S.N.

Hospital Requirements Bidders Offer Yes/No

Operational Requirements:
1 4K Tower System for Laparoscopy
The 4K system requires the following equipment:
1.1 4K Processor – 1set
1.2 4K Camera Head – 1set
1.3 LED light source with Fiber optic cable – 1set
1.4 4K Monitor -1set
1.6 Trolley- 1set
2 System Requirement:
A 4K Processor:
A.1 The processor should support 2D and 3D in 4K (3840*2160) resolution.

A.2 The camera processor should be ergonomic and user friendly.


A.3 It should have automatic light source control
A.4 It should have natural color settings
A.5 The camera system should be compatible with a 4K-2D camera
head.
A.6 It should have intuitive menu navigation for easier access.
A.7 It should have the facility to save individual preset
A.9 Picture in Picture of visualization modes with Standard and Optical
Contrast Differentiation.
A.10 The system should have facility for capturing Stills images and
Videos in External USB drive.
A.11 The processor should be able to process the innovative
visualization technologies for homogenous illumination and contrast
enhancement.
A.12 System should have facility for Optical Contrast Differentiation System,
and it
should have special filter for observation of capillary vessels and fine
patterns in the superficial layer of mucosa for early detection of lesions.

A.13 It should have multiple source management which should allow


simultaneous control, display, and documentation of image data from
two connected image sources.
A.14 It should have an innovative design for parallel display of standard
images and enhanced-image technology.
A.16 Video Outputs: DVI-D, DP or 3G-HD-
SDI, 12G-SDI or 3G-SDI
A.17 It should have 4 USB interfaces.

A.18 The processor should be Compatible with flexible scopes and 3D scope
as well.

A.19 Automatic adjustment of light intensity of light source and controlled from
Camera head.

B 4k Camera Head
B.1 Image display in 16:9 format with 3840 x 2160 pixels or better.

B.2 Grip mechanism should be standard eyepiece adaptor.

B.3 scanning method should be progressive scan.

B.4 Image sensor type should be CMOS sensor.

B.5 The camera head should be digital through and through: This
system allows the optical image to be converted into a digital image at
the earliest possible stage: Directly in the CMOS sensor chip.

B.6 Control buttons: 3 (2 of them freely programmable).

B.7 It should have digital zoom.


B.8 Lens:
Integrated Zoom Lens f = 19 mm
B.9
AGC: Microprocessor controlled

B.11 Camera Head should have an adaptive zoom facility for full screen
image.
B.13 Adjustment of light intensity of light source should be controlled from
Camera head buttons.
B.14 Integrated camera cable of 3m with special plug for Control unit.

C LED Light Source


C.1 The light source should be an LED 300 Watt white light cold light
source with a light connection for use with suitable endoscopes,
with an integrated high-performance LED module having high
light intensity and minimal energy consumption and suitable for
white light and should have the following specifications:
C.2 The Lamp type should be High-performance LEDs, white light LED

C.3 The light source should have high-performing LEDS that are active
individually and simultaneously
C.4 The Light intensity adjustment should be controlled via manual by
single touch or via a automatic by camera head.
C.5 Extremely long average LED lamp life of 30,000 hours or more.

C.6 Natural color rendition with pure white


C.7 The LED Light muat be Laserfree
C.7 Light intensity can be manually fine-tuned.
C.8 Standby button with memory function (remembers last
brightness level selected).

C.9 It should have an intuitive and user-friendly touch screen interface.


C.10 Very high energy efficiency with the latest LED
technology.
C.11 Should have Lumen >2000
D Fiber optic light cable:
D.1 should have straight connector,extremely heat resistance with safety
lock,diameter 4.8mm,length 250cm.
E 4K Monitor
E.1 The supplier should provide a monitor from the principal company
which should be all in one Medical Grade Monitor capable of
displaying:
E.2 Approx 31" size or more
E.3 Resolution :3840 x 2160 px
E.4 Aspect ratio 16:9
Contrast ratio 1350:1
E.5 should have:-
SDI input -1:12G-SDI output-1:3G-SDI input- 1:DisplayPort 1.2 input-
1:DVI-D input -1:DVI-D output- 1:RJ45 -1
E.6 Picture in/out Picture should be available.
E.7 178-degree angle of view

F Trolley
The supplier should provide a trolley with inbuilt power point
connection

Note :- All Visual System Equipment’s including Camera, Processor, Light source and monitor should be certified by US FDA and CE
European notified body. It Should be from Same manufacturer for better compatibility and outcome.
Remarks