2d Angular Sensor CT310-Murata
2d Angular Sensor CT310-Murata
CT310
XtremeSense™ 2D TMR Angular Sensor
Features Product Description
• Angular Error less than 0.25° (After Compensation) The CT310 is a 2D angular sensor in a dual full-bridge
Over Full Temperature Range configuration from Crocus Technology developed on its
• Dual Full-Bridge Resistor Network patented XtremeSense™ 2D TMR technology. The
• Operating Magnetic Field: 25 mT to 90 mT operating magnetic field for this 2D sensor is 25 mT to 90
• Differential Outputs for SIN and COS Axes mT and has an angular error less than 0.25° after
• Supply Voltage: 1.0 V to 5.5 V compensation over the full operating temperature range. It
• Package Options: has differential outputs for both sine (SIN) and cosine
o 8-lead TSSOP (COS) axes and operates with a supply voltage range from
o 8-lead DFN, 2.00 × 2.00 × 0.45 mm 1.0 V to 5.5 V.
Ordering Information
Operating Angular Packing
Part Number Output Type Package
Temperature Range Error (1) Method
CT310LS-IT8-M -40°C to +85°C 8-lead TSSOP
0.25° Differential Tape & Reel
CT310LS-HT8-M -40°C to +125°C 6.40 x 3.05 x 1.10 mm
CT310LS-ID8-M -40°C to +85°C 8-lead DFN
0.25° Differential Tape & Reel
CT310LS-HD8-M -40°C to +125°C 2.00 x 2.00 x 0.45 mm
(1) After Compensation
Block Diagram
VCOS VSIN
6 2
R R R R
COSP 5 3 SINP
COSN 7 1 SINN
R R R R
8 4
GND GND
SIN Axis
1 SIN Axis 8
2 7
COS Axis
3 6
4 5
Figure 2. CT310 Axes of Sensitivity for TSSOP-8 Figure 3. CT310 Axes of Sensitivity for DFN-8
Pin Configurations
1 8
2 7
3 6
4 5
8 7 6 5 5 6 7 8
1 2 3 4 4 3 2 1
Pin Definitions
TSSOP-8 DFN-8
Pin Name Pin Description
Pin # Pin #
1 1 SINN Differential negative output for sine.
2 2 VSIN Supply voltage for sine
3 3 SINP Differential positive output for sine.
4 4 GND Ground for sine.
5 5 COSP Differential positive output for cosine.
6 6 VCOS Supply voltage for cosine
7 7 COSN Differential negative output for cosine.
8 8 GND Ground for cosine.
Pad Configuration
SINN GND
VSIN COSN
TMR Sensor
SINP VCOS
GND COSP
Pad Definitions
Pad # Pad Name Pad Description
1 SINN Differential negative output for sine.
2 VSIN Supply voltage for sine
3 SINP Differential positive output for sine.
4 GND Ground for sine.
5 COSP Differential positive output for cosine.
6 VCOS Supply voltage for cosine
7 COSN Differential negative output for cosine.
8 GND Ground for cosine.
Stresses exceeding the absolute maximum ratings may damage the CT310 and may not function or be operable above the
recommended operating conditions and stressing the parts to these levels is not recommended. In addition, extended exposure
to stresses above the recommended operating conditions may affect device reliability. The absolute maximum ratings are
stress ratings only.
Unless otherwise specified: VDD = 1.0 V to 5.5 V, CBYP = 0.1 µF, BOPERATING = 25 mT to 90 mT and TA = -40°C to +150°C.
Typical values are VDD = 3.0 V and TA = +25°C.
Electrical Characteristics
Figure 6. Output Voltage vs. Angle at BOP = 25 mT Figure 7. Output Voltage vs. Angle at BOP = 90 mT
1.0 V to 5.5 V
VCOS VSIN
6 2 0.1 µF
R R R R
COSP 5 3 SINP
COSN 7 1 SINN
R R R R
8 4
GND
Component Description Vendor & Part Number Parameter Min. Typ. Max. Unit
Murata
CBYP 0.1 µF, X7R GRM033Z71A104KE14 C 0.1 µF
Others
Applications Information
The MLU sensor location for the CT310 for the x, y dimensions are shown in Figure 9 and Figure 10 for the TSSOP-8 and
DFN-8 packages respectively. Figure 11 and Figure 12 illustrates the location of the CT310’s MLU sensor from the z
dimension. All dimensions in the figures below are nominal.
1.00 mm
3.200 mm
1.00 mm
1 8
1.525 mm
2 7
3.050 mm
2.00 mm
3 6
4 5
6.400 mm
2.00 mm
Figure 9. MLU Sensor Location in x-y Plane for CT310 Figure 10. MLU Sensor Location in x-y Plane for
in TSSOP-8 Package CT310 in DFN-8 Package
0.175 mm
1.000 mm 0.450 mm
Figure 11. MLU Sensor Location in z Dimension for Figure 12. MLU Sensor Location in z Dimension for
CT310 in TSSOP-8 Package CT310 in DFN-8 Package
NOTE:
1. The terminal #1 identifier is a laser marked feature.
Figure 15. DFN-8 Package Drawing
Package Information
Table 4. CT310 Package Information
MSL Device
Package # of Package Lead Operating
Part Number Eco Plan (1) Rating
Type Leads Quantity Finish (2) Temperature (3) Marking
CT310LS-IT8
CT310LS-IT8-M TSSOP 8 3,000 Sn Green & RoHS 1 -40°C to +85°C
YYWWSS
CT310LS-HT8
CT310LS-HT8-M TSSOP 8 3,000 Sn Green & RoHS 1 -40°C to +125°C
YYWWSS
310I
CT310LS-ID8-M DFN 8 3,000 Sn Green & RoHS 1 -40°C to +85°C
YWWS
310H
CT310LS-HD8-M DFN 8 3,000 Sn Green & RoHS 1 -40°C to +125°C
YWWS
(1) RoHS is defined as semiconductor products that are compliant to the current EU RoHS requirements. It also will meet the
requirement that RoHS substances do not exceed 0.1% by weight in homogeneous materials. Green is defined as the content
of Chlorine (Cl), Bromine (Br) and Antimony Trioxide based flame retardants satisfy JS709B low halogen requirements of ≤ 1,000
ppm.
(2) MSL Rating = Moisture Sensitivity Level Rating as defined by JEDEC standard classifications.
(3) Package will withstand ambient temperature range of -40°C to +150°C and storage temperature range of -65°C to +165°C.
(4) Device Marking for TSSOP is defined as CT310LS-XT8 YYWWSS where CT310LS = base part number, X = temperature code,
T8 = TSSOP-8 package, YY = year, WW = work week and SS = sequential number. DFN is defined as 300X where X =
temperature code and Y = year, WW = work week and S = sequential number.
Disclaimer: The contents of this document are provided for informational purposes only. CROCUS TECHNOLOGY, INC.
AND CROCUS TECHNOLOGY SA (COLLECTIVELY “CROCUS”) MAKE NO REPRESENTATIONS OR WARRANTY OF
ANY KIND, EXPRESS OR IMPLIED, WITH RESPECT TO THE ACCURACY OR COMPLETENESS OF THE CONTENTS
HEREIN, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS
FOR A PARTICULAR PURPOSE. Crocus reserves the right to make changes to the specifications and product descriptions,
and/or to discontinue or make changes to its products at any time without notice. Crocus’s products have not been designed,
tested, or manufactured for use and should not be used in applications where the failure, malfunction or inaccuracy of the
Products carries a risk of death or serious bodily injury or damage to tangible property, including, but not limited to, life
support systems, nuclear facilities, military, aircraft navigation or communication, emergency systems, harsh environments,
or other applications with a similar degree of potential hazard.