DESIGN ANALYSIS VICINITY MAP

SHORT CIRCUIT CALCULATION VOLTAGE DROP CALCULATION


MOUNTAIN HEIGHTS
HIGH SCHOOL

1. Unlimited Available Short Circuit Current. IscA 4. Short Circuit @ Fault. Isc = IscA x M VOLTAGE DROP CALCULATION: (AT CPS-2)
IscA3Ø = FULL LOAD CURRENT / ZP.u. x 0.09 RATED CURRENT AT CSP-2 = 12.23 AMPS. VD = {(2 x 12.23 x 805 x 0.491) / 1000}
*UL (Std.1561) listed transformers 25kVA and larger have a ± 10% impedence LONGETS CABLE LENGTH = 805 FT = 9.67 volts
tolerance. UNLIMITED AVAILABLE SHORT CIRCUITCURRENT (SCI) FROM ST. DOMINIC
SAVIO
COLLEGE

Short circuit amps can be affected by this tolerance for high and worst case. UTILITY VOLTAGE DROP @ PANELBOARD
multipy %7. by 0.09. For low end of worst case, multiply %7. by 1.1. IscA = FULL LOAD CURRENT / Zp.u. x 0.09 V = 230 volts - 9.67 volts
S
= 12.23 / (0.0575 x 0.09) = 220.33 volts
2. Single -Phase 1.732 x IscA1Ø = 2.36 kAMPS.
f = 1Ø FAULT (f) = L x IscA / C x n x V PERCENTAGE OF VOLTAGE DROP @ PANELBOARD
1Ø CxnxV = 805 x 2.36 x 1000 / 2425 x 1 x 230 %VD = (Voltage drop / source voltage) x 100
where: f - single phase fault = 3.41 = 4.2%
L - length (ft.) of conductor to the fault M =1/1+f
IscA - available short circuit current M = 1 / 1 + 3.41
C - conctant from Table 2 "C" value of conductors M = 0.23 NOTE: MAX % VD SHOULD BE NO MORE THAN 5.00%
n - no. of conductor per phase Isc = IscA x M
V - voltage of circuit Isc = 2.36 kAMPS. x 0.23
Isc = 0.54 kAMPS.
3. Multiplier. M 1
M = THEREFORE INTERRUPTING DUTY OF
1+f MAIN CIRCUIT BREAKER IS 0.54 kAMPS. USE MINIMUM 10 KAIC

ALONG MT. APO ST, MOUNTAIN HEIGHTS SUBD.


SUMMARY OF QUANTITIES

SCHEDULE OF LOADS
ITEM NO. SUMMARY OF QUANTITIES UNITS QUANTITY

A.1.4(1) PROVISION OF PROGRESS PHOTOGRAPHS EA. 50.00


OFFICES, SHOPS, STORES AND WORKMEN'S Estimated Longest
B.1 L.S. 1.00 Mark Load Description Qty. Watt Volt VA Amp. Length (CSP to Load) CB Main Feeder
ACCOMODATION FOR CONTRACTOR
Feet
B.3 PERMITS AND CLEARANCES L.S. 1.00
2 - 14.0 SQ.MM THW/1-5.5 SQ.MM
70AT,2P, 10 KAIC
B.5 PROJECT BILLBOARD/SIGNBOARD EA. 2.00 THW GRND VIA AERIAL; USE
CSP-1 LED TYPE 150W 15 2250 230 2813 12.23 709 Enclosed CB in
25MMØ RSC PIPE FOR SERVICE
B.7 (2) Nema-4x
OCCUPATIONAL SAFETY AND HEALTH PROGRAM L.S. 1.00 ENTRANCE

B.8 (1) TRAFFIC MANAGEMENT MO. 2.50 2 - 14.0 SQ.MM THW/1-5.5 SQ.MM
70AT,2P, 10 KAIC
THW GRND VIA AERIAL; USE
B.9 MOBILIZATION/DEMOBILIZATION L.S. 1.00 CSP-2 LED TYPE 150W 15 2250 230 2813 12.23 805 Enclosed CB in
25MMØ RSC PIPE FOR SERVICE
Nema-4x
ENTRANCE
REMOVAL OF ACTUAL STRUCTURES/OBSTRUCTION(0.15M
101(3)
THK. PCCP) UNREINFORCED M2 70.00
2 - 14.0 SQ.MM THW/1-5.5 SQ.MM
70AT,2P, 10 KAIC
THW GRND VIA AERIAL; USE
3 CSP-3 LED TYPE 150W 15 2250 230 2813 12.23 663 Enclosed CB in
103(1).a STRUCTURE EXCAVATION, COMMON SOIL M 96.00 Nema-4x
25MMØ RSC PIPE FOR SERVICE
ENTRANCE
1706 (1) 3
OVERHAUL M 107.00
804(4) 3
GRAVEL FILL M 5.00
404(1).a REINFORCING STEEL, GRADE 40 KG 5208.93
405(1).a3 3
STRUCTURAL CONCRETE, 20.68 MPa, 28 DAYS M 40.00

624(1).a3 SINGLE ARM POST, WITH STREET LIGHT, LED, 150W EA. 45.00

FROM THE: PROJECT TITLE / LOCATION REVIEWED AND CHECKED: ELECTRICAL: REVIEWED: APPROVED: CONCURRED: SHEET NO.

ENGR. JASON V. MORAL


NISTALLAO
TINOFSTREETGLIHTSALONGMAT.PO

E-1
MEPF SECTION
CITY ENGINEERING DEPARTMENT
SM
T,OUNTA
NIHE
GIHTSSUBD VO
S
IIN
B
,RGY8
13
., DESIGNED BY:
8 TH AV E . C O RN E R 8 TH ST . S O U TH CA LO O CA N C I TY CESAR S. BRAVO, PEE
CALOOCANC
TY
I ELECTRICAL CONSULTANT AR. JEMUEL P. BAYLON ENGR. ERROL L. BITANGA HON. DALE GONZALO R. MALAPITAN
CITY GOVERNMENT OF CALOOCAN ENGR. JOHN KENNETH P. MAGABO PLANNING & PROGRAMMING DIVISION CITY ENGINEER CITY MAYOR

You might also like