Bill of Quantity

S.N. DESCRIPTION OF ITEM DSR QUANTITY UNIT RATES AMOUNT


1 Earth work in excavation by mechanical means (Hydraulic 2.8
excavator) / manual means in foundation trenches or drains
(not exceeding 1.5 m in width or 10 sqm on plan) including
dressing of sides and ramming of bottoms, lift up to 1.5 m,
including getting out the excavated soil and disposal of surplus
excavated soil as directed, within a lead of 50 m.
All kinds of soil. 2.8.1 24.19 Cum 180.06 4,355.91

2 Excavating, supplying and filling of local earth (including royalty) 2.25a 8.20 Cum 484.55 3,974.09
by mechanical transport up to a lead of 5 km, also including
ramming and watering of the earth in layers not exceeding 20
cm in trenches, plinth, sides of foundation etc., complete.

3 Providing and laying in position cement concrete of specified 4.1


grade excluding the cost of centering and shuttering - All work
up to plinth level :
1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural 4.1.8 10.79 Cum 4712.03 50,829.09
sources : 8 graded stone aggregate 40 mm nominal size derived
from natural sources).

4 Supplying and filling in plinth with sand under floors, including 2.27 5.35 Cum 1469.05 7,857.73
watering, ramming, consolidating and dressing complete.

5 Diluting and injecting chemical emulsion for POST- 2.35


CONSTRUCTIONAL anti- termite treatment (excluding the cost
of chemical emulsion) :
With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. 2.35.3.1 82.39 Sqm 214.47 17,670.11

6 Providing and laying in position specified grade of reinforced 5.1


cement concrete, excluding the cost of centering, shuttering,
finishing and reinforcement - All work up to plinth level :

1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from 5.1.2 4.90 Cum 6257.17 30,660.11
natural sources : 3 graded stone aggregate 20 mm nominal size
derived from natural sources)

7 Reinforced cement concrete work in walls (any thickness), 5.2


including attached pilasters, buttresses, plinth and string
courses, fillets, columns, pillars, piers, abutments, posts and
struts etc. above plinth level up to floor five level, excluding cost
of centering, shuttering, finishing and reinforcement :
1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from 5.2.2 3.00 Cum 7507.25 22,517.47
natural sources : 3 graded stone aggregate 20 mm nominal size
derived from natural sources)

8 Reinforced cement concrete work in beams, suspended floors, 5.3 5.64 Cum 7958.63 44,875.64
roofs having slope up to 15° landings, balconies, shelves,
chajjas, lintels, bands, plain window sills, staircases and spiral
stair cases above plinth level up to floor five level, excluding the
cost of centering, shuttering, finishing and reinforcement with
1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from
natural sources : 3 graded stone aggregate 20 mm nominal
sizederived from natural sources).

9 Reinforced cement concrete work in beams, suspended floors, 5.3 8.46 Cum 8409.12 71,180.28
roofs having slope up to 15° landings, balconies, shelves,
chajjas, lintels, bands, plain window sills, staircases and spiral
stair cases above plinth level up to floor five level, excluding the
cost of centering, shuttering, finishing and reinforcement with
1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from
natural sources : 3 graded stone aggregate 20 mm nominal
sizederived from natural sources).
10 Reinforced cement concrete work in beams, suspended floors, 5.3 2.68 Cum 7958.63 21,344.15
roofs having slope up to 15° landings, balconies, shelves,
chajjas, lintels, bands, plain window sills, staircases and spiral
stair cases above plinth level up to floor five level, excluding the
cost of centering, shuttering, finishing and reinforcement with
1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from
natural sources : 3 graded stone aggregate 20 mm nominal
sizederived from natural sources).
-
11 Brick work with common burnt clay F.P.S. (non modular) bricks 6.1
of class designation 7.5 in foundation and plinth in:
Cement mortar 1:6 (1 cement : 6 coarse sand) 6.1.2 3.70 Cum 4933.55 18,264.25

12 Providing and laying damp-proof course 40mm thick with 4.10 7.86 Sqm 284.19 2,234.68
cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III)
derived from natural sources : 4 graded stone aggregate
12.5mm nominal size derived from natural sources).

13 Providing and applying a coat of residual petroleum bitumen of 4.13 7.86 Sqm 101.10 794.93
grade of VG-10 of approved quality using 1.7 kg per square
metre on damp proof course after cleaning the surface with
brushes and finally with a piece of cloth lightly soaked in
kerosene oil.

14 Half brick masonry with common burnt clay F.P.S. (non 6.12
modular) bricksof class designation 7.5 in foundations and plinth
in :
Cement mortar 1:4 (1 cement : 4 coarse sand) 6.12.2 31.03 Sqm 626.05 19,428.47

15 Steel reinforcement for R.C.C. work including straightening, 5.22


cutting, bending, placing in position and binding all complete
upto plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more. 5.22.6 39.83 Qtl 7460.25 2,97,141.62

16 15 mm cement plaster on rough side of single or half brick wall 13.5


of mix :
1:4 (1 cement: 4 coarse sand) 13.5.1 16.01 Sqm 284.82 4,561.07

17 15 mm cement plaster on rough side of single or half brick wall 13.5


of mix :
(a) 1:6 (1 cement: 6 coarse sand) 13.5.2 86.87 Sqm 273.47 23,755.25

18 Distempering with 1st quality acrylic distemper (ready mixed) 13.41


having VOC content less than 50 gram/litre, of approved
manufacturer, of required shade and colour all complete :

New work (two or more coats) over and including water 13.41.1 86.87 Sqm 128.42 11,155.08
thinnable priming coat with cement primer having VOC content
less than 50 gram/litre

19 New work (two or more coats) over and including water 13.41.1 35.67 Sqm 128.42 4,580.69
thinnable priming coat with cement primer having VOC content
less than 50 gram/litre
-
20 Providing and applying white cement based putty of average 13.80 122.54 Sqm 107.94 13,226.87
thickness 1 mm, of approved brand and manufacturer, over the
plastered wall surface to prepare the surface even and smooth
complete.

21 Providing and laying integral cement based water proofing 22.7


treatment including preparation of surface as required for
treatment of roofs, balconies, terraces etc consisting of
following operations:
With average thickness of 120 mm and minimum thickness at 22.7.1 74.09 Sqm 1165.28 86,335.50
khurra as 65 mm.

22 Providing and fixing Ist quality ceramic glazed wall tiles 8.31 100.53 Sqm 877.07 88,174.49
conforming to IS: 15622 (thickness to be specified by the
manufacturer), of approvedmake, in all colours, shades except
burgundy, bottle green, black of any size as approved by
Engineer-in-Charge, in skirting, risers of steps and dados, over
12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse
sand) and jointing with grey cement slurry @ 3.3kg per sqm,
including pointing in white cement mixed with pigment of
matching shade complete.
23 Providing and laying Vitrified tiles in different sizes (thickness to 11.47
be specified by the manufacturer), with water absorption less
than 0.08%and conforming to IS: 15622, of approved brand &
manufacturer in all colours and shade in skirting, riser of steps,
laid with cement based high polymer modified quick set tile
adhesive (water based) conforming to IS: 15477, in average 6
mm thickness, including grouting of joints(Payment for grouting
of joints to be made separately).
Size of Tile 600x600 mm 11.47.2 14.00 Sqm 1310.06 18,340.79

24 Centering and shuttering including strutting, propping etc. and 5.9


removal of form for :
(a) Foundations, footings, bases of columns, etc. for mass concrete 5.9.1 21.00 Sqm 271.26 5,696.45

(b) Columns, Pillars, Piers, Abutments, Posts and Struts 5.9.6 12.01 Sqm 664.95 7,986.50

(c) Lintels, beams, plinth beams, girders, bressumers and 5.9.5 24.52 Sqm 509.39 12,487.95
cantilevers

(d) Suspended floors, roofs, landings, balconies and access platform 5.9.3 63.23 Sqm 641.40 40,557.28

(d) Lintels, beams, plinth beams, girders, bressumers and 5.9.5 15.75 Sqm 509.39 8,023.95
cantilevers

25 Providing and fixing of laminated PVC flush doors of MR 13.98 Sqm 3325.00 46,488.49
25mm thickness water proof and moisture proof

26 Providing and fixing of uPVC top hung casement MR 1.50 Sqm 1425.00 2,137.50
window

27 Providing and fixing water closet squatting pan (Indian type SOR(17.1)
W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low
level white P.V.C. flushing cistern, including flush pipe, with
manually controlled device (handle lever) conforming to IS :
7231, with all fittings and fixtures complete, including cutting
and making good the walls and floors wherever required:

White Vitreous china Orissa pattern SOR (17.1.1) 2.00 NOS 4681.18 9,362.35
W.C. pan of size580x440 mm with integral type foot rests
28 Providing and fixing white vitreous china pedestal type water SOR(17.2) -
closet (European type W.C. pan) with seat and lid, 10 litre low
level white P.V.C. flushing cistern, including flush pipe, with
manually controlled device (handle lever), conforming to IS :
7231, with all fittings and fixtures complete, including cutting
and making good the walls and floors wherever required :

W.C. pan with ISI marked white solid plastic seat and lid SOR(17.2.1) 3.00 NOS 4506.96 13,520.89
29 Providing and fixing white vitreous china flat back or wall corner SOR(17.4) -
type lipped front urinal basin of 430x260x350 mm and
340x410x265 mm sizes respectively with automatic flushing
cistern with standard flush pipe and C.P. brass spreaders with
brass unions and G.I clampscomplete, including painting of
fittings and brackets, cutting and making good the walls and
floors wherever required :
One urinal basin with 5 litre white SOR(17.4.1) 2.00 NOS 4329.33 8,658.66
P.V.C. automatic flushing cistern
30 Providing and fixing white vitreous china pedestal for wash SOR(17.8) 5.00 NOS 1164.41 5,822.07
basin completely recessed at the back for the reception of pipes
and fittings.
31 Providing and fixing square-mouth S.W. gully trap class SP- SOR(19.4) -
1complete with C.l grating brick masonry chamber with water
tight C.l. cover with frame of 300 x300 mm size (inside) the
weight of cover to be not less than 4 50 kg and frame to be not
less than 2.70 kg as per standard design
100x100 mm size P type SOR(19.4.1) -
With common burnt clay (non modular) bricks of class-150 SOR(19.4.1.1) 10.00 NOS 1872.95 18,729.47
32 Providing and fixing Chlorinated Polyvinyl Chloride DAR(18.8.2) 140.00 RMT 371.87 52,061.94
(CPVC) pipes, having thermal stability for hot & cold water
supply, including all CPVC plain & brass threaded fittings, i/c
fixing the pipe with clamps at 1.00 m spacing. This includes
jointing of pipes & fittings with one step CPVC solvent cement
and the cost of cutting chases and making good the
same including testing of joints complete as per
direction of Engineer in Charge. Concealed work,
including cutting chases and making good the walls etc.
20 mm nominal outer dia
Pipes.
33 Providing & Placing of Looking Mirror pasted on wall with MR 5.01 SQM 2375.00 11,898.75
the help of silicon having edges beveled, all complete as
per drawing, specification and direction as approved by the
Architect/ Engineer
in-Charge. Customized

34 Wiring point for light with 1.5 sqmm.FRLSH PVC S.I 138©+187 (A) 16.00 NOS 621.30 9,940.80
insulated multistrand single core copper condutor
cable in PVC conduit pipe partly concealed in the wall
and partly laid in slab along with the reinforcement
before concreting, complete with 1.5 sq.mm. FRLSH
copper earth contunity wire,modular type switch
& ceiling rose/angle/batten holder on 3mm thick
phenolic paminated backalite sheet etc.complete in all
respects.as directed including matching colour wash.
-
35 Wiring point for fan / fresh air fan (light duty exhaust S.I 140©+187 (A) 5.00 NOS 679.25 3,396.25
fan) with 1.5 sqmm.FRLSH PVC insulated
multistrand single core copper condutor cable in PVC
conduit pipe partly concealed in the wall and partly laid
in slab along with the reinforcement before
concreting, complete with 1.5 sq.mm. FRLSH copper earth
contunity wire,modular type switch & ceiling
rose/angle/batten holder on 3mm thick phenolic
paminated backalite sheet etc.complete in all respects.as
directed including matching colour wash.
-
36 Supply and fixing of power plug with 15A/250 volt flush type S.I 1139+187( C) 5.00 NOS 399.00 1,995.00
switch and 5 pin 15A/250V flush type universal socket in
suitable M.S. box of 175mm x 100mm x 50mm size with
phenolic laminated bakelite sheet cover 3mm thick fixed with
brass machine screw and cup washer.
-
37 Supply and wiring of submain with two number 1.5 S.I 1313© 90.00 RMT 99.75 8,977.50
sq.mm. PVC insulated 1100 V grade single core copper
conductor cable in mm dia heavy duty (2mm thick) PVC
conduit with 1 nos. 1.5 sq. mm. FRLSH PVC insulated 1100
V grade multistrand single core copper conductor cable as
earth continuity wire drawn inside the conduit complete in
all respect.
-
38 Supply fixing and concealing of 20mm dia.2mm thick S.I 148(A) 100.00 RMT 58.90 5,890.00
PVC conduit pipe with ISI mark embossed and with PVC
acessories confirming to IS No. 3419 for drawing wires
duly sealed at joints with original resin/ adhesive to make the
complete piping rigid,plastering with cement sand mortar
finished to level with matching colour including
cost of material labour and T & P etc required for
proper completion of work. asdirected at site by the
engineer in charge.
-
39 Supply and fixing of recess mounting round 15 TO 18 Watt S.I 1403 16.00 NOS 1776.50 28,424.00
LED Down Lighter having Powder coated die cast
aluminium housing with heat sink, diffuser/ Reflector and
driver set complete in all respect. CAT-AAA
-
40 Supply and fixing of brass nickle plated compression S.I 503 (J) 5.00 NOS 116.85 584.25
gland for PVC insulated & armoured served
sheathed, underground cable including rubber ring
etc. complete in all respect. The armouring of the cable
shall be properly connected with the earth as per
direction of Engineer- Incharge. 25 sq. mm 3-1/2
core
-
41 S & F surface/Flush mounting 12ways TPN distribution S.I 1029(A) 1.00 NOS 7353.00 7,353.00
board with additional metal door without MCB complete in
all respect,as directed at site by Engineer in charge. CAT-A

42 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm DAR-19.32.1 1.00 NOS 18581.03 18,581.03
dry brick honey comb shaft with bricks and
S.W. drain pipe 100 mm diameter, 1.8 m long complete as per
standard design.
With common burnt clay F.P.S. (non modular) bricks of class
designation 7.5

-
43 construction of septic tank for 20 MR 1.00 NOS 39724.56 39,724.56
users
-
44 Constructing brick masonry road gully chamber 45x45x77.5 cm DAR-19.28.1 2.00 NOS 4765.84 9,531.68
with bricks in cement mortar 1:4 (1 cement : 4 coarse sand )
with precast R.C.C. vertical grating complete as per standard
design : With common burnt clay F.P.S. (non modular) bricks of
class
designation 7.5
-
45 Providing and placing on terrace (at all floor levels) DAR-18.48 1000.00 LIT 7.61 7,608.97
polyethylene water storage tank, ISI : 12701 marked, with cover
and suitable locking arrangement and making necessary holes
for inlet, outlet and overflow pipes but without fittings and the
base support for tank.
-
46 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, DAR-18.9.3 10.00 MTR 245.84 2,458.39
having thermal stability for hot & cold water supply including all
CPVC plain & brass threaded fittings This includes jointing of
pipes & fittings with one step CPVC solvent cement ,trenching
,refilling & testing of joints complete as per direction of
Engineer in Charge. 25 mm nominal outer dia Pipes

47 20 mm nominal outer dia Pipes DAR-18.9.2 5.00 MTR 189.74 948.70


-
48 Brick work with common burnt clay DAR-6.1.2- 1.62 CUM 4933.55 7,992.35
F.P.S. (non modular) bricks of class designation 7.5 in foundation
and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand)

-
49 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 DAR-11.3.1 5.40 SQM 424.86 2,294.23
graded stone aggregate) finished with a floating coat of neat
cement, including cement slurry, but excluding the cost of
nosing of steps etc. complete. 40 mm thick with 20 mm
nominal size stone aggregate
12 mm cement plaster finished with a floating coat of neat DAR-13.7.2 3.06 SQM 294.36 900.75
cement of mix : 1:4 (1 cement: 4 fine sand)
-
50 Providing and fixing on wall face unplasticised Rigid PVC rain DAR-12.41.2 10.00 MTR 261.06 2,610.57
water pipes conforming to IS : 13592 Type A, including jointing
with seal ring conforming to IS : 5382, leaving 10 mm gap for
thermal expansion, (i) Single socketed pipes. 110 mm diameter

51 Excavating trenches in all kind of soil of required width for


pipes, cables etc. including excavation for sockets and dressing
of sides, ramming of bottoms, depth upto 1.5 m. including
getting out the excavated soil & then returning the soil as
required,
in layers not exceeding 20cm in depth including consolidating 2.10.1
each deposited layer by ramming, watering, etc & disposig of
surplus excavated soil as directed within a lead of 50m.

Pipes, cables etc. exceeding 80mm dia. But not exceeding 300 2.10.1.2 13.00 metre 243.59 3,166.68
mm dia.
-
52 Providing, laying and joining glazed stone ware pipes class SP-1 19.10 -
with stiff mixture of cement mortar in the proportion of 1:1 (1
cement : 1 fine sand) including testing of joints etc. complete.

150mm diameter 19.1.2 13.00 Metre 481.30 6,256.92


-
53 Providing & laying cement concrete 1:5:10 (1 cement :5 coarse 19.20 -
sand :10 graded stone aggregate 40mm nominal size) alround
S.W. Pipes including bed concrete as per standard design.
150mm diameter S.W. Pipe 19.2.2 13.00 Metre 816.13 10,609.70
-
54 Constructing brick masonry manhole in cement mortar 1:4 (1 19.70 -
cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2
coarse sand :4 graded stone aggregate 20mm nominal size),
foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8
graded stone aggregate 40mm nominal size) inside plastering
12mm thick with cement mortar 1:3 (1 cement :3 coarse sand)
finished with floating coat fo neat cement and making channels
in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded
stone aggregate 20mm nminal size) finished with a floating coat
of neat cement complete as per standard design
-
Inside size 90x80cms and 45cms deep including CI cover with 19.7.1 -
frame (light duty) 455x610mm internal diamensions total
weight of cover and frame to be not less than 38 kg (weight of
cover 23 kg and weight of frame 15kg).
With FPS bricks of class designation 75 -
(i) For Sewer Line 19.7.1.1 1.00 Each 8833.70 8,833.70
Extra for depth of man hole size 90x80 cm 19.8.1.1 0.25 metre 6104.74 1,526.19
-
Inside size 90x120 cm & 90 cm deep including C.I. cover with 19.7.2.1 Each 18265.33 -
frame (medium duty) total wt. of cover & frame to be not less
than 116 Kg (wt. of cover 58 Kg & wt. of frame 58 Kg.

Extra for depth of man hole size 90x120 cm 19.8.2.1 metre 7322.25 -
-
55 Providing orange colour safety foot rest of minimum 6mm thick 19.16 4.00 Each 383.01 1,532.03
plastic encapsulated as per IS : 10910 on 12mm dia steel bar
conforming to IS: 1786 having minimum cross section as 23 mm
x25mm and over all minimum length 263mm and width as
165mm with minimum 112mm space between protruded legs
having 2mm tread on top surface by ribbing or chequering
besides necessary and adequate anchoring projections on tail
length on 138 mm as per standard drawing and suitable to with
stand the bend test and chemical resistance test as per
specifications and having manufactures's permanent
identification mark to be visible even after fixing, including
fixing in manholes with 30x20x15 cm cement concrete block
1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate
20mm nominal size) complete as per design.
-
56 Making connection of drain or sewer line with existing manhole 19.21 -
including breaking into and making good the walls, floors with
cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded
stone aggregate 20mm nominal size) cement plastered on both
sides with cement mortar ( 1 cement : 3 coarse sand) finished
with a floating coat of neat cement and making necessary
channels for the drain etc. complete :

For pipes 100 to 250mm diameter 19.21.1 1.00 Each 560.61 560.61
-
57 Excavating trenches in all kind of soil of required width for 2.10.1 -
pipes, cables etc. including excavation for sockets and dressing
of sides, ramming of bottoms, depth upto 1.5 m. including
getting out the excavated soil & then returning the soil as
required,
in layers not exceeding 20cm in depth including consolidating -
each deposited layer by ramming, watering, etc & disposig of
surplus excavated soil as directed within a lead of 50m.

Pipes, cables etc. not exceeding 80mm dia. 2.10.1.1 38.00 metre 149.14 5,667.16
-
58 Provding and fixing gun metal non return valve of approved 18.19 -
quality (screwed end)
50 mm nominal bore 18.19.4 -
Vertical 18.19.4.2 1.00 Each 999.65 999.65
-
59 Providing & fixing G.I. pipes complete with G.I. fittings including 18.12 -
tenching and refilling etc.
External work -
32mm nominal bore. 18.12.4 13.00 metre 373.74 4,858.60
50mm nominal bore. 18.12.6 28.00 metre 527.20 14,761.53
-
60 Providing & fixing sand of grading zone V or coaser grade 18.41 -
alround the G.I. Pipes in external work.
32 mm diameter pipe 18.41.4 13.00 metre 114.07 1,482.85
50 mm diameter pipe 18.41.6 28.00 metre 119.84 3,355.55
-
61 Providing and fixing gate valve (with cap complete with bolts, 18.17 -
nuts, rubber insertion etc.
32 mm nominal bore 18.17.2 1.00 Each 477.01 477.01
50 mm nominal bore 18.17.4 2.00 Each 710.16 1,420.32
-
62 Constructing masonry Chamber 60x60x75 cm, inside with 75 18.33 -
class designation brick work in cement mortar 1:4 (1 cement :4
coarse sand ) for sluice valve, with C.I. surface box 100mm top
diameter, 160mm bottom diameter and 180mm deep (inside)
with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse
sand : 4 graded stone aggregate 20mm nominal size) necessary
excavation foundation concrete 1:5:10 (1 cement : 5 fine sand :
10 graded stone aggregate 40mm nominal size) and inside
plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12
mm thick finished with a floating coat of neat cement complete
as per standard design :
With F.P.S. bricks 18.33.1 3.00 Each 7513.79 22,541.36
-
63 Making connection of G.I. distribution branch with G.I. main of 18.13 -
following sizes by providing and fixing tee, including cutting and
threading the pipe etc. complete :
25 to 40 mm dia nominal bore 18.13.1 1.00 Each 630.78 630.78
50 to 80 mm dia nominal bore 18.13.2 2.00 Each 1234.97 2,469.94

64 Earth work in excavation by mechanical means (Hydraulic D.S.R.-2.8.1 74.91 CUM 180.06 13,488.33
excavator)/manual means over areas (exceeding 30 cm in
depth, 1.5 m in width as well as 10 sqm on plan) including
getting out and disposal of excavated earth lead upto 50 m and
lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil

-
a Filling available excavated earth (excluding rock) in trenches, (D.S.R.-2.25) 52.44 CUM 135.58 7,109.49
plinth,sides of foundations etc. in layers not exceeding 20cm in
depth, consolidating each deposited layer by ramming and
watering, lead up to 50 m and lift upto 1.5 m.

-
65 Excavating, supplying and filling of local earth (including royalty) (D.S.R.-2.25a) 30.71 CUM 484.55 14,880.65
by mechanical transport upto a lead of 5km also including
ramming and watering of the earth in layers not exceeding 20
cm in trenches, plinth, sides of foundation etc. complete.

-
66 Providing and laying cement concrete 1:4:8 (1 cement :4 coarse (D.S.R.-4.1.8) 23.33 CUM 4712.03 1,09,940.05
sand :8 graded Stone aggregate 40 mm nominal size) including
supply of all materials, labour T & P rtc required for proper
completion of the work and curing complete also including cost
of formwork in foundation & floors.
-
67 Supplying and filling in plinth with sand under floors, including (D.S.R.-2.27) 21.27 CUM 1469.05 31,251.77
watering, ramming, consolidating and dressing complete.

-
68 Treatment of soil under existing floors using chemical emulsion -
@ one litre per hole, 300 mm apart including drilling 12 mm
diameter holes and plugging with cement mortar 1:2 (1
cement:2 coarse sand) to match the existing floor.

With Chlorpyriphos/ Linadane E.C. 20% with 1% concentration. (D.S.R.-2.35.3.1) -

151.72 SQM 214.47 32,539.04


-
69 Reinforced cement concrete work in beams, suspended floors, (D.S.R.-5.3) -
roofs having slope up to 15° landings, balconies, shelves,
chajjas, lintels,
bands, plain window sills, staircases and spiral stair cases above
plinth level up to floor five level, excluding the cost of centering,
shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :
1.5 coarse sand(zone-III) derived from natural sources : 3
graded stone aggregate 20 mm nominal size derived from
natural sources). Lintel
(a) Ground Floor 1.12 CUM 7958.63 8,951.08
-
70 Reinforced cement concrete work in beams, suspended floors, (D.S.R.-5.3) -
roofs having slope up to 15° landings, balconies, shelves,
chajjas, lintels,
bands, plain window sills, staircases and spiral stair cases above
plinth level up to floor five level, excluding the cost of centering,
shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :
1.5 coarse sand(zone-III) derived from natural sources : 3
graded stone aggregate 20 mm nominal size derived from
natural sources). Slab
(a) Ground Floor 27.47 CUM 7958.63 2,18,616.19
-
71 Reinforced cement concrete work in beams, suspended floors, (D.S.R.-5.3) -
roofs having slope up to 15° landings, balconies, shelves,
chajjas, lintels,
bands, plain window sills, staircases and spiral stair cases above
plinth level up to floor five level, excluding the cost of centering,
shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :
1.5 coarse sand(zone-III) derived from natural sources : 3
graded stone aggregate 20 mm nominal size derived from
natural sources). Beam
Above Plinth 9.73 CUM 7958.63 77,448.77
Providing and laying in position specified grade of reinforced -
cement concrete, excluding the cost of centering, shuttering,
finishing and
reinforcement - All work up to plinth level :
1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from (D.S.R.-5.1.2) 7.20 CUM 6257.17 45,028.78
natural sources : 3 graded stone aggregate 20 mm nominal size
de rived from natural sources)
-
72 Providing and laying in position specified grade of reinforced -
cement concrete, excluding the cost of centering, shuttering,
finishing and
reinforcement - All work up to plinth level :
1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from (D.S.R.-5.1.2) 8.37 CUM 6257.17 52,393.87
natural sources : 3 graded stone aggregate 20 mm nominal size
de rived from natural sources)
-
73 Reinforced cement concrete work in beams, suspended floors, (D.S.R.-5.3) -
roofs having slope up to 15° landings, balconies, shelves,
chajjas, lintels,
bands, plain window sills, staircases and spiral stair cases above
plinth level up to floor five level, excluding the cost of centering,
shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :
1.5 coarse sand(zone-III) derived from natural sources : 3
graded stone aggregate 20 mm nominal size derived from
natural sources). Column
(a) Ground Floor 9.55 CUM 7958.63 75,996.00
-
74 Brick work with common burnt clay F.P.S. (non modular) bricks (D.S.R.-6.1.2) 19.58 CUM 4934.03 96,608.41
of class designation 7.5 in foundation and plinth in:Cement
mortar 1:6 (1 cement : 6 coarse sand)
-
75 Providing and laying damp-proof course 40 mm thick with (DSR-4.10) 6.13 SQM 284.19 1,742.78
cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded
stone aggregate 12.5 mm nominal size).
-
76 Painting on D.P.C. with two coats of airblown bitumen 85/50 (DSR-4.13) 6.13 SQM 101.10 619.95
or 85/25 @ 1.7 kg/sqm approx. including cost of fuel if any.

-
77 Brick work with common burnt clay F.P.S. (non modular) bricks (D.S.R.-6.4.2) -
of class designation 7.5 in superstructure above plinth level up
to floor V level in all shapes and sizes in :Cement mortar 1:6 (1
cement : 6 coarse sand)
(a) Ground Floor 16.14 CUM 6298.81 1,01,649.60
-
78 Half brick masonry with common burnt clay F.P.S. (non (D.S.R.-6.13.2) -
modular) bricks of class designation 7.5 in superstructure above
plinth level up to floor V level.Cement mortar 1:4 (1 cement :4
coarse sand)
(a) Ground Floor 6.70 SQM 777.36 5,204.75
-
79 Steel reinforcement for R.C.C. work including straightening, (D.S.R.-5.22.6) -
cutting, bending, placing in position and binding all complete
upto plinth level.Thermo-Mechanically Treated bars of grade Fe-
500D or more.
(a) Ground Floor 118.65 QTL 7460.25 8,85,131.71
-
80 15 mm cement plaster on rough side of single or half brick wall (DSR-13.5.1) 19.13 SQM 284.82 5,449.70
of mix : 1:4 (1 cement: 4 coarse sand).
-
81 15 mm cement plaster on rough side of single or half brick wall (DSR-13.5.2) -
of mix:1:6 (1 cement: 6 coarse sand)
(a) Ground Floor 256.54 SQM 273.47 70,157.70
-
82 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand) (DSR-13.4.2) -
(a) Ground Floor 351.94 SQM 237.71 83,659.65
-
83 Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a (DSR-13.9.1) -
floating coat of neat cement.12 mm cement plaster
(a) Ground Floor 210.04 SQM 310.96 65,315.24
-
84 Add for plaster drip course/ groove in plastered surface or (DSR-5.30) 75.63 RM 54.23 4,101.72
moulding to R.C.C. projections.
-
85 Providing and laying vitrified floor tiles in different sizes (D.S.R.-11.41.2) 108.76 SQM 1074.56 1,16,869.05
(thickness to be specified by the manufacturer) with water
absorption less than 0.08% and conforming to IS: 15622, of
approved make, in all colours and shades, laid on 20mm thick
cement mortar 1:4 (1 cement : 4 coarse sand), jointing with
grey cement slurry @ 3.3 kg/ sqm including grouting the joints
with white cement and matching pigments etc., complete.Size
of Tile 600x600 mm
-
86 Providing and laying Vitrified tiles in different sizes (thickness to (D.S.R.-11.46.2) 8.22 SQM 1122.70 9,228.62
be specified by manufacturer), with water absorption less than
0.08 % and conforming to I.S. 15622, of approved make, in all
colours & shade, in skirting, riser of steps, over 12 mm thick bed
of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with
grey cement slurry @ 3.3 kg/ sqm including grouting the joint
with white cement & matching pigments etc. complete.Size of
Tile 600x600 mm
-
87 Providing and fixing 18mm thick gang saw cut mirror polished (DSR-8.2.2.2 ) -
premoulded and prepolished) machine cut for kitchen
platforms, vanity counters, window sills , facias and similar
locations of required size of approved shade, colour and texture
laid over 20mm thick base cement mortar 1:4 (1 cement : 4
coarse sand) with joints treated with white cement, mixed with
matching pigment, epoxy touch ups, including rubbing, curing,
moulding and polishing to edges to give high gloss finish etc.
complete at all levels. Granite of any colour and shade.
(FLOORING)
(a) Ground Floor 50.75 SQM 3552.90 1,80,308.88
-
88 Providing and fixing 18mm thick gang saw cut mirror polished (DSR-8.2.2.2 ) -
premoulded and prepolished) machine cut for kitchen
platforms, vanity counters, window sills , facias and similar
locations of required size of approved shade, colour and texture
laid over 20mm thick base cement mortar 1:4 (1 cement : 4
coarse sand) with joints treated with white cement, mixed with
matching pigment, epoxy touch ups, including rubbing, curing,
moulding and polishing to edges to give high gloss finish etc.
complete at all levels. Granite of any colour and shade. (skirting)
(a) Ground Floor 4.05 SQM 3552.90 14,397.25
-
89 Making plinth protection 50mm thick of cement concrete 1:3:6 (DSR-4.17 ) 48.17 SQM 471.51 22,711.88
(1 cement : 3 coarse sand (zone-III) derived from natural
sources : 6 graded stone aggregate 20 mm nominal size derived
from natural sources) over 75mm thick bed of dry brick ballast
40 mm nominal size, well rammed and consolidated and
grouted with fine sand, including necessary excavation, levelling
& dressing & finishing the top smooth.

-
90 Providing and fixing ISI marked flush door shutters conforming -
to IS : 2202 (Part I) non-decorative type, core of block board
construction with frame of 1st class hard wood and well
matched commercial 3 ply veneering with vertical grains or
cross bands and face veneers on both faces of shutters:

(a) 35 mm thick including ISI marked Stainless Steel butt hinges (DSR-9.21.1) 3.99 SQM 1655.05 6,603.67
with necessary screws. Single leaf.
(b) Double leaf ((DSR-9.21.1+9.26) SQM 1728.79 -
Both side laminated D.S.R. 9.22.1*2 3.99 SQM 661.29 2,638.54
-
91 Providing and fixing factory made uPVC door frame made of D.S.R.-9.117.1 10.30 RM 186.90 1,925.11
uPVC extruded sections having an overall dimension as below
(tolerance ±1mm), with wall thickness 2.0 mm (± 0.2 mm),
corners of the door frame to be Jointed with galvanized
brackets and stainless steel screws, joints mitred and Plastic
welded. The hinge side vertical of the frames reinforced by
galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm)
wall thickness and 3 nos. stainless steel hinges fixed to the
frame complete as per manufacturer’s specification and
direction of Engineerin-
charge.Extruded section profile size 48x40 mm
-
-
92 including drilling of holes for fixing hardware's and drainage of -
water etc. After fixing frame the gap between frame and
adjacent finished wall shall be filled with weather proof silicon
sealent over backer rod of required size and of approved
quality, all complete as per approved drawing & direction of
Engineer-in-Charge. (Single / double glass panes, wire mesh and
silicon sealent shall be paid separately). Variation in profile
dimension in higher side shall be accepted but no extra
payment on this account shall be made.Note: For uPVC frame
and sash extruded profiles minus 5% tolerance
in dimension i.e. in depth & width of profile shall be acceptable.

Three track three panels sliding window with two glazed & one -
wire mesh panels with alluminium channel for roller track, wool
pile, nylon rollers with s.s. 304 body.
Using R2 series with foame (70mm & above)x(40 mm & above) D.S.R.-9.147 A4.1 -
& both glazed and fly screen sash (25 mm & above)x(50mm &
above with zinc alloy (zamak) powder coated touch lock with
hook (Height up to 1.20 meter)
34.56 SQM 7604.51 2,62,811.72
-
93 Distempering with oil bound washable distemper of approved (DSR-13.41.1) -
brand and manufacture to give an even shade :New work (two
or more coats) over and including water thinnable priming coat
with cement primer. (For Internal wall surface)

(a) Ground Floor 256.54 SQM 128.42 32,944.93


-
94 Finishing walls with Premium Acrylic Smooth exterior paint with (DSR-13.47.1) -
Silicone additives of required shade:New work (Two or more
coats applied @ 1.43 ltr/10 sqm over and including priming coat
of exterior primer applied @ 2.20 kg/10 sqm)(Outer surface)

(a) Ground Floor 351.94 SQM 118.35 41,653.33


-
95 Distempering (Two coat) with oil bound distemper of approved (DSR-13.41.1) -
brand and manufacture & of required shade on undecorated
wall surface to give an even shade over & including a priming
coat with cement primer of approved brand & manufacture
such as Berger,J&N, Shalimar, Asian paints after thoroughly
brushing the surface free from mortar droppings & other
foreign matters & also including preparing the surface even
with plaster of paris or approved synthetic material & sand
papered smooth including cost ofall materials. (For ceiling
surface)
(a) Ground Floor 210.04 SQM 128.42 26,973.14
-
96 Providing and applying white cement based putty of average D.S.R.-13.80 -
thickness 1 mm, of approved brand and manufacturer, over the
plastered wall surface to prepare the surface even and smooth
complete.
(a) Ground Floor 818.52 SQM 107.94 88,354.23
-
97 Providing and laying integral cement based water proofing -
treatment including preparation of surface as required for
treatment of roofs, balconies, terraces etc consisting of
following operations: a) Applying a slurry coat of neat cement
using 2.75 kg/sqm of cement admixed with water proofing
compound conforming to IS. 2645 and approved by Engineer-in-
charge over the RCC slab including adjoining walls upto 300 mm
height including cleaning the surface before treatment. b)
Laying brick
bats with mortar using broken bricks/brick bats 25 mm to 115
mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse
sand) admixed with water proofing compound conforming to IS
: 2645 and approved by Engineer-in-charge over 20 mm thick
layer of cement mortar of mix 1:5
(1 cement :5 coarse sand ) admixed with water proofing
compound conforming to IS : 2645 and approved by Engineer-in-
charge to required slope and treating similarly the adjoining
walls upto 300 mm height
including rounding of junctions of walls and slabs c) After two
days of
proper curing applying a second coat of cement slurry using
2.75 kg/ sqm
of cement admixed jointless cement mortar of mix 1:4 (1
cement :4 coarse
sand) admixed with water proofing compound conforming to IS
: 2645
and approved by Engineer-in-charge including laying glass fibre
cloth of
approved quality in top layer of plaster and finally finishing the
surface with
trowel with neat cement slurry and making pattern of 300x300
(DSR-22.7.1) 139.87 SQM 1165.28 1,62,989.20
-
98 Providing and fixing 150 mm bright finished floor brass door (DSR- 14.34) 2.00 NOS. 187.77 375.54
stopper with rubber cushion, necessary brass screws etc. to suit
shutter thickness complete.
-
99 Providing & fixing Stainless steel sliding door bolts ISI marked M.R. 2.00 NOS 856.90 1,713.80
anodised (anodic coating not less than grade AC 10 as per IS :
1868) transparent or dyed to required colour or shade with nuts
and screws etc complete. (a) 250mm x 16mm .

-
100 Providing and fixing stainless steel towerbolts (barrel type) with -
necessary screws etc. complete
(a) 300 mm x 10mm M.R. 2.00 NOS 478.80 957.60
(b) 200 x 10mm M.R. 2.00 NOS 399.00 798.00
-
101 Providing and fixing stainless steel handles with screws etc. M.R. 4.00 NOS 280.25 1,121.00
complete (a) 150 mm
-
102 Providing & fixing glass panes with putty and glazing clips in (DSR-10.30.1) 40.50 SQM 736.44 29,825.99
steel doors, windows, clerestory windows, all complete with :
4.0 mm thick glass panes
-
103 Providing precast cement concrete Jali 1:2:4 (1 cement : 2 (DSR-5.18) 3.24 SQM 1180.46 3,824.70
coarse sand(zone-III) : 4 graded
stone aggregate 6mm nominal size ), reinforced with 1.6 mm
dia mild steel wire, including centering and shuttering,
roughening cleaning, fixing and finishing in cement mortar 1:3
(1 cement: 3 fine sand) etc. complete, excluding plastering of
the jambs, sills and soffits
-
104 Providing and fixing tiled false ceiling of specified materials of -
size 595x595 mm in true horizontal level, suspended on inter
locking metal grid of hot dipped galvanized steel sections (
galvanized @ 120 grams/ sqm, both side inclusive) consisting of
main "T" runner with suitably spaced joints to get required
length and of size 24x38 mm made from 0.30 mm thick
(minimum) sheet, spaced at 1200 mm center to center and
cross "T" of size 24x25 mm made of 0.30 mm thick (minimum)
sheet,
1200 mm long spaced between main "T" at 600 mm center to -
center to form a grid of 1200x600 mm and secondary cross "T"
of length 600 mm and size 24x25 mm made of 0.30 mm thick
(minimum) sheet to be interlocked at middle of the 1200x600
mm panel to form grids of 600x600 mm and wall angle of size
24x24x0.3 mm and laying false ceiling tiles of approved texture
in the grid including, required cutting/making, opening for
services like diffusers, grills, light fittings, fixtures, smoke
detectors etc. Main "T" runners to be suspended from ceiling
using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to
ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm
GI adjustable rods with galvanised butterfly level clips of size 85
x 30 x 0.8 mm spaced at 1200 mm center to center along main
T, bottom exposed width of 24 mm of all T-sections shall be pre-
painted with polyester paint, all complete for all heights as per
specifications, drawings and as directed by Engineer-in-charge.

GI Metal Ceiling Lay in perforated Tegular edge global white (DSR - 12.52.2 ) 99.40 SQM 1316.32 1,30,841.89
color tiles of size 595x595 mm and 0.5 mm thick with 8 mm
drop; made of GI sheet having galvanizing of 100 gms/sqm
(both sides inclusive) and 20% perforation area with 1.8 mm dia
holes and having NRC (Noise Reduction Coefficient ) of 0.5,
electro statically polyester powder coated of thickness 60
microns (minimum), including factory painted after bending and
perforation, and backed with a black Glass fiber acoustical
fleece.
-
105 Providing and fixing 1mm thick M.S. sheet door with frame of (DSR - 10.5.1 ) 6.12 SQM 4015.01 24,571.86
40x40x6 mm angle iron and 3 mm M.S. gusset plates at the
junctions and corners, all necessary fittings complete, including
applying a priming coat of approved steel primer.Using M.S.
angels 40x40x6 mm for diagonal braces
-
106 Centering and shuttering including strutting, propping etc. and -
removal of form for :
-
a) Foundations, footings, bases of columns, etc. for mass concrete D.S.R.-5.9.1 40.32 SQM 271.26 10,937.19

-
(b) Suspended floors, roofs, landings, balconies and access platform D.S.R.-5.9.20 210.04 SQM 711.37 1,49,416.51
with water proof ply 12 mm thick
-
(c) Lintels, beams, plinth beams, girders, bressumers and D.S.R.-5.9.21 162.71 SQM 582.40 94,758.95
cantilevers with water proof ply 12 mm thick
-
(d) Columns, Pillars, Piers, Abutments, Posts and Struts D.S.R.-5.9.6 109.13 SQM 664.95 72,566.49
-
107 Providing and fixing stainless steel ( Grade 304) railing made of D.S.R.-10.28 148.00 SQM 534.01 79,033.65
Hollow tubes, channels, plates etc., including welding, grinding,
buffing, polishing and making curvature (wherever required)
and fitting the same with necessary stainless steel nuts and
bolts complete, i/c fixing the railing with necessary accessories
& stainless steel dash fasteners , stainless steel bolts etc., of
required size, on the top of the floor or the side of waist slab
with suitable arrangement as per approval of Engineer-in-
charge, (for payment purpose only weight of stainless steel
members shall be considered excluding fixing accessories such
as nuts, bolts, fasteners etc.).
108 Providing and fixing on wall face unplasticised Rigid PVC rain 12.41
water pipes conforming to IS : 13592 Type A including jointing
with seal ring conforming to IS : 5382 leaving 10 mm gap for
thermal expansion . (i) Single socketed pipes.
110mm diameter 12.41.2 12.00 Metre 261.06 3,132.68
-
109 Making khurras 45x45 cm with average minimum thickness of 5 12.22 2.00 Each 206.31 412.61
cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded
stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1
m x 400 micron, finished with 12 mm cement plaster 1:3 (1
cement : 3 coarse sand) and a coat of neat
cement,punning,rounding the edges and making and finishing
the outlet complete.
-
110 Providing and fixing unplasticised -PVC pipe clips of approved 12.43 -
design to unplasticised - PVC rain water pipes by means of
50x50x50mm hard wood plugs, screwed with M.S. screws of
required length including cutting brick work and fixing in
cement mortar 1:4 (1 cement : 4 coarse sand) and making good
the wall etc. complete.
110mm 12.43.2 4.00 Each 256.84 1,027.35
-
111 Providing and fixing to the inlet mouth of rain water pipe cast 12.44 2.00 Each 37.84 75.67
iron grating 15 cm diameter and weighing not less than 440
grams.

112 Wiring for light point/ fan point/ exhaust fan point/ call bell 1.10
point with 1.5 sq.mm FRLS PVC insulated copper conductor
single core cable in surface / recessed medium class PVC
conduit, with modular type switch, modular plate, suitable size
G.I. box and earthing the point with 1.5 sq.mm. FRLS PVC
insulated copper conductor single core cable etc as required.

Group C 1.10.3 27.00 Point 1059.60 28,609.33


-
113 Wiring for circuit/sub-main wiring along with earth wire with 1.14 -
the following size of FRLS PVC insulated copper conductor,
single core cable in surface/ recessed medium class PVC
conduit as required.
-
2X1.5 sqmm + 1x1.5 sqmm earth wire 1.14.1 135.00 Metre 168.29 22,719.75
2X2.5 sqmm + 1x 2.5 sqmm earth wire 1.14.2 55.00 Metre 198.63 10,924.69
2X4.0 sqmm + 1x 4.0 sqmm earth wire 1.14.3 45.00 Metre 241.25 10,856.07
-
114 Supply and fixing of stepped type electronic fan regulator on 1.25 8.00 Each 266.53 2,132.21
the existing modular plate switch box including connections but
excluding modular plate etc. as required.

-
115 Supplying and fixing modular blanking plate on the existing 1.26 10.00 Each 28.89 288.92
modular plate & switch box excluding modular plate as required.

-
116 Supplying and fixing suitable size GI box with modular plate and 1.31 7.00 Each 344.53 2,411.74
cover in front on surface or in recess including providing and
fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular
switch,connection etc. as required.
-
117 Supplying and fixing suitable size GI box with modular plate and 1.32 2.00 Each 423.26 846.53
cover in front on surface or in recess including providing and
fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A
modular switch,connection etc. as required.

-
118 Instalation,testing & commissioning of wall bracket /ceiling 1.35 7.00 Each 85.95 601.67
fittings of all sizes and shapes containing upto two GLSCFL/LED
lamps per fitting, complete with all accessories including
connection etc. as required.
-
119 Installation, testing and commissioning of prewired, flourescent 1.41 12.00 Each 148.79 1,785.51
fitting / compact fluorescent fitting of all types, complete with
all accessories and tubes etc. directly on ceiling / wall, including
connection with 1.5 sq. mm. PVC insulated, copper conductor,
single core cable etc. as required.

-
120 Installation, testing and commissioning of ceiling fan, including 1.45 8.00 Each 244.86 1,958.86
wiring the down rods of standard length (upto 30 cm) with 1.5
sq. mm FRLS PVC insulated, copper conductor, single core cable
etc. Including providing and fixing phenolic laminated sheet
cover on the fan box etc. as required.

-
121 Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as 1.49 20.00 Each 41.17 823.41
required.
-
122 Providing and fixing circular/Hexagonal cast iron or M.S. sheet 14.15(rate taken 8.00 Each 159.37 1,274.99
box for ceiling fan clamp, of internal dia 140 mm, 73mm height, from DSR-Civil-
top lid of 1.5 mm thick M.S. sheet with its top surface hacked 2023-10.18)
for proper bonding, top lid shall be screwed into the cast
iron/M.S. sheet box by means of 3.3 mm dia round headed
screwed, one loc at the conrners. Clamp shall be made of 12
mm dia M.S. bar bent to shape as per standard drawing.

-
123 Supply, Installation, Testing and Commissioning of 1200 mm 19.10 8.00 Each 1971.86 15,774.89
sweep, BEE 5 star rated, ceiling fan with Brush Less Disect
Current(BLDC) motor, class of insulation: B, 3 nos. blades, 30 cm
long down rod, 2 nos. canopies, shackle kit, safety rope, copper
winding, Power Factor not less than 0.9, Service
Value(CM/M/W) minimum 6, Air delivery minimum 210
Cum/Min, 350 RPM(tolerance as per IS: 374-2019), THD less
than 10% remote or electronic regulator unit for speed control
and all remaining accessories including safety pin, nut bolts,
washers, temperature rise= 75 degree C(max.), insulation
resistance more than 2 mega ohm, suitable for 230 V, 50 Hz,
single phase AC Supply, earthing etc. complete as required.
-
DISTRIBUTION BOARDS, MCB'S & ISOLATORS : -
-
124 Supplying and fixing following way, Horizontal type three pole 2.4 -
and neutral MCB distribution board, 415 volts on surface
/recess complete with , tinned copper busbar, neutral busbar,
earth bar, din bar, interconnections, powder painted including
earthing etc. as required (But without MCB / RCCB / Isolators).

4 way (4 + 12), Double door 2.4.1 1.00 Each 2954.90 2,954.90


-
125 Supplying and fixing 5 amps. to 32 amps. rating, 240 volts `C' 2.10 -
series, miniature circuit breaker (MCB) suitable for inductive
load of following poles in the existing MCB DB complete
with connections, testing and commissioning etc. as required.

Single Pole 2.10.1 8.00 Each 184.91 1,479.26


-
126 Supplying and fixing single pole, blanking plate in the existing 2.11 4.00 Each 9.39 37.56
MCB DB complete etc. as required.
-
127 Supply and fixing following rateing four pole, 415 V, isolator in 2.13 -
the existing existing MCB DB complete with connections,
testing and commissioning etc. as required.
40 A 2.13.1 1.00 Each 700.62 700.62
-
128 Suplying and fixing cable end box(Loose Wire Box) suitable for 2.24 -
following triple pole and neutral, sheet steel, MCB distribution
borad, 415 Volts, on surface/recess, complete with testing and
commissoning ect. As required.
For 4 way, Double Door TPNMCBDB 2.24.1 1.00 Each 780.08 780.08
-
129 Earthing with GI earth pipe, 600 mm X 600 mm X 6 mm thick 5.4 1.00 Set 5396.98 5,396.98
including accessories and providing masonary enclosure with
cover plate having locking arrangement and watering pipe of
2.7 metre long etc, with charcoal/cock and salt as required.

-
130 Supplying and Laying of 25 mm X 3 mm G.I strip at 0.50 metre 5.9 25.00 Meter 104.01 2,600.26
below ground as strip earth electrode, including connection /
terminating with nut, bolt, spring, washer etc. as required.(
jointing shall be done by overlapping and with 2 sets of G.I. nut
bolt & spring washer spaced at 50mm)
-
131 Laying of one number PVC insulated and PVC sheathed/XLPE 7.10 -
power cable of 1.1 KV grade of following size direct in ground
including excavation, sand cushioning, protective covering and
refilling the trench etc. as required.
Upto 35 sq. mm 7.1.1 50.00 Metre 279.53 13,976.38
-
132 Supplying & making end termination with brass compression 9.10 -
gland and aluminium lugs for the following size of PVC sheathed
/ XLPE aluminium conductor cable of 1.1 KV grade as required.

2 X 10 sqmm. (19mm) 9.20 2.00 Each 174.07 348.15


4 X 10 sqmm. (25mm) 9.32 2.00 Each 194.30 388.59
-
133 Providing, laying and fixing following dia G.I. pipe (medium 14.13 -
class) in ground complete with G.I. fittings including trenching
(75 cm deep) and refilling etc as required.
100 mm Dia 14.13.3 15.00 Metre 1304.46 19,566.93
-
134 Supply of following size of 1.1 KV grade multicore aluminium MR -
conductor PVC sheathed armoured cable as per IS 1554. Make-
Polycab or Eq
10 sqmm 2 core 15.00 Metre 138.70 2,080.50
10 sqmm 4 core 35.00 Metre 171.95 6,018.25
-
SUPPLY OF LIGHT FIXTURES : -
-
135 Supply of LED Tube Light with batten suitable for up to 1X20 MR 12.00 Each 574.75 6,897.00
watt LED tube light complete including tube etc. on
surface/Pendent complete in all respect. Make-Philips or Eq
-
136 Supply of recess/Surface/Pendent mounting round 10 to 15 MR 7.00 Each 1957.00 13,699.00
watt LED Down Lighter having Powder coated die cast
aluminium housing with heat sink, diffuser/Reflector and driver
set complete in all respects.Make-Philips or Eq
-
137 Supply of service bracket of 50mm. Dia 4 meter long fabricated MR 2.00 Each 2047.25 4,094.50
from class ''B'' G.I. pipe complete with two bend, socket, wall
clamps. 7/3.15 mm G.I. stay wire, stay insulators etc..complete
in all respects.
-
138 Supply of LED street light fitting having die cast aluminium body MR 2.00 Each 7210.50 14,421.00
and diffuser/reflector with driver set suitable for 75 watt to 90
Watt confirming to IP 66 protection complete in all
respect.Make-Philips or Eq

139 40 mm thick fine dressed stone flooring over 20 mm (average) (D.S.R.-11.28.1) 68.70 CUM 885.48 60,832.22
thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with
joints finished flush
-
140 Extra for pre finished nosing in treads of steps of Kota stone/ (D.S.R.-11.31 135.00 MTR 132.40 17,873.46
sand stone slab.

141 Earth work in excavation by mechanical means (Hydraulic D.S.R.-2.8.1 19.66 CUM 180.06 3,540.19
excavator)/manual means over areas (exceeding 30 cm in
depth, 1.5 m in width as well as 10 sqm on plan) including
getting out and disposal of excavated earth lead upto 50 m and
lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil

-
142 Excavating, supplying and filling of local earth (including royalty) (D.S.R.-2.25a) CUM 484.55 -
by mechanical transport upto a lead of 5km also including
ramming and watering of the earth in layers not exceeding 20
cm in trenches, plinth, sides of foundation etc. complete.

-
143 Providing and laying cement concrete 1:4:8 (1 cement :4 coarse (D.S.R.-4.1.8) 3.57 CUM 4712.03 16,807.04
sand :8 graded Stone aggregate 40 mm nominal size) including
supply of all materials, labour T & P rtc required for proper
completion of the work and curing complete also including cost
of formwork in foundation & floors.
-
144 Supplying and filling in plinth with sand under floors, including (D.S.R.-2.27) 1.55 CUM 1469.05 2,283.61
watering, ramming, consolidating and dressing complete..

-
145 Along external wall where the apron is not provided using -
chemical emulsion @ 7.5 litres / sqm of the vertical surface of
the substructure to a depth of 300mm including excavation
channel along the wall & rodding etc. complete:
With Chlorpyriphos/Lindane E.C. 20% with 1% concentration (D.S.R.-2.35.3.1) 15.00 SQM 214.47 3,217.04

-
146 Reinforced cement concrete work in beams, suspended floors, (D.S.R.-5.3) -
roofs having slope up to 15° landings, balconies, shelves,
chajjas, lintels, bands, plain window sills, staircases and spiral
stair cases above plinth level up to floor five level, excluding the
cost of centering, shuttering, finishing and reinforcement with
1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from
natural sources : 3 graded stone aggregate 20 mm nominal size
derived from natural sources). Lintel
(a) Ground Floor 0.93 CUM 7958.63 7,413.47
-
147 As in item no. 6 above but for slabs (Using M-20 Mix concrete). (D.S.R.-5.3) -

(a) Ground Floor 4.33 CUM 7958.63 34,484.44


-
148 As in item 6 but for the lighter beams i.e. having spans upto 6 (D.S.R.-5.3) -
m. (Using M-20Mix concrete).
(a) Ground Floor 3.56 CUM 7958.63 28,335.92
-
149 Providing and laying in position specified grade of reinforced (D.S.R.-5.1.2) -
cement concrete, excluding the cost of centering, shuttering,
finishing and reinforcement - All work up to plinth level :

4.04 CUM 6257.17 25,278.95


-
150 As in item 6 above but in R.C.C. columns(Using M-20 Mix (D.S.R.-5.2.2) -
concrete).
(a) Ground Floor 2.41 CUM 7507.25 18,107.49
-
151 Brick work with common burnt clay F.P.S. (non modular) bricks (D.S.R.-6..2) 0.50 CUM 4933.55 2,450.99
of class designation 7.5 in foundation and plinth in:
-
152 Brick work with common burnt clay F.P.S. (non modular) bricks (D.S.R.-6.4.2) -
of class designation 7.5 in superstructure above plinth level up
to floor V level in all shapes and sizes in :
(a) Ground Floor 6.29 CUM 6298.81 39,602.08
-
153 Same as in item no. 14 but in 1:4 cement and coarse sand -
mortar in superstructure for wall thickness 12 cms & below
brick work.
(a) Ground Floor SQM -
-
154 P/F Mild steel or iron in plain work such as reinforced concrete D.S.R.-5.22.6 -
or reinforced, brick work (when not included in over all rates )
wrought to required shape as necessary including bending for
proper completion of the work and including supply of steel its
wastage bend hooks and authorised over lapping shall be
measured upto floor two level.

(a) Ground Floor 20.19 QTL 7460.25 1,50,604.54


-
155 15 mm plinth plaster (1 cement :4 coarse sand) D.S.R.-13.5.1 14.40 SQM 284.82 4,101.37
-
156 15 mm cement plaster in single coat on rough side of single or D.S.R.-13.5.2 -
half brick wall for interior plastering up to floor two level
including internal rounded angles not exceeding 80 mm in girth
and finshed even and smooth. (1) 1 cement : 6 coarse sand

(a) Ground Floor 30.96 SQM 273.47 8,466.73


-
157 12mm cement plaster in single coat on fair side of single or half D.S.R.-13.1.2 -
brick wall for exterior plastering up to floor two level including
internal rounded angles chamfers, and/or rounded angles not
exceeding 80mm in girth and finished even and smooth no
extra for mixing any additive. (1)1 cement : 6 coarse sand.

(a) Ground Floor 18.38 SQM 230.59 4,238.18


-
158 12mm thick plaster in 1:3 on ceiling and soffits of stairs upto -
floor two level.
(a) Ground Floor D.S.R.-13.7.1 18.48 SQM 303.84 5,614.96
-
159 Providing and fixing 18 mm thick gang saw cut, mirror D.S.R. 8.2.2.2 -
polished,premoulded and prepolished, machine cut for kitchen
platforms, vanitycounters, window sills , facias and similar
locations of required size, approved shade, colour and texture
laid over 20 mm thick base cementmortar 1:4 (1 cement : 4
coarse sand), joints treated with white cement,mixed with
matching pigment, epoxy touch ups, including rubbing,
curing,moulding and polishing to edges to give high gloss finish
etc. complete at all levels.Granite stone slab of colour black,
Cherry/Ruby red
(a) Ground Floor 29.02 SQM 3552.90 1,03,091.05
-
160 Providing and fixing 18 mm thick gang saw cut, mirror PWD-8.2.2.2 -
polished,premoulded and prepolished, machine cut for kitchen
platforms, vanitycounters, window sills , facias and similar
locations of required size,
approved shade, colour and texture laid over 20 mm thick base
cementmortar 1:4 (1 cement : 4 coarse sand), joints treated
with white cement,mixed with matching pigment, epoxy touch
ups, including rubbing, curing,moulding and polishing to edges
to give high gloss finish etc. complete at all levels.Granite stone
slab of colour black, Cherry/Ruby red
(a) Ground Floor 35.33 SQM 3552.90 1,25,516.98
-
161 Painting with silicon & acrylic emulsion based water thinnable D.S.R.-13.51.2 -
sealer of approved brand and manufacture on wet or patchy
portion of plastered
surfaces :
(a) Ground Floor SQM 111.85 -
-
162 Finishing walls with Acrylic smooth exterior paint of required D.S.R.-13.47.1 -
shade: - New work (Two or more coat applied @ 1.67 Ltr./10
Sqm over and including base coat of water proofing cement
paint applied @ 2.20 kg/10 Sqm.
(a) Ground Floor 18.38 SQM 118.35 2,175.35
-
163 Wall Painting with plastic emulsion paint of approved brand and D.S.R.-13.51.2 -
manufacture to give an even shade. Two or more coats (For
Internal ceiling surface)
(a) Ground Floor 18.48 SQM 111.85 2,067.02
-
164 Providing and applying white cement based putty of average D.S.R.-13.80 -
thickness 1 mm, of approved brand and manufacturer, over the
plastered wall surface to prepare the surface even and smooth
complete.
(a) Ground Floor 36.86 SQM 107.94 3,978.80
-
165 Providing and laying integral cement based water proofing -
treatment including preparation of surface as required for
treatment of roofs, balconies, terraces etc consisting of
following operations: a) Applying a slurry coat of neat cement
using 2.75 kg/sqm of cement admixed with water proofing
compound conforming to IS. 2645 and approved by Engineer-in-
charge over the RCC slab including adjoining walls upto 300 mm
height including cleaning the surface before treatment. b)
Laying brick bats with mortar using broken bricks/brick bats 25
mm to 115 mm size with 50% of cement mortar 1:5 (1 cement :
5 coarse sand) admixed with water proofing compound
conforming to IS : 2645 and approved by Engineer-in-charge
over 20 mm thick layer of cement mortar of mix 1:5 (1 cement
:5 coarse sand ) admixed with water proofing compound
conforming to IS : 2645 and approved by Engineer-in-charge to
required slope and treating similarly the adjoining walls upto
300 mm height including rounding of junctions of walls and
slabs c) After two days of proper curing applying a second coat
of cement slurry using 2.75 kg/ sqm of cement admixed
jointless cement mortar of mix 1:4 (1 cement :4 coarse sand)
admixed with water proofing compound conforming to IS : 2645
and approved by Engineer-in-charge including laying glass fibre
cloth of approved quality in top layer of plaster and finally
finishing the surface with trowel with neat cement slurry and
making pattern of 300x300 mm square
3 mm deep. e) The whole terrace so finished shall be flooded
with water for
a minimum period of two weeks for curing and for final test. All
above
DSR 22.7.1 18.48 SQM 1165.28 21,534.35
-
166 Stone work in plain ashlar in super structure upto floor five level D.S.R.-7.12.2.1 0.45 CUM 63150.97 28,583.71
in cement mortar 1:6 (1 cement : 6 coarse sand) including
pointing with cement mortar 1:2 (1 white cement : 2 stone
dust) with an admixture of pigment matching the stone shade
:Both face dressed.Red sand stone
-
167 Providing and fixing stone jali 40 mm thick throughout in D.S.R.-7.33.1.1 9.46 SQM 10328.52 97,707.76
cement mortar 1:3 (1 cement : 3 coarse sand), including
pointing in white cement mortar 1:2 (1 white cement : 2 stone
dust) with an admixture of pigment, matching the stone shade,
jali slab without any chamfers etc.Red sand stone

-
168 ADD FOR INTERNAL ELECTRIFICATION LS 2.00 Job 28500.00 57,000.00

169 Earth work in exacavation in t. in ordinary soil(loan clay or sand) 59.70 CUM 180.06 10,749.33
including lift upto 1.5 m and dressing of sides and ramming of
bottom sand disposal of surplus excavated earth as directed by
the Engineer i/c with in alead of 50m.
-
170 Providing and laying in cement concrete 1:4:8 (1 cement :4 -
coarse sand :8 graded stone aggregate 40 mm nominal size) and
curing complete, including cost of form- work, in foundation
and floors.
171.58 CUM 4712.03 8,08,499.88
-
171 Class M-150 brick work in 1:4 cement coarse sand (of 2.5 -
fineness modulus) mortar in foundation & plinth including
supply of all materials, labour, tools and plants etc. required for
proper completion of the work.
30.51 CUM 5098.46 1,55,570.94
-
172 Providing and laying 60mm thick faciory made cement concrete 893.29 SQM 672.36 6,00,608.16
interlocking paver block of M -30 grade made by block making
machine with strong vibratory compaction, of approved size,
design & shape, laid in required colour and pattern over and
including 50mm thick compacted bed of coarse sand, filling the
joints with line sand etc. all complete as per the direction of
Engineer-in-charge.

Cost of Lighiting Work (Solar) 8.00 NOS. 20045.00 1,60,360.00


173 Earth work in excavation by mechanical means (Hydraulic 2.59 CUM 180.06 466.70
excavator)/manual means over areas (exceeding 30 cm in
depth, 1.5 m in width as well as 10 sqm on plan) including
getting out and disposal of excavated earth lead upto 50 m and
lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil

-
174 Providing and laying in position cement concrete of specified 0.65 CUM 4712.03 3,053.39
gradeexcluding the cost of centering and shuttering - All work
up to plinthlevel :1:4:8 (1 Cement : 4 coarse sand : 8 graded
stone aggregate 40mm nominal size)
-
175 R.C.C. work with cement approved coarse sand and 2 cm. guage -
approved stone grit in the proportion of 1:1.5:3 in lintels of
doors and windows excluding supply of reinforcement and its
fixing and binding the same with 24 BWG binding wire and
including necessary centering and shuttering etc.and also
including supply of all materials, labour and tools and plants etc,
required for proper completion of the works. including cost of
binding wire. The rate excludes making of drip course which
shall be paid extra.
(a) Ground Floor CUM 7958.63 -
-
176 As in item 3 above but in R.C.C. Raft foundation and footing 1.16 CUM 6257.17 7,264.57
with approved stone ballast.(Using 1:1.5:3 Mix concrete)

-
177 First Class brick work in 1:6 cement and coarse sand of 1.25 2.40 CUM 4934.03 11,847.60
F.M. mortar in foundation and plinth including supply of all
materials, labour, tools and plants etc. required for proper
completion of the work. (1:6 cement & coarse sand)
-
178 P/F Mild steel or iron in plain work such as reinforced concrete -
or reinforced, brick work (when not included in over all rates )
wrought to required shape as necessary including bending for
proper completion of the work and including supply of steel its
wastage bend hooks and authorised over lapping shall be
measured upto floor two level.

0.91 QTL 7460.25 6,799.16


-
179 Stone work (machine cut edges) for wall lining etc. (veneer 22.18 SQM 3663.30 81,237.40
work) upto 10 metre height, backing filled with a grout of
average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse
sand) including pointing in white cement mortar 1:2 (1 white
cement : 2 stone dust) with an admixture of pigment matching
the stone shade : (To be secured to the backing and the sides by
means of cramps and pins which shall be paid for separately)
:Stone work (machine cut edges) for wall lining etc. (veneer
work) upto 10 metre height, backing filled with a grout of
average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse
sand) including pointing in white cement mortar 1:2 (1 white
cement : 2 stone dust) with an admixture of pigment matching
the stone shade : (To be secured to the backing and the sides by
means of cramps and pins which shall be paid for separately)
:Red sand stone - exposed face fine dressed with rough
backing.30 mm thick
-
a Providing and fixing stainless steel cramps of required size and 22.18 KG 494.17 10,958.67
shape for anchoring stone wall lining to the backing or securing
adjacent stones in stone wall lining in cement mortar 1:2 (1
cement : 2 coarse sand), including making the necessary chases
in stone and holes in walls wherever required.

-
b Providing and fixing copper pins 7.5 cm long 6 mm diameter for 90.00 NOS. 30.37 2,733.00
securing adjacent stones in stone wall lining in cement mortar
1:2 (1 cement : 2 coarse sand), including making the necessary
chases.

180 Supplying and stacking sludge at site including royalty and (DSR-2.3) 148.58 CUM 266.45 39,590.53
carriage up to 5 km (sludge measured in stacks will be reduced
by 8% for payment).
-
181 Carrigae of sludge upto 5 K.M. (DSR-1.1.3) 148.58 CUM 169.97 25,254.45
-
182 Supplying and stacking at site dump manure from approved (DSR-2.4.3) 49.53 CUM 289.93 14,359.42
source including carriage upto 1 km (manure measured in
stacks will be reduced by 8% for payment) : Screened through
sieve of I.S. designation 4.75 mm
-
183 Carrigae of manure upto 5 K.M. (DSR-1.1.3) 49.53 CUM 169.97 8,418.15
-
184 Mixing earth and sludge or manure in the required proportion (DSR-2.9) 198.11 CUM 33.13 6,562.51
specified or directed by the Officer-in-charge.
-
185 Spreading of sludge, dump manure or/and good earth in (DSR-2.8) 198.11 CUM 47.44 9,399.39
required thickness (cost of sludge dump manure or/and good
earth to be paid separately).
-
186 Digging holes in ordinary soil and refilling the same with the -
excavated earth mixed with manure or sludge in the ratio of 2:1
by volume (2 parts of stacked volume of earth after reduction
by 20% : 1 part of stacked volume of manure after reduction by
8%), flooding with water, dressing, including removal of rubbish
and surplus earth, if any with all leads and lifts ( cost of manure,
sludge or extra good earth if needed to be paid for separately).

Holes 0.9 m dia. and 0.90 m deep. (DSR-2.14.2) 75.00 NO. 129.69 9,726.86
-
187 Plantation of Trees, Shrubs, and Hedge at site i/c watering and (DSR-2.57.1) 50.00 NOS. 6.62 330.80
removal of unserveiceable material’s as per direction of officer
in charge (excluding cast of plant & water).Trees Plant

(i) Providing and stacking of Bottle palm of ht. 210-240 cm bottom (DSR-7.11) 15.00 NOS. 317.21 4,758.08
girth 30-35 cm well developed in big HDPE bags.
(ii) Providing and stacking of Bottle palm of ht. 270-300 cm bottom (DSR-7.12) 25.00 NOS. 498.47 12,461.63
girth 40-50 cm well developed in big HDPE bags as per direction
of the officer-in-charge
(iii) Providing and stacking of Foxtail palm of ht. 180-210 cm bottom (DSR-7.43) 15.00 NOS. 435.02 6,525.36
girth 25- 30 cm well developed in big size HDPE bags as per
direction of the officer-in-charge.
(iv) Providing and stacking of Michelia champa (Golden Champa) of (DSR-7.55) 20.00 NOS. 81.57 1,631.34
height 90- 105 cm. in earthen pots of size 25 cm as per direction
of the officer-in-charge.
-
188 Grassing with selection No.1 grass including watering and (DSR-2.10.2) 990.56 Sqm 12.05 11,940.00
maintenance of the lawn for 30 days or more till the grass forms
a thick lawn, free from weeds and fit for mowing including
supplying good earth, if needed (the good earth shall be paid
for separately). With grass Turf.
-
189 Providing and fixing M.S. flat iron tree guard 60 cm dia and 2 m (DSR-2.16) 75.00 Each 4108.35 3,08,126.14
high, above ground consisting 4 nos 25 x 6 mm, 2.25 m long and
8 nos 25 x 3 mm 2 m long verticals M.S. flats, riveted to 3 nos 25
x 6 mm M.S. flat iron rings in two halves, fixing together at site
with required six numbers of 8 mm dia. and 30 mm long bolts,
including painting two coats with synthetic enamel paint of
approved brand and manufacture over a coat of primer. One
name plate of 1 mm thick M.S. sheet of size 250x100 mm shall
be welded to the treeguard near the middle height and lettered
CPWD / PWD/ any other approved name. The tree guard shall
be suitably fixed to the ground by embedding four legs of tree
guard in pits of suitable dia and to a depth of 25 cm, refilling the
pits with soil and ramming, complete in all respect as per
satisfaction and direction of Officer-in-charge.

190 Earth work in excavation by mechanical means (Hydraulic D.S.R.-2.8.1 1.64 CUM 180.06 295.34
excavator)/manual means over areas (exceeding 30 cm in
depth, 1.5 m in width as well as 10 sqm on plan) including
getting out and disposal of excavated earth lead upto 50 m and
lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil

-
191 Providing and laying cement concrete 1:4:8 (1 cement :4 coarse (D.S.R.-4.1.8) 0.27 CUM 4712.03 1,288.15
sand :8 graded Stone aggregate 40 mm nominal size) including
supply of all materials, labour T & P rtc required for proper
completion of the work and curing complete also including cost
of formwork in foundation & floors.
-
192 Reinforced cement concrete work in beams, suspended floors, (D.S.R.-5.3) -
roofs having slope up to 15° landings, balconies, shelves,
chajjas, lintels,
bands, plain window sills, staircases and spiral stair cases above
plinth level up to floor five level, excluding the cost of centering,
shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :
1.5 coarse sand(zone-III) derived from natural sources : 3
graded stone aggregate 20 mm nominal size derived from
natural sources). Beam
(a) Ground Floor CUM 7958.63 -
-
193 Providing and laying in position specified grade of reinforced -
cement concrete, excluding the cost of centering, shuttering,
finishing and
reinforcement - All work up to plinth level :
1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from (D.S.R.-5.1.2) 0.29 CUM 6257.17 1,802.06
natural sources : 3 graded stone aggregate 20 mm nominal size
de rived from natural sources)
-
194 Brick work with common burnt clay F.P.S. (non modular) bricks (D.S.R.-6.1.2) 1.09 CUM 4934.03 5,395.37
of class designation 7.5 in foundation and plinth in:Cement
mortar 1:6 (1 cement : 6 coarse sand)
-
195 Steel reinforcement for R.C.C. work including straightening, (D.S.R.-5.22.6) -
cutting, bending, placing in position and binding all complete
upto plinth level.Thermo-Mechanically Treated bars of grade Fe-
500D or more.
0.23 QTL 7460.25 1,686.61
-
196 Stone work (machine cut edges) for wall lining etc. (veneer D.S.R.-8.14.1.5 4.09 SQM 3663.30 14,965.51
work) upto 10 metre height, backing filled with a grout of
average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse
sand) including pointing in white cement mortar 1:2 (1 white
cement : 2 stone dust) with an admixture of pigment matching
the stone shade : (To be secured to the backing and the sides by
means of cramps and pins which shall be paid for separately)
:Stone work (machine cut edges) for wall lining etc. (veneer
work) upto 10 metre height, backing filled with a grout of
average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse
sand) including pointing in white cement mortar 1:2 (1 white
cement : 2 stone dust) with an admixture of pigment matching
the stone shade : (To be secured to the backing and the sides by
means of cramps and pins which shall be paid for separately)
:Red sand stone - exposed face fine dressed with rough
backing.30 mm thick
-
a Providing and fixing stainless steel cramps of required size and D.S.R.-8.15 4.09 KG 494.17 2,018.80
shape for anchoring stone wall lining to the backing or securing
adjacent stones in stone wall lining in cement mortar 1:2 (1
cement : 2 coarse sand), including making the necessary chases
in stone and holes in walls wherever required.

-
b Providing and fixing copper pins 7.5 cm long 6 mm diameter for D.S.R.-8.16 16.00 NOS. 30.37 485.87
securing adjacent stones in stone wall lining in cement mortar
1:2 (1 cement : 2 coarse sand), including making the necessary
chases.
-
197 Providing and fixing 18 mm thick gang saw cut, mirror polished, D.S.R.-8.2.2.2 0.90 SQM 3552.90 3,197.61
premoulded and prepolished, machine cut for kitchen
platforms, vanity counters, window sills, facias and similar
locations of required size, approved shade, colour and texture
laid over 20 mm thick base cement mortar 1:4 (1 cement : 4
coarse sand), joints treated with white cement, mixed with
matching pigment, epoxy touch ups, including rubbing, curing,
moulding and polishing of edges to give high gloss finish etc.
complete
at all levels.Granite stone slab of colour black, Cherry/Ruby
red.Area of slab over 0.50 sqm
-
198 Cost of Stone writing MR 0.45 SQM 25555.00 11,499.75
-
199 Supply and fixing of decorative 8 to 16 Watt LED bollard UPPWD 2.00 NOS. 2815.32 5,630.64
luminaire with driver set confirming to IP 65 protection ELECTRICAL 2018
complete in all respect.Cat- AAA ITEM NO. 1442
-
200 Supply and fixing of factory wired integral LED flood light UPPWD 2.00 NOS. 3147.35 6,294.69
luminaires with die cast aluminium housing built with driver set ELECTRICAL 2018
suitbale for 40 to 50 Watt Conforming to IP 65/66 protection ITEM NO. 1451
complete in all respect.(CAT-AAA)

201 External W/S arrangement, T.W. boring of 150mm dia with


100mm dia P.V.C. pipe assembly, 1.5 H.P. submersible pump
including supply of all accessories starter, panel etc. & pipe
arrangement etc.
a 4" PVC pipe of ISI mark [14 Kg pressure] 60 RM 760.00 45600.00
b P/F 2" GI pipe (B) class. 40 RM 332.50 13300.00
c NYLon mesh for filter 1 Roll 522.50 522.50
d Plastic dori 1 Gulla 142.50 142.50
e Solvent dori 1 L.t 237.50 237.50
f 4" End cap 1 NO. 237.50 237.50
g 4" Submersible Cap 1 No. 213.75 213.75
h 2" MS clamp (Heavy) 1 Pair 475.00 475.00
i 2" Gl elbow. 1 No. 104.50 104.50
j 2"*6" GI nipple 1 NO. 133.00 133.00
k 1.5 HP 9 Stage Submersible Pump of ISI mark With
l automatic panel. 1 NO. 23750.00 23750.00
m 2.5 Sqm. Submersible cable. 60 mt. 190.00 11400.00
n Drilling Charges for 6" dia tubewell. 60 mt. 261.25 15675.00
o Pea Gravel 1 Cm. 2850.00 2850.00
p 2" Ms Socket. 4 No. 142.50 570.00
q Cartage of material upto site. L.s 3800.00 3800.00
85,04,300.74