0% found this document useful (0 votes)
119 views10 pages

Exocad Instruction Manual Implant Library Editor Overview-En

Uploaded by

labo.bienfait
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
119 views10 pages

Exocad Instruction Manual Implant Library Editor Overview-En

Uploaded by

labo.bienfait
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 10

English

2022-09-19
Instruction Manual
Implant Library Editor – Overview

exocad.com
Instruction Manual by exocad GmbH
© 2022 exocad GmbH
Contact
Rosa-Parks-Str.2
64295 Darmstadt
Germany
phone: +49-6151-629489-0
fax: +49-6151-629489-9
[email protected]
exocad.com

Document version
exocad_IM_Implant Library Editor - Overview, 2022-09-19
Implant Library Editor – Overview

Content
1 Introduction 4

2 Launching the Implant Library Editor 4

3 Actions/Hierarchy Section 4
3.1 New Library . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3.2 Saving/Loading a Library . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.3 Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.4 Submit Library for Validation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3.5 Compare with Other Library . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

4 Information Section 8

5 View Section 8
5.1 Navigation in the View Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
5.2 Show/Hide Objects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5.3 Context Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

6 Support 10
exocad_IM_Implant Library Editor - Overview, 2022-12

© 2022 exocad GmbH | Rosa-Parks-Str.2 | D–64295 Darmstadt page 3/10


Copying, publishing, extracting content or transfer to a third party is prohibited without agreement of exocad GmbH.
Implant Library Editor – Overview

1 Introduction
This document covers the basic features of the Implant Library Editor.
The Implant Library Editor is an editor for exocad’s config.xml library format, with an additional mesh analysis function-
ality. In order to use the Implant Library Editor, you need an exocad dongle which is either activated to work with exocad
DentalCAD Engine Build 4652 or later, or which is activated to work with exoplan.

2 Launching the Implant Library Editor


Step 1: Download the Implant Library Editor from the Documentation&Tools section in the Secure Area of our website
exocad.com/secure-area/documentation-tools.
Step 2: Unpack the Implant Library Editor zip file in a directory of your choice.
Step 3: Run the ExoImplantEditor.exe file.

The now visible Implant Library Editor window is divided into three parts:
1}
mActions/Hierarchy Section: Action icons and library structure

2}
mInformation Section: Section to enter and display information/parameters

3}
mView Section: Display of objects, e.g. geometries

1}
m 2}
m 3}
m
exocad_IM_Implant Library Editor - Overview, 2022-12

3 Actions/Hierarchy Section
3.1 New Library
Depending on which type of new library you want to create, the fol-
lowing steps for a new library vary. For detailed information on
the different settings, see the manuals on creating a library for CAD-
Prosthetic, Implant Planning, Stock-Abutment, Sleeve, Surgical Kit and
Anchor Pin in the Secure Area of our website exocad.com/secure-area/
documentation-tools.

© 2022 exocad GmbH | Rosa-Parks-Str.2 | D–64295 Darmstadt page 4/10


Copying, publishing, extracting content or transfer to a third party is prohibited without agreement of exocad GmbH.
Implant Library Editor – Overview

3.2 Saving/Loading a Library


To save a library, click SAVE LIBRARY in the Action/Hierarchy Section. When
saved, the Implant Library Editor automatically validates the library. If
there are errors, those will be listed in a separate window.
To load a library, click LOAD LIBRARY and select the config.xml file of the
library you want to load. Alternatively, drag and drop the config.xml
file onto the Implant Library Editor window.

3.3 Tools
Click TOOLS in the Actions/Hierarchy Section to access available tools.

Figure 1: Tools

3.3.1 Settings

This tool provides program and view settings.


exocad_IM_Implant Library Editor - Overview, 2022-12

Figure 2: Settings

© 2022 exocad GmbH | Rosa-Parks-Str.2 | D–64295 Darmstadt page 5/10


Copying, publishing, extracting content or transfer to a third party is prohibited without agreement of exocad GmbH.
Implant Library Editor – Overview

INFORMATION

Set the DentalCAD and/or exoplan directory by


clicking the folder symbol and browsing to:

DENTALCAD DIRECTORY: Folder ‘DENTALCADAPP’ of your DentalCAD installation (if available).


EXOPLAN DIRECTORY: Folder ‘IMPLANTPLANNING’ of your exoplan installation (if available).
(Setting both will avoid the information window LIBRARY FOLDER NOT LOADED when starting the
Implant Library Editor.)

3.3.2 Sectional View

This tool provides a sectional view for objects and allows you to define clip planes.

Figure 3: Sectional View

INFORMATION
The clip plane for a sectional view is set from the current orientation of the model in the view
section. In order to get an orthogonal sectional view, orientate the view of your model the
wanted direction by using the arrow buttons in the view section 1} m. Then click the RESET button
2 if a clip plane was set before. The new clip plane can be shifted by dragging the slider 3}
m
} m
exocad_IM_Implant Library Editor - Overview, 2022-12

1}
m

3}
m
2}
m

© 2022 exocad GmbH | Rosa-Parks-Str.2 | D–64295 Darmstadt page 6/10


Copying, publishing, extracting content or transfer to a third party is prohibited without agreement of exocad GmbH.
Implant Library Editor – Overview

3.3.3 Open library folder

Opens the folder in which the config.xml file and all other files related to this library are stored.

3.4 Submit Library for Validation


Clicking SUBMIT LIBRARY FOR VALIDATION in the Actions/Hierarchy section initiates a priliminary check of the library data.
If the Implant Library Editor detects errors, these will be listed in a separate window. Only error-free libraries can be sent
to exocad for signing. If no errors were detected clicking SUBMIT LIBRARY FOR VALIDATION opens the website exocad.com/
implantdata, which contains information and policies for submitting a library to exocad. Additionally, a folder with the library
data is automatically created and stored on your desktop.
Note: The storage directory for the library data can be changed by editing the SUBMIT LIBRARY STORAGE DIRECTORY in the
settings menu (Figure 2).

3.5 Compare with Other Library


Using the COMPARE WITH OTHER LIBRARY function, you can compare a library with other libraries, e.g. implant libraries with
stock abutment libraries, to determine if a connection part fits an implant properly.

Step 1: Select an entry in the lowest level of your library and expand COMPARE WITH OTHER LIBRARY at the bottom of the
Action/Hierarchy Section.

Step 2: Click SELECT IMPLANT ENTRY and select a library from the dropdown list. The list shows available libraries within
your exocad installation.
Note: In order for these libraries to be available in the list, the directory of your DentalCAD and/or exoplan
installation must be selected in the SETTINGS (Chapter 3.3.1). If you want to compare to a library that is not stored
within your DentalCAD or exoplan directory, click the folder icon and select the config.xml file of the library.
Step 3: Click SELECT TYPE and, successively, SELECT SUBTYPE to select the library type and subtype relevant for your
comparison. You can also select to LOAD ALL SUB ENTRIES, which will load all types and subtypes of the selected
library.
exocad_IM_Implant Library Editor - Overview, 2022-12

Activate SHOW ONLY COMPATIBLE to show only compatible libraries. To view only specific library types, check the
corresponding checkboxes in the VIEW ONLY THESE CONFIG TYPES section.

Once you have specified the items for your comparison, the selected geometries are displayed together in the View Section.
If both libraries are correctly set up, they are displayed in correct reference to each other. The COMPARE WITH OTHER LIBRARY
section is extended.

© 2022 exocad GmbH | Rosa-Parks-Str.2 | D–64295 Darmstadt page 7/10


Copying, publishing, extracting content or transfer to a third party is prohibited without agreement of exocad GmbH.
Implant Library Editor – Overview

Figure 4: Extended COMPARE WITH OTHER LIBRARY section


Compatible and incompatible libraries are displayed as two separate lists. The compatibility refers to the currently
selected entry in the Hierarchy section and updates automatically when selecting another entry. You can select further
libraries to be added and can switch from one library to the other in the list. Remove libraries from the list using the x
symbol.
By default, EXPLODE is active and the library geometries are displayed side-by-side in the View Section. If you uncheck,
they are displayed at the same location.
Use the eye symbols to show/hide the library geometries in the View Section.
Click CLEAR to clear libraries from the list. Clicking INCOMPATIBLE removes incompatibale libraries (libraries not match-
ing the parameters defined in the library compatibility settings). Clicking ALL removes all libraries.

4 Information Section
The necessary information and data is queried and displayed here, depending on the type of library (see Chapter 3.1).

5 View Section
5.1 Navigation in the View Section

Function Description

Scroll mouse wheel Zoom in/out (zoom center = mouse position).


exocad_IM_Implant Library Editor - Overview, 2022-12

Hold right mouse button and drag Rotate the view around the rotation center (object center by default).

Right-click outer frame and drag Rotate the view using the view axis around the rotation center (object
center by default).

Click middle mouse button / mouse wheel Center the view and set a new rotation center.

Hold both mouse buttons and drag Move the view freely.

Num1,2,3,4,6,8 (Numpad activated) or Set view to top, frontal, etc.


arrow buttons in the View Section:

© 2022 exocad GmbH | Rosa-Parks-Str.2 | D–64295 Darmstadt page 8/10


Copying, publishing, extracting content or transfer to a third party is prohibited without agreement of exocad GmbH.
Implant Library Editor – Overview

5.2 Show/Hide Objects


In the upper left corner of the View Section, avail-
able objects for display are listed, each with an eye
symbol (see Figure 5). Show/hide objects by clicking
the eye symbols. You can change the transparency
of an object by using the corresponding line in the
list as a slider.

Figure 5: Object list in View Section

5.3 Context Menu


Access the context menu by right-clicking an object.

Figure 6: Context menu

Function Description

ZOOM TO OBJECT Zoom to the selected object.

VISUAL PROPERTIES Set visual properties for the object:

HIDE THIS OBJECT: Hides the object.

WIREFRAME: Shows the triangle grid of the object.

POINT CLOUD: Shows the object as point cloud.

FLAT SHADING ONLY: Activated by default to visualize the flat areas of a geometry.
Deactivation changes the illumination angle, allowing a more realistic visualization of
exocad_IM_Implant Library Editor - Overview, 2022-12

round objects.

OPAQUE VALUES: Transparency settings.

LINE THICKNESS: Only available if WIREFRAME and/or OUTLINE is activated. Allows you to
define the thickness of lines.

ABOUT... Displays software information (version, engine build, copyright information). You can also
access this information by right-clicking the background.

© 2022 exocad GmbH | Rosa-Parks-Str.2 | D–64295 Darmstadt page 9/10


Copying, publishing, extracting content or transfer to a third party is prohibited without agreement of exocad GmbH.
Implant Library Editor – Overview

6 Support
We provide third-level support to our partners in case of technical questions/issues related to our products, usage of the
software, exoportal, etc. You can contact our support team to request quick online demonstrations of new features demon-
strated by application specialists.
As a certified company (ISO 13485), we document support issues and the given solutions or results. To contact our support
team, please send a request to your region’s respective email address. Your email will automatically create a ticket in our
support system. You will receive a ticket number along with the automatic response email. Our support team will contact
you by email or by phone.
To follow up, please keep your ticket number ready. A convenient way to follow up is to reply to our ticket response email.
Without a ticket number, we cannot handle your request (especially when making contact via Skype). Thank you for your
understanding.

IMPORTANT
To resolve your issue quickly and smoothly:
Send a separate email for each issue. Please do not introduce new topics to an existing email
conversation!
Do not modify the subject line of the support reply email!
Provide all necessary data (library, project file, scan data, construction files) and additional
information (software build number, OS, etc). Without this data, we cannot reproduce a
problem (technical or usage) and therefore, we cannot handle it!

To view the support contact details of your support region, visit exocad.com/secure-area/technical-and-software-support.
exocad_IM_Implant Library Editor - Overview, 2022-12

© 2022 exocad GmbH | Rosa-Parks-Str.2 | D–64295 Darmstadt page 10/10


Copying, publishing, extracting content or transfer to a third party is prohibited without agreement of exocad GmbH.