Guardhouse PDF

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

General Notes

1- REFERENCES
ALL ENGINEERS DRAWING SHALL BE READ IN CONJUNCTION WITH ALL
ANY DISCREPANCIES SHOULD BE REPORTED TO
ARCHITECTS DRAWINGS.

P
BOTH THE ARCHITECT AND THE ENGINEER.
2 - DIMENSIONS
ALL DIMENSIONS ARE IN MILLIMETRES ( UNLESS STATED OTHERWISE )
3 - FOUNDATIONS
2
FOUNDATIONS HAVE BEEN DESIGNED ON BEARING PRESSURE OF 200 KN/m
FOUNDATION DEPTH TO BE DETERMINED BY ENGINEER PRIOR TO PLACING
CONCRETE. MINIMUM FOUNDATION DEPTH TO BE 1000mm BELOW FLOOR

200 1800 200 LEVEL OR 600 mm BELOW SPLASH APRON LEVEL WHICHEVER IS CRITICAL
MAXIMUM ALLOWABLE FILL BELOW GROUND SLAB = 500 mm
4 - BLOCK WORK
ALL LOAD BEARING BLOCK WALLS TO BE CONSTRUCTED FROM SOLID BLOCK
OF 5.0 N/mm MIN. CHARACTERISTIC COMPRESSION STRENGTH COMPLYING
WITH BS 5628 PART1 1978 STRUCTURAL USE OF UNREINFORCED MASONRY
MORTAR TO CONFORM TO MORTAR DESIGNATION ( III ) OF TABLE 1
BS 5628 PART1
5 - CONCRETE

200
PERMITTED TYPE
GRADE AGGREGATE MAX. SIZE WORKABILITY
PROPOSED USE AGGREGATE
COARSE FINE
REINFORCED CONC.
C 25 BS 882 BS 882 20mm MEDIUM
( INCLUDING GROUND ( 75 )
BEARING SLAB )
CONCRETE BS 882 BS 882 40mm MEDIUM
CONTAINING NO C 15
EMBEDDED METAL ( 75 )

BS 882 BS 882 20mm MEDIUM


BLINDING CONCRETE C 7.5 ( 75 )

CONCRETE IN MINOR C 25 BS 882 BS 882 10mm MEDIUM


ELEMENTS e.g LINTELS ( 75 )
2400

2000
COVER
LOCATION COVER

TO MESH IN GROUND SLAB 30 mm


COLUMNS ( COVER TO LINKS ) 25 mm
SLAB ( COVER TO MAIN BARS ) 25 mm
FOUNDATIONS
TOP AND BOTTOM 50 mm
SIDES 75 mm

5 - JOINTS
MOVEMENT JOINTS TO BE AT A MAXIMUM 9.0M CENTRES. JOINT POSITIONS
AS INDICATED ON DRG. JOINT IN SALB TO BE CARRIED THROUGH WALLS
TO UNDERSIDE OF RING BEAM
6 - WALL TIES
200

PROVIDE MASONRY ANCHORS EVERY 2 COURSES USING GALVANISED .


MILD STEEL DEBOND TIES TO BS 1243 . 1978
7 - REINFORCEMENT
REINFORCEMENT TO BE IN ACCORDANCE WITH CONSULTING ENGINEER'S
SPECIFICATION.
R - - - - - - - DENOTES ROUND MILD STEEL BARS
Y - - - - - - - DENOTES HIGH YIELD BOND STRENGTH BARS.

NOTES

2200 1. All dimensions in mm unless otherwise stated

determined on site.

P Detailed Engineering Design


NM/SD/3.1

Client:

THE REPUBLIC OF UGANDA


MAYUGE DISTRICT LOCAL
GOVERNMENT

Project title:

FEASIBILITY STUDY AND DETAILED ENGINEERING DESIGN


OF BUKABOOLI MINI PIPED WATER SUPPLY SYSTEM

Consultant:

GUARD HOUSE DETAILS


ROK TECHNICAL
SERVICES LTD
Scales:
NTS
Gauge 28 GCI sheets
on 75 x 50 purlins
on 100 x 50 rafters General Notes
on 150 x 50 beams 1- REFERENCES
ALL ENGINEERS DRAWING SHALL BE READ IN CONJUNCTION WITH ALL
ANY DISCREPANCIES SHOULD BE REPORTED TO
ARCHITECTS DRAWINGS.
on 100 x 150 strut BOTH THE ARCHITECT AND THE ENGINEER.
2 - DIMENSIONS

on 100 x 100 wall plate ALL DIMENSIONS ARE IN MILLIMETRES ( UNLESS STATED OTHERWISE )
3 - FOUNDATIONS
2
FOUNDATIONS HAVE BEEN DESIGNED ON BEARING PRESSURE OF 200 KN/m
FOUNDATION DEPTH TO BE DETERMINED BY ENGINEER PRIOR TO PLACING
CONCRETE. MINIMUM FOUNDATION DEPTH TO BE 1000mm BELOW FLOOR
LEVEL OR 600 mm BELOW SPLASH APRON LEVEL WHICHEVER IS CRITICAL
MAXIMUM ALLOWABLE FILL BELOW GROUND SLAB = 500 mm
4 - BLOCK WORK
ALL LOAD BEARING BLOCK WALLS TO BE CONSTRUCTED FROM SOLID BLOCK
OF 5.0 N/mm MIN. CHARACTERISTIC COMPRESSION STRENGTH COMPLYING
WITH BS 5628 PART1 1978 STRUCTURAL USE OF UNREINFORCED MASONRY
MORTAR TO CONFORM TO MORTAR DESIGNATION ( III ) OF TABLE 1
BS 5628 PART1

Ring Beam

200
5 - CONCRETE
PERMITTED TYPE
GRADE AGGREGATE MAX. SIZE WORKABILITY
PROPOSED USE AGGREGATE
COARSE FINE
REINFORCED CONC.
C 25 BS 882 BS 882 20mm MEDIUM
( INCLUDING GROUND ( 75 )
BEARING SLAB )
CONCRETE BS 882 BS 882 40mm
5mm glass puttyed in steel CONTAINING NO
EMBEDDED METAL
C 15 MEDIUM
( 75 )

1200
casement window frame BLINDING CONCRETE C 7.5
BS 882 BS 882 20mm MEDIUM
( 75 )

CONCRETE IN MINOR C 25 BS 882 BS 882 10mm MEDIUM


ELEMENTS e.g LINTELS ( 75 )

COVER
LOCATION COVER

TO MESH IN GROUND SLAB 30 mm


COLUMNS ( COVER TO LINKS ) 25 mm
SLAB ( COVER TO MAIN BARS ) 25 mm
FOUNDATIONS
TOP AND BOTTOM 50 mm
SIDES 75 mm

100mm thick floor slab

900
5 - JOINTS
MOVEMENT JOINTS TO BE AT A MAXIMUM 9.0M CENTRES. JOINT POSITIONS
AS INDICATED ON DRG. JOINT IN SALB TO BE CARRIED THROUGH WALLS
to engineer's approval TO UNDERSIDE OF RING BEAM
6 - WALL TIES
PROVIDE MASONRY ANCHORS EVERY 2 COURSES USING GALVANISED .
MILD STEEL DEBOND TIES TO BS 1243 . 1978
7 - REINFORCEMENT
REINFORCEMENT TO BE IN ACCORDANCE WITH CONSULTING ENGINEER'S
SPECIFICATION.
R - - - - - - - DENOTES ROUND MILD STEEL BARS
Y - - - - - - - DENOTES HIGH YIELD BOND STRENGTH BARS.

NOTES
1. All dimensions in mm unless otherwise stated

determined on site.

200mm thick brick wall


600mm wide Strip to approval
Concrete Foundation Detailed Engineering Design
to engineer's approval
NM/SD/3.2

Client:

THE REPUBLIC OF UGANDA


MAYUGE DISTRICT LOCAL
GOVERNMENT

Project title:

FEASIBILITY STUDY AND DETAILED ENGINEERING DESIGN


OF BUKABOOLI MINI PIPED WATER SUPPLY SYSTEM

Steel door
900x2100
on steel framing Consultant:

GUARD HOUSE DETAILS


ROK TECHNICAL
SERVICES LTD
Scales:
NTS

You might also like