03 150000 4100001496 SPM Arc DRG 202208 - 02

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

GENERAL KEY PLAN: N

A
N

L
QIB
E
W
S

Legend NOTES:
1. ALL ELEVATIONS (LEVELS) ARE IN METERS.
OFFICE 1
2. ALL DIMENSIONS ARE IN MM AND ANGLES IN DEGREES UNLESS OTHERWISE NOTED.
GF-001
CIRCULATION 3. ONLY WRITTEN DIMENSIONS IN ALL CASES SHALL BE FOLLOWED.
4. ARCHITECTURAL DRAWINGS MUST ALWAYS BE READ IN CONJUNCTION WITH ALL OTHER
RELEVANT SERVICES DRAWINGS AND CONTRACT DOCUMENTS. ANY DISCREPANCY BETWEEN
OFFICE ROOMS THESE DRAWINGS AND DOCUMENTS SHOULD BE REPORTED TO THE ENGINEER FOR
CLARIFICATION AND VERIFICATION.
5. THIS DRAWING READ IN CONJUNCTION WITH THE FOLLOWING DRAWINGS
PROCESS ROOMS "03-150000-4100001496- SPM-STR-DRG-2-00-100"
6. EACH DRAWING HAS TO BE READ IN CONJUNCTIONTYPICAL DETAILS
SHEET REF NO 2-00-306, 2-00-307 & 2-00-308 WHEREVER APPLICABLE
7. THE SITE CONSTRUCTION TEAM SHOULD VERIFY ALL DIMENSIONS AND LEVELS ON SITE
STAFF FACILITIES BEFORE MAKING ANY SHOP DRAWINGS.
8. PLEASE REFER TO SHEET NO: 2-00-300 & 2-00-301& 2-00-309 - SCHEDULE OF OPENINGS FOR
ALL THE OPENING ELEVATIONS AND DETAILS
9. REFER DRAWING NO. 03-150000-4100001496- SPM-ARC-DRG-2-00-400
FOR BUILDING COORDINATES AND COORDINATE SYSTEM.
OFFICE 2 10.DRAWINGS INCORPORATE THE PV SYSTEM VO REQUIREMENTS
COURTYARD (00-4100001496-NEO-LTR-000172).
GF-003
(OPEN TO SKY)

0m 2m 4m 6m 8m 10m
UTILITY
GF-011
VISUAL SCALE 1:100 @ A1

SCADA AND CONTROL ROOM CORRIDOR 1


GF-004 GF-013
W.C 2 RESUBMITTED FOR APPROVAL AEN 19.04.23
GF-013 1 FIRST ISSUE AEN 07.03.23
TOILET (HC) TOILET (F)
GF-010 GF-009 REV DESCRIPTION APP DATE
W.C PURPOSE OF ISSUE:
GF-014
STAGE IFC: FOR CONSTRUCTION
CLIENT: PROJECT MANAGEMENT CONSULTANT:

OFFICE 3
GF-005
TELECOM ROOM TOILET
OFFICE 4 GF-008
GF-013 SERVER ROOM
GF-006
GF-012
DESIGN CONSULTANT NAME & LOGO (s): CONTRACTOR NAME & LOGO (s):
W.C
GF-016
PANTRY
GF-007 W.C P.O BOX. 18271
GF-017 DUBAI, U.A.E
Passion & Solutions
TEL: 04 8865 690
AREA SCHEDULE FAX: 04 8865 691

ROOM
NUMBER NAME NIA IN SQM NIA IN SQFT
DESIGN CONSULTANT / CONTRACTOR: NEOM'S REVIEW:

GROUND FLOOR PLAN GF-001


GF-003
OFFICE 1
OFFICE 2
45.82
45.09
45.82
45.09
DRAWN: VRU 29.08.22
CHECKED: SGS 29.08.22 CHECKED:
GF-004 SCADA AND 45.83 45.83
SCALE 1:100 CONTROL ROOM APPROVED: AEN 29.08.22 APPROVED:
GF-005 OFFICE 3 56.69 56.69
GF-006 OFFICE 4 24.68 24.68
SCALE: 1:100 SHEET SIZE: A1
GF-007 PANTRY 12.69 12.69
GF-008 TOILET 16.63 16.63 DISCIPLINE NAME:
GF-009 TOILET (F) 4.84 4.84 ARCHITECTURAL
GF-010 TOILET (HC) 5.09 5.09
GF-011 UTILITY 46.05 46.05 NER - ADMIN/OFFICE BUILDING
GF-012 SERVER ROOM 8.64 8.64
GF-013 W.C 1.76 1.76
GF-013 TELECOM ROOM 7.43 7.43
AREA CALCULATION
GF-013 CORRIDOR 1 112.75 112.75 PROJECT NAME:
GF-014 W.C 1.73 1.73
GF-015 TOILET 16.54 16.54 NEOM CIRCULAR CITY WATER STORAGE
GF-016
GF-017
W.C
W.C
1.62
1.59
1.62
1.59
RESERVOIRS
455.45 455.45 NEOM INDUSTRIAL CITY
NEOM
TOTAL BUILDING BUILT UP AREA - 575.77SQM (6197.53SQFT)

*NIA = NET INTERNAL AREA


KINGDOM OF SAUDI ARABIA
REGION ASSET CODE CONTRACT CODE

03 150000 4100001496
DRAWING NUMBER STAGE:
IFC
ORIGINATOR DISCIPLINE DOCUMENT TYPE SEQUENTIAL NUMBER REV NO.

SPM ARC DRG 2-02-208 02