOTES SYMBOLS & ABBREVIATIONS

4.80
1.50 SLAB 1. ALL DIMENSIONS IN CM.
A 5,000 UK GALLONS CAPACITY A
4.00

2.00 * ALL WINDOWS & BALCONY DOORS SHOULD BE


2. DO NOT SCALE FROM DRAWING.
EQUIPPED WITH WINDOWS OPENING CONTROL ELEVATION NUMBER
Rest on 50cm Concrete base DEVICE (W.O.C.D) TO LIMITS THE OPENING LESS 3. ALL DIMENSIONS TO BE VERIFIED ON SITE
THAN 10CM CM TO HAVE MAXIMUM OPENING LIMIT 4. THIS DRAWING TO BE READ IN CONJUCTION
OF 10CM TO HELP IN THE PREVENTION OF
TO BE COVERED BY ALUMINUM MESH +24.15 m OTS ACCIDENTAL FALLS FROM WINDOWS AND BALCONY
WITH RELEVANT ARCH,STRUC & MEP
DETAILS & SPECIFICATIONS.
SECTION NUMBER

TANK SIZE= 5.00x4.00x1.50m HEIGHT BY CHILDREN AS PER SHARJAH MUNICIPALITY

3.30
S.S.L 5. CONTRACTOR MUST CO-ORDINATE

1.74
9.04 m² REGULATION.
THESE DRAWINGS AND REPORT IF ANY LEVEL IN PLAN.
LIQUID HEIGHT= 1.20m 3.40 DISCREPANCY FOR CLARIFICATION BEFORE

E2 *ALL EXTERNAL WALL ARE THERMAL INSULATION


BLOCKS WITH MINIMUM 20cm THICKNESS
PROCEEDING WITH THE WORK
6. ALL MATERIAL TO BE APPROVED IN WRITEN
LEVEL IN ELEVATION & SECTION

1.20
BY ENGINEER. FINISHING NOTATION
2.00
*ALL WINDOWS ARE REFLECTIVE, DOUBLE GLAZING 7. CONTRACTOR SHOULD SUBMIT THE
SHOP DRAWING FOR APPROVAL.
+21.95 m ROOF Balcony 8. THE COPY RIGHTS OF THIS PLANS AND
WINDOW NOTATION

S.S.L

3.40
9.18 m² DRAWINGS ARE RESERVED FOR INVESTMENT DOOR NOTATION
3.90 ENGINEERING CONSULTANCY. 2007
E3
+18.55 m F.F.L
1
3.90

15.21 m² 2
+18.55 m F.F.L
3
Balcony 4
9.30 m²

3.50
+21.95 m ROOF 5
S.S.L
+18.55 m F.F.L

Balcony 1.00
31.06 m²
Outdoor sitting area OTS Rev. No. REVISION Date Status

1.50
1.50 m²

OTS DESIGN CONSULTANT:

INVESTMENT
Engineering Consultancy
GARDEN GARDEN TEL : +971 6 5737979 FAX : +971 6 5737779
33.31 m²
31.67 m² P.O.BOX : 1388, SHARJAH , UAE EMAIL : [email protected]
Plot Limit www.investmentengineering.ae
Plot Limit
CLIENT'S :-
Balcony
Outdoor sitting area
31.00 m² +18.55 m F.F.L MR. ABDULAZIZ ABDULLA AHMED MOHAMAD
F-01
AL ZAROONI
PROJECT TITLE :-

PROPOSED G+4+PENTHOUSE (50%) BUILDING


DWG. TITLE :
B

E1 ROOF PLAN
ROOF PLAN MULK 118/3131
PLOT NO:- BLOCK:- MUWAILEH COMMERCIAL
GOV. 6086
DESIGNED BY:- CORDINATED BY:- APPROVED BY:- DRAWING NO. :-
ENGR. MARIA INEC TEAM E.KHALID ALZ
FACADE BY:- SCALE:- 1/100 DATE:- JOB NO. :-
ENGR. ALBATOUL SHEET SIZE: A2 18-06-2023 INV 314
FOR MUNICIPALITY USE

14/11/2023

4 NOTE :
All Windows & Balcony Doors Should Be
Equipped with Windows Opening Control
+24.45 m TOP OF PARAPET
Device (W.O.C.D) To Limits the Opening
Less Than 10cm to have Maximum Opening
Limit of 10cm to help in the Prevention of
2.50

2.50
2 2

2.70

2.70
2
Accidental Falls from Windows & Balcony
by Children as per Sharjah Municipality
+21.95 m ROOF Regulation

0.10
S.S.L
0.60 0.60
2.20

2.00
1.70
4 4 4 4 4
2

1.70
2 2 2 2 2

3.40
Fix S S Fix S Fix 1-TRAVERTINE

0.60
4 4 4 5
5 2 -STONE PAINT

0.60
3 SIGNAGE WITH LED LIGHTS
1.20

1.20
1.70

1.70
1.20
+18.55m PENTHOUSE FLOOR
F.F.L

1.10
1 1 4- REFLECTIVE POWDER COATED
0.50

0.50
ALUMINIUM FRAMED DOUBLE GLAZING
4 4 4 4 5-PREFABRICATED ALUMINUM HANDRAIL WITH
4
1.70

1.70
1.70

1.70
2 2 2 2 WROUGHT IRON GRILLS

3.40
Fix S Fix S S Fix S Fix S Fix
5 4 4 4 4 4 5 6- EMULSION PAINT RAL 780-1

0.60
1.20
1.70

1.70
1.20

1.20
+15.15m FOURTH FLOOR
1 1 F.F.L

1.10
0.50

0.50
SHARJAH MUNICIPALITY NOTES GENERAL NOTES SYMBOLS & ABBREVIATIONS
1. ALL DIMENSIONS IN CM.
4 4 4 4 1.20 * ALL WINDOWS & BALCONY DOORS SHOULD BE
2. DO NOT SCALE FROM DRAWING.
1.70

1.70
2 2 EQUIPPED WITH WINDOWS OPENING CONTROL ELEVATION NUMBER
1.70

1.70
2 2 DEVICE (W.O.C.D) TO LIMITS THE OPENING LESS 3. ALL DIMENSIONS TO BE VERIFIED ON SITE

3.40
Fix S Fix S S Fix S Fix S Fix THAN 10CM CM TO HAVE MAXIMUM OPENING LIMIT 4. THIS DRAWING TO BE READ IN CONJUCTION
OF 10CM TO HELP IN THE PREVENTION OF WITH RELEVANT ARCH,STRUC & MEP
4 4 4 4 4 ACCIDENTAL FALLS FROM WINDOWS AND BALCONY DETAILS & SPECIFICATIONS.
SECTION NUMBER

5 5 BY CHILDREN AS PER SHARJAH MUNICIPALITY 5. CONTRACTOR MUST CO-ORDINATE

0.60
24.30

24.30
REGULATION.
THESE DRAWINGS AND REPORT IF ANY LEVEL IN PLAN.
1.20

1.20
1.70

1.70
DISCREPANCY FOR CLARIFICATION BEFORE
1.20

+11.75m THIRD FLOOR *ALL EXTERNAL WALL ARE THERMAL INSULATION


PROCEEDING WITH THE WORK LEVEL IN ELEVATION & SECTION
1 1 F.F.L

1.10
BLOCKS WITH MINIMUM 20cm THICKNESS 6. ALL MATERIAL TO BE APPROVED IN WRITEN
BY ENGINEER. FINISHING NOTATION
0.50

0.50
*ALL WINDOWS ARE REFLECTIVE, DOUBLE GLAZING 7. CONTRACTOR SHOULD SUBMIT THE
SHOP DRAWING FOR APPROVAL. WINDOW NOTATION

4 4 4 4 4 1.20 8. THE COPY RIGHTS OF THIS PLANS AND


1.70

1.70
DRAWINGS ARE RESERVED FOR INVESTMENT DOOR NOTATION
2
1.70

1.70
2 2 2 ENGINEERING CONSULTANCY. 2007

3.40
Fix S Fix S S Fix S Fix S Fix
5 4 4 4 4 4
5

0.50
1
1.20

1.20

1.20

1.20
1.70

1.70
+8.35m SECOND FLOOR 2
1 1 F.F.L

1.10
0.50

0.50
3
4 4 4 4 1.20 4
4
1.70

1.70
2
1.70

1.70
2 2 2 5

3.40
Fix S Fix S S Fix S Fix S Fix
4 4 4 4 4
5 5

1.20
1.20

+4.95m FIRST FLOOR

0.30 0.60

0.90
F.F.L
2.80

2.80
0.30

2.20
1 1 Rev. No. REVISION Date Status
1.60

1.30
DESIGN CONSULTANT:
LEVEL 1.20

4.20
0.75
4 3 3 3 3 3
INVESTMENT

4.65
4
4.35

4.35

1
1
3.20

3.20
Fix Fix Fix Fix Fix Fix
3.20

1 1 1
1 4 1
1.20

2.30
+0.75m GROUND FLOOR F.F.L
+0.15m INTERLOCK Engineering Consultancy
0.90

0.90

0.60
0.60

+0.30m F.F.L

0.15
+0.15m INTERLOCK LEVEL
0.15

0.15

TEL : +971 6 5737979 FAX : +971 6 5737779


P.O.BOX : 1388, SHARJAH , UAE EMAIL : [email protected]
www.investmentengineering.ae

CLIENT'S :-

MR. ABDULAZIZ ABDULLA AHMED MOHAMAD


FRONT ELEVATION PROJECT TITLE :-
AL ZAROONI

E1 PROPOSED G+4+PENTHOUSE (50%) BUILDING


DWG. TITLE :
FRONT ELEVATION
MULK 118/3131
PLOT NO:- BLOCK:- MUWAILEH COMMERCIAL
GOV. 6086
DESIGNED BY:- CORDINATED BY:- APPROVED BY:- DRAWING NO. :-
ENGR. MARIA INEC TEAM E.KHALID ALZ
FACADE BY:- SCALE:- 1/100 DATE:- JOB NO. :-
ENGR. ALBATOUL SHEET SIZE: A2 18-06-2023 INV 314
FOR MUNICIPALITY USE

14/11/2023

4
NOTE :
+24.45 m TOP OF PARAPET All Windows & Balcony Doors Should Be
Equipped with Windows Opening Control
Device (W.O.C.D) To Limits the Opening
2.50

2.50
2 2 2 Less Than 10cm to have Maximum Opening

2.70

2.70
Limit of 10cm to help in the Prevention of
Accidental Falls from Windows & Balcony
+21.95 m ROOF
by Children as per Sharjah Municipality

0.20
0.50
S.S.L
0.60 0.60 Regulation
2
2.20

2 2

2.00
1.70

1.70
4 S 4 S 4 S

3.40
1-TRAVERTINE
1.80

1.80
5 5

0.60
2 -STONE PAINT

1.20

1.20
1.70

1.70
+18.55m PENTHOUSE FLOOR
1 F.F.L 3 SIGNAGE WITH LED LIGHTS

1.10
0.50
4- REFLECTIVE POWDER COATED
2 4 2 4 2 2 2 4 ALUMINIUM FRAMED DOUBLE GLAZING
1.70

1.70
1.70

1.70
4 S 2 2

3.40
S Fix Fix S Fix S 5-PREFABRICATED ALUMINUM HANDRAIL WITH
4 4 4 WROUGHT IRON GRILLS
5

0.60
5 6- EMULSION PAINT RAL 780-1

1.20

1.20
1.70

1.70
1.20
+15.15m FOURTH FLOOR
1 F.F.L

1.10
0.50
SHARJAH MUNICIPALITY NOTES GENERAL NOTES SYMBOLS & ABBREVIATIONS
2 4 2 4 2 2 2 4
1.70

1.70
1.70

1.70
4 S 2 2 1. ALL DIMENSIONS IN CM.

3.40
S Fix Fix S Fix S * ALL WINDOWS & BALCONY DOORS SHOULD BE
EQUIPPED WITH WINDOWS OPENING CONTROL
2. DO NOT SCALE FROM DRAWING.
ELEVATION NUMBER

4 4 4 DEVICE (W.O.C.D) TO LIMITS THE OPENING LESS 3. ALL DIMENSIONS TO BE VERIFIED ON SITE

5 5
THAN 10CM CM TO HAVE MAXIMUM OPENING LIMIT
OF 10CM TO HELP IN THE PREVENTION OF
4. THIS DRAWING TO BE READ IN CONJUCTION

0.60
WITH RELEVANT ARCH,STRUC & MEP
24.30

24.30
SECTION NUMBER
ACCIDENTAL FALLS FROM WINDOWS AND BALCONY DETAILS & SPECIFICATIONS.

1.20

1.20
1.70

1.70
BY CHILDREN AS PER SHARJAH MUNICIPALITY

1.20
+11.75m THIRD FLOOR REGULATION.
5. CONTRACTOR MUST CO-ORDINATE

2 F.F.L
THESE DRAWINGS AND REPORT IF ANY LEVEL IN PLAN.

1.10
DISCREPANCY FOR CLARIFICATION BEFORE
0.50 *ALL EXTERNAL WALL ARE THERMAL INSULATION
PROCEEDING WITH THE WORK LEVEL IN ELEVATION & SECTION
BLOCKS WITH MINIMUM 20cm THICKNESS 6. ALL MATERIAL TO BE APPROVED IN WRITEN
BY ENGINEER. FINISHING NOTATION

2 4 2 4 2 2 2 *ALL WINDOWS ARE REFLECTIVE, DOUBLE GLAZING 7. CONTRACTOR SHOULD SUBMIT THE
1.70

1.70
SHOP DRAWING FOR APPROVAL. WINDOW NOTATION
4
1.70

1.70
4 S 2 2

3.40
S Fix Fix S Fix S 8. THE COPY RIGHTS OF THIS PLANS AND
DRAWINGS ARE RESERVED FOR INVESTMENT DOOR NOTATION
4 4 4 ENGINEERING CONSULTANCY. 2007
5

0.60
5
1.20

1.20
1.70

1.70
1.20
+8.35m SECOND FLOOR 1
1 F.F.L

1.10
0.50

2
2 2 2 2 3
4 4 4
1.70

1.70
2
1.70

1.70

1.70
4 S 2 2 4

3.40
S Fix Fix S Fix S
4 4 4 5
5
5

0.60 0.60
1.20

1.20
+4.95m FIRST FLOOR

1.20
F.F.L
2.80

2.80
2.20

2.20
1
1.60

1.60
Rev. No. REVISION Date Status

DESIGN CONSULTANT:

4.20
1.20 2.00
S
1.40

4 4 4

INVESTMENT
2.60
3.20

3.20
1 Fix Fix 1
3.20

1
1.20

1.20

1.20

+0.75 m GROUND FLOOR F.F.L


1.80

+0.15m INTERLOCK

0.60
0.90

0.90
1
0.60

0.60

LEVEL +0.15m INTERLOCK LEVEL


0.15

0.15
Engineering Consultancy
TEL : +971 6 5737979 FAX : +971 6 5737779
P.O.BOX : 1388, SHARJAH , UAE EMAIL : [email protected]
www.investmentengineering.ae

CLIENT'S :-

MR. ABDULAZIZ ABDULLA AHMED MOHAMAD


LEFT - SIDE ELEVATION AL ZAROONI
PROJECT TITLE :-

E2 PROPOSED G+4+PENTHOUSE (50%) BUILDING


DWG. TITLE :

LEFT - SIDE ELEVATION


MULK 118/3131
PLOT NO:- BLOCK:- MUWAILEH COMMERCIAL
GOV. 6086
DESIGNED BY:- CORDINATED BY:- APPROVED BY:- DRAWING NO. :-
ENGR. MARIA INEC TEAM E.KHALID ALZ
FACADE BY:- SCALE:- 1/100 DATE:- JOB NO. :-
ENGR. ALBATOUL SHEET SIZE: A2 18-06-2023 INV 314
FOR MUNICIPALITY USE

14/11/2023

4 NOTE :
All Windows & Balcony Doors Should Be
Equipped with Windows Opening Control
+24.45 m TOP OF PARAPET Device (W.O.C.D) To Limits the Opening
Less Than 10cm to have Maximum Opening
2 Limit of 10cm to help in the Prevention of
2.50

2.50
2.70

2.70
Accidental Falls from Windows & Balcony
by Children as per Sharjah Municipality
+21.95 m ROOF Regulation
S.S.L
0.60 0.60
2.20

0.60

2.00
4 4 4 4
2.00

2.00
2 2 2 2
1.70

1.70
0.90

4 1-TRAVERTINE

3.40
Fix Fix
S S S S
5 2 -STONE PAINT
5

0.60
1.80
3 SIGNAGE WITH LED LIGHTS
1.50
1.20

1.20

1.20
1.70

1.70
1.20

+18.55m PENTHOUSE FLOOR


F.F.L 4- REFLECTIVE POWDER COATED

1.10
1
0.50

0.50

0.50
ALUMINIUM FRAMED DOUBLE GLAZING
0.60 5-PREFABRICATED ALUMINUM HANDRAIL WITH
4 4 4 2
4
1.70

1.70
2 WROUGHT IRON GRILLS
1.70

1.70

1.70

1.70
2

0.90
4 4 2 4 4 4

3.40
Fix S Fix 2 2
S S S 6- EMULSION PAINT RAL 780-1
5

0.60
5

1.50
1.20

1.20

1.20
1.70

1.70
1.20

1 +15.15m FOURTH FLOOR


F.F.L

1.10
0.50

0.50
SHARJAH MUNICIPALITY NOTES GENERAL NOTES SYMBOLS & ABBREVIATIONS
1. ALL DIMENSIONS IN CM.
0.60 * ALL WINDOWS & BALCONY DOORS SHOULD BE

4 4 4 4 2 EQUIPPED WITH WINDOWS OPENING CONTROL


2. DO NOT SCALE FROM DRAWING.
ELEVATION NUMBER
1.70

1.70
2 DEVICE (W.O.C.D) TO LIMITS THE OPENING LESS 3. ALL DIMENSIONS TO BE VERIFIED ON SITE
1.70

1.70

1.70
2

0.90
4 4 4 4 4

3.40
2 Fix S Fix 2 2
THAN 10CM CM TO HAVE MAXIMUM OPENING LIMIT
OF 10CM TO HELP IN THE PREVENTION OF
4. THIS DRAWING TO BE READ IN CONJUCTION
WITH RELEVANT ARCH,STRUC & MEP
S S S ACCIDENTAL FALLS FROM WINDOWS AND BALCONY DETAILS & SPECIFICATIONS.
SECTION NUMBER

BY CHILDREN AS PER SHARJAH MUNICIPALITY


5 5 REGULATION.
5. CONTRACTOR MUST CO-ORDINATE

0.60
THESE DRAWINGS AND REPORT IF ANY LEVEL IN PLAN.
24.30

24.30
DISCREPANCY FOR CLARIFICATION BEFORE

1.50
1.20

1.20
1.70

1.70
1.20

1.20

1 +11.75m THIRD FLOOR *ALL EXTERNAL WALL ARE THERMAL INSULATION


BLOCKS WITH MINIMUM 20cm THICKNESS
PROCEEDING WITH THE WORK
6. ALL MATERIAL TO BE APPROVED IN WRITEN
LEVEL IN ELEVATION & SECTION

F.F.L

1.10
BY ENGINEER. FINISHING NOTATION
0.50

0.50

0.50
*ALL WINDOWS ARE REFLECTIVE, DOUBLE GLAZING 7. CONTRACTOR SHOULD SUBMIT THE
SHOP DRAWING FOR APPROVAL. WINDOW NOTATION
0.60
4 4 4
2 8. THE COPY RIGHTS OF THIS PLANS AND
DRAWINGS ARE RESERVED FOR INVESTMENT DOOR NOTATION
4
1.70

1.70
ENGINEERING CONSULTANCY. 2007
1.70

1.70

1.70
2

0.90
4 4 2 4 4 4

3.40
Fix S 2 Fix 2 2
S S S
5 5 1

0.60
1.50
1.20

1.20

1.20
1.70

1.70
1.20

1 +8.35m SECOND FLOOR 2


F.F.L

1.10
3
0.50

0.50

0.50
0.60 4
4 4 4 4
1.70

1.70
5
1.70

1.70

1.70
2

0.90
4 4 2 2 4 4 4

3.40
Fix S Fix 2 2
S S S
5 5

0.60
1.50
1.20

1.20

1.20
1.20

+4.95m FIRST FLOOR


1 F.F.L
2.80

2.80
2.20
Rev. No. REVISION Date Status
1.60

1.60

1.60
DESIGN CONSULTANT:
0.40

4.20
1.20
2.00
1 6
1 4 0.50 1
INVESTMENT
3.20

3.20
1.20
2.50

S
2.20

2.20

+0.75 m GROUND FLOOR F.F.L Engineering Consultancy


1.00

0.60
0.90

0.90
0.60

0.30

0.30

0.15 +0.15m INTERLOCK LEVEL


0.15
0.15

TEL : +971 6 5737979 FAX : +971 6 5737779


P.O.BOX : 1388, SHARJAH , UAE EMAIL : [email protected]
www.investmentengineering.ae

CLIENT'S :-

MR. ABDULAZIZ ABDULLA AHMED MOHAMAD


AL ZAROONI
RIGHT -SIDE ELEVATION PROJECT TITLE :-

E3 PROPOSED G+4+PENTHOUSE (50%) BUILDING


DWG. TITLE :

RIGHT - SIDE ELEVATION


MULK 118/3131
PLOT NO:- BLOCK:- MUWAILEH COMMERCIAL
GOV. 6086
DESIGNED BY:- CORDINATED BY:- APPROVED BY:- DRAWING NO. :-
ENGR. MARIA INEC TEAM E.KHALID ALZ
FACADE BY:- SCALE:- 1/100 DATE:- JOB NO. :-
ENGR. ALBATOUL SHEET SIZE: A2 18-06-2023 INV 314
FOR MUNICIPALITY USE

14/11/2023

4
NOTE :
All Windows & Balcony Doors Should Be
Equipped with Windows Opening Control
+24.45 m TOP OF PARAPET Device (W.O.C.D) To Limits the Opening
Less Than 10cm to have Maximum Opening
Limit of 10cm to help in the Prevention of

2.50
2.50

2.50
2.70
2 2 Accidental Falls from Windows & Balcony
by Children as per Sharjah Municipality
+21.95 m ROOF Regulation
S.S.L
0.60 0.60
2.20

2.80
2

1.70
2 1-TRAVERTINE

3.40
Fix S S Fix
4 4 2 -STONE PAINT
5

0.60
5 1.20 3 SIGNAGE WITH LED LIGHTS
1.70

1.20

+18.55m PENTHOUSE FLOOR

1.10
1 F.F.L 4- REFLECTIVE POWDER COATED

1.10
0.50

0.50

ALUMINIUM FRAMED DOUBLE GLAZING


5-PREFABRICATED ALUMINUM HANDRAIL WITH
4 4
1.70

2 WROUGHT IRON GRILLS


1.70

1.70

1.70
2 4 S 2 4 S 2 2 2 2

2.30
2

3.40
Fix S S Fix S Fix
4 4 4 6- EMULSION PAINT RAL 780-1
5

0.60
5
1.20

1.20
1.70

1.20
+15.15m FOURTH FLOOR

1.10
F.F.L

1.10
SYMBOLS & ABBREVIATIONS
0.50

0.50

SHARJAH MUNICIPALITY NOTES GENERAL NOTES


1. ALL DIMENSIONS IN CM.
* ALL WINDOWS & BALCONY DOORS SHOULD BE
2. DO NOT SCALE FROM DRAWING.
EQUIPPED WITH WINDOWS OPENING CONTROL ELEVATION NUMBER
4 4
1.70

DEVICE (W.O.C.D) TO LIMITS THE OPENING LESS 3. ALL DIMENSIONS TO BE VERIFIED ON SITE
1.70

1.70

1.70
4 S 4 S
2 2 2 2 2 S2 2

2.30
2 2 THAN 10CM CM TO HAVE MAXIMUM OPENING LIMIT

3.40
Fix S S Fix Fix OF 10CM TO HELP IN THE PREVENTION OF
4. THIS DRAWING TO BE READ IN CONJUCTION
WITH RELEVANT ARCH,STRUC & MEP SECTION NUMBER
ACCIDENTAL FALLS FROM WINDOWS AND BALCONY
4 4 4 BY CHILDREN AS PER SHARJAH MUNICIPALITY
DETAILS & SPECIFICATIONS.
5. CONTRACTOR MUST CO-ORDINATE
REGULATION.
THESE DRAWINGS AND REPORT IF ANY LEVEL IN PLAN.

0.60
5
24.30

24.30
5 DISCREPANCY FOR CLARIFICATION BEFORE
1.20

1.20
1.70

1.20
PROCEEDING WITH THE WORK
+11.75m THIRD FLOOR *ALL EXTERNAL WALL ARE THERMAL INSULATION LEVEL IN ELEVATION & SECTION

1.10
BLOCKS WITH MINIMUM 20cm THICKNESS 6. ALL MATERIAL TO BE APPROVED IN WRITEN
F.F.L

1.10
BY ENGINEER. FINISHING NOTATION
1
0.50

0.50

*ALL WINDOWS ARE REFLECTIVE, DOUBLE GLAZING 7. CONTRACTOR SHOULD SUBMIT THE
SHOP DRAWING FOR APPROVAL. WINDOW NOTATION
8. THE COPY RIGHTS OF THIS PLANS AND
DRAWINGS ARE RESERVED FOR INVESTMENT DOOR NOTATION
4 4
1.70

ENGINEERING CONSULTANCY. 2007


1.70

1.70

2 4 S 2 4 S 2 1.70 2 2 S2 2

2.30
2 2

3.40
Fix S S Fix Fix
4 4 4
1

0.60
5 5
1.20
1.70

2
1.20

1.20

1.20
+8.35m SECOND FLOOR

1.10
F.F.L

1.10
1 3
0.50

0.50

4
4 4
1.70

5
1.70

1.70

1.70

4 S 4 S
2 2 2 2 2 S2 2

2.30
2 2

3.40
Fix S S Fix Fix
4 4 4
5

0.60
5
1.20
1.20

1.20

+4.95m FIRST FLOOR

1.10
F.F.L
2.80

Rev. No. REVISION Date Status

2.20
1
1.60

1.90

DESIGN CONSULTANT:

4.20
1.20 4 1.37
INVESTMENT
1.40

1.40

1.40

4 S 4 4 4 4

4.30
S S S S
3.20

3.20
1.20

1.20

1.20

1.20
1.80

2 +0.75 m GROUND FLOOR F.F.L Engineering Consultancy

0.60
0.90

0.60

0.60

0.60

0.60

+0.15m INTERLOCK LEVEL


TEL : +971 6 5737979 FAX : +971 6 5737779
P.O.BOX : 1388, SHARJAH , UAE EMAIL : [email protected]
www.investmentengineering.ae

CLIENT'S :-

MR. ABDULAZIZ ABDULLA AHMED MOHAMAD


AL ZAROONI
REAR ELEVATION PROJECT TITLE :-

PROPOSED G+4+PENTHOUSE (50%) BUILDING

E4 DWG. TITLE :

REAR ELEVATION
MULK 118/3131
PLOT NO:- BLOCK:- MUWAILEH COMMERCIAL
GOV. 6086
DESIGNED BY:- CORDINATED BY:- APPROVED BY:- DRAWING NO. :-
ENGR. MARIA INEC TEAM E.KHALID ALZ
FACADE BY:- SCALE:- 1/100 DATE:- JOB NO. :-
ENGR. ALBATOUL SHEET SIZE: A2 18-06-2023 INV 314
Anti-root coating
FOR MUNICIPALITY USE
Drainage-water retention layer

Filter layer

ROOF GARDEN DETAIL SAND LAYER

CULTIVATION SOIL

Roof Finishes: Combo-roof system 14/11/2023

EXTERNAL PAINT (14)


EXTERNAL PLASTER FINISH (13)
FABRIC REINFORCEMENT (12)
POLYBOARD + BACKING ROD+ POLYSULPHIDE SEALANT (9) (10) (11)
POLYBOND BONDING AGENT (8)
POLYFLEX COMBO-TOP COAT(800 mic THICK) (7)
100x100mm ANGLE FILLET-OVER POLYBOND (BONDING AGENT) (6) RC SLAP
CONCRETE SCREED (26N/mm2-350 OPC, 80mm AVE. THICKNESS) (5)
POLYFAB FILTER MEMBRANE (1300 mic THICK) (4)
POLYTEX LIQUID U.V. PROTECTION COAT (600 mic THICK) (3)
POLYURETHANE FOAM OF THICKNESS 35-45 mm NOTE :
WITH 45-50 KG/M3 DENSITY (2)
CONCRETE SLAB (1) 5 All Windows & Balcony Doors Should Be
Equipped with Windows Opening Control
Device (W.O.C.D) To Limits the Opening
+24.45 m TOP OF PARAPET
Less Than 10 cm to have Maximum Opening

0.30
Limit of 10cm to help in the Prevention of
2.50

2.50

Accidental Falls from Windows & Balcony

2.70
2.20
by Children as per Sharjah Municipality

1.50
+21.95 m ROOF Regulation
S.S.L

0.70

0.70
5.40
20cm THERMAL INSULATION BLOCK 0.60

2.00
IN ALL OUTER WALL
1.70
3.40

STAIRCASE-01
3.20

3.20

3.20
2.50

2.50
Aluminum Handrail
0.60

0.60 0.60
1.20

1.20

1.20

1.20

1.20

1.20
+18.55m PENTHOUSE FLOOR

0.30

1.70
0.30
F.F.L SHARJAH MUNICIPALITY NOTES GENERAL NOTES SYMBOLS & ABBREVIATIONS
0.50

1. ALL DIMENSIONS IN CM.

0.60

0.60

0.60
* ALL WINDOWS & BALCONY DOORS SHOULD BE
2. DO NOT SCALE FROM DRAWING.

1.70
ELEVATION NUMBER
REFLECTIVE, DOUBLE GLAZING EQUIPPED WITH WINDOWS OPENING CONTROL
DEVICE (W.O.C.D) TO LIMITS THE OPENING LESS 3. ALL DIMENSIONS TO BE VERIFIED ON SITE
IN ALL WINDOWS 20cm THERMAL INSULATION BLOCK THAN 10CM CM TO HAVE MAXIMUM OPENING LIMIT
1.70

1.70
4. THIS DRAWING TO BE READ IN CONJUCTION
3.40

OF 10CM TO HELP IN THE PREVENTION OF


IN ALL OUTER WALL ACCIDENTAL FALLS FROM WINDOWS AND BALCONY
WITH RELEVANT ARCH,STRUC & MEP
DETAILS & SPECIFICATIONS.
SECTION NUMBER
3.10

3.10

3.10
2.90

BY CHILDREN AS PER SHARJAH MUNICIPALITY


5. CONTRACTOR MUST CO-ORDINATE
2.50

2.50

2.50
REGULATION.
THESE DRAWINGS AND REPORT IF ANY LEVEL IN PLAN.
0.60

0.60 0.60
DISCREPANCY FOR CLARIFICATION BEFORE

1.70
PROCEEDING WITH THE WORK
1.20

1.20

1.20

1.20
*ALL EXTERNAL WALL ARE THERMAL INSULATION LEVEL IN ELEVATION & SECTION

+15.15m FOURTH FLOOR

0.30

1.70
BLOCKS WITH MINIMUM 20cm THICKNESS 6. ALL MATERIAL TO BE APPROVED IN WRITEN
BY ENGINEER. FINISHING NOTATION

0.30
F.F.L
1.10

*ALL WINDOWS ARE REFLECTIVE, DOUBLE GLAZING 7. CONTRACTOR SHOULD SUBMIT THE

0.50
SHOP DRAWING FOR APPROVAL. WINDOW NOTATION
0.60

0.60

0.60
8. THE COPY RIGHTS OF THIS PLANS AND
REFLECTIVE, DOUBLE GLAZING

1.70
DRAWINGS ARE RESERVED FOR INVESTMENT DOOR NOTATION
ENGINEERING CONSULTANCY. 2007
IN ALL WINDOWS
1.70

1.70
3.40

3.10

3.10

3.10
2.90

2.50

2.50

2.50
Aluminum Handrail 1
0.60

0.60 0.60
24.30

24.30
1.70
2
1.20

1.20

1.20

1.20
0.30

1.70
0.30
3
1.10

0.50
4
0.60

0.60

0.60
1.70
REFLECTIVE, DOUBLE GLAZING
IN ALL WINDOWS 5
1.70

1.70
3.40

3.10

3.10

3.10
2.90

2.50

2.50

2.50
0.60

0.60 0.60
1.70
1.20

1.20

1.20
+8.35m SECOND FLOOR

0.30

1.70
0.30
F.F.L
1.10

0.50
Rev. No. REVISION Date Status
0.60

0.60

0.60
1.70

REFLECTIVE, DOUBLE GLAZING DESIGN CONSULTANT:


IN ALL WINDOWS
1.70

1.70
3.40

INVESTMENT
3.10

3.10

3.10
2.90

2.50

2.50

2.50
Aluminum Handrail
0.60

0.60 0.60
1.70

1.20
1.20

1.20

1.20

+4.95m FIRST FLOOR

0.30
0.30
F.F.L

2.80
2.20

Engineering Consultancy
0.90

1.60
1.50

20cm THERMAL INSULATION BLOCK


TEL : +971 6 5737979 FAX : +971 6 5737779
IN ALL OUTER WALL
P.O.BOX : 1388, SHARJAH , UAE EMAIL : [email protected]
4.20

3.90

3.90

1.20 www.investmentengineering.ae

4.20
0.90
3.00

CLIENT'S :-
Pump Room
3.20

3.20
2.90
MR. ABDULAZIZ ABDULLA AHMED MOHAMAD
1.50

1.50

100 GPM
AL ZAROONI
1.00

+0.75m GROUND FLOOR F.F.L


+0.45m LEVEL
0.60

PROJECT TITLE :-
+0.15m INTERLOCK LEVEL
PROPOSED G+4+PENTHOUSE (50%) BUILDING
COMPACTED EARTHFILL LIFT PIT COMPACTED EARTHFILL
FLOOR FINISHES DWG. TITLE :

7. CERAMIC TILES
SECTION A-A
6. CERAMIC SKERTING ALL AROUND
MULK 118/3131

SECTION A-A
5. MORTAR SCREED AND SAND FLOORING CONCRETE PLOT NO:- BLOCK:- MUWAILEH COMMERCIAL
4. 10 cm THICK B.R.C FLOORING WITH GOV. 6086
3. 8 mm MESH STEEL DESIGNED BY:- CORDINATED BY:- APPROVED BY:- DRAWING NO. :-
2. 1000 GUAGE POLYTHENE SHEET. ENGR. MARIA INEC TEAM E.KHALID ALZ
ANTI TERMITES TREATMENT
1. SUBKHA FILLING IN LAYERS. FACADE BY:- SCALE:- 1/100 DATE:- JOB NO. :-
ENGR. ALBATOUL SHEET SIZE: A2 18-06-2023 INV 314
FOR MUNICIPALITY USE
Roof Finishes: Combo-roof system PLANTER BOX DETAIL
EXTERNAL PAINT (14)
EXTERNAL PLASTER FINISH (13)
FABRIC REINFORCEMENT (12)
POLYBOARD + BACKING ROD+ POLYSULPHIDE SEALANT (9) (10) (11)
POLYBOND BONDING AGENT (8)
POLYFLEX COMBO-TOP COAT(800 mic THICK) (7)
100x100mm ANGLE FILLET-OVER POLYBOND (BONDING AGENT) (6)
14/11/2023
CONCRETE SCREED (26N/mm2-350 OPC, 80mm AVE. THICKNESS) (5)

0.70
POLYFAB FILTER MEMBRANE (1300 mic THICK) (4)
POLYTEX LIQUID U.V. PROTECTION COAT (600 mic THICK) (3)
POLYURETHANE FOAM OF THICKNESS 35-45 mm

0.20
WITH 45-50 KG/M3 DENSITY (2)
CONCRETE SLAB (1)

0.10

+24.45 m TOP OF PARAPET


NOTE :
All Windows & Balcony Doors Should Be
2.50

Equipped with Windows Opening Control

2.70
2.80

2.70
Device (W.O.C.D) To Limits the Opening
+21.95 m ROOF Less Than 10cm to have Maximum Opening
S.S.L Limit of 10cm to help in the Prevention of
20cm THERMAL INSULATION BLOCK 1.20
REFLECTIVE, DOUBLE GLAZING Accidental Falls from Windows & Balcony
2.00

2.00
0.60
IN ALL OUTER WALL IN ALL WINDOWS by Children as per Sharjah Municipality
3.40

Regulation

3.20
3.20
20cm THERMAL INSULATION BLOCK Aluminum Handrail

0.60
1.80

partition wall
IN ALL OUTER WALL

1.20

1.20
1.70

1.70
+18.60m PENTHOUSE CORRIDOR

0.60
1.20 CORRIDOR Toilet
F.F.L

0.50
REFLECTIVE, DOUBLE GLAZING

1.70
1.20
IN ALL WINDOWS
1.70

1.70
1.70

1.20
3.40

0.17
3.10

3.10
3.10

0.60 0.60
CORRIDOR SYMBOLS & ABBREVIATIONS
1.20

1.20

1.20
1.20 SHARJAH MUNICIPALITY NOTES GENERAL NOTES
1.70

1.70
+15.15m FOURTH FLOOR CORRIDOR Toilet 1. ALL DIMENSIONS IN CM.

0.17
F.F.L * ALL WINDOWS & BALCONY DOORS SHOULD BE
2. DO NOT SCALE FROM DRAWING.
ELEVATION NUMBER
EQUIPPED WITH WINDOWS OPENING CONTROL

0.50
DEVICE (W.O.C.D) TO LIMITS THE OPENING LESS 3. ALL DIMENSIONS TO BE VERIFIED ON SITE
THAN 10CM CM TO HAVE MAXIMUM OPENING LIMIT 4. THIS DRAWING TO BE READ IN CONJUCTION
1.20

1.70
OF 10CM TO HELP IN THE PREVENTION OF WITH RELEVANT ARCH,STRUC & MEP SECTION NUMBER
ACCIDENTAL FALLS FROM WINDOWS AND BALCONY

1.20
DETAILS & SPECIFICATIONS.
1.70

1.70
1.20 BY CHILDREN AS PER SHARJAH MUNICIPALITY
1.70

5. CONTRACTOR MUST CO-ORDINATE


3.40

1.20m HIGH REGULATION.

0.17
PREFABRICATED HANDRAIL THESE DRAWINGS AND REPORT IF ANY LEVEL IN PLAN.
DISCREPANCY FOR CLARIFICATION BEFORE
3.10

3.10

3.10
PROCEEDING WITH THE WORK LEVEL IN ELEVATION & SECTION
20cm THERMAL INSULATION BLOCK *ALL EXTERNAL WALL ARE THERMAL INSULATION
Aluminum Handrail BLOCKS WITH MINIMUM 20cm THICKNESS 6. ALL MATERIAL TO BE APPROVED IN WRITEN

0.60 0.60
IN ALL OUTER WALL
24.30

BY ENGINEER. FINISHING NOTATION


CORRIDOR
1.20

1.20

1.20
*ALL WINDOWS ARE REFLECTIVE, DOUBLE GLAZING 7. CONTRACTOR SHOULD SUBMIT THE
1.70

1.70
+11.75m THIRD FLOOR

24.30
1.20m HIGH
PREFABRICATED HANDRAIL CORRIDOR Toilet SHOP DRAWING FOR APPROVAL. WINDOW NOTATION

F.F.L 0.17 8. THE COPY RIGHTS OF THIS PLANS AND


DRAWINGS ARE RESERVED FOR INVESTMENT DOOR NOTATION

0.50
ENGINEERING CONSULTANCY. 2007

0.17
1.20
REFLECTIVE, DOUBLE GLAZING

1.20
1.20
1.70

1.70
1.70

IN ALL WINDOWS
1
3.40

0.17
3.10

3.10
3.10
2

0.60 0.60
1.20
CORRIDOR 3
1.20

1.20

1.20
1.70

1.70
+8.35m SECOND FLOOR CORRIDOR Toilet
4
0.17

F.F.L

0.50
1.20
5
1.70

1.20
1.70

1.70
1.70

REFLECTIVE, DOUBLE GLAZING 1.20


3.40

1.20m HIGH

0.17
IN ALL WINDOWS PREFABRICATED HANDRAIL
3.10

3.10

3.10

0.60 0.60
20cm THERMAL INSULATION BLOCK
1.70

CORRIDOR
1.20

1.20

1.20
+4.95m FIRST FLOOR IN ALL OUTER WALL 1.20 1.20m HIGH
CORRIDOR Rev. No. REVISION Date Status
Toilet
0.17

PREFABRICATED HANDRAIL

F.F.L
2.80

2.80

2.80
2.90

0.27 DESIGN CONSULTANT:

0.15
1.50

1.50

1.60
1.20
1.30

1.30
1.40

INVESTMENT
1.20 20cm THERMAL INSULATION BLOCK
IN ALL OUTER WALL
0.15
2.70

2.70
0.27 0.27
Signboard
4.20

0.75
0.15

0.15
4.20

1.20
3.90

1.50

1.50
1.40

2.00

4.35
2.50
2.40
3.20

3.20

3.20
Engineering Consultancy
2.70

0.27
0.27
SHOP-4

2.30
0.15
1.20

1.20

1.50
FHC
0.15

+0.75m GROUND FLOOR F.F.L 20cm THERMAL INSULATION BLOCK LOBBY


0.15

TEL : +971 6 5737979 FAX : +971 6 5737779


IN ALL OUTER WALL
0.60

0.90

0.90
0.30 +0.30 m F.F.L 1.20 1.35 0.30 P.O.BOX : 1388, SHARJAH , UAE EMAIL : [email protected]
+0.15m INTERLOCK LEVEL www.investmentengineering.ae
compacted earthfill ROAD
compacted earthfill 2.85 5.50m CLIENT'S :-
2.85m Interlock 5.50m Parking
MR. ABDULAZIZ ABDULLA AHMED MOHAMAD
FLOOR FINISHES AL ZAROONI
PROJECT TITLE :-
7. CERAMIC TILES
6. CERAMIC SKERTING ALL AROUND
5. MORTAR SCREED AND SAND FLOORING CONCRETE PROPOSED G+4+PENTHOUSE (50%) BUILDING
4. 10 cm THICK B.R.C FLOORING WITH
3. 8 mm MESH STEEL
DWG. TITLE :
2. 1000 GUAGE POLYTHENE SHEET.
ANTI TERMITES TREATMENT SECTION B-B
1. SUBKHA FILLING IN LAYERS.

SECTION B-B
MULK 118/3131
PLOT NO:- BLOCK:- MUWAILEH COMMERCIAL
GOV. 6086
DESIGNED BY:- CORDINATED BY:- APPROVED BY:- DRAWING NO. :-
ENGR. MARIA INEC TEAM E.KHALID ALZ
FACADE BY:- SCALE:- 1/100 DATE:- JOB NO. :-
ENGR. ALBATOUL SHEET SIZE: A2 18-06-2023 INV 314
FOR MUNICIPALITY USE

B 14/11/2023

B
0.20 2.70 0.20 +4.95 m F.F.L
+1.95m F.F.L +21.95 m ROOF
0.20 2.70 S.S.L

+18.55 m F.F.L
UP DN 108 DN NOTE :

3.40
All Windows & Balcony Doors Should Be

3.20

3.20

3.20

3.20

3.20
89 107

90 106 Equipped with Windows Opening Control

4.90
1.20m HIGH
Device (W.O.C.D) To Limits the Opening

1.20
+18.55m PENTHOUSE
91 105 PREFABRICATED HANDRAIL
1.20 1.20
1.20
92 104 F.F.L 108
107 109
110 Less Than 10cm to have Maximum Opening
93 103
106
105

104
1.20
106
107
108

Limit of 10cm to help in the Prevention of

1.70

1.70
Accidental Falls from Windows & Balcony
103 105
102 104
94 102 101 103

1.20
by Children as per Sharjah Municipality
100 102

1.20 1.20

3.40
99 101
95 101
1.20 1.20 98 100

3.10

3.10
3.10
99

Regulation
97
96 98

UP 96 100
94
95 97
96

1.70

1.70
93 95
94
97 99 92

1.20
1.20
98
+15.15m FOURTH FLOOR 90
91 93
92
91

0.17
89
F.F.L 88 90

+6.65 m F.F.L +16.85 m F.F.L


87

+0.75 m F.F.L
89
2.70 86 88
85 1.20 86
87

84

1.70

1.70
85

0.20 0.20 83
82 84

1.20
1.20m HIGH
PREFABRICATED HANDRAIL
81
1.20 83

13.04 m²
82
0.20
13.04 m²

3.40
13.04 m²
81

0.17
3.10

3.10

3.10
1.70

1.70
1.40

1.20
1.40
1.40 1.40 +11.75m THIRD FLOOR 1.20m HIGH
PREFABRICATED HANDRAIL
SHARJAH MUNICIPALITY NOTES GENERAL NOTES SYMBOLS & ABBREVIATIONS

0.17
F.F.L * ALL WINDOWS & BALCONY DOORS SHOULD BE
1. ALL DIMENSIONS IN CM.
2. DO NOT SCALE FROM DRAWING.
EQUIPPED WITH WINDOWS OPENING CONTROL ELEVATION NUMBER
1.20 DEVICE (W.O.C.D) TO LIMITS THE OPENING LESS 3. ALL DIMENSIONS TO BE VERIFIED ON SITE
THAN 10CM CM TO HAVE MAXIMUM OPENING LIMIT

1.70

1.70
4. THIS DRAWING TO BE READ IN CONJUCTION
DETAIL A OF 10CM TO HELP IN THE PREVENTION OF

1.20
WITH RELEVANT ARCH,STRUC & MEP SECTION NUMBER
1.20 ACCIDENTAL FALLS FROM WINDOWS AND BALCONY DETAILS & SPECIFICATIONS.
17.19

BY CHILDREN AS PER SHARJAH MUNICIPALITY

3.40
5. CONTRACTOR MUST CO-ORDINATE

0.17
2.44 m² REGULATION.
THESE DRAWINGS AND REPORT IF ANY LEVEL IN PLAN.

3.10

3.10

3.10
1.40
2.44 m² 1.40
*ALL EXTERNAL WALL ARE THERMAL INSULATION
DISCREPANCY FOR CLARIFICATION BEFORE
PROCEEDING WITH THE WORK LEVEL IN ELEVATION & SECTION

1.70

1.70
1.20 BLOCKS WITH MINIMUM 20cm THICKNESS 6. ALL MATERIAL TO BE APPROVED IN WRITEN
BY ENGINEER. FINISHING NOTATION

1.20
0.20
+8.35m SECOND FLOOR *ALL WINDOWS ARE REFLECTIVE, DOUBLE GLAZING 7. CONTRACTOR SHOULD SUBMIT THE
SHOP DRAWING FOR APPROVAL.

0.17
WINDOW NOTATION
0.20 2.70
0.20 2.70 0.20 F.F.L 8. THE COPY RIGHTS OF THIS PLANS AND
0.20 2.70 1.20 DRAWINGS ARE RESERVED FOR INVESTMENT DOOR NOTATION

+0.45m F.F.L ENGINEERING CONSULTANCY. 2007

1.70

1.70
1.20
+6.65 m F.F.L 1.20m HIGH

UP
PREFABRICATED HANDRAIL
1.20

3.40
+16.85 m F.F.L100

0.17
1

3.10

3.10

3.10
99
101
2
1.20

1.70
102 98
1.20 1.20 3

1.20
1.20m HIGH
+4.95m FIRST FLOOR 1.20 PREFABRICATED HANDRAIL

0.17
103 97
F.F.L 4

2.90

2.90
104 96
0.27

0.15
5

1.50

1.50
105 95
1.20m HIGH
0.27

106 94
DETAIL B PREFABRICATED HANDRAIL
20
19 1.20
1.20 1.20 18 20

2.70

2.70
0.27 16
17 19
18 0.27

4.20
107 93 17

0.15

0.15
15

1.20
14 16

3.90
1.50

1.50
13 15
0.20 108 92 11
12 14
13

2.70 9
10 12
11

2.40
10
109 91 8

2.70
DN
9
7
6 0.27 8 Rev. No. REVISION Date Status
7
5
0.27

0.15
13.04 m²

1.20
110 6

+18.55 m F.F.L
4

DN UP

1.50
5
FHC DESIGN CONSULTANT:
3

0.15
4

+0.75m GROUND FLOOR F.F.L


2
1 3
2

0.60
1

+0.15m INTERLOCK LEVEL


+1.95m F.F.L
2.70
13.04 m²
+4.95 m F.F.L 13.04 m² INVESTMENT
Engineering Consultancy
TEL : +971 6 5737979 FAX : +971 6 5737779
P.O.BOX : 1388, SHARJAH , UAE EMAIL : [email protected]
B

www.investmentengineering.ae

CLIENT'S :-

MR. ABDULAZIZ ABDULLA AHMED MOHAMAD


GROUND FLOOR PLAN FIRST FLOOR PLAN PENTHOUSE PLAN AL ZAROONI
PROJECT TITLE :-

PROPOSED G+4+PENTHOUSE (50%) BUILDING


DWG. TITLE :
STAIR CASE DETAIL
MULK 118/3131
PLOT NO:- BLOCK:- MUWAILEH COMMERCIAL
GOV. 6086
DESIGNED BY:- CORDINATED BY:- APPROVED BY:- DRAWING NO. :-
ENGR. MARIA INEC TEAM E.KHALID ALZ
FACADE BY:- SCALE:- 1/100 DATE:- JOB NO. :-
ENGR. ALBATOUL SHEET SIZE: A2 18-06-2023 INV 314
FOR MUNICIPALITY USE

89
F.F.L 88
87
86
14/11/2023

85
84
83
82
81
1.20
1.20m HIGH NOTE :
All Windows & Balcony Doors Should Be
PREFABRICATED HANDRAIL Equipped with Windows Opening Control
Device (W.O.C.D) To Limits the Opening
Less Than 10cm to have Maximum Opening
Limit of 10cm to help in the Prevention of
Accidental Falls from Windows & Balcony
by Children as per Sharjah Municipality
Regulation

SHARJAH MUNICIPALITY NOTES GENERAL NOTES SYMBOLS & ABBREVIATIONS

+11.75m THIRD FLOOR * ALL WINDOWS & BALCONY DOORS SHOULD BE


EQUIPPED WITH WINDOWS OPENING CONTROL
DEVICE (W.O.C.D) TO LIMITS THE OPENING LESS
THAN 10CM CM TO HAVE MAXIMUM OPENING LIMIT
1. ALL DIMENSIONS IN CM.
2. DO NOT SCALE FROM DRAWING.
3. ALL DIMENSIONS TO BE VERIFIED ON SITE
ELEVATION NUMBER

F.F.L
4. THIS DRAWING TO BE READ IN CONJUCTION
OF 10CM TO HELP IN THE PREVENTION OF WITH RELEVANT ARCH,STRUC & MEP SECTION NUMBER
ACCIDENTAL FALLS FROM WINDOWS AND BALCONY DETAILS & SPECIFICATIONS.
BY CHILDREN AS PER SHARJAH MUNICIPALITY 5. CONTRACTOR MUST CO-ORDINATE
REGULATION.
THESE DRAWINGS AND REPORT IF ANY LEVEL IN PLAN.
DISCREPANCY FOR CLARIFICATION BEFORE

DETAIL A
PROCEEDING WITH THE WORK LEVEL IN ELEVATION & SECTION
*ALL EXTERNAL WALL ARE THERMAL INSULATION
BLOCKS WITH MINIMUM 20cm THICKNESS 6. ALL MATERIAL TO BE APPROVED IN WRITEN
BY ENGINEER. FINISHING NOTATION
*ALL WINDOWS ARE REFLECTIVE, DOUBLE GLAZING 7. CONTRACTOR SHOULD SUBMIT THE
SHOP DRAWING FOR APPROVAL. WINDOW NOTATION
8. THE COPY RIGHTS OF THIS PLANS AND
DRAWINGS ARE RESERVED FOR INVESTMENT DOOR NOTATION
ENGINEERING CONSULTANCY. 2007

20
19 1.20 1
2
18 3

0.27 17 4
5
16

SCALE 1:20 12
13
14
15

Rev. No. REVISION

DESIGN CONSULTANT:
Date Status

11
Terrazo skirting tile 10 cm height ANTI SLIP ADHESIVE
10
INVESTMENT
(CARBORANDOM)
TREAD AS PER 9
3cm.THK.TERRAZZO
2cm.THK.MORTAR
SPECIFICATION
ANTI SLIP ADHESIVE
8 Engineering Consultancy
(CARBORANDOM)
ROUND EDGE
TEL : +971 6 5737979 FAX : +971 6 5737779
3cm.
TREAD 7 P.O.BOX : 1388, SHARJAH , UAE EMAIL : [email protected]
2cm.THK. (TERRAZO)
0.27 m 6 www.investmentengineering.ae
RISER

0.27
CLIENT'S :-
(TERRAZO) 5
SAND
4 MR. ABDULAZIZ ABDULLA AHMED MOHAMAD
AL ZAROONI
CEMENT MORTAR
3 PROJECT TITLE :-

+0.75m GROUND 2 PROPOSED G+4+PENTHOUSE (50%) BUILDING


1
CONCRETE STEP
SEE DETAIL FLOOR F.F.L DWG. TITLE :

STAIR CASE DETAIL


2mm Emulsion paint onSprayed plasters
MULK 118/3131
DETAIL OF TREAD & RISER DETAIL B PLOT NO:-

DESIGNED BY:-
GOV.

CORDINATED BY:-
6086
BLOCK:- MUWAILEH COMMERCIAL

APPROVED BY:- DRAWING NO. :-


ENGR. MARIA INEC TEAM E.KHALID ALZ
FACADE BY:- SCALE:- 1/100 DATE:- JOB NO. :-
ENGR. ALBATOUL SHEET SIZE: A2 18-06-2023 INV 314
FOR MUNICIPALITY USE

STEEL PLATE

NOTE :
All Windows & Balcony Doors Should Be
Equipped with Windows Opening Control
Device (W.O.C.D) To Limits the Opening
Less Than 10cm to have Maximum Opening
Limit of 10cm to help in the Prevention of
Accidental Falls from Windows & Balcony
by Children as per Sharjah Municipality
Regulation

Fix Fix

SHARJAH MUNICIPALITY NOTES GENERAL NOTES SYMBOLS & ABBREVIATIONS


1. ALL DIMENSIONS IN CM.
* ALL WINDOWS & BALCONY DOORS SHOULD BE
2. DO NOT SCALE FROM DRAWING.
EQUIPPED WITH WINDOWS OPENING CONTROL ELEVATION NUMBER
DEVICE (W.O.C.D) TO LIMITS THE OPENING LESS 3. ALL DIMENSIONS TO BE VERIFIED ON SITE
THAN 10CM CM TO HAVE MAXIMUM OPENING LIMIT 4. THIS DRAWING TO BE READ IN CONJUCTION
OF 10CM TO HELP IN THE PREVENTION OF WITH RELEVANT ARCH,STRUC & MEP SECTION NUMBER
ACCIDENTAL FALLS FROM WINDOWS AND BALCONY DETAILS & SPECIFICATIONS.
BY CHILDREN AS PER SHARJAH MUNICIPALITY 5. CONTRACTOR MUST CO-ORDINATE
REGULATION.
THESE DRAWINGS AND REPORT IF ANY LEVEL IN PLAN.
DISCREPANCY FOR CLARIFICATION BEFORE
PROCEEDING WITH THE WORK LEVEL IN ELEVATION & SECTION
*ALL EXTERNAL WALL ARE THERMAL INSULATION
BLOCKS WITH MINIMUM 20cm THICKNESS 6. ALL MATERIAL TO BE APPROVED IN WRITEN
BY ENGINEER. FINISHING NOTATION
*ALL WINDOWS ARE REFLECTIVE, DOUBLE GLAZING 7. CONTRACTOR SHOULD SUBMIT THE
SHOP DRAWING FOR APPROVAL. WINDOW NOTATION
8. THE COPY RIGHTS OF THIS PLANS AND
DRAWINGS ARE RESERVED FOR INVESTMENT DOOR NOTATION
ENGINEERING CONSULTANCY. 2007

1
2
Fix Fix S
3
4
S S S 5

Rev. No. REVISION Date Status

DESIGN CONSULTANT:

INVESTMENT
Engineering Consultancy
TEL : +971 6 5737979 FAX : +971 6 5737779
P.O.BOX : 1388, SHARJAH , UAE EMAIL : [email protected]

4 S no points for doors and


www.investmentengineering.ae

4 CLIENT'S :-

windows MR. ABDULAZIZ ABDULLA AHMED MOHAMAD


S AL ZAROONI
PROJECT TITLE :-

PROPOSED G+4+PENTHOUSE (50%) BUILDING


DWG. TITLE :

WINDOWS AND DOORS


MULK 118/3131
PLOT NO:- BLOCK:- MUWAILEH COMMERCIAL
GOV. 6086
DESIGNED BY:- CORDINATED BY:- APPROVED BY:- DRAWING NO. :-
ENGR. MARIA INEC TEAM E.KHALID ALZ
FACADE BY:- SCALE:- 1/100 DATE:- JOB NO. :-
ENGR. ALBATOUL SHEET SIZE: A2 18-06-2023 INV 314
FOR MUNICIPALITY USE

B
7.116 3.70 3.70 3.70 3.80 4.30
Plot Limit Plot Limit

3.14 2.60 0.20 1.05 2.60 0.85 1.20 1.00 0.68 2.60 1.15 2.60 0.67 1.00 1.20 0.80 2.60 1.20
3.50 3.00 0.20 1.05 5.65 7.70 5.69 2.32

0.10
Plant Box Plant Box

1.20
1.10

1.10

1.10
+4.95 m F.F.L Plant Box
6.71 m² 3.30 m² 1.04 m² 6.22 m² +4.95 m F.F.L 6.25 m²
+4.95 m F.F.L 8.49 m²

3.60 3.50

1.20
5.51 4.10 4.00

1.41
C'

0.60
2.50

4.70

4.70
0.10

1.20
1.20
21.24 m²

3.50

3.50

3.50

3.50

0.30
5.90

5.90
1.20

6.80
19.92 m² 14.35 m² 8.75 m² 20.65 m² 8.75 m²
14.00 m²

4.70

2.20
7.46
+4.95 m F.F.L +4.95 m F.F.L 2.50 1.20

1.55
5.05

1.90 0.50 1.20


3

0.60
Closet

0.60
1.20

1.20

1.20

1.20

1.20
0.60 4.32 m² 4.92 m² 4.14 m²
SECTION C'

1.80
3.73 3.60 4.10
1.00 2.30

2.50

2.30
SECTIONS IN
1.20

1.20 4.14 m² F-03 F-02

1.70
8.77 m² OTS

2.15
1.70 m²

1.30
5.10

0.20
Passage
FIRST FLOOR

1.20
1.80

1.30
3.42 1.56 m² +0.75 m
4.18 m²
2.04 m² 6.00 F-01
0.74 0.4

2.20

2.00
F.F.L
1.70 PLAN
0.10

1.70 +4.95 m F.F.L


2.89
5.50
1.20 1.41
2.00 1.70 +4.95 m F.F.L
1.10
2

0.70
1.30
0.90

1.40
7

4.10
2.30 m²

0.60
1.35
2.06 m² 1.19 m²

3.50
1.59 0.10

1.20
chute 25.13 m²

0.75

2.60
1.20
0.72 m²
3.50

1.69

1.50

1.50
3.53

21.99 m²
2.60

3.88 m² F-04 5.85 m² UP DN 5.80

5.55
6.11 m²

2.20
0.27
+4.95 m F.F.L 4.10 2.80

2.10
+4.95 m
F.F.L F-05
1.10 4.70 +4.95 m
F.F.L D'

0.20
2.50
6.73

3.10
4.83
1.50
0.20

8.26 m²

1.25
Passage
1.15

2.20

2.20

1.80
8.41

2.50
4.83 m² 1.20 1.20 1.56 m²
SECTION D'

1.60
2.20 2.10
+4.95 m F.F.L

3.50
+4.95 m
2.60 2.70 1.90 15.25 m²

1.20
F.F.L
A A

0.90
3.50

2.15
3.53

0.88
13.04 m² 4.50
2.60

1.65
24.451 m² +0.75 m
50.60 m²
F.F.L
Plant Box

2.00

2.00

0.80 0.20 0.80


3.88 m² 1.90
5.34 4.41 m² 1.40 1.40 2.00 4.00 m² 1.71 m²

16.20
SHARJAH MUNICIPALITY NOTES GENERAL NOTES SYMBOLS & ABBREVIATIONS

0.20
4.14 1.20

3.30
2.20

1.74
9.04 m²

3.20
3.40 1.90
+4.95 m 1. ALL DIMENSIONS IN CM.
8.00 m² 2.44 m² F.F.L * ALL WINDOWS & BALCONY DOORS SHOULD BE

38
1.40

19.00m TRAVEL DISTANCE BETWEEN 2nos. STAIRCASE


1.29

0.60 4.22 1.60 2. DO NOT SCALE FROM DRAWING.

.9 2
Plant Box

2.00
2.00 EQUIPPED WITH WINDOWS OPENING CONTROL ELEVATION NUMBER
1.20

2.30
1.20
2.50 2.64 m² 4.50 2.09 m² 3. ALL DIMENSIONS TO BE VERIFIED ON SITE
DEVICE (W.O.C.D) TO LIMITS THE OPENING LESS

0.68

1.30
0.50 1.92 m² 2.20 4.37 m²
2.70 THAN 10CM CM TO HAVE MAXIMUM OPENING LIMIT

1.20
4. THIS DRAWING TO BE READ IN CONJUCTION

3.90
17.55 m² OF 10CM TO HELP IN THE PREVENTION OF WITH RELEVANT ARCH,STRUC & MEP SECTION NUMBER
1.00

16.20 m² 4.15
0.90

ACCIDENTAL FALLS FROM WINDOWS AND BALCONY DETAILS & SPECIFICATIONS.


2.25 m²
4.10

4.10

Plant Box 2.10 1.20 BY CHILDREN AS PER SHARJAH MUNICIPALITY


4.24

2.60

+4.95 m
2.12 m² 1.20 1.20 5. CONTRACTOR MUST CO-ORDINATE

2.00

1.80
F.F.L REGULATION.

1.50
2.25 9.11 m² Passage THESE DRAWINGS AND REPORT IF ANY LEVEL IN PLAN.

0.60
2.70

3.05
1.75 m² DISCREPANCY FOR CLARIFICATION BEFORE

4.83
0.10
5.23 m²

1.20
2.50
4.15
D
1.80

4.05 m² 8.16 m² PROCEEDING WITH THE WORK LEVEL IN ELEVATION & SECTION

0.20
3.68 *ALL EXTERNAL WALL ARE THERMAL INSULATION

1.10
1.15

4.75
BLOCKS WITH MINIMUM 20cm THICKNESS 6. ALL MATERIAL TO BE APPROVED IN WRITEN
2.70 2.80 1.10 4.70
1.08

BY ENGINEER. FINISHING NOTATION


0.20

DN UP
5.80 *ALL WINDOWS ARE REFLECTIVE, DOUBLE GLAZING 7. CONTRACTOR SHOULD SUBMIT THE
1.20
4.55 1.00 SHOP DRAWING FOR APPROVAL.

2.60
1.20
WINDOW NOTATION

1.00
0.90
2.70
1.05

13.04 m² FHC 1.70 m²

3.50
7.50 m² 1.70 8. THE COPY RIGHTS OF THIS PLANS AND
SECTIONS IN
2.00

+4.95 m
+4.95 m 20.86 m²
F.F.L 4.20 m² F.F.L DRAWINGS ARE RESERVED FOR INVESTMENT DOOR NOTATION
2.10 2.80 +4.95 m F.F.L 1.10 SECTION D SECONDE TO 4TH ENGINEERING CONSULTANCY. 2007
3.50

+4.95 m F.F.L
3.53

1.40
F-09 FLOOR PLAN

1.05 0.20 0.90

0.20 0.85
3.88 m² 15.13 m²

2.00
Plant Box
5.90
2.50

2 0.83 m²
1.30

1.30

6.63 m² F-06 7.20


4.09 5.10
F-07 F-08 OTS
1

0.60
1.50 m²
0.10

0.90 1.50

1.50
0.10

1.80
1.20 1.10 2.50

1.00
1.00 1.75 m²
1.00
1.00
2

0.60
4.08 1.30
1.20

0.30
1.60

1.80 1.30

1.10
1.50

+4.95 m +4.95 m 4.50 m²


1.60 m²

3.10
F.F.L

1.20
Passage
2.20

F.F.L 2.60
2.00

1.92 m² OTS 7.75 m²

3
2.53

1.76 m² 1.50 m² 4.00 m² 1.60 1.50


1.10

2.00 Passage 1.20


+4.95 m F.F.L

1.20
2.97 m²
1.92 m²

1.35
2.00 1.40
4
1.20

1.20

Plant Box Passage Passage


6.10
6.00

22.11 m² 4.10
8.29 m² 2.40 m²
SECTION C
5
1.20

1.68 m²

8.00
5.00

1.20
17.50 m²
4.80

4.80
18.47 m²
7.26

4.30

3.90

3.54 15.05 m² 3.50 3.50 3.60

3.60

3.50
+4.95 m F.F.L +4.95 m F.F.L 14.35 m²
2.50
2.60

8.75 m²

2.10
Plot Limit Plot Limit
3.29 3.50

Plant Box
1.00

1.00

1.00

1.10
3.00 m²
+4.95 m +4.95 m Plant Box 3.50 m²
+4.95 m +4.95 m
6.55 m² 10.14 m²
F.F.L 3.50 m² F.F.L F.F.L
F.F.L 3.70 m²
Rev. No. REVISION Date Status
0.10

1.53 3.00 3.50


2 3.90 3.50 0.20 6.55 2.75
DESIGN CONSULTANT:
0.87 2.60 0.20 0.90 2.60 1.35 1.20 1.80 2.60 0.45 0.45 2.60 0.75 2.60 1.70 1.20

A B' A' B A
INVESTMENT
B

TYPICAL 1ST- 4TH FLOOR PLAN 3.597 3.70 3.70 3.70 3.80 4.30

Engineering Consultancy
0.60

1.20

1.00 0.10
TEL : +971 6 5737979 FAX : +971 6 5737779
0.60

0.10
1.20

0.10
1.00 0.10
1.20
0.60

P.O.BOX : 1388, SHARJAH , UAE EMAIL : [email protected]


0.30

1.10

0.30

1.10

www.investmentengineering.ae
2.20

2.20
1.60

2.00
1.60

20cm THERMAL INSULATION BLOCK


2.00
IN ALL OUTER WALL 20cm THERMAL INSULATION BLOCK CLIENT'S :-
IN ALL OUTER WALL

2.00

SECTION A
2.00
SECTION B MR. ABDULAZIZ ABDULLA AHMED MOHAMAD
SECTIONS IN
SECTION-B' SECTION-A' SECTIONS IN
AL ZAROONI
SECONDE TO 4TH SECONDE TO 4TH PROJECT TITLE :-
FLOOR PLAN FLOOR PLAN
SECTIONS IN FIRST PROPOSED G+4+PENTHOUSE (50%) BUILDING
FLOOR PLAN SECTIONS IN BALCONY
DWG. TITLE :

MULK 118/3131
PLOT NO:- BLOCK:- MUWAILEH COMMERCIAL
GOV. 6086
DESIGNED BY:- CORDINATED BY:- APPROVED BY:- DRAWING NO. :-
ENGR. MARIA INEC TEAM E.KHALID ALZ
FACADE BY:- SCALE:- 1/100 DATE:- JOB NO. :-
ENGR. ALBATOUL SHEET SIZE: A2 18-06-2023 INV 314
FOR MUNICIPALITY USE

0.60
+24.45 m 0.20
TOP OF PARAPET

2.50

2.70
0.60

chute +21.95 m ROOF


cover S.S.L

0.60

5.00
SECTION-1
GRP PANEL O.H.W.T
5,000 UK GALLONS CAPACITY 3
4.00

2.00
Rest on 50cm Concrete base
+24.15 m
TO BE COVERED BY ALUMINUM MESH S.S.L OTS
TANK SIZE= 5.00x4.00x1.50m HEIGHT

3.30
1.74
LIQUID HEIGHT= 1.20m 3.40

1 1 2.00

0.20
3.90
1 1
+24.45 m
TOP OF PARAPET

3 3

2.50

2.70
OTS
3.90

2 +21.95 m ROOF
S.S.L
SHARJAH MUNICIPALITY NOTES

* ALL WINDOWS & BALCONY DOORS SHOULD BE


GENERAL NOTES
1. ALL DIMENSIONS IN CM.
SYMBOLS & ABBREVIATIONS

2. DO NOT SCALE FROM DRAWING.


EQUIPPED WITH WINDOWS OPENING CONTROL ELEVATION NUMBER
DEVICE (W.O.C.D) TO LIMITS THE OPENING LESS 3. ALL DIMENSIONS TO BE VERIFIED ON SITE
0.60 THAN 10CM CM TO HAVE MAXIMUM OPENING LIMIT 4. THIS DRAWING TO BE READ IN CONJUCTION
+21.95 m ROOF OF 10CM TO HELP IN THE PREVENTION OF
ACCIDENTAL FALLS FROM WINDOWS AND BALCONY
WITH RELEVANT ARCH,STRUC & MEP SECTION NUMBER
DETAILS & SPECIFICATIONS.
S.S.L BY CHILDREN AS PER SHARJAH MUNICIPALITY
REGULATION.
5. CONTRACTOR MUST CO-ORDINATE
THESE DRAWINGS AND REPORT IF ANY LEVEL IN PLAN.
DISCREPANCY FOR CLARIFICATION BEFORE
PROCEEDING WITH THE WORK
SECTION-2 *ALL EXTERNAL WALL ARE THERMAL INSULATION
BLOCKS WITH MINIMUM 20cm THICKNESS 6. ALL MATERIAL TO BE APPROVED IN WRITEN
LEVEL IN ELEVATION & SECTION

2 1.00 3 *ALL WINDOWS ARE REFLECTIVE, DOUBLE GLAZING


BY ENGINEER.
7. CONTRACTOR SHOULD SUBMIT THE
SHOP DRAWING FOR APPROVAL.
FINISHING NOTATION

WINDOW NOTATION
OTS

1.50
8. THE COPY RIGHTS OF THIS PLANS AND
DRAWINGS ARE RESERVED FOR INVESTMENT DOOR NOTATION
ENGINEERING CONSULTANCY. 2007

+23.45 m

1 TOP OF OTS PARAPET

1.50
0.20
0.60

+21.95 m ROOF

0.20
S.S.L

Rev. No. REVISION Date Status

DESIGN CONSULTANT:

1 SECTION-3
INVESTMENT
Engineering Consultancy
TEL : +971 6 5737979 FAX : +971 6 5737779
P.O.BOX : 1388, SHARJAH , UAE EMAIL : [email protected]
www.investmentengineering.ae

CLIENT'S :-

MR. ABDULAZIZ ABDULLA AHMED MOHAMAD


AL ZAROONI
PROJECT TITLE :-

PROPOSED G+4+PENTHOUSE (50%) BUILDING


@ ROOF SLAB LEVEL DWG. TITLE :
ROOF SECTIONS

MULK 118/3131
PLOT NO:- BLOCK:- MUWAILEH COMMERCIAL
GOV. 6086
DESIGNED BY:- CORDINATED BY:- APPROVED BY:- DRAWING NO. :-
ENGR. MARIA INEC TEAM E.KHALID ALZ
FACADE BY:- SCALE:- 1/100 DATE:- JOB NO. :-
ENGR. ALBATOUL SHEET SIZE: A2 18-06-2023 INV 314
Plot Limit Plot Limit

+0.15 m Interlock Level +0.15 m Interlock Level

1.80
1.20m PROJECTION LINE
2.50 2.60 1.25 2.60 0.85 1.20 1.68 2.60 1.15 2.60 1.67 1.20 0.80 2.60 1.20

1.00

1.00

1.00

1.00
Plant Box Plant Box Plant Box Plant Box Plant Box
3.00
3.00 3.00 3.00

4.90 4.00
1.41

3.70 3.50 2.50


Plant Box

3.80
3.50

3.50

3.50

3.50

3.50

3.90
3.60
3.00
1.20

19.92 m² 14.35 m² 8.75 m² 21.24 m² 20.65 m² 8.75 m² 14.00 m²


el
Interlock Lev

5.50
1.00
+0.75 m F.F.L
4.44 4.10 2.50
+0.75 m F.F.L

7.00
3
1.90

0.60
Closet 3.60
+0.15 m

1.20 2.20

0.80
1.20

1.20

1.20
Cabinet

1.10
2.52 m² 2.42 m²
3.13

1.90
1.00 2.20 5.10 4.32 m² Common Toilet
2.50

2.50

2.30

2.00 Level
1.20

1.20
4.14 m²

1.70
7.50 m² OTS 3.50
2.90

+0.15 m Interlock
Passage 1.80 1.70 m² F-02 1.85 1.55
+0.75 m

1.90
1.56 m²

2.20
F.F.L 4.00m²

2.00
3.80 +0.75 m F.F.L Watchman's Room

0.80
2.50
2.40

2.40
3.18 m²
1.21

1.30
1.00 7.25 m²
5.99 0.70 2.10 F-01 +0.30m F.F.L
4.28 m²

0.20 0.90
1.45

3.10

3.10
3.50
11.78 m²

0.40
2.70

1.20
Plant Box +0.75 m F.F.L

1.80
1.75m Corridor
3.50

F-03 +0.45m F.F.L

1.20m PROJECTION LINE


20.15 m²
2.60

7.30 RAMP UP

1.50

1.50

1.50
chute Garbage Trolley Passage
+0.75 m F.F.L 5.30 2.00 2.80 3.60
TION LINE

1.00 6.40
5.53 2.70 1.20 1.20 2.30

3.87
2.20
6.00

1.60

4.83
4.50
Garbage Room
EC

1.90
2.20
3.50

1.87
4.83 m² +0.45m F.F.L
1.20m PROJ

1.01 Pump Room 2.70 UP


1.20

1.20

7.75m ramp Lenght 2.00


100 GPM FIRE FIGHTING PUMP SET 3.90
slope 1:12
R.C.C U/G.W.T WITH TOTAL
4.50

+0.75 m F.F.L +0.45m LEVEL

1.20
1.21 0.94 1.20 CAPACITY OF 11,500 UK GALS 1.70 2.00

4.50
2.20
3.50
4.39

1.00 U/G.W.T AREA=43.68 m²


1.10

3.70

1.00
9.50

1.10
Plant Box LIQUID DEPTH = 1.20m 9.20 m² 13.04 m² OTS +0.75 m F.F.L
Transformer Room
3.10

+0.75 m F.F.L
Gas Mt. Rm

2.50
TOTAL DEPTH = 1.50m
2.50

2.00
2.50

0.54
5.00 4.41 m²
6.90
1.20

1.00
Ramp up +0.75 m F.F.L

1.74

1.50
8.70

1.20
0.60
+0.75 m F.F.L

0.30
2.53

1.50
2.70 2.25 4.50
+0.45m F.F.L
el

Main Lobby
Interlock Lev

Main Entrance UP

3.65
Electrical Room

3.00
33.44 m²
15.28 m² 1.50 2.25
4.10

4.10

+0.75 m F.F.L +0.75 m F.F.L


step up
4.14

1.20

1.80
+0.75m F.F.L

+0.15 m Interlock Level


Telephone Room
+0.15 m

4.48
Exit
4.83

+0.75 m F.F.L
+0.45m F.F.L
12.18
3.48 8.50 1.20
0.27

RAMP UP

1.50

1.50
1.50 1.50 1.90 1.50 1.90 1.50
2.95 8.90
1.20

13.04 m²
1.40

1.40

1.40
1.50

1.50

1.50

2.70
Plant Box
Toilet Toilet Toilet

0.80
3.60 BC
3.00

1.60 1.60 1.60

1.95
SHARJAH MUNICIPALITY NOTES GENERAL NOTES SYMBOLS & ABBREVIATIONS

0.85
1.00 Gas duct

1. ALL DIMENSIONS IN CM.


4.10 3.50 3.50 3.50 3.60 4.10 * ALL WINDOWS & BALCONY DOORS SHOULD BE
2. DO NOT SCALE FROM DRAWING.
EQUIPPED WITH WINDOWS OPENING CONTROL ELEVATION NUMBER
DEVICE (W.O.C.D) TO LIMITS THE OPENING LESS 3. ALL DIMENSIONS TO BE VERIFIED ON SITE
8.70

8.70

8.70
9.18

THAN 10CM CM TO HAVE MAXIMUM OPENING LIMIT


7.75

7.75

7.75

8.15
4. THIS DRAWING TO BE READ IN CONJUCTION
7.40
7.20

7.20

7.20

OF 10CM TO HELP IN THE PREVENTION OF WITH RELEVANT ARCH,STRUC & MEP SECTION NUMBER
ACCIDENTAL FALLS FROM WINDOWS AND BALCONY

5.80
DETAILS & SPECIFICATIONS.
BY CHILDREN AS PER SHARJAH MUNICIPALITY 5. CONTRACTOR MUST CO-ORDINATE
REGULATION.
THESE DRAWINGS AND REPORT IF ANY LEVEL IN PLAN.
Plant Box
0.20 0.30 0.30 0.30 0.40 0.40 DISCREPANCY FOR CLARIFICATION BEFORE
+0.30 m F.F.L +0.30 m F.F.L +0.30 m F.F.L +0.30 m F.F.L +0.30 m F.F.L +0.30 m F.F.L
PROCEEDING WITH THE WORK LEVEL IN ELEVATION & SECTION
4.08

1.80 1.20 1.80 1.20 1.80 1.20 1.80 1.20 1.80 1.20 1.80 1.20 *ALL EXTERNAL WALL ARE THERMAL INSULATION
1.00
Plot Limit BLOCKS WITH MINIMUM 20cm THICKNESS 6. ALL MATERIAL TO BE APPROVED IN WRITEN
Plot Limit BY ENGINEER. FINISHING NOTATION
1.20

1.20

1.20

1.20

+0.15 m Interlock +0.15 m Interlock


Level Plant Box Plant Box Plant Box Plant Box Plant Box Level Plant Box
*ALL WINDOWS ARE REFLECTIVE, DOUBLE GLAZING 7. CONTRACTOR SHOULD SUBMIT THE
0.38 3.00 0.70 3.00 0.70 3.00 0.70 3.00 0.80 3.00 0.80 3.00 0.90 SHOP DRAWING FOR APPROVAL. WINDOW NOTATION
2.00m PROJECTION LINE
1.35

1.35

+0.15 m Interlock +0.15 m Interlock


8. THE COPY RIGHTS OF THIS PLANS AND
1.65

Level Level
DRAWINGS ARE RESERVED FOR INVESTMENT DOOR NOTATION
0.30

0.30

grass area grass area grass area grass area grass area grass area
2.40 ENGINEERING CONSULTANCY. 2007

GROUND FLOOR PLAN


1
2
3
4
5

Plot Limit Plot Limit

3.14 2.60 0.20 1.05 2.60 0.85 1.20 1.00 0.68 2.60 1.15 2.60 0.67 1.00 1.20 0.80 2.60 1.20
3.50 3.00 1.05 5.65
2 7.70 5.68 2.32

Rev. No. REVISION Date Status


Plant Box Plant Box Plot Limit Plot Limit
1.20
1.10

1.10

1.10

+4.95 m F.F.L Plant Box


6.71 m² 3.30 m² 1.04 m² 6.22 m² +4.95 m F.F.L 6.25 m²
8.49 m²

DESIGN CONSULTANT:
+4.95 m F.F.L

3.60 3.50
1.20

5.51 4.10 4.00

2.50
4.70

4.70

1.20

1.20

1.20
21.24 m² 11.90
3.50

3.50

3.50

3.50
5.90

5.90

6.80

19.92 m² 14.35 m² 8.75 m² 20.65 m² 8.75 m²


14.00 m²
4.70

GARDEN

3.20
+4.95 m F.F.L +4.95 m F.F.L 2.50 45.96 m²
1.55

5.05

4.40
0.50 1.20
3 GARDEN
3
0.60

Closet 58.43 m²

INVESTMENT
0.60
1.20

ROOF ACCESS AREA


1.20

1.20

1.20

1.20

0.60 4.32 m² 4.92 m² 4.14 m²


1.80

3.73 3.60 4.10


31.11 m² 3.70 8.00
1.00 2.30
2.50

2.30

1.20 4.14 m² F-03 F-02 7.72 3.50 F-03


+18.55 m F.F.L
1.70

8.77 m² OTS
2.15

1.70 m²
1.30

5.10
0.20

Passage Balcony
1.20

1.80 +18.55 m F.F.L

3.00
1.30

3.42 1.56 m² +0.75 m


4.18 m²
2.04 m² 6.00 F-01
5.10
2.20

2.00

F.F.L
1.70 +4.95 m F.F.L Balcony Outdoor sitting area
1.70 Service Cat
2.89
5.50
1.20 1.41
2.00 1.70 +4.95 m F.F.L
1.10
2 Outdoor sitting area
1.40 2.10
Ladder to Roof
24.00m²
0.70
1.30

0.90
1.40

3.00

3.00
22.08 m² 1.00 3.00 1.00 6.20 2.60 3.20
4.10

2.30 m²
1.35

2.06 m² 1.19 m² Exit


3.50

1.59 25.13 m² OTS


chute F-02

1.70
0.75

0.93
+18.55 m F.F.L 1.70 m² 1.70 +18.55 m F.F.L
1.20

2.60

1.69 0.72 m² 7.60


3.50

+0.75 m
6.00

1.20
1.50

1.50

21.99 m² 1.72 2.60 5.40

1.30
3.88 m² F-04 5.85 m² UP DN 5.80 F-03
5.55

6.11 m²

2.00
1.20
0.27

Engineering Consultancy
+4.95 m F.F.L 4.10 2.80
2.10

+4.95 m 1.10 4.70 1.90


F.F.L F-05 +4.95 m
8.89

1.00
F.F.L 1.00 1.20 1.80
0.20

0.70
2.50

2.60
6.73

4.10
Toilet
3.10

1.35
4.83

1.50 23.37 m²
8.26 m² 0.90 2.43 m²
1.25

Passage

0.75
2.40 chute +18.55 m F.F.L
2.20

2.20

1.80

1.20
8.41
2.50

4.83 m² 1.20 1.20 1.56 m² 2.70 0.72 m²

3.50

1.50
30.30 m² F-02 +18.55 m F.F.L
1.60

4.40
+4.95 m F.F.L
2.20 2.10 +18.55 m F.F.L DN 5.70
TEL : +971 6 5737979 FAX : +971 6 5737779
3.50

+4.95 m 8.43 1.50m Corridor


2.60 2.70 1.90 15.25 m² 1.10 4.60
1.20

F.F.L
0.90

1.67
3.50

2.45
2.20
2.15

4.63 1.20 2.60


EMAIL : [email protected]
0.88

13.04 m² 4.50
P.O.BOX : 1388, SHARJAH , UAE
2.60

+0.75 m
1.65

24.451 m²

3.10
4.83
50.60 m² 8.54 m²
F.F.L

1.20
Plant Box Passage
2.00

2.00

0.80 0.20 0.80


1.90

3.88 m² 2.00

2.20
5.34 4.41 m² 1.40 1.40 2.00 4.00 m² 4.00 0.50
0.50 2.90
1.71 m² 4.83 m² 1.20 1.20 2.20
16.20

1.10
1.20
0.20

4.14 1.20
www.investmentengineering.ae
3.30

2.20
1.74

9.04 m² Closet 2.20 m² 2.10

1.50
4.50
3.20

16.00m TRAVEL DISTANCE BETWEEN 2nos. STAIRCASE


3.40 1.90 14.00 m²
+4.95 m
Closet
1.80 1.10
8.00 m² 2.44 m² F.F.L

4.00

2.60
1.40
19.00m TRAVEL DISTANCE BETWEEN 2nos. STAIRCASE
1.29

1.20
0.60 4.22 1.60 Plant Box 3.50
2.00

3.50
2.00
1.20

2.20
2.20
2.30

Passage
1.20

2.50 2.64 m² 4.50

0.88
2.09 m²

14.00
13.04 m²
0.68

1.30

0.50 1.92 m² 2.20 4.37 m² 2.00


2.70

5.00
1.20

2.00
1.40 1.00
3.90

9.50 m²

1.90
17.55 m² 14.15 m² 4.41 m² 1.40 OTS
9.04 m² 4.00 m²
1.00

3.80
16.20 m² 4.15
0.90

3.30

0.35 0.90
Passage

1.74
+4.95 m F.F.L

1.74
2.25 m² 4.04
4.10

4.10

Plant Box 2.10 1.20 Closet


2.60

+4.95 m
2.12 m² 1.20 1.20 2.50
2.00

1.80

F.F.L 3.40
1.50

2.25 9.11 m² Passage 2.44 m² 1.40


5.00 1.50 1.20
2.70

2.72
3.05

0.60
1.75 m² 1.20
Closet
4.83

5.23 m²

1.20
2.50

4.15 2.64 m² 2.00


1.80

0.68
4.05 m² 8.16 m² 2.70
0.20

3.68 2.20 17.50 m²

1.20
1.15 3.85
Balcony
4.75

2.80 1.10 4.70 2.00

3.50

3.50

2.60
2.70
1.08

3.40
2.10 9.18 m²
3.90
DN UP
5.80
F-03

1.90

2.05
4.55 1.00 5.00
2.60
1.20

4.10 m²
1.00

19.44 m² 4.00 m²
0.90
2.70

FHC 1.70 m²

5.30
13.04 m² 0.80 +4.95 m F.F.L +18.55 m F.F.L
3.50

7.50 m² 1.70

0.90
2.00

+4.95 m

4.70

4.83
+4.95 m 20.86 m²
4.20 m² F.F.L
F.F.L

3.90

3.90

1.00
1.10 1.20 1.20
2.10 2.80 +4.95 m F.F.L +18.55 m F.F.L
3.50

+4.95 m F.F.L 2.10 15.21 m²


3.51 Closet
1.40

0.60
F-09
1.05 0.20 0.90

0.20 0.85

3.88 m² 15.13 m²
2.00

Plant Box DN

1.90
5.90
2.50

0.60 1.50

1.90
4.00 m² +18.55 m F.F.L
2 0.83 m²
1.30

1.30

F-06 7.20 Balcony

1.20
6.63 m²

1.30
0.85
Closet

2.95
0.80
4.09 5.10 9.30 m²

2.60
F-07 OTS 2.10

3.50
F-08 13.04 m²

3.60

3.60
0.10
1.50 m² F-01
0.90 1.50
1.50

F-01
1.80

1.20 1.10 2.50


1.00

1.00 1.75 m²
1.00

1.00

0.70
0.90 2.60 2.40 2.40

0.60
4.08 1.30
1.20

+18.55 m F.F.L
1.60

1.80 1.30 1.00


1.50

+4.95 m +4.95 m 4.50 m²


1.60 m² 2.60
3.10

1.70
0.30
F.F.L F-02 18.00 m²
1.20

Passage
2.20

F.F.L 2.60
2.00

1.92 m² OTS 7.75 m² 5.00

2.40

0.55
+18.55 m F.F.L Gas Riser
2.53

1.76 m² 4.00 m² 1.60 1.50 0.80

3.00
1
1.50 m²
1.10

11.50 m²
Balcony

1.70

1.70
+4.95 m F.F.L 2.00 Passage
1.20

1.77
2.97 m²
1.92 m² Outdoor sitting area 5.00 1.00
1.35

31.06 m²

4.60
2.00 1.40 OTS

1.50

1.80

1.80

1.80
1.50 m²
1.20

1.20

Plant Box Passage Passage 5.31 Toilet 1.20 4.32 m²


6.10
6.00

4.10 1.30 4.68 m²

0.60
22.11 m²
8.29 m² 2.40 m² 2.40

1.50

1.10
OTS 2.42 m²
1.20

1.68 m²
8.00

+18.55 m F.F.L 2.60


5.30 1.50 m²
5.00

1.20

17.50 m² 2.20
4.80

4.80

18.47 m² 1.00 Laundry

7.40
4.30

5.20
3.90

3.54 3.50 3.50 3.60

1.20

1.20
15.05 m² Passage

1.10
3.60

3.50

2.00
+4.95 m F.F.L +4.95 m F.F.L 14.35 m² 25.36m² 3.90 1.60
2.50
2.60

2.20
8.75 m²

5.00
0.60
2.10

Plot Limit Plot Limit Maid's Rm.


1.30 Plant Box

3.90
3.29 3.50

3.70
GARDEN 3.60 14.00 m² 9.84 m²

1.20
GARDEN

2.70

2.70
33.31 m² 3.41 m² Kitchen
31.67 m² 3.50 Closet
Plant Box
MULK 118/3131
1.00

1.00

1.00

1.10

3.00 m²
+4.95 m +4.95 m Plant Box 3.50 m²
+4.95 m +4.95 m
6.55 m² 10.14 m²
3.50 m²
MUWAILEH COMM'L.
F.F.L F.F.L F.F.L F.F.L
3.70 m² 0.50 3.60
BLOCK:-

1.20
PLOT NO:-
1.53 3.00 3.50
2 3.90 3.50 0.20 6.55 2.75 Plot Limit
0.65 2.60 1.15 1.20 0.90 0.60 1.70 1.20 2.40 2.60 0.70
Plot Limit GOV. 6086
0.87 2.60 0.20 0.90 2.60 1.35 1.20 1.80 2.60 0.45 0.45 2.60 0.75 2.60 1.70 1.20

F-01 Balcony Outdoor sitting area


15.50 31.00 m²
+18.55 m F.F.L
1.30
DESIGNED BY:- CORDINATED BY:- APPROVED BY:- DRAWING NO. :-
INEC TEAM E.KHALID ALZ
PENTHOUSE PLAN (50%)
TYPICAL 1ST- 4TH FLOOR PLAN FACADE BY:- SCALE:- 1/100 DATE:- JOB NO. :-
SHEET SIZE: A2 INV 314
FOR MUNICIPALITY USE

14/11/2023

NOTE :
All Windows & Balcony Doors Should Be
Equipped with Windows Opening Control
Device (W.O.C.D) To Limits the Opening
Less Than 10cm to have Maximum Opening
Limit of 10cm to help in the Prevention of
Accidental Falls from Windows & Balcony
by Children as per Sharjah Municipality
Regulation

SHARJAH MUNICIPALITY NOTES GENERAL NOTES SYMBOLS & ABBREVIATIONS


1. ALL DIMENSIONS IN CM.
* ALL WINDOWS & BALCONY DOORS SHOULD BE
2. DO NOT SCALE FROM DRAWING.
EQUIPPED WITH WINDOWS OPENING CONTROL ELEVATION NUMBER
DEVICE (W.O.C.D) TO LIMITS THE OPENING LESS 3. ALL DIMENSIONS TO BE VERIFIED ON SITE
THAN 10CM CM TO HAVE MAXIMUM OPENING LIMIT 4. THIS DRAWING TO BE READ IN CONJUCTION
OF 10CM TO HELP IN THE PREVENTION OF WITH RELEVANT ARCH,STRUC & MEP SECTION NUMBER
ACCIDENTAL FALLS FROM WINDOWS AND BALCONY DETAILS & SPECIFICATIONS.
BY CHILDREN AS PER SHARJAH MUNICIPALITY 5. CONTRACTOR MUST CO-ORDINATE
REGULATION.
THESE DRAWINGS AND REPORT IF ANY LEVEL IN PLAN.
DISCREPANCY FOR CLARIFICATION BEFORE
PROCEEDING WITH THE WORK LEVEL IN ELEVATION & SECTION
*ALL EXTERNAL WALL ARE THERMAL INSULATION
BLOCKS WITH MINIMUM 20cm THICKNESS 6. ALL MATERIAL TO BE APPROVED IN WRITEN
BY ENGINEER. FINISHING NOTATION
*ALL WINDOWS ARE REFLECTIVE, DOUBLE GLAZING 7. CONTRACTOR SHOULD SUBMIT THE
SHOP DRAWING FOR APPROVAL. WINDOW NOTATION
8. THE COPY RIGHTS OF THIS PLANS AND
DRAWINGS ARE RESERVED FOR INVESTMENT DOOR NOTATION
ENGINEERING CONSULTANCY. 2007

Rev. No. REVISION Date Status

DESIGN CONSULTANT:

INVESTMENT
Engineering Consultancy
TEL : +971 6 5737979 FAX : +971 6 5737779
P.O.BOX : 1388, SHARJAH , UAE EMAIL : [email protected]
www.investmentengineering.ae

CLIENT'S :-

MR. ABDULAZIZ ABDULLA AHMED MOHAMAD


AL ZAROONI
PROJECT TITLE :-

PROPOSED G+4+PENTHOUSE (50%) BUILDING


DWG. TITLE :

BUILDING SCORE +SPECIFICATIONS


MULK 118/3131
PLOT NO:- BLOCK:- MUWAILEH COMMERCIAL
GOV. 6086
DESIGNED BY:- CORDINATED BY:- APPROVED BY:- DRAWING NO. :-
ENGR. MARIA INEC TEAM E.KHALID ALZ
FACADE BY:- SCALE:- 1/100 DATE:- JOB NO. :-
ENGR. ALBATOUL SHEET SIZE: A2 18-06-2023 INV 314

You might also like