LX 400
LX 400
LX 400
LX-100 SERIES
■■General terms and conditions.............. F-7 ■■Sensor selection guide...................P.885~
FIBER Related Information
SENSORS ■■Glossary of terms........................ P.1455~ ■■General precautions.................... P.1458~
LASER
SENSORS
PHOTOELECTRIC
SENSORS Conforming to Recognition
EMC Directive
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS panasonic.net/id/pidsx/global PNP output Timer Automatic
type available sensitivity setting
STATIC ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
Introduction of the 3 LED mark sensor
HUMAN MACHINE
INTERFACES Can detect any mark!
ENERGY CONSUMPTION
VISUALIZATION
COMPONENTS
Coaxial reflective optics and a sharp 1 × 5 mm 0.039 4-digit digital display
× 0.197 in spot enable high precision sensing. Stable The 4-digit digital display enables
FA COMPONENTS detection of marks is possible. numerical sensing control and
minute settings.
MACHINE VISION
R•G•B light emitting Operation panel
SYSTEMS Newly 3 large buttons that click into position
developed elements all in one making operation easy.
UV CURING
SYSTEMS To detect any marking, this unit is
equipped with red, green and blueblue Highest in
light emitting
LED light emittingelements
elementsallallinin the industry
one. 12-bit A/D converter
Total reflection A resolution of 1/4,000 is realized to
High precision coaxial mirror enable high precision mark sensing.
reflective optical system Receiving element
Half mirror
Selection SUNX’s unique
Panasonic coaxial
Industrial Devicesreflective
SUNX's
Guide optics coaxial
unique technology ensures
reflective optics very Glass lens Protection IP67
Wafer Detection accurate sensing.
technology ensuresThe
veryunit is made
accurate Washing the machines and
with a scratchproof
sensing. glass with
The unit is made lens.a ▲Image schematic production line with water will
Liquid Leak
Detection scratchproof glass lens. not affect the sensor thanks
Liquid Level to its waterproof construction.
Detection
Spot size 1 × 5 mm
Water Detection
0.039 × 0.197 in approx.
Color Mark
Detection
Hot Melt Glue
Automatic optimal LED selection function
Detection
Ultrasonic The 3 colors of the R•G•B LEDs are Example: A packing film
Small / optimally selected according to the color
Slim Object Detection combination. With the LX-100’s Mark mode,
Obstacle
Detection the built-in “Automatic optimal LED selection
Other Products function” automatically selects the LED for
the largest contrast (S / N ratio) between the
mark and base (non-mark area) to ensure
LX-100 optimal sensing. For more stable detection,
the sensor makes selection according to the Optimal
Reflective light
Reflective light
Reflective light
FZ-10
contrast and not according to the reflected
light variation between the mark and base
(non-mark area).
The example on the right deals with reflected light
on packing film. Mark Base Mark Base Mark Base
Great figures are indicated for the blue LED’s light
amount ratio and, for even more stable sensing,
Light amount
ratio = 6 : 8 Light amount
ratio = 8 : 4 Light amount
ratio = 4 : 1
the blue LED effectuates this mark sensing.
Digital Mark Sensor LX-100 SERIES
930
Two detection modes can be selected from to suit the application FIBER
SENSORS
SENSOR
OPTIONS
the area of the mark. The color around letters is STATIC ELECTRICITY
detected as a mark. PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN MACHINE
INTERFACES
ENERGY CONSUMPTION
VISUALIZATION
COMPONENTS
FA COMPONENTS
MACHINE VISION
Predetermined colors are SYSTEMS
detected as marks. UV CURING
SYSTEMS
* You can select the mark mode or color mode through key operation.
LX-100
Mark
FZ-10
Even similar colors are accurately determined using the R•G•B ratio. 13 : 10 : 5 15 : 10 : 5 15 : 10 : 6
931 Digital Mark Sensor LX-100 SERIES
FIBER Its digital display makes settings easy! Numerical control of the settings is possible
SENSORS
LASER The 4-digit digital display enables easy verification of received light from marks and base (non-mark area). Also, the
SENSORS threshold value can be controlled numerically enabling setting indication easily. Displaying the direct code enables
PHOTOELECTRIC
settings verification. This function is handy for remote maintenance.
SENSORS
MICRO MODE indicator 4-digit digital display
PHOTOELECTRIC
SENSORS ( Light-receiving
setting values are displayed. )
amount and
AREA
SENSORS
Operation indicator MODE indicator
LIGHT CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
MODE key
INDUCTIVE OFF key
PROXIMITY (PRO mode: CANCEL key)
(PRO mode: ENTER key)
SENSORS
PARTICULAR
USE SENSORS
ON key
SENSOR (PRO mode: SELECT key)
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
Even beginners can quickly master MODE NAVI operation
WIRE-SAVING The sensor’s basic operations are represented by 6 indicators (MODE NAVI). The user can check what mode the
SYSTEMS
sensor is presently in with a quick glance making operation simple.
MEASUREMENT
SENSORS
STATIC ELECTRICITY This is the sensing mode. The digital display
PREVENTION This mode enables a mark
DEVICES
shows the light-receiving amount (mark mode) RUN COLOR mode / color mode selection.
and the color consistency (color mode).
LASER
MARKERS
This is the threshold value
PLC
setting (teaching) mode. TEACH TIMER Timer type selection mode.
HUMAN MACHINE
INTERFACES
This mode enables the setting
ENERGY CONSUMPTION This is the threshold
VISUALIZATION fine-adjustment mode. ADJ PRO of various functions such as
COMPONENTS key lock and timer period.
FA COMPONENTS
MACHINE VISION
Sensing status digitally controllable
SYSTEMS
The sensing status, displayed • Example of sensor setting indication
UV CURING numerically, can be verified at a
SYSTEMS
glance. Also, the sensor settings
for each type of packing film can be
digitally indicated.
■ Selected LED: Red LED ■ Selected LED: Green LED ■ Selected LED: Blue LED
■ Threshold value: 600 ■ Threshold value: 1850 ■ Threshold value: 1600
Selection
Guide
Wafer Detection Direct codes enable settings verification at a glance
Liquid Leak
Detection The settings for the LX-100 series sensors are displayed using a 4-digit direct code. Direct codes enable easy setting
Liquid Level
Detection verification and maintenance by phone.
Water Detection
Color Mark
Detection
Hot Melt Glue What is the The direct code is 0004. At present,
Detection direct code? the sensor is operating with a mark
Ultrasonic at 2300 and base at 860.
Small /
Slim Object Detection
Obstacle
Detection
Other Products
LX-100
FZ-10
Digital Mark Sensor LX-100 SERIES
932
L-ON
COARSE
FINE
ON
(
Threshold value
adjustment only enabled) OFF-delay
ON-delay
200 ms
500 ms
SENSORS
INDUCTIVE
COARSE PROXIMITY
Mark mode (red) SENSORS
FINE
D-ON
COARSE PARTICULAR
FINE USE SENSORS
Consistent-ON
COARSE
Color mode SENSOR
FINE
Inconsistent-ON OPTIONS
COARSE
SIMPLE
Notes: 1) In Mark mode, L-ON / D-ON is automatically set in the sensor. For example, with 2-level teaching, press the ON key at the targeted mark and WIRE-SAVING
press the OFF key at the base (non-mark area). When doing so, the operator does not have to consider L-ON / D-ON. UNITS
2) Sensing accuracy can be set to either FINE (standard) or COARSE.
WIRE-SAVING
3) The percent display is only enabled in mark mode. SYSTEMS
4) ECO mode is a function that reduces power consumption by turning off the digital display in the event that no button operations are made for
a predetermined time (approx. 10 sec. or more) in RUN mode. Press any button to turn the digital display on again. MEASUREMENT
5) The turn mode is a function that reverses the digital display making it easily to be viewed in the event that the sensor installation renders the display up-side-down. SENSORS
* Default setting: D-code = “ ”. STATIC ELECTRICITY
PREVENTION
DEVICES
Super simple teaching LASER
MARKERS
Press the ON button at the targeted mark. External teaching possible
PLC
Here is an example of the most basic setting method Teaching is possible through external input using an
“2-level teaching”. operation panel or touch panel even on hard-to-reach HUMAN MACHINE
color mark sensors located inside an equipment. Also, INTERFACES
models can be interchanged easily. ENERGY CONSUMPTION
Mode selection Press MODE key and select TEACH mode. VISUALIZATION
COMPONENTS
Display showing
complete settings
Selection
Teaching complete. The optimal LED is Guide
Sensing automatically selected and the sensor Wafer Detection
automatically returns to RUN mode.
Liquid Leak
Detection
Other teaching methods Liquid Level
Detection
• Full-auto teaching: In Mark mode, teaching is effective Water Detection
without stopping the sensing object. Color Mark
Detection
• 1-level teaching: In Color mode, the color detected is aligned Hot Melt Glue
by the spot and teaching is effective. Detection
Ultrasonic
Small /
Compact design for significant space savings Key lock function Slim Object Detection
Obstacle
Detection
High precision sensing and multiple functions are all The key lock function enables input operation control Other Products
packed in a compact W57 × D24 × H38 mm W2.244 that prevents mistaken changes in the sensor settings.
× D0.945 × H1.496 in body. Other detailed settings include “RUN adjust”, allowing
Cable and plug-in connector threshold value adjustment only, and “RUN teaching”, LX-100
types are available allowing teaching operation only. FZ-10
depending on the If the sensor is set to “RUN adjust” or “RUN teaching”,
equipment used. adjustment and teaching are possible having the sensor
These sensors can remained in RUN mode.
be easily introduced 38 mm
1.496 in
to existing facilities.
57 mm
24 mm 2.244 in
0.945 in
933 Digital Mark Sensor LX-100 SERIES
FIBER
SENSORS
ORDER GUIDE
LASER
SENSORS Sensors Mating cable is not supplied with the plug-in connector type. Please order it separately.
PHOTO-
ELECTRIC
SENSORS Type Appearance Model No. Output Sensing range
MICRO
PHOTO-
ELECTRIC
SENSORS
LX-101 NPN open-collector transistor
Cable type
AREA
SENSORS
LIGHT
CURTAINS /
LX-101-P PNP open-collector transistor
SAFETY
COMPONENTS 10 ±3 mm 0.394 ±0.118 in
PRESSURE /
LX-101-Z NPN open-collector transistor
connector
FLOW
SENSORS
Plug-in
type
INDUCTIVE
PROXIMITY
SENSORS
LX-101-P-Z PNP open-collector transistor
PARTICULAR
USE
SENSORS
Mating cables for plug-in connector type sensor Mating cable is not supplied with the plug-in connector type sensor. Please order it separately.
SENSOR
OPTIONS Mating cables for plug-in connector
SIMPLE Type Model No. Description type sensor
WIRE-SAVING
UNITS • CN-24B-C2 • CN-24BL-C2
• CN-24B-C5 • CN-24BL-C5
WIRE-SAVING
SYSTEMS
CN-24B-C2 Length: 2 m 6.562 ft
Straight
MEASURE- ø14 mm ø5 mm
MENT
SENSORS CN-24B-C5 Length: 5 m 16.404 ft ø0.551 in ø0.197 in
0.34 mm2 4-core cabtyre cable, with
STATIC connector on one end
ELECTRICITY
PREVENTION Cable outer diameter: ø5 mm ø0.197 in
DEVICES CN-24BL-C2 Length: 2 m 6.562 ft 43.5 mm ø5 mm ø14 mm
1.713 in ø0.197 in ø0.551 in
LASER Elbow
MARKERS
CN-24BL-C5 Length: 5 m 16.404 ft
31 mm
PLC 1.220 in
HUMAN
MACHINE 29 mm
INTERFACES 1.142 in
ENERGY
CONSUMPTION
VISUALIZATION
OPTIONS
COMPONENTS
FA
COMPONENTS
UV
CURING MS-LX-1
SYSTEMS Sensor
Mounting bracket made for LX-100 series applicable for
mounting
various kinds of installations
bracket
MS-LX-2
LX-100
FZ-10
Digital Mark Sensor LX-100 SERIES
934
SPECIFICATIONS FIBER
SENSORS
LASER
SENSORS
Type Cable type Plug-in connector type
PHOTO-
Model No.
Output operation Mark mode: Light-ON / Dark-ON (Auto-setting on teaching), Color mode: Consistent-ON / Inconsistent-ON (Setting on teaching) MEASURE-
MENT
SENSORS
<NPN output type> STATIC
NPN open-collector transistor ELECTRICITY
PREVENTION
• Maximum sink current: 50 mA DEVICES
• Applied voltage: 30 V DC or less (between output and 0 V) LASER
Output 2 • Residual voltage: 1.5 V or less (at 50 mA sink current) – MARKERS
(OUT) <PNP output type>
PNP open-collector transistor PLC
• Maximum source current: 50 mA
• Applied voltage: 30 V DC or less (between output and +V) HUMAN
• Residual voltage: 1.5 V or less (at 50 mA source current) MACHINE
INTERFACES
ENERGY
Short-circuit protection Incorporated – CONSUMPTION
VISUALIZATION
COMPONENTS
Output operation Inverted operation of the output 1 –
FA
COMPONENTS
Response time Mark mode: 45 µs or less, Color mode: 150 µs or less
MACHINE
VISION
<NPN output type> <PNP output type> SYSTEMS
NPN non-contact input PNP non-contact input
UV
• Signal condition: High… +5 V to +V, or open • Signal condition: High… +4 V to +V CURING
Teaching input
Low… 0 to +2 V (sink current: 3 mA or less) SYSTEMS
(source current: 0.5 mA or less) Low… 0 to +0.6 V, or open
• Input impedance: 10 kΩ approx. • Input impedance: 10 kΩ approx.
Sensitivity setting Mark mode: 2-level teaching / Full-auto teaching, Color mode: 1-level teaching
Selection
Fine sensitivity adjustment function Incorporated Guide
Wafer
Timer function Incorporated with variable ON-delay / OFF-delay timer, switchable either effective or ineffective (Timer period: 1 to 500 ms, 9 levels variable) Detection
Liquid Leak
Protection IP67 (IEC) Detection
Environmental resistance
Liquid Level
Ambient temperature –10 to +55 °C +14 to +131 °F (No dew condensation or icing allowed), Storage: –20 to +70 °C –4 to +158 °F Detection
Water
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH Detection
Color Mark
Detection
Ambient illuminance Incandescent light: 3,000 ℓx at the light-receiving face
Hot Melt Glue
Detection
Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure
Ultrasonic
Vibration resistance 10 to 500 Hz frequency, 3.0 mm 0.118 in amplitude (max. 20 G) in X, Y and Z directions for two hours each Small / Slim
Object Detection
Shock resistance 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions for three times each Obstacle
Detection
Emitting element Combined Red / Green / Blue LEDs (Peak emission wavelength: 640 nm 0.025 mil / 525 nm 0.021 mil / 470 nm 0.019 mil) Other
Products
Material Enclosure: PBT, Display cover: Polycarbonate, Operation buttons: Silicone rubber, Lens: Glass, Lens holder: Aluminum
Cable 0.34 mm2 5-core cabtyre cable, 2 m 6.562 ft long (Note 2) LX-100
Cable extension Extension up to total 100 m 328.084 ft is possible with 0.3 mm , or more, cable.
2
FZ-10
Weight Net weight: 120 g approx., Gross weight: 180 g approx. Net weight: 55 g approx., Gross weight: 120 g approx.
FIBER
SENSORS
I/O CIRCUIT AND WIRING DIAGRAMS
LASER
SENSORS LX-101(-Z) NPN output type LX-101-P(-Z) PNP output type
PHOTO-
ELECTRIC I/O circuit diagram I/O circuit diagram
SENSORS
Terminal No. of plug-in connector type Color code of cable type / Terminal No. of plug-in connector type Color code of cable type /
MICRO mating cable for plug-in connector type mating cable for plug-in connector type
PHOTO-
ELECTRIC
SENSORS D1 (Brown) +V (Brown) +V
1 1
AREA Load 10 kΩ D2 (Pink) Teaching input
SENSORS Tr1 (Black) Output 1 2
4 Load *1
Sensor circuit
Sensor circuit
0V ZD1 ZD2
LIGHT
CURTAINS / Tr2 (White) Output 2 (Note 2) 50 mA max. (Note 1) + 50 mA max. (Note 1) +
12 to 24 V DC 12 to 24 V DC
SAFETY ±10 % ±10 %
COMPONENTS 50 mA max. (Note 1) – Tr1 4 –
ZD2 ZD1 (Black) Output 1 50 mA max. (Note 1)
+5 V
PRESSURE /
FLOW 10 kΩ D2 (Pink) Teaching input Tr2 Load
SENSORS 2 (White) Output 2 (Note 2) Load
(Blue) 0 V *1 D1
INDUCTIVE 3 3
PROXIMITY (Blue) 0 V
SENSORS
Internal circuit Users’ circuit Internal circuit Users’ circuit
PARTICULAR
USE Notes: 1) The current of the plug-in connector type LX-101-Z is 100 mA max. Notes: 1) The current of the plug-in connector type LX-101-P-Z is 100 mA max.
SENSORS
2) The output 2 is not incorporated to the plug-in connector type LX-101-Z. 2) The output 2 is not incorporated to the plug-in connector type LX-101-P-Z.
SENSOR *1 *1
OPTIONS
PLC
Connector pin layout of plug-in connector type
HUMAN
MACHINE
INTERFACES
ENERGY Connector pin No. Description
CONSUMPTION
VISUALIZATION 1 +V
COMPONENTS
FA 2 Teaching input
COMPONENTS
3 0V
MACHINE
VISION
SYSTEMS 4 Output
UV
CURING
SYSTEMS
SPOT SIZE CHARACTERISTICS (TYPICAL)
(Unit: mm in)
LX-100
FZ-10
Digital Mark Sensor LX-100 SERIES
936
PRECAUTIONS FOR PROPER USE Refer to p.1458~ for general precautions. FIBER
SENSORS
LASER
Others SENSORS
• Never use this product as a sensing device
for personnel protection. • Do not use during the initial transient time (0.5 sec.) after PHOTO-
ELECTRIC
• In case of using sensing devices for the power supply is switched on. SENSORS
MICRO
personnel protection, use products which • Take care that the sensor is not directly exposed to PHOTO-
ELECTRIC
meet laws and standards, such as OSHA, fluorescent light from a rapid-starter lamp or a high SENSORS
ANSI or IEC etc., for personnel protection frequency light device or sunlight etc., as it may affect the AREA
applicable in each region or country. sensing performance. SENSORS
LIGHT
• Do not touch the lens of the sensor by hand directly. If CURTAINS /
SAFETY
Mounting the lens becomes dirty, wipe it off with a soft cloth gently. COMPONENTS
• Care must be taken regarding the sensor mounting • When the inside lens is steamed up, unscrew the lens to PRESSURE /
FLOW
direction with respect to the object’s direction of movement. get rid of the condensation. SENSORS
because it may cause • Take care that the product does not come in contact with SENSOR
unstable operation. water, oil, grease, or organic solvents, such as, thinner, OPTIONS
specular reflection particles that may destabilize sensing. • Never disassemble or modify the sensor. STATIC
ELECTRICITY
PREVENTION
In such a case, by slightly tilting the sensor’s beam axis, DEVICES
this specular reflection can be reduced rendering sensing LASER
more stable. MARKERS
LX-100
FZ-10
937 Digital Mark Sensor LX-100 SERIES
FIBER
SENSORS
LIST OF PROMODE SETTING ITEMS
LASER
SENSORS
• Before performing teaching or each detail setting, perform the setting of
PHOTO-
ELECTRIC either mark mode or color mode with mark / color mode setting of NAVI
SENSORS
MICRO
mode.
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS NAVImode PROmode • For selecting a setting item, press 'ON key'. For confirming each selected setting item,
LIGHT
press 'OFF / ENTER key'. After confirming setting, the digital display flashes.
CURTAINS / RUN Run For canceling setting, press 'MODE key'.
SAFETY OFF
COMPONENTS At mark mode setting:
Indicates the absolute value Press OFF
PRESSURE /
FLOW of emitting amount. It is Sensing setting ENTER Press
SENSORS SELECT
possible to indicate the Sets the sensing level
INDUCTIVE relative value (percent value) (hysteresis.)
PROXIMITY against threshold value. Sensing level: Fine Sensing level: Coarse
SENSORS
At color mode setting:
PARTICULAR Indicates color matching
USE degree with relative value.
SENSORS
(20ms) (50ms) (100ms) (200ms) (500ms)
Timer setting
SENSOR Press
OPTIONS Sets timer setting period by
TEACH Teaching 9-steps.
SIMPLE
WIRE-SAVING At mark mode setting:
UNITS Sets the threshold value by
'2-level teaching' or 'full-auto (10ms) (5ms) (2ms) (1ms)
WIRE-SAVING teaching'.
SYSTEMS Key lock setting
At color mode setting:
Selects key lock function. Set full key lock.
MEASURE- Sets the threshold value by
MENT '1-level teaching'. Set key lock except
SENSORS for RUN teaching mode.
STATIC Set key lock except (RUN teaching)
ELECTRICITY for RUN adjust
PREVENTION OFF
DEVICES mode.(RUN adjust)
ADJ Adjust Press
Display setting
LASER At mark mode setting: ENTER
MARKERS Selects display method of
Allows fine adjustment of
the threshold value. digital desplay.
Mark mode setting: Displays incident light intesity Mark mode setting: Displays relative value (percentage)
PLC At color mode setting: Color mode setting: Displays color coincidence Color mode setting: Displays color coincidence
Allows adjustment of sensing
HUMAN tolerance value.
MACHINE
INTERFACES Eco setting
ENERGY Sets ON / OFF of eco mode.
CONSUMPTION
VISUALIZATION
COLOR Mark / Color mode setting
COMPONENTS
Eco setting: OFF Eco setting: ON
Sets mark mode or color
FA mode.
COMPONENTS
LX-100
FZ-10
Digital Mark Sensor LX-100 SERIES
938
DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from our website. FIBER
SENSORS
LASER
LX-101 LX-101-P Sensor LX-101-Z LX-101-P-Z Sensor SENSORS
PHOTO-
ELECTRIC
SENSORS
RUN COLOR RUN COLOR
TEACH TIMER TEACH TIMER
ADJ PRO ADJ PRO
24 OPE.
TEACH
24 OPE.
TEACH MICRO
0.945 0.945 PHOTO-
MODE ON OFF MODE ON OFF
ELECTRIC
CANCEL SELECT ENTER CANCEL SELECT ENTER SENSORS
71.5 AREA
SENSORS
2.815
57 57
1.5 2.244 1.5 ø14.4 LIGHT
0.059 0.059 2.244 CURTAINS /
5 47 5 47 ø0.567 SAFETY
0.197 1.850 0.197 1.850 COMPONENTS
9.4 PRESSURE /
FLOW
0.370 SENSORS
35 25 INDUCTIVE
35 25 PROXIMITY
1.378 0.984 1.378 0.984 SENSORS
PARTICULAR
M12 USE
SENSORS
5 5
( )
2-ø4.5 ø0.177 2-ø4.5 ø0.177
( )
ø22 ø22 SENSOR
0.197 3 ø0.866 mounting holes 0.197 3 ø0.866 mounting holes OPTIONS
0.118 15 0.118 15
0.591 0.591 SIMPLE
WIRE-SAVING
UNITS
MS-LX-1 Sensor mounting bracket (Optional) MS-LX-2 Sensor mounting bracket (Optional) WIRE-SAVING
SYSTEMS
3 80
0.118 3.150 MEASURE-
20 3 MENT
R2 R0.079 0.118 SENSORS
0.787
STATIC
ELECTRICITY
39 28 PREVENTION
1.535 1.102 R2 DEVICES
27 30.4 R0.079 4 6
1.197 21 0.157 27.2 LASER
1.063 0.236 3-M5 × 0.8 0.031 1.071 MARKERS
15 0.827
4-R2 R0.079 0.591
2-M5 × 0.8 0.031
PLC
9 28 R4.7 R0.185
2-R4.7 1.102
R0.185 0.354
41 HUMAN
1.614 MACHINE
2-R5 R0.197 60 INTERFACES
2.362 15 3-R2 R0.079 ENERGY
0.591 CONSUMPTION
57 47 VISUALIZATION
2.244 1.850 COMPONENTS
2-R5 R0.197 45
40 1.772 FA
25
0.984 30 1.575 COMPONENTS
1.181
15 2-M4 × 0.7 0.028 MACHINE
0.591 57.2 47 57 VISION
2.252 SYSTEMS
1.850 2.244
25 2-R5 4 UV
5 10 R0.197 CURING
5 0.984 0.157
0.197 47 0.394 R2 R0.079 SYSTEMS
0.197
1.850 4-M4 × 0.7 0.028
57
2.244
72
2.835 25 5
6 5
0.984
Material: Stainless steel (SUS) 0.236 0.197 0.197
Two M4 (length 28 mm 1.102 in) screws with washers are attached. Material: Stainless steel (SUS)
Two M4 (length 30 mm 1.181 in) screws with washers are attached. Selection
Guide
Wafer
Detection
Liquid Leak
Detection
Liquid Level
Detection
Water
Detection
Color Mark
Detection
Hot Melt Glue
Detection
Ultrasonic
Small / Slim
Object Detection
Obstacle
Detection
Other
Products
LX-100
FZ-10