QTN 2324 10268

Download as pdf or txt
Download as pdf or txt
You are on page 1of 20

Indian Oil Corporation Ltd - Haldia (Wb)

Haldia Oil Refinery


Quotation
Dist. Purba Midnapur QTN/2324/10268
Haldia, West Bengal -721605 Date: 09-09-2023
GSTIN: 19AAACI1681G1ZM Quote Expires: 08-10-2023

Attn Mobile Email Inquiry / Tender No. Due Date


Mr Prashant Kumar Jha 7463842346 [email protected] Email - for Bitumen Testing
Equipments
Our Techno-Commercial Person Email Id Contact No.
Parixit Hasmukhbhai Patel [email protected] 9106703966
Dear Sir/Madam,
We thank you for your enquiry and have pleasure in giving our offer as per terms & conditions here under.
Please scroll down up to the last page to view the detailed specifications and photo/images of the offered instruments.
Sr. Description Qty Rate Final Amount
No
1 DETERMINATION OF PENETRATION 1.0 Nos ₹ 1,19,905.00 ₹ 1,19,905.00
Model No. : TM-044ATGB HSN : 90248099
As per IS 1203, IS 1448. ASTM D5. In addition to regular features, this model is
Fitted with Micrometer differential gearing system for fine movement of
penetration needle. Complete with Automatic Timer, Penetration cup and
transfer dish.

Item Included
1. LOW TEMPERATURE WATERBATH - 5 LITERS CAPACITY
QTY : 1.0
HSN : 84198990
2. NEEDLE FOR STANDARD PENETROMETER-ASTM D5
QTY : 3.0
HSN : 90278090
3. GLASS THERMOMETER 0° / 44°C X 0.2°C
QTY : 3.0
HSN : 90251190
4. STOP WATCH - DIGITAL
QTY : 1.0
HSN : 91029120
5. PENETRATION CUP-55 X 35 MM-ALUMINIUM-FOR STANDARD
PENETROMETER-ASTM D5
QTY : 50.0
HSN : 90249000
2 APPARATUS FOR SOLUBILITY IN TRI-CHLORO ETHYLENE-IS 1216 - 1.0 Nos ₹ 48,400.00 ₹ 48,400.00
METHOD A (FOR ASPHALTIC BITUMEN)
Model No. : EIE-BT-108-A HSN : 70179090
Apparatus for Solubility in Tri-chloro Ethylene as per IS 1216 consists of Gooch
crucible - 5 nos., a Conical flask 500 ml - 5 nos.. capacity. supplied with vacuum
pump for Filtration.

Item Included
1. GOOCH CRUCIBLE GLASS - G-4 50 ML.
QTY : 5.0
HSN : 70171000
2. FLASK CONICAL - BOROSILICATE - 500ML
QTY : 5.0
HSN : 70179090
3 DETERMINATION OF DUCTILITY 1.0 Nos ₹ 2,62,335.00 ₹ 2,62,335.00
Model No. : TM-40RSA HSN : 90249000
Compliance with Following International Standards As per IS : 1208, ASTM
D113.Detailed Specification as follows.

Item Included
1. DUCTILITY MOULD - BRASS WITH BASE PLATE - PRICE PER MOULD
QTY : 2.0
HSN : 90249000
2. MOULD CASTING PLATE FOR DUCTILITY TEST
QTY : 3.0
HSN : 90249000
3. GLASS THERMOMETER 0° / 44°C X 0.2°C - FOR DUCTILITY TESTING
OF BITUMEN AS PER IS:1208
QTY : 3.0
HSN : 90251190
4 DETERMINATION OF SOFTENING POINT 1.0 Nos ₹ 39,760.00 ₹ 39,760.00
Model No. : TM-043PD HSN : 90248099
Also called Softening Point Apparatus. This apparatus is meant for
determination o f softening point of bituminous materials according to listed
ASTM & IP Standards. Compliance with Following International Standards EN
1427 | ASTM D36 | AASHTO T53 | IP 58 | IS 1205. In addition to regular
accessories, a Digital Programmable temp.controller is fitted to the unit to
ensure rise of temperature at 5° C as per the guidelines of
ASTM/ISO/AASTHO/IS Standards. FULLY Automatic Model also available for
Research application. Detailed specification as follows:

Item Included
1. GLASS THERMOMETER - (-2/80°C X 0.2°C) FOR SOFTENING POINT -
ASTM 15C / IP 60C
QTY : 3.0
HSN : 90251190
2. GLASS THERMOMETER - (30°C/200°C X 0.5°C) FOR SOFTENING POINT
- ASTM 16C/IP 61C
QTY : 3.0
HSN : 90251190
5 ABSOLUTE VISCOSITY BATH FOR 2 VISCOMETER - FOR BITUMEN 60C 1.0 Nos ₹ 3,27,850.00 ₹ 3,27,850.00
HSN : 90278010
Used for determination of absolute viscosity of VG Grade Bitumen in
Accordance with IS:1206 (Part 2). Double walled, outer chamber made of CRC
powder coated with toughened Glass window panel, inner chamber made of
S.S, FHP motorized stirrer for uniform Temperature, Dual Display
Microprocessor Based Digital Temp. Controller with PT–100 sensor.Temperature
range from 5° C above ambient to 100° C. Control Accuracy ± 0.1°C (at 60°C).
Complete with Low wattage lighting Attachment, Universal Viscometer Holder,
Viscometer Tray and Calibration certificate with traceability. Working on 230 V
single phase. Indian Make U Tube Vacuum Manning Viscometer size No.12 and
13 with certificate of constant (1 No.each size), Oil Free Vacuum Pump to
control vacuum @ 30 cm/Hg and Silicon tube are supplied as standard
accessories

Item Included
1. U TUBE GLASS VISCOMETER CANNON MANNING VACUUM INDIAN
MAKE - SIZE NO. 12
QTY : 3.0
HSN : 90278010
2. U TUBE GLASS VISCOMETER CANNON MANNING VACUUM INDIAN
MAKE - SIZE NO. 13
QTY : 3.0
HSN : 90278010
3. CALIBRATION OF U-TUBE VISCOMETER - SIZE -12 -NABL
QTY : 3.0
HSN : 998346
4. CALIBRATION OF U-TUBE VISCOMETER - SIZE -13 -NABL
QTY : 3.0
HSN : 998346
5. STOP WATCH FOR K.V BATH
QTY : 1.0
HSN : 85429000
6. DIGITAL VACUUM REGULATOR FOR KINEMATIC VISCOSITY BATH-FOR
4 VISCOMETERS-WITHOUT VACUUM PUMP-
QTY : 1.0
HSN : 90278010
7. GLASS THERMOMETER 37.8C - 80C x 0.2C
QTY : 2.0
HSN : 90251190
6 KINEMATIC VISCOSITY BATH FOR BITUMEN - @ 135°C 1.0 Nos ₹ 1,52,605.00 ₹ 1,52,605.00
HSN : 9027
As per IS: 1206 (Part III). Supplied complete with Viscosity bath for 2 viscometer
tube with built in Digital stop watch, Viscometer, Silicon oil, silicon tubes and
calibration certificate for Viscosity bath, certificate of constant for Viscometers.
Complete with instruction manual. Detailed Specification as mentioned in
technical part mentioned below.

Item Included
1. U TUBE GLASS VISCOMETER MODIFIED REVERSE FLOW SIZE NO. 6
QTY : 4.0
HSN : 90278010
2. U TUBE GLASS VISCOMETER MODIFIED REVERSE FLOW SIZE NO. 7
QTY : 2.0
HSN : 70179090
3. CALIBRATION OF U-TUBE VISCOMETER - NABL
QTY : 6.0
HSN : 998346
4. STOP WATCH FOR K.V BATH
QTY : 1.0
HSN : 85429000
5. SILICON OIL
QTY : 20.0
HSN : 27101990
6. GLASS THERMOMETER - (133.6° TO 136.4°C X 0.05°C )- FOR
KINEMATIC VISCOSITY BATH FOR BITUMEN - ASTM 110 C /IP 93 C
QTY : 3.0
HSN : 90251190
7 ROLLING THIN FILM OVEN 1.0 Nos ₹ 2,17,550.00 ₹ 2,17,550.00
Model No. : EIE-107-RT HSN : 85141000
As per ASTM D2872, AASHTO T240, CNR N.54, EN 12607-1, IS 15799-2008.
For Residue Test - Dynamic Shear Rheometer, Pressure Ageing Vessel and
Vacuum Degassing oven are Mandatory and it's available at extra cost.

Item Included
1. GLASS THERMOMETER (-155/170 C X 0.5 C)-(FOR LOSS ON HEATING)-
(ASTM 13C, IP 47C) WITH CALIBRATION
QTY : 3.0
HSN : 90251190
8 CLEAVELAND FLASH POINT APPARATUS -WITH DIGITAL TEMPERATURE 1.0 Nos ₹ 21,800.00 ₹ 21,800.00
INDICATOR
Model No. : EIE-PTLT-102DM HSN : 90278090
This apparatus is used for determination of flash point and fire point of petroleum
products open cup flash above 80°C as per specification IP 36 and IS: 1448 (P:
69) 1969. The apparatus consists of a cup, heating plate to specific dimension
thermometer clip and test flame attachment with swivel joint for passing over test
liquid surface in the prescribed manner, Heating is controlled by means of
energy regulator fitted to the apparatus. Suitable for operation on 220 Volts 50
cycles AC Circuits. With Digital Temperature Indicator along with Combined wick
system arrangement. (Either by Gas jet or by Oil wick arrangement). Supplied
with GLASS THERMOMETER - -6°C TO 400°C x 2°C-FOR CLEAVELAND
APP-ASTM 11C, IP 28C - 3 nos.

Item Included
1. GLASS THERMOMETER - (-6°C / 400°C X 2°C)-FOR CLEAVELAND APP-
ASTM 11C / IP 28C
QTY : 3.0
HSN : 90251190
HSN/SAC Taxable Amount IGST
90248099 ₹ 62,185.00 (18.0%) ₹ 11,193.30
84198990 ₹ 58,500.00 (18.0%) ₹ 10,530.00
90278090 ₹ 19,955.00 (18.0%) ₹ 3,591.90
90251190 ₹ 30,750.00 (18.0%) ₹ 5,535.00
91029120 ₹ 575.00 (18.0%) ₹ 103.50
90249000 ₹ 2,83,835.00 (18.0%) ₹ 51,090.30
70179090 ₹ 57,625.00 (18.0%) ₹ 10,372.50
70171000 ₹ 1,525.00 (18.0%) ₹ 274.50
90278010 ₹ 2,94,970.00 (18.0%) ₹ 53,094.60
998346 ₹ 96,000.00 (18.0%) ₹ 17,280.00
85429000 ₹ 6,160.00 (18.0%) ₹ 1,108.80
9027 ₹ 48,125.00 (18.0%) ₹ 8,662.50
27101990 ₹ 16,800.00 (18.0%) ₹ 3,024.00
85141000 ₹ 2,13,200.00 (18.0%) ₹ 38,376.00
Sub Total ₹ 11,90,205.00
IGST ₹ 2,14,236.90
Grand Total ₹ 14,04,441.90

NOTE: PLEASE REFER LAST PAGE FOR TERMS AND CONDITIONS


1. DETERMINATION OF PENETRATION
The Complete set up essentially consist of the following

1. Penetration Apparatus with Automatic Digital time controller - 1 No.


2. Cooling Water Bath With Digital Temp.controller to maintain at 25.0 ±
0.1°C - 1 No.
3. Penetration Needle - 3 Nos.
4. Mercury in Glass Thermometer Range: 0 to 44°C ; LC- 0.1 °C - 3 nos
5. Digital Time Device Accurate to within ± 0.1 s for a 60 s interval - 1 No
6 Container For penetrations below 225: Diameter, mm 55, Internal depth,
mm 35- 50 Nos

Compliance Standards:
IS 1448 (part 60), IS 1203, IS:73

1. Penetration Apparatus with Automatic Digital time controller - 1 No.


• Base with leveling screws with a vertical pillar mounted on it
• Head having a dial graduated in 40 x 0.1 mm divisions, plunger
rod and needle sliding on the pillar,
• Clamp on the pillar to tighten the needle
• Rack, pinion and pointer assembly
• Micrometer differential gearing system: Mechanism for fine
movement for head
• Automatic time controller the timer head allow the plunger rod to
fall freely for 5 seconds and clamps it automatically after
5 seconds.
• 220V, 50Hz, single phase supply

2. Cooling Water Bath With Digital Temp.controller to maintain at 25.0


± 0.1°C - 1 No.
The bath is double walled, inner chamber consisting of thick polished
stainless steel with cooling coil duly soldered on the outside of the same to
ensure perfect cooling effect to achieve low temp. up to +5°C. The outer
wall is of thick G.I. sheet duly pre-treated and powder coated for longer life.
The hollow space between the inner chamber and outer wall is filled with
The hollow space between the inner chamber and outer wall is filled with
high grade insulation of thickness 75 mm to prevent loss of
temperature.The refrigeration system consisting of Hermetically sealed
compressor for minimum noise level and smooth operation, Coupled with
other quality components, it ensures a high degree of reliability over a long
period. Heating system comprises of immersion type heating element for
attaining above ambient temperature. The unit is provided with a high
performance circulation stirrer to circulate the inside fluid to ensure a
constant and uniform temperature throughout. Temperature range 5°C to
50°C with PID digital temperature controller cum indicator. Chamber size. :
250 x 200 x 200 mm (L x B x H).
3. Penetration Needle - 3 Nos.
A straight, highly polished, cylindrical, stainless steel (SS 316), rod. The
needle is provided with a shank approximately 3 mm in diameter into which
it is immovably fixed.
4. Mercury in Glass Thermometer Range: 0 to 44°C ; LC- 0.1 °C - 3 nos
5. Digital Time Device Accurate to within ± 0.1 s for a 60 s interval - 1
No
6 Container For penetrations below 225: Diameter, mm 55, Internal
depth, mm 35- 50 Nos

Supplied with NABL Calibration certificate / Compliance certificate.

2. APPARATUS FOR SOLUBILITY IN TRI-CHLORO ETHYLENE-IS 1216 - METHOD A (FOR


ASPHALTIC BITUMEN)
Compliance Standards
Apparatus for Solubility with vacuum pump in Tri-chloro Ethylene as per IS 1216.

Details
Apparatus consists of following parts and accessories
• Gooch crucible - 5 nos.
• Conical flask 500 ml. capacity - 5 nos.
• Vacuum Pump - 1 no. for Filtration

Note
Following optional accessories are necessary to carry out the test.
1. Electronic Balance . 100 gm. x 0.001 gm. capacity
2. Desiccator 150 mm
3. Chemicals/Solvent (Carbon Disulphide, Trichloroethylene)
4. Hot Air Oven

3. DETERMINATION OF DUCTILITY
Application and principle
Ductility is defined as distance in cms to which a standard briquette of
bitumen can be stretched before the thread breaks. The briquette is
stretched at a rate of 50 mm/min. ± 2.5mm per minute at a temperature
from 5° to 30°C.

The Machine is having built in refrigeration system to work a below ambient


temperature up to 10°C in tropical conditions. The Machine will operate at
25°C with control accuracy of ± 0.1°C as per the requirement of IS.

Salient Features
• This instruments is specially designed for the tropical regions,
where radiation of sun-rays are higher than the average.
• The Machine is having built‑in refrigeration system to conduct
ductility test below ambient temperature up to 10 °C in tropical
ductility test below ambient temperature up to 10 °C in tropical
conditions.
• Entire instrument is mounted on a sturdy, rigid stand to
conduct the test with ease.
• Equipped with direct drive stepper motor to maintain
constant speed
• Vibration free and smooth operation
• Provides variable rates of pull / travel : 10‑100 mm/minute
• Brass/Bronze Gears to prevent rusting

Apparatus Description
The apparatus consists of water bath with refrigeration system and a
circulating pump to maintain uniform water temperature. One half of the
briquette moulds is fixed in a fixed plate in the water bath, the other half of
the briquette mould is fixed to a carrier, which slides over a rotating
threaded shaft with a clutch.

• Unit is fitted with Multi‑purpose Dedicated Touch screen


Graphics controller, which serves the purpose of
multi‑functionality.
• Heater on/off, Stepper Motor on/off, Stirrer on/off, Temperature
control and Elongation measurement ‑ All these functions are
operated & controlled through TOUCH SCREEN
CONTROLLER.
• Stepper Motor to achieve variable speed range from 10‑100
mm/min
• Speed is selected/altered through Touch screen Controller with
one‑touch. Required speed can be entered using online
keyboard.
• The motor and gears to rotate the shaft are housed in a cabinet
fixed above the other end of the bath.
• A pointer fixed to the carrier moves over a scale graduated from
0‑100 cm x 1mm fixed on the bath with "0" (Zero) of the scale
towards the fixed plates side.
• An operator can also log the Elongation Measurement
readings directly into the TOUCH SCREEN CONTROLLER,
with one touch Push. No need to observe it manually on the
scale, thereby eliminating the Human Error.
• An operator can also cross verify the logged elongation readings
with stainless steel scale to authentic the generated readings.
• Water bath inside is fabricated from of stainless steel material
with insulation and fitted with water drain cock
• Water bath is also fitted with immersion heater for temperature
control.
• Control panel is equipped with Mains switch, Heater indication
lamp, Stirrer indication lamp and Touch screen controller.
• Temperature control Accuracy : 0.1 C
• Speed range : 10‑100 mm/min
• Heater watts : 750 Watts
• Power consumption : 1 Kw
• Supplied complete with : Three briquette moulds and one base
plate
• Operates on : 230 volts, 50 hz, single phase, AC Supply

Refrigeration system
• Refrigeration system comprises of Compressor, cooling coil, and
condenser assembly.
• Compressor will be of Kirloskar/Emerson/Danfoss/Equivalent
reputed make.
• Complete refrigeration system will be provided with digital
control panel, which will be fitted below the ductility water bath
on sturdy stand frame.
• The digital control panel will be comprising of cooling switch,
mains switch and Microprocessor based Auto tune PID Digital
temperature controller cum indicator.

Optional Accessories At Extra Cost


• Data acquisition software
• Elastic Recovery Mould with Base Plate

• Click here for working video


: https://www.youtube.com/watch?v=SxU00_wlzA4&t=391s
4. DETERMINATION OF SOFTENING POINT
Description
Description
Compliance Standards
IS 73 | IS 1205

Construction Details:
The apparatus consist of a Glass beaker made up of heat
resistant glass having internal diameter of 8.5 cm and 12 cm depth
(approximately). The heater is controlled by a programmable Digital
Auto‑tune PID Temperature Controller Cum Indicator to ensure rise of
temperature at 5° C as per the guidelines

Electrical Motorized with DC Magnetic drive concealed heating and


programmable DIGITAL PID temperature indicator cum controller to
ensure rise of temperature @ 5 °C as per IS, IP and ASTM
Requirements.

Following Accessories will be included in the standard supply:


• Complete Heating & Stirring assembly
• Glass Vessel with Cover : A heat resistance glass vessel not
less than 85 mm in diameter and 120 mm in depth. : 2 Nos.
• Cork for Thermometer
• Steel balls ‑ each of 9.5 mm diameter, weighing 3.50 ± 0.05 gm
: 2 Nos.
• Tapered brass rings of the following dimensions : 2 Nos.
☐ Depth : 6.4 ± 0.1 mm
☐ Inside diameter at bottom: 15.9± 0.1 mm
☐ Inside diameter at top: 17.5± 0.1 mm
☐ Outside diameter: 20.6± 0.1 mm, the outside diameter of the ring
at the bottom will be smaller, but not less than 19.0 mm.
• Ball guides - 2 Nos.
• Ring & Ball Stand : 2 Nos. having following specifications
☐ The rings will be supported in a horizontal position with the
upper surface of the rings 50 mm below the surface of the bath
liquid.
☐ There will be a distance of exactly 25 mm between the bottom of
☐ There will be a distance of exactly 25 mm between the bottom of
the rings and the top surface of the bottom plate of the support
☐ The thermometer will be suspended so that the bottom of the
bulb level with the bottom of the rings, and within 10 mm of the
rings
• Glass Thermometer : Low Temperature: -2 °C to 80
°C,Graduation at each 0.2 °C : 3 Nos.
• Glass Thermometer : High Temperature: 30 °C to 2000
°C,Graduation at each 0.5 °C : 3 Nos.

Supplied with NABL Calibration certificate / Compliance certificate.

5. ABSOLUTE VISCOSITY BATH FOR 2 VISCOMETER - FOR BITUMEN 60C


Description
As per IS: 1206 (Part II).Supplied complete with Viscosity bath for 2 viscometer tube with built in Digital stop watch, Vacuum Pump -
capable to maintain vacuum of 300 mm/Hg,with required accuracy, Indian Make Vacuum Manning Viscometer No. 11, 12 and 13,
silicon tubes and calibration certificate for Viscosity bath, certificate of constant for Viscometers. Complete with instruction
manual. Detailed Specification as mentioned in technical part mentioned below

Compliance with following International Standards :


Complete Absolute and kinematic Viscosity Testing Equipment conforming to IS 1206 (Part II).

Apparatus Details :
Determination of Absolute and kinematic Viscosity with the following components:
1. Constant Temperature Bath ‑ A suitable bath for immersion of 2 vacuum capillary viscometer tubes with a digital temperature
controller. The accuracy of the temperature in the bath will be ± 0.1°C throughout the bath. : 1 No.
2. Digital Vacuum System ‑ The system will consist of vacuum pump, moisture trap, Digital vacuum regulator, bleed valve, all
interconnecting tubing / piping, and any other accessories as needed to complete the vacuum system. A vacuum system
will be capable of maintaining a vacuum to within ± 0.05 cm of the desired level : 1 No
3. Built in Digital Timing Device ‑ A stop watch capable of reading up to 0.01 second. : 1 No.
4. Indian Make Cannon‑Manning Vacuum Viscometer Tubes of Size 12 and 13 viscometer tube holder and silicone cork. This
will cover the Viscosity range from 120-2400, 360-8000 and 1200-24000 poises. : 3 Nos. each size
5. Glass Thermometer : GLASS THERMOMETER 37.8C - 80C x 0.2C - 2 Nos.

6. KINEMATIC VISCOSITY BATH FOR BITUMEN - @ 135°C


Description
As per IS: 1206 (Part III). Supplied complete with Viscosity bath for 2 viscometer tube with built in Digital stop watch, Reverse flow
Viscometer No.6, Silicon oil, silicon tubes and calibration certificate for Viscosity bath, certificate of constant for Viscometers.
Complete with instruction manual. Detailed Specification as mentioned in technical part mentioned below.

Compliance with following International Standards :


Complete kinematic Viscosity Testing Equipment conforming to IS 1206 (Part III)

Apparatus Details:
Determination of kinematic Viscosity with the following components:
1. Constant Temperature Bath ‑ A suitable bath for immersion of 2 vacuum capillary viscometer tubes with a digital temperature
controller. The accuracy of the temperature in the bath will be ± 0.1°C throughout the bath.
2. Silicone bath oil having 20.0 cSt @ 135°C ‑ 20 Liters
3. Built in Digital Timing Device ‑ A stop watch capable of reading up to 0.01 second.
4. Indian Make Canon-Fenske Opaque Viscometers Size No. 6 with certificate of constant : 4 Nos. each size
5. Indian Make Canon-Fenske Opaque Viscometers Size No. 7 with certificate of constant : 2 Nos. each size
6. Mercury in Glass Thermometer with Calibration certificate : 3 Nos.
7. Digital Stop Watch : 1 Nos.

7. ROLLING THIN FILM OVEN


Description
☐ ROLLING THIN FILM OVEN

Complies with following International Standards:


ASTM D2872; AASHTO T240 ; CNR N.54; EN 12607 - 1, IS 15799-2008

Application:
Determination of the resistance of bituminous binder to hardening under the
influence of heat and air : Rolling Thin Film Oven Test

Introduction:
This unit simulates the hardening that affects binder during its mixture with
aggregates in the plant and during the finishing & rolling of the bituminous
layers (Short Term Ageing ). Provides the binder sample ready for change
in mass determination and for other tests that characterize the binder about
in mass determination and for other tests that characterize the binder about
the resistance to short term ageing.

Salient Features:
• Double walled electrically heated conventional type oven with
high glass wool density insulation to prevent thermal loss
• Over temperature automatic switch;
• Automatic switch that switches off the oven in case of accidental
opening of the door during the test;
• Spy lamp and alarm for door open with fan still running
• Magnetothermic switch.
• Double walled, inner chamber S.S.304, Outer CRC Powder
coated.
• Thermal insulation with high quality material.
• Door with high resistance glass separated by an air space
offering uninterrupted view of inside of the oven
• Armored heating resistance to safety requirement.
• Flow meter (Rota meter), with air flow regulator
• Transmission of movement of the vertical carriage and of the
squirrel cage - type fan by toothed belt, to grant constant speed.
• Digital electronic thermo regulator operating in PID mode. By
this way it is assured that the test temperature recovery time
is complying with the specifications, that is 10 minutes after
1 minute with door open (estimated time necessary for
the positioning of the glass containers with sample into
the vertical carriage).
• Cooling fan operating all over the test to protect the movement
transmission of the squirrel cage fan and of the vertical carriage
• Rotating shelf constructed such that it offers minimum resistance
to air circulation for better heat distribution while sample
container are in place
• Complete with pilot indicating lamps, 2 meter cord wire and
power plug.

Details of Apparatus:
The entire test method comprises one each of Hot Air oven, Rotating Shelf
(Vertical circular carriage), Sample Containers and Thermometer as per
following descriptions.
following descriptions.

Rotating Shelf:
• Single metal Vertical circular carriage having diameter of
304.8mm as per ASTM D2872
• Shelf construction is such that it provides a flat surface for
support of the containers without blocking air circulation through
the shelf when the containers are in place.
• Shelf is suspended by a Horizontal shaft and centered with
respect to the vertical interior dimensions of the oven
• Shelf is rotated by electric motor at a speed of 15 ± 0.2 RPM as
per ASTM D2872
• Can accommodate four (8) no glass sample containers

Sample Containers:
• Inside Diameter : 64 mm ± 1.2 mm
• Depth : 139.7 mm
• Flat bottom design
• Made of clear, transparent, heat resistant glass material

GLASS CONTAINER RACK-BOTTLE COOLING RACK-FOR ROLLING


THIN FILM OVEN
• Fabricated from Mild Steel Material
• Powder coated in attractive shades
• Provides convenient bench top storage.
• Accommodates up to 9 Bottles
• Minimizes the risk of breakage

Thermometer:
• ASTM 13C thermometer - 3 nos.
• Supplied with calibration traceability to National Standards as
per - IEC/ISO 17025

Supplied with NABL Calibration certificate


Technical Specification

•Working size : 483 x 445 x 381cm ( W x D x H)

•Volume : 82 Liters

•Rating : 2.0 KW

•Temperature Range : 50 °C - 300 °C

•Temperature Control : Microprocessor based Auto-


Tuning Digital PID temperature
controller cum indicator

•Temperature Display : LED Digital display

•Temperature sensor : PT-100 sensor

•Temperature Resolution : 0.1 °C

•Temperature Accuracy : ± 1 °C or better

•Shaft : Rotating Vertical Circular carriage


for sample containers as
mentioned in ASTM D2872
standard

•Carriage Rotation : Rotated by electric motor at 15 ±


0.2 RPM as per ASTM D2872

•Electric Motor : Of reputed make

•Glass container : Clear, transparent, Heat resistant


glass containers to be held in
Circular carriage

•No of glass containers : 08 Nos

•Air jet orifice : 1.016 mm diameter

•Copper tubing dimensions : 7.6 meter length and 8 mm


outside diameter

•Construction : Tripple walled construction

•Exterior body : Made of mild steel material,


which is powder coated in
attractive shades
attractive shades

•Inner chamber : Made of Stainless Steel S.S. 304


- mirror polished material.

•Insulation : High density glass wool insulation


- (2.5”) in all sides of chamber to
offer minimum heat loss

•Heating element : Heating elements placed at the


bottom of the oven Floor as per
ASTM D2872

•Blower : Suspended vertically from the


ceiling of the oven for uniform heat
distribution inside the working
chamber

•Door lock : Special heavy duty Stainless


steel lock and door hinges with
spring and roller mechanism

•Observation window : With two sheets of glass


separated by an air space, 11” x
13” (H x W)

•Ventilation : Adjustable air ventilation mounted


at top and bottom for dissipation of
expended volatile from specimen
as per ASTM D2872

•Rate of air flow : Calibrated flow meter measuring


range 0 - 4000 ml/min

•Operation on : 230 volts, 50 hz, Single phase,


AC Supply

•Internal circuitry wires : As per CE Compliance

•Design : CE CERTIFIED Design criteria

8. CLEAVELAND FLASH POINT APPARATUS -WITH DIGITAL TEMPERATURE INDICATOR


With Digital Temperature Indicator along with Combined wick system
arrangement. (Either by Gas jet or by Oil wick arrangement)

Compliance with following International Standards


IP 36/57, IS 1448 (P:69) 1969 and ASTM D92

Application:
This apparatus is used for determination of Flash Point of petroleum
products except fuel oil with open flash above 80°C as per specification
given in IP 36/57, IS 1448 (P:69) 1969 and ASTM-D-92-67.

Significance & Use:


Flash point is used in shipping and safety regulations to define flammable
and combustible materials. Flash point can indicate the possible presence
of highly volatile and flammable materials in a relatively nonvolatile or
nonflammable material. The flash point is one measure of the tendency of
the test specimen to form a flammable mixture with air under controlled
laboratory conditions.

Construction Details:
• This apparatus consists of the test cup, heating plate, test flame
applicator, heater, supports as described in IP and in ASTM
specifications.
• The complete apparatus is manufactured from Brass or Stainless
Steel Material
• Heater is controlled by energy regulator and temperature
displayed on Digital temperature indicator fitted to the apparatus.
• Suitable for operation on 220 Volts, 50 cycles AC mains supply.
• Aesthetic outer appearance
• Low cost model
Commercial Terms & Conditions :-

1. Validity : 30 days from the date of quotation.


2. Packing : Inclusive
3. Freight : Inclusive
4. Insurance : Inclusive
5. Delivery : Within 6 to 8 Weeks after receipt of technically and commercially clear firm order in writing.
6. Payment : Within 30 days of successful demonstration.
7. Warranty : The offered Item/s is warranted for ONE YEAR from the date of supply for any inherent, manufacturing defect, if any, on the
part of manufacturer. The defects due to power fluctuation, improper earthing, false operation of machine, over loading etc. will not be
covered under this warranty.
8. Demonstration : Free demonstration at your site. Civil, Mechanical and Electrical jobs for the commissioning (if applicable) will be out of
our scope. Before calling us for the demonstration, the laboratory should be ready with the adequate stabilized Power supply, skilled
operator, Lubricating Oil, Grease etc.(if required) to make the Instrument functional.

Bank Details :
Bank of Baroda
• Account No. : 31940500000054
• IFSC : BARB0BAPUNA ( Fifth Character is Zero)
• MICR : 380012075

For, EIE Instruments Pvt. Ltd.


Name : Vansh Chudasama
Phone No : 07966211237
Whatsapp No : 9227230010
Email : [email protected]
Vansh Chudasama
Prepared By Checked By Authorised By

You might also like