Electrode Selection Guide v1 - 4
Electrode Selection Guide v1 - 4
Electrode Selection Guide v1 - 4
n
tio
tio
nc
ip
nc
ti p
rT
Ju
le
Ju
ng
cro
tio oub
ea
ar
id
r T 48A
id
t
Lo
y
Fla
pe
Sp
Mi
iqu
ox
iqu
lat
Ju h™ D
32
0
s
n
Sp e N1
h™
™
Ep
yF
yL
ip
sL
eL
s
PH
PH
de
as
gh
gh
gh
gh
s
nc
ox
ox
™
ug
tro
13
21
Lin
as
as
Li n
Gl
ea
ou
ou
ou
ou
ou
-pH
Ep
Ep
To
Gl
Gl
lec
ne
ne
ce
ab
yT
yT
yT
yT
yT
ce
xy
pid
pid
pid
pid
pid
eli
eli
i en
1e
ox
ox
ox
ox
ox
ien
ml
o
Blu
Blu
Ca
Ra
Ra
Ra
Ra
Ra
Ep
Ep
Ep
Ep
Ep
Ep
P1
Sc
Sc
Camlab Sentek SI Analytics
pH Diameter, mm
Length, mm
12
150
12
150
12
150
12
150
12
150
15
120
12
150
6
150
9.5
300
9.9
120
12
150
12
150
12
120
12
170
25
65
12
120
12
120
Construction Epoxy Glass Glass Epoxy Epoxy Epoxy Epoxy Epoxy Epoxy Epoxy Epoxy Glass Glass Glass Plastic Glass Glass
pH is a measurement of the concentration of hydrogen ions (H+) in a There are a variety of different types of electrode available to fit different
substance. The scale it is measured on runs from 0 to 14. applications. Electrodes may have any combination of these features to make
them suitable for specific samples.
A reading of 7 is neutral, below this is acidic and above this is alkaline
or basic. Double Junction – these electrodes have an additional salt bridge to prevent
reactions between the electrode fill solution and your sample which would
otherwise cause damage to the electrode junction. They are required to test
Electrode Cables
samples that contain proteins, heavy metals or sulphides.
If you are using an electrode which has an S7 screw top you may also
Liquid Junction – A liquid junction electrode creates a junction with a thin film
need a cable to connect it to your meter. The part numbers for these
of filling solution at the tip of the probe. They usually have a pump function to
are;
allow you to create a fresh junction for every use. They do need refilling
1147028 S7 to BNC
regularly but offer the best performance increasing lifetime, accuracy and
1147027 S7 to DIN
speed of response.
Adapter Cables
Flat – the end of these electrodes is perfectly flat so a reading can be taken
An adapter cable will allow you to use an electrode with a BNC
from the surface of a solid sample. These may be used for measuring fabrics,
connection on a meter that requires a DIN connection;
biological tissues or pastes.
1161706 BNC to DIN adapter
1161707 BNC to US Standard Beckman
Spear Tip – the pointed tip of these electrodes mean you can pierce solid
Electrode Care and Maintenance samples to take a reading. Typical applications include meat, cheese or soil.
Between uses your electrode should be stored in a 3.0M KCl EpoxyToughTM – these electrodes are filled with gel rather than traditional
(potassium chloride) solution. An electrode storage bottle will help liquid filled models, so you do not need to refill them.
ensure that the electrode tip is not damaged and that the solution
doesn’t evaporate over time. Micro – this small, slim electrode means that you can test when you have only
a small amount of sample, or your sample is in a small container.
1161708 Electrode storage bottle
1111609 pH electrode storage solution 500ml
Calibration Questions?
Electrodes should be calibrated using pH buffer to ensure they are Can’t see your application here, or unsure of what you need?
reading accurately. A 3 point calibration at pH 4, 7 and 10 is most
common, but check the manual of your pH meter to see what it If you need any further information or advice on your pH reading application
requires. See our range of pH buffers here. contact our technical support team; [email protected]