Shenzhen Zhongjian Nanfang Testing Co., Ltd.

Report No: CCISE170603406

1 Cover Page
SPECTRUM REPORT
(GPS)

Applicant: Shanghai Sunmi Technology Co.,Ltd.


Room 505, KIC Plaza, No.388 Song Hu Road, Yang Pu District,
Address of Applicant:
Shanghai, China
Equipment Under Test (EUT)

Product Name: Wireless data POS System

Model No.: W5920

Trade mark: SUNMI

Applicablestandards: ETSI EN 303 413 V1.1.1 (2017-06)

Date of sample receipt: 06 Jun., 2017

Date of Test: 06 Jun., to 14 Jul., 2017

Date of report issued: 17 Jul., 2017

Test Result: PASS*


*In the configuration tested, the EUT complied with the standards specified above.

The CE mark as shown below can be used, under the responsibility of the manufacturer, after completion of an EC Declaration of
Conformity and compliance with all relevant EC Directives. The protection requirements with respect to electromagnetic compatibility
contained in Directive 2014/53/EU are considered.

Bruce Zhang
Laboratory Manager
This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other
samples of the same product and does not permit the use of theCCISproduct certification mark. The manufacturer should ensure that all
products in series production are in conformity with the product sample detailed in this report.

This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than that detailed in
the report, the manufacturer must ensure the new system complies with all relevant standards.

This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery
orfalsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days
only.
Report No: CCISE170603406

2 Version

Version No. Date Description


00 17 Jul., 2017 Original
01 09 Aug., 2017 Updated Product Name on P.1/P.5

Tested by: Date: 17 Jul., 2017

Test Engineer

Reviewed by: Date: 17 Jul., 2017

Project Engineer

Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1706034


No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 2 of 15
Report No: CCISE170603406

3 Contents
Page
1 COVER PAGE ....................................................................................................................................................... 1
2 VERSION ............................................................................................................................................................... 2
3 CONTENTS ........................................................................................................................................................... 3
4 TEST SUMMARY .................................................................................................................................................. 4
5 GENERAL INFORMATION .................................................................................................................................. 5
5.1 CLIENT INFORMATION ........................................................................................................................................... 5
5.2 GENERAL DESCRIPTION OF E.U.T. ...................................................................................................................... 5
5.3 TEST MODE ............................................................................................................................................................ 5
5.4 DESCRIPTION OF SUPPORT UNITS ........................................................................................................................ 5
5.5 LABORATORY FACILITY ........................................................................................................................................ 6
5.6 LABORATORY LOCATION ...................................................................................................................................... 6
5.7 TEST INSTRUMENTS LIST....................................................................................................................................... 7
6 RADIO TECHNICAL REQUIREMENTS SPECIFICATION IN ETSI EN 301 413............................................ 8
6.1 TEST ENVIRONMENT .............................................................................................................................................. 8
6.1.1 GUE adjacent frequency band selectivity performance ........................................................................... 9
6.1.2 Receiver spurious emissions ...................................................................................................................... 11
7 TEST SETUP PHOTO ........................................................................................................................................ 14
8 EUT CONSTRUCTIONAL DETAILS ................................................................................................................ 15

Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1706034


No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 3 of 15
Report No: CCISE170603406

4 Test Summary
Radio Spectrum Matter (RSM) Part ofTransmitter

Test Items Test Requirement Test method Limit/Severity Uncertainty Result


GUE adjacent
frequency band EN 303 413 EN 303 413
Δ C/N0 ≤ 1 dB  0.1dB PASS
selectivity section 4.2.1 section 5.4.3
performance
Receiver spurious EN 303 413 EN 303 413
Table 4-5  4.88dB PASS
emissions section 4.2.2 section 5.5.2
Remark:
1>. Pass: The EUT complies with the essential requirements in the standard.
2>. Temperature (Uncertainty): ±1℃ Humidity(Uncertainty): ±5%

Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1706034


No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 4 of 15
Report No: CCISE170603406

5 General Information
5.1 Client Information
Applicant: Shanghai Sunmi Technology Co.,Ltd.
Room 505, KIC Plaza, No.388 Song Hu Road, Yang Pu District,
Address of Applicant: Shanghai, China
Manufacturer: Shanghai Sunmi Technology Co.,Ltd.
Address of Manufacturer: Room 505, KIC Plaza, No.388 Song Hu Road, Yang Pu District,
Shanghai, China
Factory: Shenzhen Starworks Technology Co.,LTD.
Address of Factory: Basicom lndustry Park, Baolong Avenue 3rd Road, Longgang District,
Shenzhen City, Guangdong Province, P.R.China

5.2 General Description of E.U.T.


Product Name: Wireless data POS System
Model No.: W5920
Operation Frequency: 1.57542GHz
Hardware version: 2.0
Software version: 1.1.0
Antenna Type: Internal Antenna
AC Adapter: Adapter(1)
European specifications:
Model: TPA-46050200VU
Input: AC100-240V 50/60Hz 0.3 A
Output: DC 5.0V, 2000 mA
Adapter(2)
British specifications:
Model: TPA-59050200BU
Input: AC100-240V 50/60Hz 0.3 A
Output: DC 5.0V, 2000 mA
Power supply: Rechargeable Li-ion Battery DC3.6V/5200mAh

5.3 Test mode


Receiving mode: Keep the EUT in receive mode by GPS.

5.4 Description of Support Units


The EUT was test as an independent unit

Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1706034


No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 5 of 15
Report No: CCISE170603406

5.5 Laboratory Facility


The test facility is recognized, certified, or accredited by the following organizations:
● FCC - Registration No.: 817957
Shenzhen Zhongjian Nanfang Testing Co., Ltd. EMC Laboratory has been registered andfully
describedin a report filed with the (FCC) Federal Communications Commission. The acceptance
letter from the FCC is maintained in out files. Registration 817957, February 27, 2012.
● IC - Registration No.: 10106A-1
The 3m Semi-anechoic chamber of Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been
Registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing
with Registration No.: 10106A-1.
● CNAS - Registration No.: CNAS L6048
Shenzhen Zhongjian Nanfang Testing Co., Ltd. is accredited to ISO/IEC 17025:2005 General
Requirements for the Competence of Testing and Calibration laboratories for the competence of
testing. The Registration No. is CNAS L6048.

5.6 Laboratory Location


Shenzhen Zhongjian Nanfang Testing Co., Ltd.
Address: No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Website: http://www.ccis-cb.com
Tel: +86-755-23118282
Fax:+86-755-23116366
Email: [email protected]

Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1706034


No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 6 of 15
Report No: CCISE170603406

5.7 Test Instruments list


Radiated Emission:
Cal. Date Cal. Due date
Item Test Equipment Manufacturer Model No. Inventory No.
(mm-dd-yy) (mm-dd-yy)
1 3m SAC SAEMC 9(L)*6(W)* 6(H) CCIS0001 08-23-2014 08-22-2017
2 BiConiLog Antenna SCHWARZBECK VULB9163 CCIS0005 02-25-2017 02-24-2018
3 Horn Antenna SCHWARZBECK BBHA9120D CCIS0006 02-25-2017 02-24-2018
Pre-amplifier
4 HP 8447D CCIS0003 02-25-2017 02-24-2018
(10kHz-1.3GHz)
Pre-amplifier Compliance Direction
5 PAP-1G18 CCIS0011 02-25-2017 02-24-2018
(1GHz-18GHz) Systems Inc.
Pre-amplifier AFS33-18002
6 Rohde & Schwarz GTS218 02-25-2017 02-24-2018
(18-26GHz) 650-30-8P-44
7 Horn Antenna ETS-LINDGREN 3160 GTS217 02-25-2017 02-24-2018
Spectrum analyzer
8 Rohde & Schwarz FSP30 CCIS0023 02-25-2017 02-24-2018
9k-30GHz
9 EMI Test Receiver Rohde & Schwarz ESRP7 CCIS0167 02-25-2017 02-24-2018
10 Loop antenna SCHNARZBECK FMZB1519 CCIS0188 02-25-2017 02-24-2018
11 EMI Test Software AUDIX E3 N/A N/A N/A
Vector Signal
12 Agilent N5182A EMC0702 02-25-2017 02-24-2018
Generator
Vector Signal
13 R&S SMBV100A EMC0703 02-25-2017 02-24-2018
Generator

Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1706034


No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 7 of 15
Report No: CCISE170603406

6 Radio Technical Requirements Specification in ETSI EN 301 413


6.1 Test environment
Voltage
Test Relative Lead-acid
Temperature Other power
Humidity AC mains battery on
Condition sources
vehicles
1,1 times the
Normal +15°C to +35°C 20% to 75% nominal nominal
nominal voltage
-20°C to +55°C
▼0,85 times
(General use)
(Leclanché or lithium)
-10°C to +55°C ▼0,9 times ▼0,9 times
Extreme 20% to 75% 0,9 times (mercury
(Portable use) ▲1,1 times ▲1,3 times or nickel-cadmium)
5°C to +35°C ▲1,15 times
(Indoor use)

Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1706034


No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 8 of 15
Report No: CCISE170603406

6.1.1 GUE adjacent frequency band selectivity performance


Test Requirement: EN 303 413 clause 4.2.1
Test Method: EN 303 413 clause 5.4.3
Limit: The C/N0 metric reported by the GUE for all GNSS and GNSS signals
given in table 4-1 and supported by the GUE shall not degrade by more
than the value given in equation 4-1 when an adjacent frequency signal is
applied. The adjacent frequency signal is defined in table 4-4, with the
frequencies and power levels defined in table 4-2 and/or in table 4-3
depending on the RNSS bands supported by the GUE.
Equation 4-1: Maximum degradation in C/N0

Test Frequency range: 1 559 MHz to 1 610 MHz


Test setup:

Test procedure: 1. Configure the GNSS signal generator to simulate those GNSS and
GNSS signals from table 4-1 declared as supported by the GUE, with
power levels and other details as specified in clause B.2.
2. With the adjacent frequency signal switched off, the EUT shall be
given sufficient time to acquire all simulated satellites from the
declared GNSS system(s).
3. Record the baseline C/N0 value(s) reported by the EUT. Sufficient
filtering shall be used to obtain a stable value. C/N0 may be averaged
across all the satellites in view for each GNSS constellation.
However, C/N0 shall not be averaged across satellite signals in
different GNSS constellations. For a multi-GNSS EUT, there shall be
a separate C/N0 value recorded for each GNSS constellation and
each GNSS signal supported.
4. The adjacent frequency signal generator shall be configured to
generate the signal defined in table 4-4, at the first test point centre
frequency and signal power level as specified in table 4-2.
5. The adjacent frequency signal shall be switched on, and the EUT's
C/N0 value(s) recorded as in step 3) to measure the degradation with
respect to the baseline value(s) recorded in step 3).
6. 6) Test point Pass/Fail Criteria: If the C/N0 degradation from step 5)
does not exceed the value in equation 4-1, then this test point is set
to "pass". If the C/N0 degradation exceeds the value in equation 4-1,
then this test point is set to "fail." For a multi-GNSS and multi-signal
EUT, there shall be a separate pass/fail determination for each
Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1706034
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 9 of 15
Report No: CCISE170603406

GNSS and for each GNSS signal supported. If the C/N0 degradation
exceeds the value in equation 4-1 for any supported GNSS or
supported GNSS signal, then this test point is set to "fail".
7. 7) Step 1) through step 6) shall be repeated for all test point centre
frequencies (and associated signal power level) specified in table 4-2.
Test Instruments: See the section 5.7
Test mode: Kept Rx in receive mode.

Measurement Data:
Test point Adjacent GPS Measured C/N0 (dB)
Frequency band centre frequency
(MHz) frequency signal power No interfering With interfering Decrease Δ C/N0
(MHz) level (dBm) signal signal of C/N0 ≤1
1 518 to 1 525 1524 -65 48.82 48.93 0.11 Pass
1 525 to 1 549 1548 -95 49.06 49.59 0.53 Pass
1 549 to 1 559 1554 -105 49.33 49.81 0.48 Pass
1 559 to 1 610 GUE RNSS band under test
1 610 to 1 626 1615 -105 48.28 48.89 0.61 Pass
1 626 to 1 640 1627 -85 49.05 49.72 0.67 Pass

Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1706034


No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 10 of 15
Report No: CCISE170603406

6.1.2 Receiver spurious emissions


Test Requirement: EN 303 413 clause 4.2.2
Test Method: EN 303 413 clause 5.5.2
Frequency<1000MHz; RBW=100KHz, VBW=300KHz, Detector= peak
Receiver setup:
Frequency>=1000MHz; RBW=1MHz, VBW=3MHz, Detector=peak.
Limit: Frequency Limit
30MHz to 1000 MHz -57dBm
Above 1GHz -47dBm
Test Frequency range: 30MHz to 8.3GHz
Test setup: Below 1GHz

Above 1GHz

Test procedure: Substitution method was performed to determine the actual ERP
emission levels of the EUT.
The following test procedure as below:

Below 1GHz test procedure:


1. On the test site as test setup graph above, the EUT shall be placed at
the 1.5msupport on the turntable and in the position closest to normal
use as declared by the provider.
2. The test antenna shall be oriented initially for vertical polarization and
shall be chosen to correspond to the frequency of the transmitter.
The output of the test antenna shall be connected to the measuring
receiver.
3. The transmitter shall be switched on, if possible, without modulation
and the measuring receiver shall be tuned to the frequency of the
transmitter under test.
4. The test antenna shall be raised and lowered from 1m to 4muntil a
maximum signal level is detected by the measuring receiver. Then
Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1706034
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 11 of 15
Report No: CCISE170603406

the turntable should be rotated through 360°in the horizontal plane,


until the maximum signal level is detected by the measuring receiver.
5. Repeat step 4 for test frequency with the test antenna polarized
horizontally.
6. Remove the transmitter and replace it with a substitution antenna (the
antenna should be half-wavelength for each frequency involved). The
center of the substitution antenna should be approximately at the
same location as the center of the transmitter. At the lower
frequencies, where the substitution antenna is very long, this will be
impossible to achieve when the antenna is polarized vertically. In
such case the lower end of the antenna should be 0.3 m above the
ground.
7. Feed the substitution antenna at the transmitter end with a signal
genera to connected to the antenna by means of a non-radiating
cable. With the antennas at both ends vertically polarized, and with
the signal generator tuned to a particular test frequency, raise and
lower the test antenna to obtain a maximum reading at the spectrum
analyzer. Adjust the level of the signal generator output until the
previously recorded maximum reading for this set of conditions is
obtained. This should be done carefully repeating the adjustment of
the test antenna and generator output.
8. Repeat step 7 with both antennas horizontally polarized for each test
frequency.
9. Calculate power in dBm into a reference ideal half-wave dipole
antenna by reducing the readings obtained in steps 7 and 8 by the
power loss in the cable between the generator and the antenna, and
further corrected for the gain of the substitution antenna used relative
to an ideal half-wave dipole antenna by the following formula:
ERP(dBm) = Pg(dBm) – cable loss (dB) + antenna gain (dBd)
Where: Pg is the generator output power into the substitution
antenna.

Above 1GHz test procedure:


Different between above is the test site, change from Semi- Anechoic
Chamber to fully Anechoic Chamber, and the test antenna do not
need to raise from 1 to 4m, just test in 1.5m height.
Test Instruments: See the section 5.7
Test mode: Kept Rx in receive mode.
Measurement Record: Uncertainty: 4.88dB

Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1706034


No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 12 of 15
Report No: CCISE170603406

Measurement Data:
Spurious Emission
Frequency (MHz) Limit (dBm) Test Result
polarization Level(dBm)
39.854 Vertical -63.98
2nW/ -57dBm below
63.313 V -66.18
1GHz,
3150.84 V -62.34
39.299 Horizontal -67.35 Pass

190.405 H -67.57 20nW/ -47dBm above

3150.84 H -61.52 1GHz.

Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1706034


No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 13 of 15
Report No: CCISE170603406

7 Test Setup Photo

Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1706034


No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 14 of 15
Report No: CCISE170603406

8 EUT Constructional Details


Reference to the test report No. CCISE170603401

------ End of report ------

Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1706034


No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 15 of 15