www.airwoods.com ECO Pair Plus ERV
Features
Elegant decorative front panel.
3
ECO Pair Plus ERV www.airwoods.com
Separation Circle
Open Closed
Reversible DC Motor
The reversible axial fan is with EC technology. The fan is characterised by low power consumption and silent
operation. The fan motor has built-in thermal protection and ball bearings for long life.
4
www.airwoods.com ECO Pair Plus ERV
The ceramic regenerator is treated with an antibacterial composition to prevent bacterial growth inside.
Temperature Sensor
Ceramic Energy Regenerator
12V EC Fan
Air Filters
Two integrated air pre-filters and a F7 air filter are fitted as standard to
provide supply and extract air filtration. The filters prevent the ingress of
dust and insects into the supply air and contamination of the fan parts.
The filters are also antibacterially treated.
The filters are cleaned with a vacuum cleaner or by flushing with water.
The antibacterial solution will not be removed.
5
ECO Pair Plus ERV www.airwoods.com
Energy Saving
The ventilator is designed both for reversible mode with energy regeneration and supply or exhaust mode with no regeneration.
WHEN
The polluted warm air is IT’S COOL
In 75 seconds, when the
extracted from the room,
energy regenerator gets cold,
OUTSIDE
while passing the ceramic
WARM AIR
WARM AIR
energy regenerator, the the ventilator switches to the
recuperator will absorb the air extract mode. The cycle
heat and moisture. The filter starts from the beginning.
prevents contaminants from
entering the regenerator.
COLD AIR
Stale air extraction supply air flow will close to Clean air supply
the ventilator automatically
COLD AIR
6
www.airwoods.com ECO Pair Plus ERV
Energy Recovery
WHEN IT’S HOT OUTSIDE
The ventilator operates in the heat recovery mode with two cycles. Two units intake/exhaust air alternately at the same time to achieve
balance ventilation. It will increase the indoor comfort and make ventilation more effective. The heat and humidity in the room can be
recovered during ventilating and the load on cooling system can be reduced in summer
WHEN
The polluted cool air is In 75 seconds, when the IT’S HOT
extracted from the room, energy regenerator gets OUTSIDE
while passing the ceramic warm, the ventilator switches
energy regenerator, the to the air extract mode.
COLD AIR
COLD AIR
recuperator will absorb The cycle starts from the
the cold energy and beginning.
moisture. The filter prevents
contaminants from entering
the regenerator.
WARM AIR
CYCLE I regenerator gets cool, the and moisture so that the CYCLE II
Stale air extraction temperature of supply air Clean air supply
ventilator automatically
WARM AIR
7
ECO Pair Plus ERV www.airwoods.com
Easy Control
Button Remote Control
ON/OFF
FAN SPEED:
ON state: you can switch the fan Working Mode
speed of the unit, total 3 speeds.
ON/OFF:
Control the unit to ON/OFF state. Î Using radio signal for communication.
Î Longer distances communication up to 15m without barrier.
Î Wider control area, multiple devices can be controlled at the
same time.
WIFI Function
Î Accurate control to avoid controlling the wrong device.
Î On/off switch
Î Fan speed selection SCENE CONTROL
Î Working mode selection
User can create scene(s) according to the weather changes,
Î Pairing status schedule or the device status changes.
Î Outdoor temperature display
For example, when the weather shows the outdoor relative
Î Filter alarm
humidity is higher than 85%, user can set the ventilator to stop
Î Free-Cooling function
or run at exhaust mode, to prevent the outdoor humidity coming
Î CO2 concentration control inside. The unit will run according to the setting automatically.
Î 12 hrs timer setting
Î Optional Negative ion function
Î Indicator lights ON/OFF 85%
Î Weekly schedule
Î Fan boost function
Î Multiple linkage control Group Control
Î Smart control according to local
weather The ventilator can create group control at the APP, the quantity
Î Optional humidity control is not limited. User can control all the ventilators in the group
easily.
or
8
www.airwoods.com ECO Pair Plus ERV
* 30 meters was tested without barrier and interference. In practical application, it is recommended to install within 8-15 meters.
Please avoid strong interference sources and shielding objects (e.g. iron frames, aluminum ceiling).
9
ECO Pair Plus ERV www.airwoods.com
FREE COOLING
CO2 CONTROL
10
www.airwoods.com ECO Pair Plus ERV
Technical Parameters
Model No. AV-TTW5-W
Air flow in supply/exhaust mode (with F7 filter) (CMH/CFM)* 20/11.8 40/23.5 50/29.4
SEC Class A
Product size (mm) 239.6x258x499.7 (The length of duct in wall is 280-470 mm)
*Note: The airflow in supply/exhaust mode without F7 filter is about 34/56/70CMH or 20/33/41.2 CFM, and the relative parameters will be adjusted
accordingly.
77.2
Ø156.5
Ø226.4
Ø158
258
239.6
280~470 142.5
11
ECO Pair Plus ERV www.airwoods.com
Accessories
PICTURE ACCESSORY NAME PRODUCT CODE PICTURE ACCESSORY NAME PRODUCT CODE
Extended pipe
(Ø 160, Length390mm, AS-EDP001 Indoor unit AS-IUN001
to extend the total pipe
length to 600mm)
Cartrigde with
Ventilation hood for
AS-VHI001 regenerator, fan and two AS-CRF001
indoor mounting
filters