Loadermanual
Loadermanual
Before using the card, download the Daikin Shared Data App
for iOS in AppStore or Android in Google Play. Be sure to
register for an account before continuing.
A. Power Switch ‐ Can be placed in the ON or OFF position. You can also Review the Pre‐Programming Procedures from
this page.
The device must be powered on to program Shared Data from
the compatible Daikin Shared Data App and to load Shared
Data onto any compatible equipment.
B. Status LED – Will blink periodically when the device is
powered on. The Status LED will blink once every 4 seconds
when the device is powered on normally. The Status LED will
blink 3 times in quick succession to indicate the battery is low
and will need to be replaced soon.
C. Shared Data Loading Connector
D. Battery/Battery Slot – Accepts a CR2032 3V coin cell
battery. A battery is needed to power the Bluetooth® loader
independently. One‐coin battery is provided in the packaging.
Ensure the positive side is facing up and slide the battery into
the battery slot.
2
DAIKIN NORTH AMERICA LLC • 19001 Kermier Road • Waller, TX 77484
Main: 713.861.2500 • Marketing Fax: 713.331.3275
www.northamerica‐daikin.com
Daikin Shared Data Loader User Manual
The appropriate Shared Data can be selected by either After scanning or manually selecting the desired model
scanning a barcode found on the unit using the phone number, review the information on this screen is correct,
camera, or by typing in the model number of the unit. If then click “Confirm and Continue” to program the selected
possible, scanning the 2D barcode is recommended to get the Shared Data onto the card.
most accurate results. If this barcode is faded, damaged, or
cannot be found, then it will be necessary to enter the model If the information shown on the confirmation screen does not
number manually. look correct, it may be necessary to choose a different set of
The 2D barcode can typically be found somewhere inside the Shared Data. Return to the previous screens and ensure the
unit. If you are having trouble locating the 2D bar code, you model number provided in the app is correct.
can click the “Need help finding your barcode?” link which
will show where to locate the barcode on products. The app will then present a confirmation screen once loaded.
3
DAIKIN NORTH AMERICA LLC • 19001 Kermier Road • Waller, TX 77484
Main: 713.861.2500 • Marketing Fax: 713.331.3275
www.northamerica‐daikin.com
Daikin Shared Data Loader User Manual
When loading Shared Data from the card onto a Daikin unit,
first turn off power to the HVAC system and insert the card
into the Shared Data loading connector on the control board
of the unit. When plugged into the unit, the card must be
powered on to function properly. A flashing blue light is an
indicator that the Bluetooth® data loader is working.
With the card plugged in, power on the HVAC system and
allow 30 seconds for the Shared Data loading process to
complete. When complete, power the equipment “off” and
retrieve the card from the unit. Turn power “on” to the
system and confirm that the Shared Data loading process was
successful, and that the system is operating normally.
Additional Notes
There are many different models of Daikin equipment offered In short, if a unit reports a d0, d1, or d2 fault code, it will be
under various platforms; however, all these models use only necessary to load Shared Data from the card.
a small handful of control boards. To make sure each control
board can work inside its intended chassis, we load each One of these fault codes may be generated by a unit after
board with a small amount of chassis‐specific data when the some parts of the equipment are replaced. After a system is
equipment is assembled. powered on for the first time, there are two or three places
where the Shared Data for the entire system is stored. Shared
When the equipment is installed, this chassis data is copied Data is always stored on the indoor unit control board and
over to any other connected communicating equipment and the indoor blower motor. If the outdoor unit is wired in
saved there in case some parts need to be replaced at a later communicating mode to the indoor unit (i.e. wired using the
date. Because this data is shared by other equipment on the 1‐2‐R‐C connector), then Shared Data for the system is also
same network, we call it “Shared Data.” stored on the outdoor control board.
This means if only one part needs to be replaced in a system, Shared Data will only need to be replaced if all sources of
it’s likely the Shared Data will automatically be loaded from Shared Data on a system are replaced at the same time.
the existing equipment. However, if multiple parts need to be
replaced all at once and the system loses all the places where Loading Shared Data can be avoided by replacing only one
this Shared Data is stored, Shared Data will need to be of these parts at a time and powering up the system after
reloaded to make sure the freshly installed parts are replacing each part.
compatible with the existing equipment.
4
DAIKIN NORTH AMERICA LLC • 19001 Kermier Road • Waller, TX 77484
Main: 713.861.2500 • Marketing Fax: 713.331.3275
www.northamerica‐daikin.com
Daikin Shared Data Loader User Manual
FCC Statement
5
DAIKIN NORTH AMERICA LLC • 19001 Kermier Road • Waller, TX 77484
Main: 713.861.2500 • Marketing Fax: 713.331.3275
www.northamerica‐daikin.com