1- REFERENCES
ALL ENGINEERS DRAWING SHALL BE READ IN CONJUNCTION WITH ALL
ANY DISCREPANCIES SHOULD BE REPORTED TO
ARCHITECTS DRAWINGS.
P
BOTH THE ARCHITECT AND THE ENGINEER.
2 - DIMENSIONS
ALL DIMENSIONS ARE IN MILLIMETRES ( UNLESS STATED OTHERWISE )
3 - FOUNDATIONS
2
FOUNDATIONS HAVE BEEN DESIGNED ON BEARING PRESSURE OF 200 KN/m
FOUNDATION DEPTH TO BE DETERMINED BY ENGINEER PRIOR TO PLACING
CONCRETE. MINIMUM FOUNDATION DEPTH TO BE 1000mm BELOW FLOOR
200 1800 200 LEVEL OR 600 mm BELOW SPLASH APRON LEVEL WHICHEVER IS CRITICAL
MAXIMUM ALLOWABLE FILL BELOW GROUND SLAB = 500 mm
4 - BLOCK WORK
ALL LOAD BEARING BLOCK WALLS TO BE CONSTRUCTED FROM SOLID BLOCK
OF 5.0 N/mm MIN. CHARACTERISTIC COMPRESSION STRENGTH COMPLYING
WITH BS 5628 PART1 1978 STRUCTURAL USE OF UNREINFORCED MASONRY
MORTAR TO CONFORM TO MORTAR DESIGNATION ( III ) OF TABLE 1
BS 5628 PART1
5 - CONCRETE
200
PERMITTED TYPE
GRADE AGGREGATE MAX. SIZE WORKABILITY
PROPOSED USE AGGREGATE
COARSE FINE
REINFORCED CONC.
C 25 BS 882 BS 882 20mm MEDIUM
( INCLUDING GROUND ( 75 )
BEARING SLAB )
CONCRETE BS 882 BS 882 40mm MEDIUM
CONTAINING NO C 15
EMBEDDED METAL ( 75 )
2000
COVER
LOCATION COVER
5 - JOINTS
MOVEMENT JOINTS TO BE AT A MAXIMUM 9.0M CENTRES. JOINT POSITIONS
AS INDICATED ON DRG. JOINT IN SALB TO BE CARRIED THROUGH WALLS
TO UNDERSIDE OF RING BEAM
6 - WALL TIES
200
NOTES
determined on site.
Client:
Project title:
Consultant:
on 100 x 100 wall plate ALL DIMENSIONS ARE IN MILLIMETRES ( UNLESS STATED OTHERWISE )
3 - FOUNDATIONS
2
FOUNDATIONS HAVE BEEN DESIGNED ON BEARING PRESSURE OF 200 KN/m
FOUNDATION DEPTH TO BE DETERMINED BY ENGINEER PRIOR TO PLACING
CONCRETE. MINIMUM FOUNDATION DEPTH TO BE 1000mm BELOW FLOOR
LEVEL OR 600 mm BELOW SPLASH APRON LEVEL WHICHEVER IS CRITICAL
MAXIMUM ALLOWABLE FILL BELOW GROUND SLAB = 500 mm
4 - BLOCK WORK
ALL LOAD BEARING BLOCK WALLS TO BE CONSTRUCTED FROM SOLID BLOCK
OF 5.0 N/mm MIN. CHARACTERISTIC COMPRESSION STRENGTH COMPLYING
WITH BS 5628 PART1 1978 STRUCTURAL USE OF UNREINFORCED MASONRY
MORTAR TO CONFORM TO MORTAR DESIGNATION ( III ) OF TABLE 1
BS 5628 PART1
Ring Beam
200
5 - CONCRETE
PERMITTED TYPE
GRADE AGGREGATE MAX. SIZE WORKABILITY
PROPOSED USE AGGREGATE
COARSE FINE
REINFORCED CONC.
C 25 BS 882 BS 882 20mm MEDIUM
( INCLUDING GROUND ( 75 )
BEARING SLAB )
CONCRETE BS 882 BS 882 40mm
5mm glass puttyed in steel CONTAINING NO
EMBEDDED METAL
C 15 MEDIUM
( 75 )
1200
casement window frame BLINDING CONCRETE C 7.5
BS 882 BS 882 20mm MEDIUM
( 75 )
COVER
LOCATION COVER
900
5 - JOINTS
MOVEMENT JOINTS TO BE AT A MAXIMUM 9.0M CENTRES. JOINT POSITIONS
AS INDICATED ON DRG. JOINT IN SALB TO BE CARRIED THROUGH WALLS
to engineer's approval TO UNDERSIDE OF RING BEAM
6 - WALL TIES
PROVIDE MASONRY ANCHORS EVERY 2 COURSES USING GALVANISED .
MILD STEEL DEBOND TIES TO BS 1243 . 1978
7 - REINFORCEMENT
REINFORCEMENT TO BE IN ACCORDANCE WITH CONSULTING ENGINEER'S
SPECIFICATION.
R - - - - - - - DENOTES ROUND MILD STEEL BARS
Y - - - - - - - DENOTES HIGH YIELD BOND STRENGTH BARS.
NOTES
1. All dimensions in mm unless otherwise stated
determined on site.
Client:
Project title:
Steel door
900x2100
on steel framing Consultant: