BP Report
BP Report
BP Report
Project no:
Author:
Project data
Project name
Project number
Author
Description
Date 28-02-2024
Code AISC/ACI
Material
Steel A36
Concrete 4000 psi
Members
Geometry
Offset
Nam β – Direction γ - Pitch α - Rotation Offset ex Offset ez
Cross-section ey
e [°] [°] [°] [mm] [mm]
[mm]
COL 2 - HEB400 0.0 90.0 0.0 0 0 0
X
Name Support Forces in
[mm]
COL / end Node 0
Project:
Project no:
Author:
Cross-sections
Name Material
2 - HEB400 A36
Anchors
fu
Diameter Gross area
Name Bolt assembly [MPa
[mm] [mm2]
]
25
25 A325M 25 830.0 491
A325M
Vy
Nam N Vz Mx My Mz
Member [kN
e [kN] [kN] [kNm] [kNm] [kNm]
]
LE1 COL / End -200.0 0.0 0.0 0.0 258.0 0.0
Unbalanced forces
Mx
Nam X Y Z My Mz
[kNm
e [kN] [kN] [kN] [kNm] [kNm]
]
LE1 0.0 0.0 -200.0 0.0 258.0 0.0
Project:
Project no:
Author:
Foundation block
Check
Summary
Plates
Design data
Fy
εlim
Material [MPa
[%]
]
A36 248.2 5.0
Symbol explanation
tp Plate thickness
σEd Equivalent stress
εPl Plastic strain
σc,Ed Contact stress
Fy Yield strength
εlim Limit of plastic strain
Project:
Project no:
Author:
Anchors
Design data
ϕNsa
Grade
[kN]
25 A325M - 1 221.9
Symbol explanation
Nf Tension force
V Resultant of bolt shear forces Vy and Vz in shear planes
ϕNp Pullout strength in tension – ACI 318-14 – 17.4.3
ϕNsb Concrete side-face blowout strength in tension – ACI 318-14 – 17.4.4
Utt Utilization in tension
Uts Utilization in shear
Utts Utilization in tension and shear
ϕNsa Steel strength of anchor in tension - ACI 318-14 – 17.4.1
Project:
Project no:
Author:
Detailed result for A2
Concrete splitting failure during installation should be evaluated by ACI 355.2 requirements.
, where:
, where:
, where:
, where:
Welds
tw w L Lc Fn ϕRn Ut
Item Edge Xu Loads Status
[mm] [mm] [mm] [mm] [kN] [kN] [%]
◢ 12.0 ◢ 17.0 130.
BP1 COL-bfl 1 E70xx 300 33 LE1 32.2 24.8 OK
◣ ◣ 1
◢ 12.0 ◢ 17.0 129.
E70xx 299 33 LE1 91.9 70.8 OK
◣ ◣ 9
◢ 12.0 ◢ 17.0 111.
BP1 COL-tfl 1 E70xx 299 33 LE1 72.2 65.1 OK
◣ ◣ 0
◢ 12.0 ◢ 17.0
E70xx 299 33 LE1 50.7 93.7 54.2 OK
◣ ◣
BP1 COL-w 1 E70xx ◢ 6.8 ◣ ◢ 9.5 ◣ 375 31 LE1 51.6 68.7 75.1 OK
E70xx ◢ 6.8 ◣ ◢ 9.5 ◣ 375 31 LE1 51.6 68.7 75.1 OK
BP1 WID1a E70xx ◢ 5.0 ◣ ◢ 7.1 ◣ 109 8 LE1 8.4 11.7 71.2 OK
E70xx ◢ 5.0 ◣ ◢ 7.1 ◣ 109 8 LE1 8.4 11.8 71.1 OK
COL-tfl 1 WID1a E70xx ◢ 5.0 ◣ ◢ 7.1 ◣ 148 8 LE1 6.9 9.2 75.0 OK
E70xx ◢ 5.0 ◣ ◢ 7.1 ◣ 148 8 LE1 6.9 9.2 75.1 OK
BP1 WID1b E70xx ◢ 5.0 ◣ ◢ 7.1 ◣ 109 8 LE1 8.8 12.5 70.3 OK
E70xx ◢ 5.0 ◣ ◢ 7.1 ◣ 109 8 LE1 8.7 12.5 69.4 OK
COL-bfl
WID1b E70xx ◢ 5.0 ◣ ◢ 7.1 ◣ 148 8 LE1 6.9 9.2 75.1 OK
1
E70xx ◢ 5.0 ◣ ◢ 7.1 ◣ 148 8 LE1 6.9 9.2 75.1 OK
BP1 RIB1a E70xx ◢ 5.0 ◣ ◢ 7.1 ◣ 158 8 LE1 2.1 8.9 24.0 OK
E70xx ◢ 5.0 ◣ ◢ 7.1 ◣ 159 8 LE1 2.0 12.6 16.0 OK
COL-w 1 RIB1a E70xx ◢ 5.0 ◣ ◢ 7.1 ◣ 149 8 LE1 1.1 12.6 8.5 OK
E70xx ◢ 5.0 ◣ ◢ 7.1 ◣ 148 8 LE1 1.1 12.7 8.5 OK
BP1 RIB1b E70xx ◢ 5.0 ◣ ◢ 7.1 ◣ 159 8 LE1 2.0 12.6 16.0 OK
E70xx ◢ 5.0 ◣ ◢ 7.1 ◣ 158 8 LE1 2.1 8.9 24.0 OK
COL-w 1 RIB1b E70xx ◢ 5.0 ◣ ◢ 7.1 ◣ 148 8 LE1 1.1 12.7 8.5 OK
E70xx ◢ 5.0 ◣ ◢ 7.1 ◣ 149 8 LE1 1.1 12.6 8.6 OK
Symbol explanation
, where:
482.6 MPa – electrode classification number, i.e. minimum specified tensile strength
Concrete block
A1 A2 σ ϕfp,max Ut
Item Loads Status
[mm2] [mm2] [MPa] [MPa] [%]
CB
LE1 61323 201114 10.4 27.6 37.6 OK
1
Symbol explanation
A1 Loaded area
A2 Supporting area
σ Average stress in concrete
ϕfp,max Concrete bearing resistance
Ut Utilization
, where:
Load V ϕVr μ Ut
Item Status
s [kN] [kN] [-] [%]
BP1 LE1 0.1 165.5 0.40 0.1 OK
Symbol explanation
V Shear force
ϕVr Shear resistance
μ Coefficient of friction between base plate and concrete block
Ut Utilization
Buckling
Code settings
Item Value Unit Reference
Friction coefficient - concrete 0.40 - ACI 349-01 – B.6.1.4
Friction coefficient in slip-resistance 0.30 - AISC 360-22 – J3.9
Limit plastic strain 0.05 -
Detailing No
Distance between bolts [d] 2.66 - AISC 360-22 – J3.4
Distance between bolts and edge [d] 1.25 - AISC 360-22 – J.3.5
Concrete breakout resistance check None
Base metal capacity check at weld fusion face No AISC 360-22 – J2-2
Deformation at bolt hole at service load is design
Yes AISC 360-22 – J3.11
consideration
Cracked concrete Yes ACI 318-14 – 17
Local deformation check No
Local deformation limit 0.03 - CIDECT DG 1, 3 - 1.1
Analysis with large deformations for hollow
Geometrical nonlinearity (GMNA) Yes
section joints