Control System Engineering ©Dept.

of ETE, CUET

CHITTAGONG UNIVERSITY OF ENGINEERING AND TECHNOLOGY


DEPARTMENT OF ELECTRONICS & TELECOMMUNICATION
ENGINEERING
CHITTAGONG-4349, BANGLADESH.

COURSE NO.: ETE 212

Experiment No. 4

Analysis of Bode plot Using MATLAB

PRELAB WORK:

 Read this laboratory manual carefully before coming to the


laboratory class, so that you know what is required.
 Try to follow the lecture notes of ETE 211.
 Familiarize yourself with relevant MATLAB functions and codes necessary for
this experiment.
 Do not bring any prepared MATLAB code in the lab with any portable device.
 DONOT copy others blindly!!!
 Submit your lab report before the roll call.

INTRODUCTION:

The frequency response method may be less intuitive than other methods you have studied
previously. However, it has certain advantages, especially in real-life situations such as
modeling transfer functions from physical data.

The frequency response of a system can be viewed two different ways: via the Bode plot or
via the Nyquist diagram. Both methods display the same information; the difference lies in
the way the information is presented. We will study both methods in this manual.

The frequency response is a representation of the system's response to sinusoidal inputs at


varying frequencies. The output of a linear system to a sinusoidal input is a sinusoid of the
same frequency but with a different magnitude and phase. The frequency response is
defined as the magnitude and phase differences between the input and output sinusoids. In
this manual, we will see how we can use the open-loop frequency response of a system to
predict its behavior in closed-loop.

To plot the frequency response, we create a vector of frequencies (varying between zero or
"DC" and infinity) and compute the value of the plant transfer function at those frequencies.
If G(s) is the open loop transfer function of a system and w is the frequency vector, we then
plot G(j*w) vs. w. Since G(j*w) is a complex number, we can plot both its magnitude and
phase (the Bode plot) or its position in the complex plane (the Nyquist plot). More
information is available on plotting the frequency response.
Control System Engineering ©Dept. of ETE, CUET

Key MATLAB commands used in this manual: bode, margin, lsim, step, and feedback

PART-1: BODE PLOTS

THEORY WITH EXAMPLES:

As noted above, a Bode plot is the representation of the magnitude and phase of G(j*w)
(where the frequency vector w contains only positive frequencies). To see the Bode plot of a
transfer function, you can use the MATLAB bode command. For example,

num = 50;
den = [1 9 30 40];
sys = tf(num,den);
bode(sys)

displays the Bode plots for the transfer function:

50
------------------------------
s^3 + 9 s^2 + 30 s + 40

Please note the axes of the figure. The frequency is on a logarithmic scale, the phase is given
in degrees, and the magnitude is given as the gain in decibels.

Note: a decibel is defined as 20*log10 ( |G(j*w| )

Gain and Phase Margin

Let's say that we have the following system:


Control System Engineering ©Dept. of ETE, CUET

where K is a variable (constant) gain and G(s) is the plant under consideration. The gain
margin is defined as the change in open loop gain required making the system unstable.
Systems with greater gain margins can withstand greater changes in system parameters before
becoming unstable in closed loop.

Keep in mind that unity gain in magnitude is equal to a gain of zero in dB.

The phase margin is defined as the change in open loop phase shift required making a closed
loop system unstable.

The phase margin also measures the system's tolerance to time delay. If there is a time delay
greater than 180/Wpc in the loop (where Wpc is the frequency where the phase shift is 180
deg), the system will become unstable in closed loop. The time delay can be thought of as an
extra block in the forward path of the block diagram that adds phase to the system but has no
effect the gain. That is, a time delay can be represented as a block with magnitude of 1 and
phase w*time_delay (in radians/second).

For now, we won't worry about where all this comes from and will concentrate on identifying
the gain and phase margins on a Bode plot.

The phase margin is the difference in phase between the phase curve and -180 deg at the
point corresponding to the frequency that gives us a gain of 0dB (the gain cross over
frequency, Wgc). Likewise, the gain margin is the difference between the magnitude curve
and 0dB at the point corresponding to the frequency that gives us a phase of -180 deg (the
phase cross over frequency, Wpc).

One nice thing about the phase margin is that you don't need to replot the Bode in order to
find the new phase margin when changing the gains. If you recall, adding gain only shifts the
magnitude plot up. This is the equivalent of changing the y-axis on the magnitude plot.
Control System Engineering ©Dept. of ETE, CUET

Finding the phase margin is simply the matter of finding the new cross-over frequency and
reading off the phase margin. For example, suppose you entered the command bode(sys).
You will get the following bode plot:

You should see that the phase margin is about 100 degrees. Now suppose you added a gain of
100, by entering the command bode(100*sys). You should get the following plot (note we
changed the axis so the scale would be the same as the plot above, your bode plot may not be
exactly the same shape, depending on the scale used):

As you can see the phase plot is exactly the same as before, and the magnitude plot is shifted
up by 40dB (gain of 100). The phase margin is now about -60 degrees. This same result could
be achieved if the y-axis of the magnitude plot was shifted down 40dB. Try this, look at the
first Bode plot, find where the curve crosses the -40dB line, and read off the phase margin. It
should be about -60 degrees, the same as the second Bode plot.

We can find the gain and phase margins for a system directly, by using MATLAB. Just use
the margin command. This command returns the gain and phase margins, the gain and phase
cross over frequencies, and a graphical representation of these on the Bode plot. Let's check it
out:
Control System Engineering ©Dept. of ETE, CUET

margin(sys)

Bandwidth Frequency

The bandwidth frequency is defined as the frequency at which the closed-loop magnitude
response is equal to -3 dB. However, when we design via frequency response, we are
interested in predicting the closed-loop behavior from the open-loop response. Therefore, we
will use a second-order system approximation and say that the bandwidth frequency equals
the frequency at which the open-loop magnitude response is between -6 and - 7.5dB,
assuming the open loop phase response is between -135 deg and -225 deg. For a complete
derivation of this approximation, consult your textbook.

If you would like to see how the bandwidth of a system can be found mathematically from
the closed-loop damping ratio and natural frequency, the relevant equations as well as some
plots and MATLAB code are given on our Bandwidth Frequency page.

In order to illustrate the importance of the bandwidth frequency, we will show how the output
changes with different input frequencies. We will find that sinusoidal inputs with frequency
less than Wbw (the bandwidth frequency) are tracked "reasonably well" by the system.
Sinusoidal inputs with frequency greater than Wbw are attenuated (in magnitude) by a factor
of 0.707 or greater (and are also shifted in phase).

Let's say that we have the following closed-loop transfer function representing a system:

1
--------------------
s^2 + 0.5 s + 1
First of all, let's find the bandwidth frequency by looking at the Bode plot:

num = 1;
den = [1 0.5 1];
Control System Engineering ©Dept. of ETE, CUET

sys = tf(num,den);
bode (sys)

Since this is the closed-loop transfer function, our bandwidth frequency will be the frequency
corresponding to a gain of -3 dB. looking at the plot, we find that it is approximately 1.4
rad/s. We can also read off the plot that for an input frequency of 0.3 radians, the output
sinusoid should have a magnitude about one and the phase should be shifted by perhaps a few
degrees (behind the input). For an input frequency of 3 rad/sec, the output magnitude should
be about -20dB (or 1/10 as large as the input) and the phase should be nearly -180 (almost
exactly out-of-phase). We can use the lsim command to simulate the response of the system
to sinusoidal inputs.

First, consider a sinusoidal input with a frequency lower than Wbw. We must also keep in
mind that we want to view the steady state response. Therefore, we will modify the axes in
order to see the steady state response clearly (ignoring the transient response).

w = 0.3;
num = 1;
den = [1 0.5 1];
sys = tf(num,den);
t = 0:0.1:100;
u = sin(w*t);
[y,t] = lsim(sys,u,t);
plot(t,y,t,u)
axis([50,100,-2,2])
Control System Engineering ©Dept. of ETE, CUET

Note that the output (blue) tracks the input (purple) fairly well; it is perhaps a few degrees
behind the input as expected.

However, if we set the frequency of the input higher than the bandwidth frequency for the
system, we get a very distorted response (with respect to the input):

w = 3;
num = 1;
den = [1 0.5 1];
sys = tf(num,den);
t = 0:0.1:100;
u = sin(w*t);
[y,t] = lsim(sys,u,t);
plot(t,y,t,u)
axis([90, 100, -1, 1])

Again, note that the magnitude is about 1/10 that of the input, as predicted, and that it is
almost exactly out of phase (180 degrees behind) the input. Feel free to manual and view the
response for several different frequencies w, and see if they match the Bode plot.

Closed-loop performance

In order to predict closed-loop performance from open-loop frequency response, we need to


have several concepts clear:

 The system must be stable in open loop if we are going to design via Bode plots.
 If the gain cross over frequency is less than the phase cross over frequency (i.e. Wgc
< Wpc), then the closed-loop system will be stable.
 For second-order systems, the closed-loop damping ratio is approximately equal to the
phase margin divided by 100 if the phase margin is between 0 and 60 deg. We can use
this concept with caution if the phase margin is greater than 60 deg.
 For second-order systems, a relationship between damping ratio, bandwidth frequency
and settling time is given by an equation described on the bandwidth page.
 A very rough estimate that you can use is that the bandwidth is approximately equal
to the natural frequency.

Let's use these concepts to design a controller for the following system:
Control System Engineering ©Dept. of ETE, CUET

Where Gc(s) is the controller and G(s) is:

10
--------------
1.25s + 1

The design must meet the following specifications:

 Zero steady state error.


 Maximum overshoot must be less than 40%.
 Settling time must be less than 2 secs.

There are two ways of solving this problem: one is graphical and the other is numerical.
Within MATLAB, the graphical approach is best, so that is the approach we will use. First,
let's look at the Bode plot. Create an m-file with the following code:
num = 10;
den = [1.25,1];
sys = tf(num,den);
bode(sys)

There are several several characteristics of the system that can be read directly from this
Bode plot. First of all, we can see that the bandwidth frequency is around 10 rad/sec. Since
the bandwidth frequency is roughly the same as the natural frequency (for a first order system
of this type), the rise time is 1.8/BW=1.8/10=1.8 seconds. This is a rough estimate, so we will
say the rise time is about 2 seconds.

The phase margin for this system is approximately 95 degrees. The relation damping ratio =
pm/100 only holds for PM < 60/ Since the system is first-order, there should be no overshoot.

The last major point of interest is steady-state error. The steady-state error can be read
directly off the Bode plot as well. The constant (Kp, Kv, or Ka) is found from the intersection
of the low frequency asymptote with the w=1 line. Just extend the low frequency line to the
w=1 line. The magnitude at this point is the constant. Since the Bode plot of this system is a
horizontal line at low frequencies (slope = 0), we know this system is of type zero. Therefore,
the intersection is easy to find. The gain is 20dB (magnitude 10). What this means is that the
Control System Engineering ©Dept. of ETE, CUET

constant for the error function it 10. The steady-state error is 1/(1+Kp)=1/(1+10)=0.091. If
our system was type one instead of type zero, the constant for the steady-state error would be
found in a manner similar to the following

Let's check our predictions by looking at a step response plot. This can be done by adding the
following two lines of code into the MATLAB command window.

sys_cl = feedback(sys,1);
step(sys_cl)

As you can see, our predictions were very good. The system has a rise time of about 2
seconds, has no overshoot, and has a steady-state error of about 9%. Now we need to choose
a controller that will allow us to meet the design criteria. We choose a PI controller because it
will yield zero steady state error for a step input. Also, the PI controller has a zero, which we
can place. This gives us additional design flexibility to help us meet our criteria. Recall that a
PI controller is given by:

K*(s+a)
Gc(s) = -----------
s

The first thing we need to find is the damping ratio corresponding to a percent overshoot of
40%. Plugging in this value into the equation relating overshoot and damping ratio (or
consulting a plot of this relation), we find that the damping ratio corresponding to this
overshoot is approximately 0.28. Therefore, our phase margin should be at least 30 degrees.
Control System Engineering ©Dept. of ETE, CUET

From our Ts*Wbw vs damping ratio plot, we find that Ts*Wbw ~ 21. We must have a
bandwidth frequency greater than or equal to 12 if we want our settling time to be less than
1.75 seconds which meets the design specs.

Now that we know our desired phase margin and bandwidth frequency, we can start our
design. Remember that we are looking at the open-loop Bode plots. Therefore, our bandwidth
frequency will be the frequency corresponding to a gain of approximately -7 dB.

Let's see how the integrator portion of the PI or affects our response. Change your m-file to
look like the following (this adds an integral term but no proportional term):

num = 10;
den = [1.25 1];
plant = tf(num,den);
numPI = 1;
denPI = [1 0];
contr = tf(numPI,denPI);
bode(contr * plant, logspace(0,2))

Our phase margin and bandwidth frequency are too small. We will add gain and phase with a
zero. Let's place the zero at 1 for now and see what happens. Change your m-file to look like
the following:

num = 10;
den = [1.25 1];
plant = tf(num,den);
numPI = [1 1];
denPI = [1 0];
contr = tf(numPI,denPI);
bode(contr * plant, logspace(0,2))
Control System Engineering ©Dept. of ETE, CUET

It turns out that the zero at 1 with a unit gain gives us a satisfactory answer. Our phase margin
is greater than 60 degrees (even less overshoot than expected) and our bandwidth frequency
is approximately 11 rad/s, which will give us a satisfactory response. Although satisfactory,
the response is not quite as good as we would like. Therefore, let's try to get a higher
bandwidth frequency without changing the phase margin too much. Let's try to increase the
gain to 5 and see what happens. This will make the gain shift and the phase will remain the
same.

num = 10;
den = [1.25 1];
plant = tf(num,den);
numPI = 5*[1 1];
denPI = [1 0];
contr = tf(numPI,denPI);
bode(contr * plant, logspace(0,2))

That looks really good. Let's look at our step response and verify our results. Add the
following two lines to your m-file:
Control System Engineering ©Dept. of ETE, CUET

sys_cl = feedback(contr * plant,1);


step(sys_cl)

As you can see, our response is better than we had hoped for. However, we are not always
quite as lucky and usually have to play around with the gain and the position of the poles
and/or zeros in order to achieve our design requirements.

Home Task

The open-loop transfer function for this problem is:

 m=1000
 b=50
 U(s)=10
 Y(s)=Velocity output

The design criteria are:

Rise time < 5 sec


Overshoot < 10%
Steady state error < 2%

The requirements are -

1. To find out the open-loop response and using a proportional controller find out the
rise time, damping ratio and steady-state error.
Control System Engineering ©Dept. of ETE, CUET

2. Finding out the closed-loop response.


3. Find out the value of Kp to keep the steady-state error to the desired level.
4. Discuss about the problem for a very high value of Kp to make the steady-state error
low.
5. Now use a lag controller to improve the condition.