Manufacturers of Florida LLC

WAVE TILE METAL ROOF PANEL

Product Information & Installation Manual

Version 1.0 - EN-US 2023


COLOPHON

Address and Phone number:


Postal address:
942 Blanche St, Building #3,
Jacksonville, FL 32204, United States

Business hours:
Monday-Friday 7:00 am - 4:00 pm

Internet address:
www.elitesteelflorida.com

E-mail address:
[email protected]

Phone:
(904) 799-6499

Manual info:

The original instructions for this product are provided in the English language and
binding. This manual may not be copied, translated, or otherwise reproduced without the
permission of Elite Steel Manufacturers of Florida LLC.

History of changes:
Installation Manual Version: Date: Chapters: Description:
V1.0 March 2023 All First edition

Product Information & Installation Manual - Page 2 of 32 - ES Wave Tile Roof Panel V1.0
Table of contents

1 PREFACE ............................................................................................................................... 4
1.1 IDENTIFICATION ............................................................................................................ 4
2 INTRODUCTION ..................................................................................................................... 5
3 SAFETY .................................................................................................................................. 6
3.1 Safety Warning Messages in this Manual......................................................................... 6
3.2 General Safety Rules for Roof Panel Installation.............................................................. 7
3.3 Handling Panels ............................................................................................................... 8
3.3.1 Blocking and Banding............................................................................................... 8
4 WAVE TILE PANEL OVERVIEW ............................................................................................. 9
5 ROOF DECKING PREPARATION......................................................................................... 10
6 FASTENERS FOR WAVE TILE ROOF PANELS ................................................................... 11
7 FIELD CUTTING ................................................................................................................... 12
8 FASTENING PATTERNS ...................................................................................................... 13
8.1 Fastening Pattern for NON-HVHZ Construction ............................................................. 13
8.2 Fastening Pattern for HVHZ Construction ...................................................................... 14
9 INSTALLATION ..................................................................................................................... 15
10 WAVE TILE FLASHING DETAILS ..................................................................................... 16
10.1 Eave Drip Detail ............................................................................................................. 17
10.2 High Eave Trim Detail .................................................................................................... 18
10.3 Valley Flashing Detail .................................................................................................... 19
10.4 Rake Trim W/ Starter Detail ........................................................................................... 20
10.5 Sidewall Trim Detail ....................................................................................................... 21
10.6 Endwall Trim Flashing Detail .......................................................................................... 22
10.7 Endwall Reglet Flashing Detail....................................................................................... 23
10.8 Counter Flashing Detail.................................................................................................. 23
10.9 Rolled Ridge Cap Detail ................................................................................................. 24
10.10 Ridge Ventilation Detail .............................................................................................. 25
10.11 Step Ridge Cap Detail ................................................................................................ 25
10.12 Formed Ridge Cap Detail ........................................................................................... 26
10.13 Hip-to-Ridge Connection Detail .................................................................................. 27
10.14 Hip Cap Detail ............................................................................................................ 28
11 PIPE BOOT FITTINGS ...................................................................................................... 29
12 CHIMNEY AND SKYLIGHT FLASHING DETAIL ............................................................... 30
13 HELPFUL HINTS ............................................................................................................... 31

Product Information & Installation Manual - Page 3 of 32 - ES Wave Tile Roof Panel V1.0
1 PREFACE
Installation manual for Elite Steel Manufacturers of Florida, LLC Wave Tile Panel.

This installation manual is the latest, most up-to-date resource on best practices. We
provide information, tips and suggestions in this way based on data and knowledge,
however these instructions are not a substitute for expert professional advice.

 This manual contains information about product installation and application. The
drawings in this manual are for illustration purposes only and may not apply to your
specific product installation or building design.
 All projects need to conform to applicable building codes for the area in which they are
being constructed. It is recommended to follow all building regulations and standard
industry practices.
 Elite Steel Manufacturers of Florida LLC cannot be responsible for the roof system's
performance, nor can we assume liability if not installed following the suggested
instructions referenced in this manual.
 It is important to verify all the dimensions by field measurements before ordering and
installing materials.
 Please direct any questions regarding the installation of Wave Tile roofing systems to
your representative.
 This manual is suitable for installing the Wave Tile roofing system by Elite Steel
Manufacturers of Florida LLC. Consult your representative for any additional
information not outlined in this manual.
 The installer is responsible for ensuring the safe installation of this product system
according to all guidelines, codes, and regulations of their local building code.

1.1 IDENTIFICATION
Elite Steel Manufacturers of Florida LLC roof tile panels differ from traditional roof tiles in
many aspects. Longer lifespan, lightweight, storm resistant, and straightforward
installation are just a few unique aspects of these roof tile panels. You can choose from
different metal profiles; all profiles are available in various panel lengths and color choices.
All the roof facets combine to create a guaranteed optimal match to any architectural style
or personal preference. It is a product for years of carefree maintenance.

Metal roof panels provide several benefits that make them a great choice for any home or
business. Some of the benefits include:
 Durability:
Metal roof panels can last decades and resist weather, pests, and fire damage.

Product Information & Installation Manual - Page 4 of 32 - ES Wave Tile Roof Panel V1.0
 Energy Efficiency:
Metal roofs reflect the sun's ultraviolet rays, which can help keep a building cooler and
reduce energy costs.
 Low Maintenance:
Metal roofs are extremely durable and require very little maintenance. This durable
material can last for years without needing to be replaced like other types of roofing
materials.
 Sustainability:
Metal roof panels are often made from recycled materials and are fully recyclable at the
end of their useful life.
 Design Flexibility:
Our metal roof panels come in various styles and colors, making matching any
architectural style or personal preference effortless.

Other benefits are:


 Custom ordered to size.
 Resistant to most weather conditions.
 Simple assembly and larger panel coverages reduce the installation time.

2 INTRODUCTION
You must read this manual before installing the Wave Tile roof panels. The Wave Tile
installation manual will help you understand and appreciate your roof panels. Reading
this manual and understanding the Safety and Maintenance instructions will give you
better performance and extend the life of your roof panels.

Using This Manual


This Installation Manual is designed to help familiarize you with Safety, Adjustments,
Maintenance and Troubleshooting. The information contained within this manual was
current at the time of printing. Please check for updates at our website at
http://www.elitesteelflorida.com/ or call to speak with one of our representatives.

Product Information & Installation Manual - Page 5 of 32 - ES Wave Tile Roof Panel V1.0
3 SAFETY
WARNING!
• Before installing or adjusting, be sure to read and understand all safety
measures and warnings.
• It is important that untrained people who have not thoroughly read and
understood this manual should not participate in the installation
process.

3.1 Safety Warning Messages in this Manual


It is very important to carefully read this manual before installing the roof panels. If there
is something in this manual you don’t fully understand, please speak with one of our
representatives.
 After reading the installation manual, store it in a safe place, easily accessible for roof
technicians.
 Improper handling of the roof panels can result in injury or physical damage.
 The manufacturer assumes no responsibility for any damage caused by mishandling
the product beyond the standard working method defined in this Installation manual.

DANGER!

• This symbol indicates a potentially and imminently hazardous situation


that, if not avoided, will result in death or severe injury.
This RED symbol indicates All DANGER notifications.

WARNING!
• This symbol indicates a potentially hazardous situation that, if not
avoided, could result in death or severe injury, or material damage.
This ORANGE symbol indicates All WARNING notifications.

CAUTION!
• This symbol indicates a potentially hazardous situation that, if not
avoided, may result in minor or moderate injury.
This YELLOW symbol indicates All CAUTION notifications.

NOTICE:

Product Information & Installation Manual - Page 6 of 32 - ES Wave Tile Roof Panel V1.0
• This Notice symbol shows special procedures or points out essential
facts.

3.2 General Safety Rules for Roof Panel Installation


 Always use extreme caution on a roof, wear gloves, and safety glasses to avoid injury.
 Wear soft-soled shoes to improve traction and minimize damage to the paint finish.
 Ensure the work area is smooth, clean, and free from any obstacles.
 Never stand or walk on any part of a roof panel until it is completely secured.
 Metal panels are slippery when wet, dusty, frosty, or oily. Do not attempt to walk on a
metal roof under these conditions. Always use OSHA-recommended safety harnesses
or equipment when working on a roof.
 Ensure that all hoisting equipment, such as lifting straps, hooks, or ropes, are in good
working condition and are suitable for their intended purpose.
 Always use tools that are in a good working condition. Ensure you know how to use
the tools before doing any work.
 Always be aware of your position on the roof relative to any roof openings, roof edges,
co-workers, and penetrations.
 Oil Canning is defined as the perceived waviness of a metal panel and is an inherent
characteristic of light-gauge, cold-rolled flat metal products. In other words, it’s a visual
phenomenon that makes metal panels look wavy or somewhat distorted, especially in a
metal roof system's broad, flat areas. Improper moving, twisting, and handing of panels
can allow for more oil canning opportunities.

Storage:
 Always inspect panels for moisture accumulation. If moisture has formed, the panels
should be unbundled, wiped dry, and allowed to dry completely. Once dry, carefully
restack the panels and loosely cover them, allowing for ample air circulation.
 Bundled sheets should be stored high enough off the ground to allow air circulation
and prevent contact with accumulating water.
 We recommend covering the bundle with a tarp.
 It is important not to use tightly wrapped plastic as a cover for the bundle as it can
delay necessary ventilation and retain heat and moisture, accelerating metal corrosion.
 It is not recommended to store the panels in a bundle for extended periods of time.
 Under no circumstances, should you store the panels near or where they encounter salt
water, corrosive chemicals, ash, or fumes released inside the building or from nearby
factories such as foundries, rolling mills, and fertilizer kilns.

Product Information & Installation Manual - Page 7 of 32 - ES Wave Tile Roof Panel V1.0
3.3 Handling Panels

WARNING!
• Improper loading/unloading of bundles and crates may result in bodily
harm and/or material damage. Elite Steel Manufacturers of Florida LLC
assumes no liability for personal injuries and material damages resulting
from improper handling of materials.

 Never pick up long panels horizontally at their ends.


 Lift panels at the edge when moving.
 Avoid dragging panels, it will cause scratching and scouring to the coated surface.
 Depending on the panel size, two or more persons should handle the panels.

3.3.1 Blocking And Banding


Elite Steel Manufacturers of Florida LLC utilizes this method for standard packaging of
roofing panels. Panels are stacked on a wooden skid and protected with a cover sheet,
then banded around the wooden skid to hold the panels tightly in place.

Product Information & Installation Manual - Page 8 of 32 - ES Wave Tile Roof Panel V1.0
4 WAVE TILE PANEL OVERVIEW
Elite Steel Manufacturers of Florida LLC Wave Tile panel is designed to create a curved,
wave-like shape when installed on a roof. The curved shape of the Wave Tile panel allows
water to flow easily off the roof.

Slope:
The minimum recommended slope for Wave Tile panel is 3:12.

Substrate
Typical roof sheathing from Elite Steel Wave Tile panels can be installed over include
7/16” OSB, ½” Plywood, 5/8” Plywood and 3/4” Plywood.

Width Coverage
Each panel has a width coverage of 39 11/16”.

Length
 The minimum factory cut length is 2'- 0".
 Maximum panel length is 46'- 0".
 Lengths between 2'- 0" and 46'- 0" will be cut at 6" increments.

Application
Wave Tile panels are installed vertically from the eave to the ridge and from left to right.
You should always walk in the valley of a panel where a step is located, not the rib and
always wear soft-soled shoes.

Fasteners
Please refer to the paragraph ‘Fasteners’ in this Manual for choosing proper fasteners for
specific applications.
 The quantity and type of fastener must meet the necessary loading and code
requirements.

Materials
Elite Steel Manufacturers of Florida LLC Wave Tile panels are manufactured with 24ga,
26ga, 29ga, and .032 Aluminium.

Finishes
Elite Steel Manufacturers of Florida LLC Wave Tile panels are available in limited
Fluorocarbon (PVF2) finishes. It stands for Polyvinylidene fluoride and is a thermoplastic
fluoropolymer. The coating is an acrylic resin. It meets the specifications of the Kynar 500
and Hylar 5000. Also offered is SMP finishes. SMP stands for ‘Siliconized Modified
Polyester,’ a type of paint used on metal roofs to protect them from the elements. SMP
coatings are made by combining polyester resin with silicone, which creates a durable and
weather-resistant finish.

Product Information & Installation Manual - Page 9 of 32 - ES Wave Tile Roof Panel V1.0
Wave Tile Isometric picture with dimensions

5 ROOF DECKING PREPARATION


Before installing Wave Tile panels, it's essential to prepare your roof deck properly to
ensure that the metal panels will be installed correctly. To ensure that you are following
proper installation guidelines, remove all old roofing materials and inspect the roof deck
for any damages or protruding fasteners that would hinder the proper installation of new
metal panels. Ensure all roof surfaces are clean, level, and free of imperfections. Please
make sure the roof deck complies with your local building codes.

Product Information & Installation Manual - Page 10 of 32 - ES Wave Tile Roof Panel V1.0
6 FASTENERS FOR WAVE TILE PANELS
I M P O R T A N T W A RN I N G S !
• RECOMMENDED TOOL TYPE - Use a depth-locating nose or adjustable
clutch on the screw gun to prevent over-drilling and striping.
• ALL FASTENERS MUST BE INSTALLED STRAIGHT, NOT AT AN ANGLE.
• SEATING THE WASHER - Apply sufficient torque to seat the washer - do
not overdrive the fastener.
• TO PREVENT WOBBLING - Ensure the fastener head is fully engaged in
the socket.
• Metal shavings may build up from drilling and should be removed
occasionally.

CORRECT TOO LOOSE TOO TIGHT


The sealing material is slightly The sealing material is not visible; Metal washer deformed; sealing
visible at the edge of the metal not enough compression to seal material pressed beyond washer
washer. correctly. edge.
The assembly is watertight.

Product Information & Installation Manual - Page 11 of 32 - ES Wave Tile Roof Panel V1.0
7 FIELD CUTTING
W A R N I N G S!
• All surfaces should be free of debris.
• Installed surfaces should be wiped clean at the end of each work period.
• Never cut panels over metal surfaces.
• Metal shavings will rust on the surface, voiding the warranty.

When cutting or trimming panels, we recommend using a large metal hand shears,
power shears, or nibblers.
 To avoid damage to the paint and zinc coatings, never use abrasive metal discs under
any circumstances. These types of cutting tools produce heat which could cause the
paint and zinc coatings to lose adhesion.
 Please be advised that raw metal shavings will oxidize and rust on the paint coating
causing permanent damage. This is not covered by the paint warranty.

Product Information & Installation Manual - Page 12 of 32 - ES Wave Tile Roof Panel V1.0
8 FASTENING PATTERNS
8.1 Fastening Pattern for NON-HVHZ Construction

Product Information & Installation Manual - Page 13 of 32 - ES Wave Tile Roof Panel V1.0
8.2 Fastening Pattern for HVHZ Construction

Product Information & Installation Manual - Page 14 of 32 - ES Wave Tile Roof Panel V1.0
9 INSTALLATION
Before installing the Wave Tile panel, the eave drip and valley flashings must be installed.
The Elite Steel Wave Tile panel has exposed fasteners that has a coverage width of 39
11/16 inches and can be custom cut to lengths ranging from 2 to 46 feet. Panels longer than
46 feet require additional consideration in packaging, shipping, and erection. Wave Tile
panels are installed vertically from the eave to the ridge and from left to right. With the
first panel placed over the inside closure foam. The bottom edge of the panel should
overhang the eave-line by ½ inch. The additional panels overlap by one corrugation as
they progress to the right.

Squareness is essential
The critical point of the panel layout is at the eave line. Always align the panels with the
eaves. It is important that the panels are installed straight along this line, as any deviation
from squareness can lead to problems with the panel installation and the performance of
the roof. When installing the first three panels, use only a few screws to hold them in place.
This allows you to adjust before the panels are fully secured to the deck. To ensure
squareness, checking every third panel during installation is advisable. Once the panels
are aligned properly and the straight line is maintained, you can secure the panels in place.

Care should be taken when handling panels and should be supported or carried on edge to avoid
bowing the panel. Improper handling of the panels during installation may result in small
gaps on the sides near the tile steps. It is recommended that any such gaps be caulked with
an approved silicone-based weather resistant sealant. This will minimize any possibility of
water intrusion at the side-lap.

Product Information & Installation Manual - Page 15 of 32 - ES Wave Tile Roof Panel V1.0
10 WAVE TILE FLASHING DETAILS
This section shows drawings of the most common flashing details. The details presented
may not apply to all conditions or designs. If you have any questions, please contact one
of our representatives.

Flashing Overview:

Product Information & Installation Manual - Page 16 of 32 - ES Wave Tile Roof Panel V1.0
10.1 Eave Drip Detail

Eave Drip Description

The eave drip is installed in a straight line at the eave and should be attached prior to
installation of the roof panels. The minimum overlap of each piece of eave trim must be 4-
inches and installed per local building code.

Product Information & Installation Manual - Page 17 of 32 - ES Wave Tile Roof Panel V1.0
10.2 High Eave Trim Detail

Product Information & Installation Manual - Page 18 of 32 - ES Wave Tile Roof Panel V1.0
10.3 Valley Flashing Detail

Valley Flashing Description


Valley flashing is one of the most critical flashing components of a metal roof system.
It helps divert the water off the roof where two roof planes meet. It is recommended to
install an ice and water shield in the center of the valley to provide a layer of protection
against water infiltration. The valley flashing has an inverted V shape in the middle of
the pan.

The first section of valley flashing is installed at the eave line overhanging 3”-4” inches
and field cut as needed. Each subsequent section of valley flashing must overlap a
minimum of 6 inches, working toward the ridge. A silicone sealant should be applied at
the overlapped area between the valley flashing. Cut the bevel of the underlying valley
flashing to help maintain the valley to be installed straight and level. Secure the valley
flashings with 1 1/2" #10 screws every 1’ to 2’ just inside the valley pan on both sides,
follow your local building code. Install a universal closure foam 2″ wide x 2″ high, 4”-
6” from the valley's centerline. It is recommended to install a bead of silicone sealant
on the top of the universal closure before panel installation. Install the roof panels 3/8”
of an inch overhanging the closure foam. Fasten the roof panels 4” to 6” on center on
the valley. These screws will penetrate the roofing panel, sealant, universal foam, valley
pan, and substrate.

Product Information & Installation Manual - Page 19 of 32 - ES Wave Tile Roof Panel V1.0
10.4 Rake Trim W/ Starter Detail

Rake Trim W/ Starter Description


Installing rake trim and a rake starter on a metal roof creates a finished and professional
look to the roof's edge. Install the rake starter at the roof's edge, ensuring it's flush with the
eave drip. Fasten the rake starter using 1 ½” #10 screws 1’ – 3’ on center. Install the Wave
Tile panel inside the rake starter. Extend the rake trim past the eave line by 2” for the rake
trim to create a return of 90 degrees so the rake trim can be boxed or closed off. Fasten the
rake trim using a 1 ½” #10 screw 1’ - 4’ into the rake starter and fastened to the fascia.
Overlap consecutive trim pieces by 4 inches, minimum up the rake and apply a silicone
sealant at the overlapped area. Use Butyl tape on the bottom edge of the rake trim at the
fascia attachment.

Product Information & Installation Manual - Page 20 of 32 - ES Wave Tile Roof Panel V1.0
10.5 Sidewall Trim Detail

Sidewall Trim Description


Elite Steel Wave tile panels require sidewall trim and starter at all roof-to-wall junctions
where the side of the panel meets a vertical wall. The sidewall starter is installed along the
base of the vertical wall and installed with 1 ½” #10 screw 1’ – 3’ on center, or per local
building codes. Install the Wave Tile panel inside the sidewall starter. Apply flexible
flashing along the edge of the panel, over the sidewall starter, and secure it to the vertical
wall. The sidewall trim is then placed on top of the sidewall starter, the Wave tile panel,
and attached to the vertical wall using standard building practices. Fastening for the
sidewall trim requires using a 1 ½” #10 screw attached to every other high rib, or per local
building code.

Product Information & Installation Manual - Page 21 of 32 - ES Wave Tile Roof Panel V1.0
10.6 Endwall Trim Flashing Detail

Endwall Trim Description


Elite Steel Wave Tile panel requires endwall trim at all roof-to-wall junctions where the
panel meets a vertical wall. Use standard building practices to install the endwall trim
on top of the Wave Tile panel and secure it to the vertical wall. To ensure a water-tight
seal, install our custom outside closure foam strip in-between the endwall trim and roof
panel. Fastening for the endwall trim requires a 1 ½” #10 screw attached to every high
rib, or per local building code. Carefully inspect the endwall trim to ensure it is
securely fastened and there are no gaps or cracks where water could enter.

Product Information & Installation Manual - Page 22 of 32 - ES Wave Tile Roof Panel V1.0
10.7 Endwall Reglet Flashing Detail

10.8 Counter Flashing Detail

Product Information & Installation Manual - Page 23 of 32 - ES Wave Tile Roof Panel V1.0
10.9 Rolled Ridge Cap Detail

Ridge Cap Description


Elite Steel offers three types of ridge caps for Wave Tile panels; step ridge cap, formed
ridge cap, or rolled ridge cap. Step and rolled ridge caps come standard in 10’ lengths and
formed ridge cap comes standard in 9’ 6” lengths. The step ridge cap has a width of 14”.
The rolled ridge cap has a width of 13 ¼”. The formed ridge cap has a width of 15”.

The ridge cap must be centered over the ridge line and aligned with the roof panels. Install
our custom outside closure foam strip in-between the ridge cap and roof panel. Fasten the
ridge cap using 3” #10 screws on both sides. Screws should be fastened minimum at
every other high rib, or per local building code. If the install location is in areas prone to
high wind, fasten the screw through every high rib. Install consecutive ridge caps with a
minimum of 4-inches lap, and apply a silicone sealant at each overlap to ensure a water-
tight seal. If ventilation is needed at the ridge, including the EZ Vent-n-closure
system. See the following detail.

Product Information & Installation Manual - Page 24 of 32 - ES Wave Tile Roof Panel V1.0
10.10 Ridge Ventilation Detail

10.11 Step Ridge Cap Detail

Product Information & Installation Manual - Page 25 of 32 - ES Wave Tile Roof Panel V1.0
10.12 Formed Ridge Cap Detail

Product Information & Installation Manual - Page 26 of 32 - ES Wave Tile Roof Panel V1.0
10.13 Hip-to-Ridge Connection Detail

Hip-to-Ridge Description
The Hip Trim is an important component of the Wave Tile panel installation that helps
prevent water intrusion where the hip and ridge lines intersect. The 4’ hip trim flashing is
installed between the roof panels on the hips of the roof where they meet the ridge. The
Wave Tile panels are cut to match the angle of the hip and installed on the deck.

Product Information & Installation Manual - Page 27 of 32 - ES Wave Tile Roof Panel V1.0
10.14 Hip Cap Detail

Hip Cap Description

Note: The Hip Trim flashings must be installed before the flexible flashing. The flexible
flashing is centered over the hip and installed by pressing and tucking around the hip trim,
down, and onto the panels. Always press the outside edges of the tape to conform to the
roof panel. The flexible flashing is also installed over the panels at hip locations and
conformed to the structure of the Wave tile panel. Use the flexible flashing in all hip
locations.

Before installing the hip cap, first apply butyl tape on the bottom of the hip cap. Extend
the first hip cap 8 inches past the end of the hip. Cut and fold the hip trim to close off the
end or install a custom end cap trim piece. Fasten the hip cap with 3" #10 screws on both
sides at every other high rib, or local building code. Install consecutive hip caps with a
minimum of a 4-inch lap and apply silicone sealant at each overlap to ensure a water-tight
seal.

Product Information & Installation Manual - Page 28 of 32 - ES Wave Tile Roof Panel V1.0
11 PIPE BOOT FITTINGS

Pipe Boot Description


It is important to note that these instructions are general guidelines, and it is always best to
follow the specific instructions and recommendations of the manufacturer of the flashing
boot and roofing material. Install an approved metal roofing pipe boot. This will typically
be made of pliable material, such as rubber or EPDM.
Slide the pipe boot down the pipe until it rests on the roof surface. If necessary, use water
to lubricate the sleeve, making it easier to slide down. Form and bend the base of the
flashing boot to match the contours of the metal roofing panel. It will help ensure a tight
seal around the pipe. Apply Butyl tape between the flashing boot and the metal roofing
panel. Be sure to cover the entire area where the flashing boot meets the panel. Fasten the
flashing boot to the Wave Tile panel using approved fasteners. Place the fasteners 2” to 3”
apart to create a water-tight seal.
Retro flashing boots are designed to provide a water-tight seal around pipe penetrations,
such as electric service poles, where access from the top is not possible or practical. These
boots typically have a split design that allows them to be wrapped around the pipe and
secured with snap rivets and a sealing band. This product is typically available in various
sizes to accommodate different pipe diameters.

Product Information & Installation Manual - Page 29 of 32 - ES Wave Tile Roof Panel V1.0
12 CHIMNEY AND SKYLIGHT FLASHING DETAIL

Chimney and Skylight Flashing Description


Install C-closure trim flashings on the two sides and bottom. Install the Wave Tile panels
inside the C-closure. Apply flexible flashing along the edge of the panel, over the C-
closure, and secure it to the wall of chimney/skylight. The endwall trim is then placed on
the bottom side of the chimney/skylight over the C-closure and Wave Tile panel. Cut and
bend the endwall trim around the sides of the chimney/skylight. Then install the sidewall

Product Information & Installation Manual - Page 30 of 32 - ES Wave Tile Roof Panel V1.0
trim to the sides of the chimney/skylight, so they will overlap the endwall trim. Cut and
fold the ends of the sidewall trim. Apply silicone sealant at all overlaps.

Always use a field fabricated flat sheet on top of chimney/skylights. Make sure you cut
the Wave Tile panel at the top of the chimney/skylight to allow room to install the flat
sheet. The fabricated flat sheet must go underneath the Wave Tile panel. If the
chimney/skylight is wider, a cricket must be installed, and 2 or more field fabricated flat
sheets may be needed. Install closure foam in-between the panel and fabricated flat sheet.
Cut the vertical ends of the flat sheet at an angle and make sure they extend over the high
rib of the Wave Tile panel on both sides of the chimney/skylight. The fabricated flat sheet
goes over the sidewall trim at the corners.

13 HELPFUL HINTS

1. Keep the Wave Tile panels dry and well-ventilated when subjected to wet conditions.
2. Please use caution, Wave Tile panels become extremely slippery when wet.
3. Best practices use a working foam mat during installation.
4. All Wave Tile panels and accessories should be installed in accordance with local
building code. As always, good tradesperson practices should be followed when
installing this product.
5. To prevent possible damage to the panel, you should always walk in the valley of a
panel where a step is located, not the rib and always wear soft-soled shoes.
6. All painted panels and flashings have a factory applied baked-on finish. Handling
and installing panels may result in some small scratches or nicks to the paint finish.
Touch-up paint is available in matching panel colors.
7. Panels should be handled carefully to prevent damage. Never pick up long panels
horizontally at their ends. Always lift panels at the edge when moving. Avoid
dragging panels, it will cause scratching and scouring to the coated surface. Lift
panels at the edge when moving. Depending on the panel size, two or more persons
should handle the panels.
8. Use a tool with a depth-locating nose or adjustable clutch on the screw gun to prevent
over-drilling and striping. All fasteners must be installed straight, not at an angle.
Seating the washer- apply sufficient torque to seat the washer - do not overdrive the
fastener.
9. When cutting or trimming, we recommend using large metal hand shears, power
shears, or nibblers. Never use abrasive metal discs under any circumstances. The heat
caused by this method of cutting can cause the paint and zinc coatings to lose

Product Information & Installation Manual - Page 31 of 32 - ES Wave Tile Roof Panel V1.0
adhesion, and the raw metal shavings will oxidize and rust on the coating causing
permanent damage. This is not covered by the paint warranty.
10. To reduce installation time, pre-drill Wave Tile panels at the required screw
locations on the ground before installing panels on your roof.

Product Information & Installation Manual - Page 32 of 32 - ES Wave Tile Roof Panel V1.0