Exocad Instruction Manual Implant Library Editor Overview-En
Exocad Instruction Manual Implant Library Editor Overview-En
2022-09-19
Instruction Manual
Implant Library Editor – Overview
exocad.com
Instruction Manual by exocad GmbH
© 2022 exocad GmbH
Contact
Rosa-Parks-Str.2
64295 Darmstadt
Germany
phone: +49-6151-629489-0
fax: +49-6151-629489-9
[email protected]
exocad.com
Document version
exocad_IM_Implant Library Editor - Overview, 2022-09-19
Implant Library Editor – Overview
Content
1 Introduction 4
3 Actions/Hierarchy Section 4
3.1 New Library . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3.2 Saving/Loading a Library . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.3 Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.4 Submit Library for Validation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3.5 Compare with Other Library . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
4 Information Section 8
5 View Section 8
5.1 Navigation in the View Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
5.2 Show/Hide Objects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5.3 Context Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
6 Support 10
exocad_IM_Implant Library Editor - Overview, 2022-12
1 Introduction
This document covers the basic features of the Implant Library Editor.
The Implant Library Editor is an editor for exocad’s config.xml library format, with an additional mesh analysis function-
ality. In order to use the Implant Library Editor, you need an exocad dongle which is either activated to work with exocad
DentalCAD Engine Build 4652 or later, or which is activated to work with exoplan.
The now visible Implant Library Editor window is divided into three parts:
1}
mActions/Hierarchy Section: Action icons and library structure
2}
mInformation Section: Section to enter and display information/parameters
3}
mView Section: Display of objects, e.g. geometries
1}
m 2}
m 3}
m
exocad_IM_Implant Library Editor - Overview, 2022-12
3 Actions/Hierarchy Section
3.1 New Library
Depending on which type of new library you want to create, the fol-
lowing steps for a new library vary. For detailed information on
the different settings, see the manuals on creating a library for CAD-
Prosthetic, Implant Planning, Stock-Abutment, Sleeve, Surgical Kit and
Anchor Pin in the Secure Area of our website exocad.com/secure-area/
documentation-tools.
3.3 Tools
Click TOOLS in the Actions/Hierarchy Section to access available tools.
Figure 1: Tools
3.3.1 Settings
Figure 2: Settings
INFORMATION
This tool provides a sectional view for objects and allows you to define clip planes.
INFORMATION
The clip plane for a sectional view is set from the current orientation of the model in the view
section. In order to get an orthogonal sectional view, orientate the view of your model the
wanted direction by using the arrow buttons in the view section 1} m. Then click the RESET button
2 if a clip plane was set before. The new clip plane can be shifted by dragging the slider 3}
m
} m
exocad_IM_Implant Library Editor - Overview, 2022-12
1}
m
3}
m
2}
m
Opens the folder in which the config.xml file and all other files related to this library are stored.
Step 1: Select an entry in the lowest level of your library and expand COMPARE WITH OTHER LIBRARY at the bottom of the
Action/Hierarchy Section.
Step 2: Click SELECT IMPLANT ENTRY and select a library from the dropdown list. The list shows available libraries within
your exocad installation.
Note: In order for these libraries to be available in the list, the directory of your DentalCAD and/or exoplan
installation must be selected in the SETTINGS (Chapter 3.3.1). If you want to compare to a library that is not stored
within your DentalCAD or exoplan directory, click the folder icon and select the config.xml file of the library.
Step 3: Click SELECT TYPE and, successively, SELECT SUBTYPE to select the library type and subtype relevant for your
comparison. You can also select to LOAD ALL SUB ENTRIES, which will load all types and subtypes of the selected
library.
exocad_IM_Implant Library Editor - Overview, 2022-12
Activate SHOW ONLY COMPATIBLE to show only compatible libraries. To view only specific library types, check the
corresponding checkboxes in the VIEW ONLY THESE CONFIG TYPES section.
Once you have specified the items for your comparison, the selected geometries are displayed together in the View Section.
If both libraries are correctly set up, they are displayed in correct reference to each other. The COMPARE WITH OTHER LIBRARY
section is extended.
4 Information Section
The necessary information and data is queried and displayed here, depending on the type of library (see Chapter 3.1).
5 View Section
5.1 Navigation in the View Section
Function Description
Hold right mouse button and drag Rotate the view around the rotation center (object center by default).
Right-click outer frame and drag Rotate the view using the view axis around the rotation center (object
center by default).
Click middle mouse button / mouse wheel Center the view and set a new rotation center.
Hold both mouse buttons and drag Move the view freely.
Function Description
FLAT SHADING ONLY: Activated by default to visualize the flat areas of a geometry.
Deactivation changes the illumination angle, allowing a more realistic visualization of
exocad_IM_Implant Library Editor - Overview, 2022-12
round objects.
LINE THICKNESS: Only available if WIREFRAME and/or OUTLINE is activated. Allows you to
define the thickness of lines.
ABOUT... Displays software information (version, engine build, copyright information). You can also
access this information by right-clicking the background.
6 Support
We provide third-level support to our partners in case of technical questions/issues related to our products, usage of the
software, exoportal, etc. You can contact our support team to request quick online demonstrations of new features demon-
strated by application specialists.
As a certified company (ISO 13485), we document support issues and the given solutions or results. To contact our support
team, please send a request to your region’s respective email address. Your email will automatically create a ticket in our
support system. You will receive a ticket number along with the automatic response email. Our support team will contact
you by email or by phone.
To follow up, please keep your ticket number ready. A convenient way to follow up is to reply to our ticket response email.
Without a ticket number, we cannot handle your request (especially when making contact via Skype). Thank you for your
understanding.
IMPORTANT
To resolve your issue quickly and smoothly:
Send a separate email for each issue. Please do not introduce new topics to an existing email
conversation!
Do not modify the subject line of the support reply email!
Provide all necessary data (library, project file, scan data, construction files) and additional
information (software build number, OS, etc). Without this data, we cannot reproduce a
problem (technical or usage) and therefore, we cannot handle it!
To view the support contact details of your support region, visit exocad.com/secure-area/technical-and-software-support.
exocad_IM_Implant Library Editor - Overview, 2022-12